• Title/Summary/Keyword: Ceiling unit

Search Result 58, Processing Time 0.031 seconds

A Field Measuring Study on the Thermal Environment of Human Surrounding in the Classroom Equipped with Ceiling Unit (천장형 유닛을 설치한 교실 내의 인체 주변 온열환경에 관한 실측연구)

  • Cho Sung-Woo;Im Young-Bin;Lee Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.240-246
    • /
    • 2006
  • This paper performed to investigate on vertical temperature distribution, effective draft temperature (ETD) and PMV (Predicted Mean Vote) in the classroom, which is located YangSan city (Kyungsangnam-Do), Korea, is equipped with ceiling unit. The vertical temperature difference between F.L+10 cm (ankle) and F.L+120 cm (neck) of a measuring point which is adjacent corridor in the classroom showed about $1^{\circ}C$ but of measuring point which is adjacent outdoor expressed up to $4^{\circ}C$, The effective draft temperature (ETD) is -2.3 and -0.52 and 0.67 at near ceiling unit but is 1.2 and 3.3 at far from ceiling unit. The PMV of total classroom showed the range of 'Cold' and 'Slightly Cold.' Therefore, to achieve comfort condition in the classroom is equipped with ceiling unit, the location of ceiling unit and discharge angle and discharge distance from ceiling unit are very important elements.

A Study on the Evaluation of Thermal Environment according to the Location of Ceiling Type Unit in Classroom (교실 천장형 Unit의 위치에 따른 온열환경 평가 연구)

  • Cho, Sung-Woo;Choi, Jeong-Min;Son, Young-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.135-140
    • /
    • 2005
  • Installation of ceiling type unit is achieved by one of efforts for agreeable classroom environment embodiment along with economic growth. But research about changing the position of ceiling type unit is lacking in present. Therefore, this thesis is to study the thermal environment of 5 different position cases of ceiling type, namely Case A, B, C, D, E. Here, Case C is the case that has the position of ceiling type center of the classroom and the other 4 alternatives are 0.7 m away from the Case C according to x and z axis. In this thesis temperature distributions, air current distribution, heat amenities such as PMV of occupants are analyzed as the environmental factors. Through these factors, Case C and Case D are the better position alternatives than the alternatives of Case A, Case B and Case E because the latter cases the air current reaches directly to indoor occupants so that occupants feel chilly. This thesis has a conclusion under the condition of only one inlet air temperature and seat arrangement. But afterwards more inlet air condition and seat arrangement must be considered.

  • PDF

Thermal Design of a MR16 LED Light with the Effects of Ceiling Unit Mount (실링 유닛 장착효과를 고려한 MR16 LED 조명등 방열설계)

  • Hwang, Soon-Ho;Lee, Young-Lim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3141-3147
    • /
    • 2010
  • The most important cause for shortening LED lighting efficiency and life is the junction temperature rises and, to solve this problem, various studies such as thermally efficient packaging, highly conductive material development, contact resistance improvement or heat sink optimization have been studied. However, most studies so far assumed that the LED lights are in the atmosphere, and thermal performance has not been therefore reported when the LED lights are mounted on the ceiling with ceiling unit. Thus, this study investigates the variation of junction temperature of the MR16 LED light under actual installation conditions and more accurate thermal design for the efficiency and life of LED lights is therefore achieved.

A Study on the Changes of Planning Factors of Apartment Houses in Newspaper Advertisements - Focused on the comparison in times of deregulation of the price ceiling - (신문광고에 나타난 아파트 계획요소의 변화에 관한 연구 - 분양가 자율화 전.후의 비교를 중심으로 -)

  • Park, Joo-Yeon;Kim, Yu-Hee;Yoo, Chang-Geun;Cho, Yong-Joon
    • Journal of the Korean housing association
    • /
    • v.17 no.6
    • /
    • pp.73-81
    • /
    • 2006
  • This study focused on the fact that changes of policies have influence on housing culture of Korea and analyzed changes in apartment houses planning since the deregulation of the price ceiling through newspaper advertisement. The research compared and analyzed advertisements of apartment houses sales appeared in the 'Gwangju Il-Bo' daily newspaper from 1990 to 2003 by planning factors. : The results are as follows. Reliability and economy were important factors in deciding apartment before the deregulation of the price ceiling policy, but as apartment houses were merchandised after the deregulation of the price ceiling policy, brand of enterprise and image of apartment houses were highlighted more. In the environment of apartment complex, the concerns of location after the deregulation of the price ceiling policy were more increased than before its policy and it means emphasis on living environment for better life. The apartment housing unit and building showed change of the apartment housing unit plan considering residents, high quality of interior design and high-tech and differentiation of equipment since the deregulation of the price ceiling policy. The ground space has been parked or afforested and the underground space is used for parking lot as a part of environment-friendly in the apartment complex planning. The deregulation of the price ceiling policy made brand, image, high-grade and differentiation, and got many changes in the planning side of the apartment sales advertisement.

