• 제목/요약/키워드: Cell surface properties

검색결과 770건 처리시간 0.035초

BIOLOGICAL RESPONSES OF OSTEOBLAST-LIKE CELLS TO DIFFERENT TITANIUM SURFACE BY ANODIZING MODIFICATION

  • Kim Myung-Joo;Kim Chang-Whe;Lim Young-Jun;Park Hyun-Joo
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.751-763
    • /
    • 2005
  • Statement of problem. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. The surface quality of the implant depends on the chemical, physical, mechanical and topographical properties of the surface. The different properties will interact with each other and a change in thickness of the oxide layer may also result in a change in surface energy, the surface topography and surface, chemical composition. However, there is limited the comprehensive study with regard to changed surface and biologic behavior of osteoblast by anodization. Purpose of study. The aim of this study was to analyze the characteristics of an oxide layer formed and to evaluate the cellular biologic behaviors on titanium by anodic oxidation (anodization) by cellular proliferation, differentiation, ECM formation and gene expression. And the phospholipase activity was measured on the anodized surface as preliminary study to understand how surface properties of Ti implant are transduced into downstream cellular events. Methods and Materials. The surface of a commercially pure titanium(Grade 2) was modified by anodic oxidation. The group 1 samples had a machined surface and other three experimental specimens were anodized under a constant voltage of 270 V(Group 2), 350 V(Group 3), and 450 V(Group 4). The specimen characteristics were inspected using the following five categories; the surface morphology, the surface roughness, the thickness of oxide layer, the crystallinity, and the chemical composition of the oxide layer. Cell numbers were taken as a marker for cell proliferation. While the expression of alkaline phosphatase and Runx2 (Cbfa1) was used as early differentiation marker for osteoblast. The type I collagen production was determined, which constitutes the main structural protein of the extracellular matrix. Phospholipase $A_2$ and D activity were detected. Results. (1) The anodized titanium had a porous oxide layer, and there was increase in both the size and number of pores with increasing anodizing voltage. (2) With increasing voltage, the surface roughness and thickness of the oxide film increased significantly (p<0.01), the $TiO_2$phase changed from anatase to rutile. During the anodic oxidization, Ca and P ions were more incorporated into the oxide layer. (3) The in vitro cell responses of the specimen were also dependant on the oxidation conditions. With increasing voltage, the ALP activity, type I collagen production, and Cbfa 1 gene expression increased significantly (p<0.01), while the cell proliferation decreased. (4) In preliminary study on the relation of surface property and phospholipase, PLD activity was increased but $PLA_2$ activity did not changed according to applied voltage. Conclusion. The anodized titanium shows improved surface characteristics than the machined titanium. The surface properties acquired by anodization appear to give rise more mature osteoblast characteristics and might result in increased bone growth, and contribute to the achievement of a tight fixation. The precise mechanism of surface property signaling is not known, may be related to phospholipase D.

ELID 경면 연삭 가공된 티타늄 표면의 세포 활성도 (Cell Activity of ELID-Machined Titanium Surface)

  • 강종호;이명현;서원선;이석원;곽태수;최헌진
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.13-18
    • /
    • 2012
  • We investigated the cell activity of controlled titanium surface using various grinding methods including ELID (Electrolytic In-Process Dressing) grinding method. The influence of titanium surface condition by each grinding process on the cell activity was evaluated by ALP activity of MSC(Mesenchymal Stem Cells). The ALP activity of controlled surface by ELID grinding process using # 2000 wheel was higher than that of other titanium surface. The morphological, chemical properties of machined surface by grinding method was observed using various analytical method.

작업복 소재 직물의 액상 수분 전달 특성 및 표면특성 연구 (Liquid Moisture Management and Surface Properties of the Fabric in Transient Condition)

  • 유신정
    • 한국의류학회지
    • /
    • 제25권1호
    • /
    • pp.61-70
    • /
    • 2001
  • As important factors determining human sensorial comfort, liquid moisture management and surface properties of heat resistant workwear materials were examined. To figure out liquid moisture management properties of the test materials, absorption capacity, rate of absorption, and evaporation properties were assessed. A modified GATS(Gravimetric Absorbency Testing System) was used to measure the liquid moisture accumulation associated with the wicking of liquid moisture from sweating skin. The GATS procedure measures demand wettability of materials to take up liquid in a direction perpendicular to the fabric surface and it was modified to incorporate a special test cell and cover to assess absorption behavior in the presence of evaporation. Fabric stiffness, smoothness, number and the length of surface fibers, and an estimate of the contact area between the skin and fabric surface were measured to characterize the mechanical and surface properties of the test materials. Also an estimate of the force with which a fabric clings to moist skin was made using as wet-cling index.

