• 제목/요약/키워드: Cell wall

검색결과 1,895건 처리시간 0.037초

산성조건하에서 시판요구르트의 유산균 생존률과 ${\beta}-galactosidase$의 활성도 (Survival Rate of Lactic Acid Bacteria and the Change of ${\beta}-Galactosidase$ Activity in Commercial Yogurts Under the Acidic Conditions)

  • 신용서;성현주;김동한;이갑상
    • Applied Biological Chemistry
    • /
    • 제37권3호
    • /
    • pp.143-147
    • /
    • 1994
  • 국내에서 시판되는 요구르트(plain)의 이화학적 특성 및 산성조건하에서의 유산균의 생존률과 ${\beta}-galactosidase$의 활성도를 측정하였다. pH는 $3.71{\sim}4.08$범위, 적정산도는 $0.990{\sim}1.045%$, 점도는 $256{\sim}3,164\;cps$ 범위였으며, 유산균수는 $10^{8-9}\;cfu/ml$로 규정보다 높았다. 완충능은 요구르트(50 ml)의 고유 pH값에서 -2의 pH값까지 적정하는 데 소비된 1.0 M-HCl의 량으로 $3.58{\sim}4.33\;ml$였다. 산성조건하에서 유산균의 생존율은 pH 3.5에서는 2시간 동안 거의 변화가 없었으며, pH 2.5, 1.5에서는 각각 $3.5{\times}10^{-2}{\sim}3.6{\times}10^{-1}%,\;8.3{\times}10^{-5}{\sim}4.2{\times}10^{-3}%$ 범위였다. ${\beta}-galactosidase$활성은 120분 후에 pH 3.5에서는 큰 변화가 없었으며, pH 2.5, 1.5에서 ${\beta}-galactosidase$의 잔존활성은 각각 $9.4{\sim}36.2%.\;4.2{\sim}19.0%$ 범위로 나타났다. 이상의 결과로 요구르트를 섭취하였을 때 유산균은 위산에 노출되어 극히 그 일부만이 장내에 도달할 수 있을 것이라고 판단되며, ${\beta}-galactosidase$는 유산균의 세포벽이나 세포막 및 요구르트에 포함된 무지고형분의 보호를 받아 그 활성을 어느정도 유지할 수 있으리라 사료된다.

  • PDF

볍씨의 규산코팅방법에 따른 이용특성과 육묘효과 (Methods of Application and Beneficial Effects of Silicate-Coating Rice Seeds)

  • 강양순;김완중;황덕상;김희규
    • 한국작물학회지
    • /
    • 제65권1호
    • /
    • pp.30-39
    • /
    • 2020
  • 벼 직파재배나 육묘에서 종자소독, 병충해방제, 시비 등에 요구되는 생산비절감기술로 개발된 기존 규산코팅볍씨(규산/Zeolite)의 단점 보완으로 신규 규산코팅기술이 개발되었다. 신규 규산코팅볍씨의 제조 및 이용특성과 육묘상자에서 건묘육성 및 벼 키다리병 경감효과를 명확하게 하기 위하여 벼 키다리병 이병성 감염종자를 소독 없이 마른 상태로 코팅한 볍씨와 중도저항성 소독된 보급종자를 마른 상태로 코팅한 볍씨를 토경조건과 수경조건에서 시험이 수행되었다. 1. 신규 규산코팅볍씨는 종자 100 g에 코팅 바인더 점액성 수용성규산 18 ml을 충분히 묻히고 거기에 Dolomite 80 g/철 5 g의 혼합분말을 고루 뿌려서 코팅되었다. 2. 신규 규산코팅볍씨의 특성은 종자무게의 1.84배이었고 중량, 코팅강도와 코팅색택 등이 기존 규산코팅볍씨보다 훨씬 개선되었다. 3. 신규 규산코팅볍씨의 묘는 무코팅볍씨에서 자란 묘의 연한 엽색과 늘어지는 초형에 비하여 짙은 엽색(SPAD치)으로 직립되었고 엽신의 규질화가 현저히 높았으며 묘소질(w/cm)은 유의하게 증가되었다. 특히 생육량과 엽색도는 토경조건에서 보다 영양이 결제된 수경조건에서 뚜렷하였다. 4. 47일간 육묘 중 벼 키다리병 발생은 파종 후 38일에 peak를 보였고 무코팅볍씨 발병률 54.2%에 비하여 신규 규산코팅에서는 68.8~70.7%의 방제가를 나타내었다. 이상을 종합하여 보면 벼농사에서 가장 많이 요구되는 규산질 비료를 Dolomite와 철분으로 종피에 코팅시켜서 만든 신규 규산코팅볍씨로 종자소독, 건묘육성 및 벼 키다리병 경감 효과 등은 친환경 저비용과 안전 쌀 생산에 크게 기여되리라 본다. 또한 장기 영양결제에도 육묘 중 뿌리 활력이나 엽의 노화 없이 정상생육이 지속되어 육묘시비량 절감 가능성도 보였고 금후 묘의 노화경감을 위한 최소 영양공급 연구가 요구되었다.