A Study on the Evaluation of Flow Characteristics of Heating and Cooling Unit Installed within Ceiling with Functional Modules (기능성 모듈이 적용된 천장 매립식 냉난방 유닛의 유동특성 평가에 관한 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1131-1136
    • /
    • 2006
  • In this study, an experimental and numerical analysis on the flow characteristics of heating and cooling unit installed within ceiling with functional modules was carried out. And the flow characteristics of the heating and cooling unit was investigated with the main parameters such as each filter and inside structure. The experimental results show the possibility of medium filter application. And the numerical results show that the effect of improved inside structure of heating-cooling and air-conditioning unit on flow distribution.

  • PDF

Optimal Flow Control of Ceiling Type Indoor Unit by PIV Measurements (PIV 유동 계측을 통한 천장형 실내기의 최적 제어 설계)

  • Sung, Jae-Yong;An, Kwang-Hyup;Lee, Gi-Seop;Choi, Ho-Seon;Lee, In-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1042-1050
    • /
    • 2003
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated to determine the design parameters for the optimal flow control. The flow was measured by a PIV(particle image velocimetry) system and an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number. This similarity is generally used in cases where the forced convection has similar magnitude of the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, experimental results show that 30$^{\circ}$is an optimal angle to avoid re-suction flows without significant increase in flow noise. Temperature distribution measured in the environmental chamber ensures the increased thermal comfort when compared to the case, 60$^{\circ}$angle. At the optimal angle, applying open/close control gives rise to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for thermal comfort.

Design of Optimal Vane Control for Ceiling Type Indoor Unit by PIV measurements (천장형 실내기의 기류 가시화를 통한 최적 제어 설계)

  • Sung Jaeyong;An Kwang Hyup;Lee Gi Seop;Choi Ho Seon;Park Seung-Chul;Lee In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.533-536
    • /
    • 2002
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated using a PIV(particle image velocimetry) system For the PIV measurements, an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number, which is generally used in case that the forced convection has the similar magnitude as the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, the experimental results show that it should be less than $30^{\circ}$ to avoid re-suction flows which decrease the performance of the air-conditioner. At the vane angle of $30^{\circ}$, applying open/close control gives nae to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for the thermal comfort.

  • PDF

A Study on the Improvement of Indoor Thermal and Air Environment Made by Ceiling Cassette Type Cooling and Heating Unit in Classrooms (천장 카세트형 냉·난방기에 의해 형성되는 학교 교실의 실내 열환경 및 공기환경의 개선에 대한 연구)

  • Chang, Hyun-Jae;Lee, Ha-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.141-148
    • /
    • 2012
  • Ceiling cassette type air conditioner has been a main stream as a heating/cooling system recently in school, Korea. In this study, indoor thermal environments made by ceiling cassette type air conditioner were investigated by CFD simulation. Concentrations of $CO_2$ were investigated by a field measurement. Indoor thermal environment with the velocity inlet angle of $45^{\circ}$ from the ceiling in heating season was very ununiform so that thermal area was divided into two parts those the one is window side which is cold, and the other is corridor side which is hot. In cooling season under the same condition, there are areas too hot or too cold. If the velocity inlet angle is set in $30^{\circ}$ from the ceiling, indoor thermal environments was improved greatly in cooling season and heating season, too. Also, from the field measurement of $CO_2$ concentrations, it was suggested to install ventilators with proper air volume considered the number of class students.

Evaluation of Thermal Comfort and Energy Efficiency According to Indoor-Unit Types of Room Air-Conditioner in Housing Space (주거 공간에서의 룸 에어컨디셔너 실내기 유형에 따른 온열쾌적성 및 에너지성능 평가)

  • Seok, Ho-Tae;Kim, Dong-Woo;Yang, Jeong-Hoon
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.19-29
    • /
    • 2009
  • The purpose of this study is to evaluate the air diffusion performance of a range of indoor units for room airconditioners; the wall-mounted type, floor-standing type, and ceiling-mounted type. These types of units, which have been widely used in housing spaces, will be studied with respect to thermal comfort and the energy performance using CFD analysis. In this study, current air conditioning status and related problems in housing spaces are examined, and a CFD analysis is performed in order to compare and analyze the thermal comfort and energy efficiency across each type of indoor-unit using the PMV, ADPI, EUC and FCEI indexes. The analysis results collectively considering thermal comfort and energy performance indicated that the ceiling-mounted type 4-way indoor unit showed the best diffusion performance in terms of thermal comfort, and had the second best diffusion performance in terms of energy performance after the wall-mounted type under certain conditions.