• 제목/요약/키워드: Ceiling temperature

검색결과 159건 처리시간 0.025초

하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가 (Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer)

  • 김상진;김은수;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

천장개구부를 갖는 정사각형 밀폐공간내의 자연대류-복사 열전달에 관한 연구 (A Study on the natural Convection and Radiation in a Rectangular Enclosure with Ceiling Vent)

  • 박찬국;추병길;김철;정재환
    • 한국가스학회지
    • /
    • 제2권1호
    • /
    • pp.28-39
    • /
    • 1998
  • 본 연구에서는 $20\%$ 천장개구부가 있는 정사각형 밀폐공간내의 순수자연대류와 자연대류 -복사가 고려된 복합열전달을 순차해석과 실험을 통하여 비교 분석하였다. 수치해석은 순수자연대류에 대하여 SIMPLE 알고리즘을 사용하였고, 복사열전달에 대해서는 S-N 구분 종좌표법을 이용하였으며 난류유동의 경계조건은 벽함수를 적용하였다. 실험은 수치해석의 결과와 비교하기 위하여 동일한 조건에 대하여 수행되었다. 그 결과 순수자연대류와 복합열전달의 유동장, 온도장의 형상은 유사한 유선함수를 보이고 있으며, 유동가시화를 통한 실험결과와 잘 일치하고 있음을 보여준다. 수치해석과 실험의 온도분포를 비교한 결과 평균 $8.5\%$의 오차를 보였다.

  • PDF

외기에 면한 초고층 아파트 발코니 천정 내부결로 예측 (Forecast on Internal Condensation at Balcony Ceiling of Super-high Apartment Building Faced with Open Air)

  • 최윤기;안재봉
    • 한국건설관리학회논문집
    • /
    • 제4권4호
    • /
    • pp.155-163
    • /
    • 2003
  • 최근 들어 주거공간의 기능만족과 효율성 확보를 위해 외기측에 면한 발코니 부위를 확장하는 사례가 늘어나고 있으며 특히, 최상층에 위치한 확장형 주거공간의 경우 외벽에 설치된 AL Curtain wall상부 외벽복합 Panel 이 완전 기밀하지 않음으로 인해 천정 상부측으로 낮은 외기온의 이동에 의한 실온과의 온도차에 의해 내부결로의 발생 가능성을 전혀 배제할 수는 없는 상황이다. 본 연구는 외기에 면한 초고층 아파트 최상층부의 발코니 천장내부에 있는 H-Beam(내화피복+단열재 구성)파 Parapet부위 내부결로 발생가능성에 대한 예측을 해 봄으로써 해당 공간거주자의 쾌적한 환경 만족 및 불안을 해소하는데 그 목적이 있다. 외주부를 구성하고 있는 Curtain wall Stone panel 또는 슬래브 바닥하부 등의 열적 취약공간에 대해 2차원 정상상태(온도평형) 열전도해석 Program을 이용, 온도예측과 온도분포해석을 통해 해당부위의 수증기압 분포에 따른 내부결로 예측을 실시하였다.

밀폐공간에서의 화재에 의한 연기의 유동 이론 (The Theory of Smoke Movement by a Fire in an Enclosure)

  • 노재성;유홍선
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1996년도 학술발표회
    • /
    • pp.5-9
    • /
    • 1996
  • In foreign country such as U.S.A and Japan, considerable research has been done regarding the spread of smoke in room of fire involvement by using computer. But, in our country it has not been. So, this paper presents a detailed qualitative description of phenomena which occures during typical fire scenarios through numerical analysis. This research, in the view of field model, is focused on finding out the smoke movement and temperature distribution. And it is planned to analyze governing equation including smoke diffusion equation by numerical analysis with finite volume method and non-staggered grid system. The SIMPLE method for pressure-velocity couple and power-law scheme for convection terms are used. It shows that a plume is formed, hot plume is formed, hot plume gases impinge on the ceiling and they spread across it. then, it eventually reaches the bounding walls of the enclosure. It takes 60s for smoke to fill the enclosure.

  • PDF

Experimental Study on Living Room Lighting Environment for Residential Activities

  • Kim, Hyun-Ji;Woo, Seong-Jun;Kim, Hoon
    • 조명전기설비학회논문지
    • /
    • 제27권1호
    • /
    • pp.10-16
    • /
    • 2013
  • This study performed a subjective evaluation of the Semantic Differential (SD) method for living room activities to evaluate the living room lighting environment and investigated the relationship between these through luminance distribution in the space. As a result, three factors-"lightness", "emotion" and "calmness"-have been grouped together. According to the analysis of experimental variables, difference has been observed depending on color temperature, the dimming of the ceiling & cove lights and the use of down lights and a bracket. 'Conversation with Family', 'Having Fun with Family', 'Entertaining Guests' and 'Reading a Book or Newspaper' requires "lightness". In terms of "emotion"-centered activities, 'Watching TV' is the highest, but all three factors are related. In terms of "calmness"-centered activities, 'Relaxing' is the highest.