폐암의 정위적체부방사선치료에서 육안적종양체적 변화에 따른 적응방사선치료의 효용성 및 가능성 연구 (Feasibility and Efficacy of Adaptive Intensity Modulated Radiotherapy Planning according to Tumor Volume Change in Early Stage Non-small Cell Lung Cancer with Stereotactic Body Radiotherapy)

  • 박재원;강민규;예지원
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.79-86
    • /
    • 2015
  • 이 연구는 조기 폐암의 정위방사선치료에서 육안적종양체적(Gross tumor volume, GTV) 변화에 따른 적응방사선치료(ART)의 효과 및 가능성을 보기 위해 시행되었다. 영남대학교 의료원에서 정위방사선치료를 시행한 22개의 종양을 대상으로 연구를 진행하였다. 정위방사선치료는 2주에 걸쳐 48 혹은 60 Gy를 4회에 나누어 조사하는 방법으로 시행되었다. 종양체적 변화를 측정하기 위해 매 콘빔시티마다 육안적종양체적에 대한 윤곽선 그리기를 시행하였다. 그 다음 첫 번째 콘빔시티에 기준 치료계획으로 사용할 세기조절방사선치료 계획을 시행하였다. 적응방사선치료 계획을 하기 위해, 2, 3, 4번째 콘빔시티에 기준 치료계획과 동일한 빔 각도와 제약을 적용하여 각각 재 최적화 과정을 진행하였다. 이후 적응방사선치료 계획은 기준치료계획을 각각의 콘빔시티에 복사하여 생성한 비적응방사선치료 계획과 비교되었다. 평균 육안적종양체적은 10.7 cc였다. 평균 종양체적 변화는 두 번째, 세 번째, 네 번째 콘빔시티에서 각각 -1.5%, 7.3%, 25.1%였으며 세 번째 이후 변화는 통계적으로 유의하였다(p<0.05). 하지만 두 번째 콘빔시티에서는 9개의 종양 체적이 증가하였다. 적응방사선치료 계획을 시행하였을 때, 폐에서 $V_{20\;Gy}$, $D_{1500\;cc}$, $D_{1000\;cc}$가 유의하게 감소하였으며, 흉벽에 대한 $V_{30\;Gy}$$V_{32\;Gy}$ 역시 유의하게 감소하였다(p<0.05). 두 번째 콘빔시티의 종양체적이 증가한 환자들에서, 기준치료 계획에 비해 적응치료방사선치료 계획을 시행하지 않았을 때, 계획용 표적체적에 대한 선량 범위 변수 중 $D_{min}$은 8.3% 감소한 반면 (p=0.021), 적응방사선치료계획을 시행한 경우에는 차이가 없었다. 이러한 결과를 보았을 때, 적응방사선치료 계획을 함으로서 표적 선량 커버는 개선시키면서 손상위험장기에 대한 선량을 감소시킬 수 있을 것이다. 그러므로, 콘빔시티를 이용한 적응방사선치료 방법은 조기 폐암의 정위방사선치료에서 고려되어야 하겠다.

방향성 좀목형(Vitex negundo)모용의 구조적 분화발달 (Structural Features of Various Trichomes in Vitex negundo during Development)