  • PDF

다양한 코팅 처리에 의한 PEEK 추간체유합보형재의 생체 활성 표면에 관한 연구 (A Study on the bioactive surface modification of PEEK intervertebral fusion cage using various coating techniques)

  • 노수빈;박수지;이문환
    • 한국표면공학회지
    • /
    • 제56권4호
    • /
    • pp.273-282
    • /
    • 2023
  • In this study, the surface of Polyetheretherketone (PEEK) disks was modified to have a hydrophilic surface by applying a coating of Polyethylene glycol (PEG), Hyaluronic acid(HA), and Poly-Dopamine(PDA). The investigation aimed to examine whether the coated surfaces showed enhanced bioactivity for orthopedic applications compared to the pure PEEK. The microstructure, surface characteristics, and wettability of PEEK coated with PEG, HA, and PDA were analyzed using scanning electron microscopy(SEM), FT-IR spectrophotometer, Roughness Measurement System, Micro-Vickers, and Contact angle measurement. The mechanical properties were analyzed using a tensile testing machine, while the MTT assay for cell activity was analyzed using a microplate reader to measure optical density. According to the SEM and FT-IR results, the composition and crystal structure of PEG, HA and PDA coated surface were verified. Also, roughness, hardness, and contact angle were all improved in the coating group compared to the pure PEEK. We checked the HepG2 cell proliferation by using MTT assay on 7th days. In MTT assay results, HepG2 cell proliferation was increased with time, at 7 days, cell viability on discs coated with PDA was significantly higher than pure PEEK, PEG, HA coated group. PDA coated PEEK exhibited the highest surface roughness, hardness, contact angle, and cell activity. The mechanical properties were not affected by the presence of the coating.

Liquid Crystal Orientation Properties on Homogeneous Polymer Surface by Various Alignment Methods

  • Kim, Young-Hwan;Lee, Kang-Min;Kim, Byoung-Yong;Oh, Byeong-Yun;Han, Jeong-Min;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권1호
    • /
    • pp.16-19
    • /
    • 2009
  • We have studied the liquid crystal alignment properties for various alignment methods on the homogeneous polyimide surface. Suitable liquid crystal alignment for one-side alignment cell on the polyimide surface by all alignment method was observed. Highly pre-tilt angle of the NLC for both-side rubbing cell was measured. But, low pre-tilt angle of the NLC for one-side ion beam and UV irradiation cell was observed. We consider that the pre-tilt angle of NLC for one-side ion beam and UV irradiation on the PI surface is lower than that of the PI surface with rubbing. Also, the suitable transmittance-voltage curves for the one-side rubbing TN-LCD on the PI surface with one-side UV irradiation were measured. Also, good response time characteristics of the one-side rubbing TN-LCD on the polyimide surface with one-side UV irradiation can be measured.

Surface characteristics and osteoblastic cell response of alkali-and heat-treated titanium-8tantalum-3niobium alloy

  • Lee, Bo-Ah;Kang, Choong-Hee;Vang, Mong-Sook;Jung, Young-Suk;Piao, Xing Hui;Kim, Ok-Su;Chung, Hyun-Ju;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • 제42권6호
    • /
    • pp.248-255
    • /
    • 2012
  • Purpose: The aim of the present study was to evaluate the biological response of alkali- and heat-treated titanium-8tantalum-3niobium surfaces by cell proliferation and alkaline phosphatase (ALP) activity analysis. Methods: Commercial pure titanium (group cp-Ti) and alkali- and heat-treated titanium-8tantalum-3niobium (group AHT) disks were prepared. The surface properties were evaluated using scanning electron microscopy, energy dispersed spectroscopy and X-ray photoelectron spectroscopy (XPS). The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were also analyzed. The biological response of fetal rat calvarial cells on group AHT was assessed by cell proliferation and ALP activity. Results: Group AHT showed a flake-like morphology microprofile and dense structure. XPS analysis of group AHT showed an increased amount of oxygen in the basic hydroxyl residue of titanium hydroxide groups compared with group cp-Ti. The surface roughness (Ra) measured by a profilometer showed no significant difference (P>0.05). Group AHT showed a lower contact angle and higher surface energy than group cp-Ti. Cell proliferation on group AHT surfaces was significantly higher than on group cp-Ti surfaces (P<0.05). In comparison to group cp-Ti, group AHT enhanced ALP activity (P<0.05). Conclusions: These results suggest that group AHT stimulates osteoblast differentiation.

