• 제목/요약/키워드: Ceiling unit

검색결과 58건 처리시간 0.03초

천장형 유닛을 설치한 교실 내의 인체 주변 온열환경에 관한 실측연구 (A Field Measuring Study on the Thermal Environment of Human Surrounding in the Classroom Equipped with Ceiling Unit)

  • 조성우;임영빈;이경희
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.240-246
    • /
    • 2006
  • This paper performed to investigate on vertical temperature distribution, effective draft temperature (ETD) and PMV (Predicted Mean Vote) in the classroom, which is located YangSan city (Kyungsangnam-Do), Korea, is equipped with ceiling unit. The vertical temperature difference between F.L+10 cm (ankle) and F.L+120 cm (neck) of a measuring point which is adjacent corridor in the classroom showed about $1^{\circ}C$ but of measuring point which is adjacent outdoor expressed up to $4^{\circ}C$, The effective draft temperature (ETD) is -2.3 and -0.52 and 0.67 at near ceiling unit but is 1.2 and 3.3 at far from ceiling unit. The PMV of total classroom showed the range of 'Cold' and 'Slightly Cold.' Therefore, to achieve comfort condition in the classroom is equipped with ceiling unit, the location of ceiling unit and discharge angle and discharge distance from ceiling unit are very important elements.

교실 천장형 Unit의 위치에 따른 온열환경 평가 연구 (A Study on the Evaluation of Thermal Environment according to the Location of Ceiling Type Unit in Classroom)

  • 조성우;최정민;손영환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.135-140
    • /
    • 2005
  • Installation of ceiling type unit is achieved by one of efforts for agreeable classroom environment embodiment along with economic growth. But research about changing the position of ceiling type unit is lacking in present. Therefore, this thesis is to study the thermal environment of 5 different position cases of ceiling type, namely Case A, B, C, D, E. Here, Case C is the case that has the position of ceiling type center of the classroom and the other 4 alternatives are 0.7 m away from the Case C according to x and z axis. In this thesis temperature distributions, air current distribution, heat amenities such as PMV of occupants are analyzed as the environmental factors. Through these factors, Case C and Case D are the better position alternatives than the alternatives of Case A, Case B and Case E because the latter cases the air current reaches directly to indoor occupants so that occupants feel chilly. This thesis has a conclusion under the condition of only one inlet air temperature and seat arrangement. But afterwards more inlet air condition and seat arrangement must be considered.

  • PDF

실링 유닛 장착효과를 고려한 MR16 LED 조명등 방열설계 (Thermal Design of a MR16 LED Light with the Effects of Ceiling Unit Mount)

  • 황순호;이영림
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3141-3147
    • /
    • 2010
  • LED 조명등의 효율 및 수명을 단축시키는 가장 중요한 원인은 정션온도 상승이며, 이를 해결하기 위해 고효율 방열 패키징, 고전도율 소재 개발, 접촉저항 개선 및 히트싱크 최적화 등과 같이 다양한 방열성능 향상 연구가 이루어지고 있다. 하지만 지금까지의 대부분의 연구는 LED 조명등이 단지 대기 중에 노출되었다고 가정하였기 때문에 실제 실링 유닛과 함께 천장에 장착되었을 때의 방열성능은 아직 보고되지 않고 있다. 따라서, 본 연구에서는 MR16 LED 조명등을 이용하여 실제 설치조건에 따른 정션온도 변화를 규명하고 이를 통한 더욱 정확한 LED 조명등 수명 및 효율 예측을 이루고자 하였다.

신문광고에 나타난 아파트 계획요소의 변화에 관한 연구 - 분양가 자율화 전.후의 비교를 중심으로 - (A Study on the Changes of Planning Factors of Apartment Houses in Newspaper Advertisements - Focused on the comparison in times of deregulation of the price ceiling -)

  • 박주연;김유희;유창균;조용준
    • 한국주거학회논문집
    • /
    • 제17권6호
    • /
    • pp.73-81
    • /
    • 2006
  • This study focused on the fact that changes of policies have influence on housing culture of Korea and analyzed changes in apartment houses planning since the deregulation of the price ceiling through newspaper advertisement. The research compared and analyzed advertisements of apartment houses sales appeared in the 'Gwangju Il-Bo' daily newspaper from 1990 to 2003 by planning factors. : The results are as follows. Reliability and economy were important factors in deciding apartment before the deregulation of the price ceiling policy, but as apartment houses were merchandised after the deregulation of the price ceiling policy, brand of enterprise and image of apartment houses were highlighted more. In the environment of apartment complex, the concerns of location after the deregulation of the price ceiling policy were more increased than before its policy and it means emphasis on living environment for better life. The apartment housing unit and building showed change of the apartment housing unit plan considering residents, high quality of interior design and high-tech and differentiation of equipment since the deregulation of the price ceiling policy. The ground space has been parked or afforested and the underground space is used for parking lot as a part of environment-friendly in the apartment complex planning. The deregulation of the price ceiling policy made brand, image, high-grade and differentiation, and got many changes in the planning side of the apartment sales advertisement.