  • 이승희;김인선
    • Applied Microscopy
    • /
    • 제36권1호
    • /
    • pp.35-45
    • /
    • 2006
  • 방향성 식물은 식물체 특정부위에 분비구조를 발달시켜 활성물질을 세포의 외부 또는 세포간극으로 방출한다. 민간에서 약용으로 활용되는 좀목형 (Vitex negundo var. incisa)은 독특한 향기를 강하게 발산하는 식물로 향의 근원은 표피조직에 발달하는 분비모 등에 의한 것으로 추정되고 있다. 이에 본 연구에서는 좀목형의 잎 및 줄기 표피조직에 발달하는 모용에 대하여 생장단계별로 형태 및 세포수준에서의 구조분화 양상을 연구하였다. 좀목형에 발달하는 분비모는 4개의 분비세포(ca. $50{\mu}m$ 직경)와 병세포(ca. $5{\mu}m$ 길이)로 분화하는 peltate 유형 (Type 1), 2개의 분비세포$(ca.\;15{\mu}m)$), 병세포$(5{\sim}10{\mu}m)$), 기저세포로 이루어진 capitate유형 (Type 2), 정단의 분비세포가 초기단계에서부터 퇴화되는 degraded capitate 유형 (Type 3)으로 분화하였다. 비분비모는 특히 하피 전체에 더 발달하는 장상의 다세포성 모용($110{\sim}190{\mu}m$, Type4)과 상 하피 전체에 밀생하는 단세포성 모용($20{\sim}30{\mu}m$, Type 5)으로 대별되었다. 분화초기 분비모 정단의 분비세포에서는 큐티클층이 세포벽으로부터 서서히 분리되어 팽창되면서 분비강이 형성되었다. 분비세포 세포질에서 생성된 물질은 세포벽을 통해 운반되어 분비강에 형성된 많은 분비소포에 저장되고, 이들 소포가 팽창된 분비강을 가득 채우며 생성되는 물질들을 축적한 후 방향성분 및 관련 물질을 누출상 분비방식으로 세포간극 또는 외부로 방출하는 것으로 추정된다. 이와 같이 좀목형에서는 peltate및 capitate유형 (Type 1, 2)이 분비기작에서 매우 중요한 역할을 하는 것으로 사료된다. 본 연구에서 밝혀진 좀목형의 분비구조에 대한 정보는 방향성 약용식물이 함유하는 특정물질의 기능성 성분 추적 연구 등에서 매우 유용하게 활용될 수 있는 자료가 될 것이다.

홍삼추출액은 lipoteichoic acid로 자극된 소교세포에서 Akt 및 MAPK 의존적으로 heme oxygenase-1 발현을 유도함으로써 NO 생성을 억제함 (A Formulated Korean Red Ginseng Extract Inhibited Nitric Oxide Production through Akt- and Mitogen Activated Protein Kinase-dependent Heme Oxygenase-1 Upregulation in Lipoteichoic Acid-stimulated Microglial Cells)

  • 신지은;이경민;김지희;이스칸더 마디;김영희
    • 생명과학회지
    • /
    • 제29권4호
    • /
    • pp.402-409
    • /
    • 2019
  • 생삼을 쪄서 건조시킨 홍삼은 전통적으로 사용되고 있는 약재로서 면역, 내분비 및 중추신경계 작용을 증진시키며 염증을 억제하는 효과가 있는 것으로 알려져 있다. 본 연구에서는 그람 양성균의 세포벽 성분인 lipoteichoic acid (LTA)에 의한 염증반응에 홍삼추출액(RGE)이 항염증 효과를 가지는지 관찰하고 그 작용 기전을 연구하였다. BV-2 소교세포에서 RGE는 세포에 독성을 유도하지 않으면서 LTA로 인한 nitric oxide (NO)의 생성과 inducible nitric oxide synthase (iNOS) 발현을 억제하였으며, NF-kB p65의 핵으로의 이동과 IkB-a의 분해 또한 억제하였다. 한편, RGE는 농도의존적으로 heme oxygenase-1 (HO-1)의 발현을 유도하였으며, HO-1 siRNA를 처리했을 때는 RGE가 iNOS의 발현을 억제하지 못하였다. RGE는 HO-1의 발현에 관여하는 전사인자인 nuclear factor E2-related factor 2 (Nrf2)를 핵으로 이동을 촉진시켰다. 또한 RGE에 의한 HO-1의 발현은 phosphatidylinositol-3-kinase(PI-3K) 및 MAPK 억제제에 의해 감소되었으며, RGE가 Akt와 ERK, p38, JNK의 인산화를 유도하였다. 이상의 결과를 종합해보면, RGE는 PI-3K/Akt 및 ERK, p38, JNK 신호전달과정을 통해 HO-1의 발현을 유도함으로써 NO와 같은 염증매개물질의 생성을 억제한다는 것을 알 수 있다. 그러므로 홍삼추출액은 그람 양성균에 의한 신경염증과 염증관련 신경계 질환의 치료제로서 사용될 수 있을 것이라 사료된다.

