• Title/Summary/Keyword: Cement retention

Search Result 99, Processing Time 0.027 seconds

THE RETENTION OF FULL VENEER GOLD CROWN BY CORE MATERIAL AND DENTAL CEMENT (Core와 시멘트의 종류가 전부주조금관의 유지력에 미치는 영향)

  • Ha Jum-Im;Cho Hye-Won;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.93-101
    • /
    • 1992
  • The purpose of this study was to evaluate the effectiveness of core materials and luting agents on the retention of full veneer gold crown. The core materials used in this study was dental amalgam, and composite resin, and the luting agents were zinc phosphate cement, polycarboxylate cement, and glass ionomer cement. The obtained results were as follows. 1. In full veneer gold crown supported by composite resin core, the crown retention with zinc phosphate cement was the highest of all. 2. In full veneer gold crown supported by amalgam core, the crown retention was shown no statistical difference by luting agent. 3. There was no statistical difference in the crown retention between the full veneer gold crown supported by composite resin core and dental amalgam core.

  • PDF

Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments

  • Safari, Sina;Ghavam, Fereshteh Hosseini;Amini, Parviz;Yaghmaei, Kaveh
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • PURPOSE. The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. MATERIALS AND METHODS. Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (${\alpha}=.05$). RESULTS. The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly (P=.006). The difference in retention between the cemented and recemented copings was not statistically significant (P=.40). CONCLUSION. Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement.

Fluidity Retention of Cement-Based Composites Using High range water reducing AE agent (고성능AE감수재를 사용한 시멘트복합체의 유동성 유지성능)

  • 김기형;김인수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.93-98
    • /
    • 1998
  • Fluidity retention of concrete used high range water reducing AE agent(HWAE) is varied according to type, dosage amount and dosing method of HWAE. The type and substitution ratio of mineral admixture also have influence on the fluidity retention of concrete using HWAE. For the purpose of improving the fluidity retention in concrete used HWAE, 3 types of HWAE and ground granulated blast furnace slag(SG) are applied in cement-based composites such as cement paste, mortar and concrete respectively. According to using the HWAE of naphthalene sulfonates and SG, the fluidity retention of mortar and concerete is improving the fluidity retention and strength of concrete regardless of type of HWAE.

  • PDF

THE RETRIEVABILITY OF CEMENTATION TYPE IMPLANT ABUTMENT BY SURFACE TREATEMENTS AND TYPES OF CEMENTS (Cemented type implant에서 지대치의 표면조도와 cement의 종류가 Retrievability에 미치는 영향에 관한 연구)

  • Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.651-657
    • /
    • 1999
  • This study was performed to investigate the retrievability of the cementation type implant abutments. The cements used in this study were Cavitec, Tembond and Zinc Phosphate Cement. The types of surface conditioning were no treatment, 50 microne sandblasting, 250 microne sandblasting, fine diamond finishing point and coarse diamond point. The retention of cast crown was measured with Instron Universal Testing Machine(Instron Engineering Co., U.S.A.). The results were as fellows: 1. The Maximium retention was obtained by the group of Z.P.C. cementation and Coarse diamond point surface conditioning. 2. Z.P.C. shows maximum retention, and reduced in orders Tembond, Cavitec, No cement. 3. The value of retention of surface condition was highest in coarse diamond point, lowest in no tretment. 4. The similar results were obtained between fine diamond point and 50 microne sandblasting, coarse diamond point and 250 microne sandblasting. 5. The were no direct corelation between mechanical retention and cementation retention.

  • PDF

The Comparison of the Retention of the Full Veneer Casted Gold Crowns with Different Implant Abutment Shapes and Types of Cements (임플란트 지대주 형태와 시멘트 종류에 따른 전부주조금관의 유지력 비교)

  • Jung, Jae-Wook;Kim, Jee-hwan;Kim, Sun-jai;Moon, Hong-suk;Shim, June-sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.403-415
    • /
    • 2009
  • The purpose of the study is to establish the effect of different abutment shapes and types of cements on the retention of the full veneer casted gold crowns. Metal dies that has the similar shape with the implant abutment were manufactured using a short(5mm) and long(10mm) dies with different convergence angles. Metal dies and gold crowns, which were made from the metal dies, were cemented with Temp-bond, Temp-bond mixed with petroleum jelly, ZPC and Premier implant cement. After that, these were tested for tensile force at the point of separation. The effect of convergence angle changes of different cement types on the retention was studied as well as the effects of the cement type changes with different convergence angles on the retention. In addition, study about the marginal gap of Premier implant cement used for this experiment was conducted. The results are as followed under the in-vitro experimental limits; 1. The retention of the Temp-bond mixed with petroleum jelly decreased as the convergence angle increased, and the retention was weakest among the cements. 2. The retention of ZPC decreased as convergence angle increased. When convergence angle was 5 degrees, ZPC showed stronger retention than Premier implant cement. 3. Premier implant cement had the weakest retention when the convergence angle was 5 degrees but when the convergence angle was 10 degrees, it had the strongest retention. As the angle increased more than 10 degrees, the retention decreased. 4. Premier implant cement showed bigger marginal gap when the convergence angle was 5 degrees than 10 degrees under the experimental condition.