기능성 모듈이 적용된 천장 매립식 냉난방 유닛의 유동특성 평가에 관한 연구 (A Study on the Evaluation of Flow Characteristics of Heating and Cooling Unit Installed within Ceiling with Functional Modules)

  • 이홍철;황인주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1131-1136
    • /
    • 2006
  • In this study, an experimental and numerical analysis on the flow characteristics of heating and cooling unit installed within ceiling with functional modules was carried out. And the flow characteristics of the heating and cooling unit was investigated with the main parameters such as each filter and inside structure. The experimental results show the possibility of medium filter application. And the numerical results show that the effect of improved inside structure of heating-cooling and air-conditioning unit on flow distribution.

  • PDF

PIV 유동 계측을 통한 천장형 실내기의 최적 제어 설계 (Optimal Flow Control of Ceiling Type Indoor Unit by PIV Measurements)

  • 성재용;안광협;이기섭;최호선;이인섭
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1042-1050
    • /
    • 2003
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated to determine the design parameters for the optimal flow control. The flow was measured by a PIV(particle image velocimetry) system and an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number. This similarity is generally used in cases where the forced convection has similar magnitude of the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, experimental results show that 30$^{\circ}$is an optimal angle to avoid re-suction flows without significant increase in flow noise. Temperature distribution measured in the environmental chamber ensures the increased thermal comfort when compared to the case, 60$^{\circ}$angle. At the optimal angle, applying open/close control gives rise to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for thermal comfort.

천장형 실내기의 기류 가시화를 통한 최적 제어 설계 (Design of Optimal Vane Control for Ceiling Type Indoor Unit by PIV measurements)

  • 성재용;안광엽;이기섭;최호선;박승철;이인섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.533-536
    • /
    • 2002
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated using a PIV(particle image velocimetry) system For the PIV measurements, an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number, which is generally used in case that the forced convection has the similar magnitude as the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, the experimental results show that it should be less than $30^{\circ}$ to avoid re-suction flows which decrease the performance of the air-conditioner. At the vane angle of $30^{\circ}$, applying open/close control gives nae to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for the thermal comfort.

  • PDF

천장 카세트형 냉·난방기에 의해 형성되는 학교 교실의 실내 열환경 및 공기환경의 개선에 대한 연구 (A Study on the Improvement of Indoor Thermal and Air Environment Made by Ceiling Cassette Type Cooling and Heating Unit in Classrooms)

  • 장현재;이하영
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.141-148
    • /
    • 2012
  • Ceiling cassette type air conditioner has been a main stream as a heating/cooling system recently in school, Korea. In this study, indoor thermal environments made by ceiling cassette type air conditioner were investigated by CFD simulation. Concentrations of $CO_2$ were investigated by a field measurement. Indoor thermal environment with the velocity inlet angle of $45^{\circ}$ from the ceiling in heating season was very ununiform so that thermal area was divided into two parts those the one is window side which is cold, and the other is corridor side which is hot. In cooling season under the same condition, there are areas too hot or too cold. If the velocity inlet angle is set in $30^{\circ}$ from the ceiling, indoor thermal environments was improved greatly in cooling season and heating season, too. Also, from the field measurement of $CO_2$ concentrations, it was suggested to install ventilators with proper air volume considered the number of class students.

주거 공간에서의 룸 에어컨디셔너 실내기 유형에 따른 온열쾌적성 및 에너지성능 평가 (Evaluation of Thermal Comfort and Energy Efficiency According to Indoor-Unit Types of Room Air-Conditioner in Housing Space)

  • 석호태;김동우;양정훈
    • 한국주거학회논문집
    • /
    • 제20권4호
    • /
    • pp.19-29
    • /
    • 2009
  • The purpose of this study is to evaluate the air diffusion performance of a range of indoor units for room airconditioners; the wall-mounted type, floor-standing type, and ceiling-mounted type. These types of units, which have been widely used in housing spaces, will be studied with respect to thermal comfort and the energy performance using CFD analysis. In this study, current air conditioning status and related problems in housing spaces are examined, and a CFD analysis is performed in order to compare and analyze the thermal comfort and energy efficiency across each type of indoor-unit using the PMV, ADPI, EUC and FCEI indexes. The analysis results collectively considering thermal comfort and energy performance indicated that the ceiling-mounted type 4-way indoor unit showed the best diffusion performance in terms of thermal comfort, and had the second best diffusion performance in terms of energy performance after the wall-mounted type under certain conditions.