경찰특공대 요원의 방사선손상 감소를 위한 셀레늄과 아르기닌 혼합물의 방호효과 연구 (A Study on the Radioprotection Effect of Selenium and Arginine Mixtures for Reducing Radiation Damage to Police SOU)

  • 정근우;김해숙;박재형;주성현;최제경;천세임;민병인
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.119-125
    • /
    • 2024
  • 본 연구의 목적은 방사능 테러 상황에서 경찰특공대 대테러요원의 방사선 손상을 최소화할 수 있는 방사선 방호제 개발을 위하여 셀레늄과 아르기닌 혼합물의 방사선 방호효과를 규명하는 것이다. 본 연구에서는 72 마리의 수컷 SD rat을 일반군(NC Group), 셀레늄과 아르기닌 혼합물 투여군(SeAr Group), 방사선 노출군(IR Group), 셀레늄과 아르기닌 혼합물 투여 후 방사선 노출군(SeAr+IR Group)의 4개 군으로 분류하였다. 방사선은 7 Gy 엑스선을 전신에 노출하였고, 셀레늄과 아르기닌은 각각 1일 1회 3 mg/kg, 150 mg/kg이 흡수되도록 혼합하여 14일간 경구 투여였다. 방사선 노출 후 1일, 7일, 21일차에 혈액학적 분석과 조직학적 분석을 수행하였다. 혈액학적 분석에서는 IR Group에 비하여 SeAr+IR Group에서 방사선 노출 후 1일차에 림프구(p<0.05)에서, 7일차에 혈소판(p<0.01)에서, 21일차에 적혈구(p<0.01)에서 유의한 방사선 방호가 나타났다. 조직학적 분석에는 IR Group에 비하여 SeAr+IR Group에서 방사선 노출 7일차에 소장에서 소장움 세포의 경계가 적게 무너지고 소장움의 길이가 비교적 회복된 것이 관찰되었고, 21일차에 전립선에서 세포수와 세포벽의 두께가 더 양호한 것으로 관찰되었다. 따라서 셀레늄과 아르기닌 혼합물은 방사선 노출에 따른 혈액 및 조직에 대한 방사선 방호효과가 있는 것으로 판단되며 경찰특공대 대테러요원의 방사선 손상 감소를 위한 방사선 방호제 연구에 유용하게 활용될 것으로 기대된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

표지방식을 이용한 흰 쥐 복강 내장을 지배하는 감각신경세포체와 신경섬유의 표지부위 (Localization of Sensory Neurons Innervating the Rat Intestine Using the Cholera Toxin B Subunit(CTB) and Wheat Germ Agglutinin-Horseradish Peroxidase(WGA-HRP))

  • 이동협;이창현;이무삼
    • Journal of Yeungnam Medical Science
    • /
    • 제15권1호
    • /
    • pp.75-96
    • /
    • 1998
  • 복강내장을 지배하는 감각신경세포체 및 신경섬유의 표지부위를 관찰하기 위하여 복강내장을 부위별(위, 십이지장, 공장, 회장, 맹장, 오름결장, 내림결장)로 나누어 2.5% WGA-HRP $30{\mu}l$와 0.5% CTB $20{\mu}l$를 장막과 근육층 사이의 4부위에 나누어 주입하였다. 그 후 48-96시간의 생존시간이 경과한 후 뇌줄기, 척수신경절과 미주신경절에서의 감각신경섬유와 신경세포체의 표지부위를 면역조직화학 염색법과 HRP 조직화학 기법으로 관찰한 결과는 다음과 같다. 1. WGA-HRP에 표지된 감각신경섬유는 위와 맹장에서만 관찰되었으며, CTB에 표지된 감각신경섬유는 복강내장의 모든 장기에서 관찰되었다. 2. 복강내장을 지배하는 감각신경섬유는 뇌줄기내 좌우 고립로핵의 교질부, 교질부의 등쪽내측부, 교차연결부, 내측부, 넷째뇌실벽, 맨아래구역의 앞쪽경계 및 중심관의 등쪽 정중선인 교차연결부에 국소적으로 강하게 표지되었다. 3. 척수신경절에서 위 (stomach)에 분포하는 감각신경세포체는 좌우 관계없이 $T_2$에서 $L_1$까지 여러 신경절에 표지되었으며 이 중 좌우 $T_{8-9}$부위에 가장 많이 표지되었다. 4. 십이지장에서의 척수신경절에 표지된 감각 신경세포체는 좌우 $T_6-L_2$부위에 표지되었으나 다른 장기에 비하여 표지된 감각신경세포체의 수는 적었다. 5. 공장에서의 척수신경절에 표지된 감각신경세포체는 좌우 $T_6-L_2$부위에 표지되었다. 가장 많이 표지된 부위는 좌측 $T_{12}$ 부위였으며, 우측은 $T_{13}$ 부위에 표지되었다. 6. 회장에서의 척수신경절에 표지된 감각신경세포체는 좌우 $T_6-L_2$부위였다. 가장 많이 표지된 부위는 좌측에서 $T_{11}$부위였고, 우측에서 $L_1$부위였다. 7. 맹장에서의 척수신경절에 표지된 감각신경 세포체는 좌측은 $T_7-L_2$부위였으며 우측은 $T_6-L_1$부위였다. 가장 많이 표지된 부위는 좌측은 $T_{11}$이었으며, 우측은 $T_{11-12}$에 표지되었다. 8. 오름결장에서 척수신경절에 표지된 감각신경세포체는 좌측은 $T_7-L_2$부위에 표지되었고 우측은 $T_9-L_4$부위에 표지되어 좌우측 표지부위의 차이를 보였다. 가장 많이 표지된 부위는 좌측은 $T_9$이었으며, 우측은 $T_{11}$에 표지되었다. 9. 내림결장에서 척수신경절에 표지된 감각신경 세포체는 좌측은 $T_9-L_2$부위에 표지되었고 우측은 $T_6-L_2$부위에 표지되었다. 가장 많이 표지된 부위는 좌측은 $T_{13}$이었으며, 우측은 $L_1$에 표지되었다. 10. 복강내장을 지배하는 좌우 미주신경절에 표지된 감각신경세포체는 위에서 가장 많이 표지되었으며 위를 제외한 나머지 장기에서는 표지된 감각신경세포체의 수는 위에 표지된 수보다 적었다. 이상의 결과로 흰쥐의 복강내장을 지배하는 감각신경섬유의 뇌줄기내 표지영역은 좌우 고립로 핵의 교질부, 교질부의 등쪽내측부, 교차연결부, 내측부, 넷째뇌실벽, 맨아래구역의 앞쪽경계 및 중심관의 등쪽 정중선인 교차연결부였으며, 감각신경세포체의 표지영역은 미주신경절과 척수신경절 $T_2-L_4$ 부위였음을 알 수 있었다. 위를 제외한 나머지 장기들에서는 $T_6-L_4$부위에 표지되었으나 소장에서 대장으로 갈수록 가장 많이 표지된 부위는 원위부 가슴신경절에서 근위부 허리신경절쪽으로 이동하는 경향을 보였다.