부분밀폐공간내에서 화재로 야기되는 열 및 유동특성에 관한 연구 (A Study of Thermal and flow Characteristics Induced by Fire in a Partial Enclosure)

  • 박희용;한철희;박경우
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1288-1300
    • /
    • 1994
  • Mathematical modeling and numerical calculation on the flow and thermal characteristics induced by fire in a partial enclosure are performed. The solution procedures include the Shvab-Zeldovich approximation for the physical transport equations, low Reynolds number k-.epsilon. model for the turbulent fluid flow and Discrete Ordinate method(DOM) to calculate the radiative heat transfer. PMMA(Polymethylmethacrylate) is adopted as a solid fuel. Two different cases are considered : combustions with and without gas radiation occuring in a open cavity for variable pyrolyzing location of PMMA. When the fire source is located at the left-wall, the flow region of flame gas is limited at the left-wall and ceiling and recirculation region of inlet gas is formulated at neat the floor. In case of neglecting the radiative heat transfer, more large flame size and higher temperature is predicted. It is essential to consider the radiative heat transfer for analysis of fire phenomenon.

혼합환기와 하향 압출환기시스템이 동반된 KBS공개홀의 온열환경 평가 (Thermal environment evaluation of KBS open hall with mixing ventilation and downward displacement ventilation systems)

  • 권용일;권순석
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.147-154
    • /
    • 1998
  • This study was carried out for evaluating the interior thermal environment in KBS Open hall with large ceiling height and large space. Ventilation systems of KBS Open hall have combined mixing ventilation and downward displacement ventilation system. Temperature and velocity was measured 130 locations with low level(0.1m), mid level(0.6m) and high level(1.1m). But relative humidity was measured at 15 locations. The subjective thermal sensation was made an inquiry of occupancy at the location measured physical elements.

  • PDF

Foodborne Pathogen Reduction을 위한 항균제의 새로운 Delivery System인 Aerosolization

  • 오세욱;강동현
    • 식품기술
    • /
    • 제18권1호
    • /
    • pp.91-98
    • /
    • 2005
  • Aims: As a preliminary experiment on new sanitizer delivery tools, the efficacy of aerosolizedsanitizer on foodborne pathogens was investigated in larger model chamber system.Methods: Peroxyacetic acid and hydrogen peroxide were aerosolized in a model system againstartificially inoculated target microorganisms on laboratory media. Cultures of 4 different foodborne pathogens were inoculated and affixed onto 3 different heights (bottom, wall, and ceiling), and 3different orientations (face-down, vertical, and face-down) inside a commercial semi-trailer cabinet(14.6 x 2.6 x 2.8 m). Sanitizer was aerosolized into 2 m droplet size fog and treated for 1 h atambient temperature.Results: Populations of Bacillus cereus, Listeria innocua, Staphylococcus aureus, and Salmonellatyphimurium were reduced by an average of 3.09, 7.69, 6.93 and 8.18 log units per plate, respectively.Interestingly, L. innocua, Staph. aureus, and Salm. typhimurium showed statistically not different (P$\leq$ 0.05) reduction patterns relative to height and orientation that were never expected in a sprayingsystemConclusion and significance: Aerosolized sanitizers diffuse like gaseous sanitizers, so it has greatpotential for use in commercial applications.

  • PDF

건물내 화재에 의한 연소가스 거동 예측에 관한 연구 (A Study on the Prediction of Combustion Gas Behavior Induced by Fire in a Building)

  • 박희용;박경우
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.267-281
    • /
    • 1994
  • The Combustion gas behavior induced by fire in a building is numerically investigated. The typical building for this analysis is partially divided by a vertical baffle projecting from the ceiling. The solution procedure includes the low Reynolds number ${\kappa}-{\varepsilon}$ model for the turbulent flow and the discrete ordinates method is used for the calculation of radiative heat transfer equation. The effects of the location and size of fire source and baffle length on velocity and temperature distributions, species mass fraction and flame location are analyzed. As the results of this study, it is found that the case when the fire source is located at the vertical wall is more dangerous than at the bottom wall in view of the combustion products and flame location. It is also found that the radiation effect cannot be neglected in analyzing the building in fire.

  • PDF

수직갱이 설치된 터널내 화재시 연기거동에 관한 실험적 연구 (An Experimental Study of Smoke Movement in Tunnel Fires with a Vertical Shaft)

  • 이성룡;유홍선;김충익
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.135-141
    • /
    • 2004
  • The present paper concerns a smoke movement in a tunnel fire with a vertical shaft. The model tunnel measured 13.4m long, 0.4m wide and 0.4m high. The cross section is 1: 20 of a full scale tunnel. Ethanol was used as a fuel. The fire size in model tests varied from 1.35 kW to 13.37 kW, which corresponds to full scale fires of 2.41 to 23.91 MW. Smoke front velocity and temperatrue were decreased due to the vertical shaft install. Temperature was reduced maximum about 2$0^{\circ}C$ at ceiling and about 23$^{\circ}C$ at vertical position. CO concentration was reduced as the vent width widened. When vent width was more than 15 cm, CO concentration was not reached 100 ppm. Descent degree of the smoke layer was confirmed through the visualization.