The selection criteria of temporary or permanent luting agents in implant-supported prostheses: in vitro study

  • Alvarez-Arenal, Angel;Gonzalez-Gonzalez, Ignacio;deLlanos-Lanchares, Hector;Brizuela-Velasco, Aritza;Ellacuria-Echebarria, Joseba
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.144-149
    • /
    • 2016
  • PURPOSE. The use of temporary or permanent cements in fixed implant-supported prostheses is under discussion. The objective was to compare the retentiveness of one temporary and two permanent cements after cyclic compressive loading. MATERIALS AND METHODS. The working model was five solid abutments screwed to five implant analogs. Thirty Cr-Ni alloy copings were randomized and cemented to the abutments with one temporary (resin urethane-based) or two permanent (resin-modified glass ionomer, resin-composite) cements. The retention strength was measured twice: once after the copings were cemented and again after a compressive cyclic loading of 100 N at 0.72 Hz (100,000 cycles). RESULTS. Before loading, the retention strength of resin composite was 75% higher than the resin-modified glass ionomer and 2.5 times higher than resin urethane-based cement. After loading, the retentiveness of the three cements decreased in a non-uniform manner. The greatest percentage of retention loss was shown by the temporary cement and the lowest by the permanent resin composite. However, the two permanent cements consistently show high retention values. CONCLUSION. The higher the initial retention of each cement, the lower the percentage of retention loss after compressive cyclic loading. After loading, the resin urethane-based cement was the most favourable cement for retrieving the crowns and resin composite was the most favourable cement to keep them in place.

A STUDY ON THE RETENTION OF CAST POST (주조 포스트의 유지력에 관한 연구)

  • Kim Sung-Hoon;Cho Hye-Won;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.461-467
    • /
    • 1993
  • The purpose of this study was to evaluate the effects of method for construction of cast post and type of dental cement on the retention of cast post. The wax patterns or Duralay resin patterns were used for construction of cast post. The dental cements used in this study were zinc phosphate cement(Fleck's zinc cement, Mizzy INc., U.S.A.), glass ionomer cement(Fuji I, G-C Co., Japan), and resin cement(Panavia-EX, Kuraray Co., Japan) and the retention of cast post was measured with Instron Universal Test Machine(Instron Engineering Co., U.S.A.). The obtained results were as follows : 1. The tensile bond strength of cast posts made by Duralay resin patterns revealed 39.13(kg) with Panavia-EX, 46.40(kg) with phosphate cement, and 37.78(kg) with glass ionomer cement. 2. The tensile bond strength of cast posts made by wax patterns revealed 39.25(kg) with Panavia, EX, 44.12(kg) with phosphate cement, and 40.23(kg) with glass ionomer cement. 3. The tensile bond strength of cast posts made by Duralay resin patterns or wax patterns were not affected by the type of dental cements(P>0.05).

  • PDF

A literature review on cementation of implant prosthesis (임플란트 보철물의 합착에 대한 문헌고찰)

  • Lee, Eun-Suk;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.458-467
    • /
    • 2016
  • Cement-retained implant prosthesis has several advantages in the esthetic and occlusal aspects. However, the difficulty of the retrievability and the possibility of peri-implantitis induced by the cement excess would be a threatening factor to the implant prognosis. Peri-implantitis resulting from the remaining cement could occur later on to the patients with periodontitis history. Retention can be controlled by selecting the right cement type. Retention of the cement was the strongest in the resin cement, followed by resin modified glass ionomer cement, poIycarboxylate cement, zinc phosphate cement and glass ionomer cement. Retention of the provisional cement weakened after thermocycling. Other factors such as the abutment number, abutment alignment, height and taper of the abutment can also affect the total retention. To the success of the cement-retained prosthesis, it's important to select the right cement for the clinical purpose. The prosthesis should be fabricated in accordance with the biomechanical requirements. The prosthesis should be cemented with the techniques to reduce the excess cement as much as possible. In addition, the excess cement should be identified using the radiography and carefully removed.

Fluidity and Setting Properties of Cement Paste by Adding of Fluoro Anhydrite and Fly Ash (불산 무수석고와 플라이 애쉬를 첨가한 시멘트 페이스트의 유동성 및 응결특성)

  • 노재성;김도수;홍성수;임계규;임헌성
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.12
    • /
    • pp.1261-1267
    • /
    • 1997
  • Four kids of powder admixtures(A, B, C, D) based on anhydrite were manufactured by mixing at a fixed rate of II-anhydrite, fly ash and active silica as an industrial by-product. Fluidity properties of cement paste such as mini-slump, apparent viscosity with elapsed time, as well as setting time of cement pastes of these admixtures substituted up to 11wt% of cement were compared to those of cement paste(SS) substisuted by marketed high-strength powder admixture(S). Among these powder admixtures, the fluidity of cement pastes(PA, PC) substituted by A and C powder admixtures manufactured from II-anhydrite and fly ash had an excellent property than that of cement paste substituted by marketed powder admixture and also a good fluidity-retention effect with elapsed time by adding of superplasticizer. The setting time of cement paste substituted by powder admixtures based on anhydrite slightly retarded than that of cement paste substituted by marketed powder admixture.

  • PDF