  • PDF

Gibberellic acid와 여러 가지 제초제와의 혼합처리가 메귀리에 대한 제초활성에 미치는 영향 (Effect of mixtures of gibberellic acid and several herbicides on the herbicidal activity against wild oat (Avena fatua L.))

  • 김진석;최정섭;홍경식;조광연
    • 농약과학회지
    • /
    • 제2권3호
    • /
    • pp.107-116
    • /
    • 1998
  • Gibberellic acid에 대한 밀과 메귀리간에 차등반응을 이용하여 제초제에 gibberellic acid를 첨가함으로써 상대적으로 민감한 반응을 보였던 메귀리를 효과적으로 방제할 수 있는 조합을 찾고, 그 효과증대의 생리적 원인을 조사하고자 실험하였다. 밀은 $GA_{3}$에 대한 낮은 신장반응을 보였으나, 메귀리는 이보다 $4{\sim}5$배 높은 반응을 보였다. $GA_{3}$에 침지된 메귀리 종자를 파종한 후 토양처리했을 때는 isoproturon, trifluralin의 효과가 증진되었다. 경엽처리의 경우 $GA_{3}$는 tralkoxydim fenoxaprop-ethyl, metsulfuron-methyl, metribuzine, isoproturon의 효과를 증진시켰으나, oxyfluofen과 paraquat의 효과에는 거의 영향을 미치지 않았다. 경엽처리조건에서 체계처리를 할 경우 tralkoxydim처리 이전에 $GA_{3}$를 처리하면 tralkoxydim의 효과를 증진시켰으나, tralkoxydim처리 이후에 $GA_{3}$를 처리하면 효과가 낮은 경향이었다. 그러나 $GA_{3}$를 어느 시기에 처리하여도 tralkoxydim의 신장저해효과를 증진 또는 경감시키지는 못하였고, $GA_{3}$가 처리된 잎의 과산화작용 화합물에 대한 반응은 무처리와 비교하여 일정한 경향을 보이지 않았다. 이들 결과로 보아 $GA_{3}$가 일부 제초제의 효과를 증진시킨 것은 조직의 연화(세포신장 촉진)에 의한 높은 제초반응 때문이라기보다는 제초제 흡수, 이행의 변화 또는 제초작용 발현과 관련한 체내대사의 촉진 때문으로 추정된다.

  • PDF