PDMS와 고분자 전해질 표면을 이용한 간편한 세포 패터닝 방법 (Facile Cell Patterning Based on Selectively Patterned Polydimethylsiloxane (PDMS) and Polyelectrolyte Surface)

  • 정헌호;송환문;황예진;황택성;이창수
    • KSBB Journal
    • /
    • 제24권6호
    • /
    • pp.515-520
    • /
    • 2009
  • This study presented facile method of cell patterning using fabricated PDMS patterns on polyelectrolyte coated surface. This basic principle is the fabrication of functional surface presenting two orthogonal surfaces such as cell adhesive and repellent properties. Cell adhesive surface was firstly fabricated with simple coating of polyelectrolyte multilayer. And then, the desired patterns of PDMS for the prevention of nonspecific binding of cells were transferred onto the previously formed thin film of polyelectrolyte multilayer. Thus, we could prepare novel functional surface simultaneously containing PDMS and polyelectrolyte region. As expected, the PDMS regions showed effective prevention of nonspecific binding of cell and the other region, exposed polyelectrolyte area, provided cell adhesive environment. The height of formed PDMS structure was about 100 nm. Based on this method, cell patterning can be successfully obtained with various pattern shapes and sizes. Therefore, we expect that this simple method will be useful platform technology for the development of cell chip, cell based assay system, and biochip.

Ultraviolet Microscopic Study on Lignin Distribution in the Fiber Cell Wall of BCTMP

  • Yoon, Seung-Lak;Yasuo Kojina
    • 펄프종이기술
    • /
    • 제36권1호
    • /
    • pp.61-66
    • /
    • 2004
  • Bleached chemithermomechanical pulp (BCTMP) was produced from CTMP of Betula maximowicziana Regel by two staged ozone-hydrogen peroxide bleaching in order to improve the optical properties of high yield pulp. This pulp was used for the evaluation of optical properties improvement, chemical characteristics of lignin in fiber and the relationship between lignin and optical properties in fiber cell wall. Hydrogen peroxide treatment improved the brightness, but the post color number (PC No.). There was little improvement on optical properties by ozone treatment, but this could be improved more by using two staged ozone-hydrogen peroxide bleaching. The hydrogen peroxide treatment did not make any change on chemical characteristics of lignin in cell wall, but by ozone treatment, it was found that the non-aromatic conjugated structure was existed in the surface of cell wall, but this could be removed by hydrogen peroxide treatment in two staged ozone-hydrogen peroxide treatment. Therefore, the optical properties was significantly improved, due to the removal of non-aromatic conjugated structure.

Antioxidative Properties of Amaranth Cauline Leaf and Suppressive Effect against CT-26 Cell Proliferation of the Sausage Containing the Leaf

  • Lee, Heejeong;Joo, Nami
    • 한국축산식품학회지
    • /
    • 제38권3호
    • /
    • pp.570-579
    • /
    • 2018
  • The study investigated antioxidative properties and rectal cancer cell inhibition effect of amaranth (Amaranthus cruentus L.) cauline leaves (ACL) to produce the sausage with ACL powder (ACLP). Antioxidative effects of ACLP prepared with different stem lengths (10-45 cm) were evaluated through DPPH, ABTS, reducing power, total phenol, and total flavonoid. Inhibition effect on rectal cancer cells growth was also examined with CT-26 cell. To determine appropriate ACL amounts in sausage formula, response surface methodology was used. The sausages without ACL (control) and the sausage with ACL (ACLP sausage) were the subjected to the examinations of antioxidation, growth inhibition on CT-26, and physicochemical properties (pH and water content). ACLP made from the leaf with 15 cm length stem generally showed the highest antioxidative effect through results of DPPH, ABTS, reducing power, total phenol, and total flavonoid. ACLP also showed inhibition effect on the proliferation of CT-26, depending on concentration of ACLP. The surface response model showed that 4.87 g of ACLP was optimized amount for sausage production. Physicochemical properties between optimized ACLP and control sausages were not significantly different. Higher antioxidative effect of optimized ACLP sausage extract was observed (p<0.05) in antioxidation tests than control sausage extract except for DPPH. Cell viability of CT-26 cells were higher (p<0.05) in ACLP than in control sausage extracts. These results indicate that ACLP has functional effects on antioxidation activity and growth inhibition on CT-26 cell, and thus, it should be useful as a supplement in sausage, which may some effect as ACLP itself.

PC1D 시뮬레이션을 이용한 결정질 실리콘 태양전지의 도핑 프로파일 모델링 (The Doping Profile Modeling of Crystalline Silicon Solar Cell with PC1D simulation)

  • 최성진;유권종;송희은
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.149-153
    • /
    • 2011
  • The PC1D is widely used for modeling the properties of crystalline silicon solar cell. Optimized doping profile in crystalline silicon solar cell fabrication is necessary to obtain high conversion efficiency. Doping profile in the forms of a uniform, gaussian, exponential and erfc function can be simulated using the PC1D program. In this paper, the doping profiles including junction depth, dopant concentration on surface and the form of doping profile (gaussian, gaussian+erfc function) were changed to study its effect on electrical properties of solar cell. As decreasing junction depth and doping concentration on surface, electrical properties of solar cell were improved. The characteristics for the solar cells with doping profile using the combination of gaussian and erfc function showed better open-circuit voltage, short-circuit current and conversion efficiency.

  • PDF