• 제목/요약/키워드: Ceiling temperature

검색결과 159건 처리시간 0.022초

일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가 (Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool)

  • 박해동;박현희;신정아;김태호
    • 한국환경보건학회지
    • /
    • 제36권5호
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

공동을 이용한 초음속 연소의 수치적 연구 (Numerical Simulation Study on Supersonic Combustion using the Cavity)

  • 정은주;정인석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.255-260
    • /
    • 2005
  • To achieve efficient combustion within a manageable length, a successful fuel injection scheme must provide rapid mixing between the fuel and airstreams. The aim of the present numerical research is to investigate the flame holding and combustion enhancement. Additional fuel into the cavity prevents shear flow impingement on the trailing edge of the cavity. The high temperature freestream flow mixes with the cold hydrogen fuel that is injected into the cavity and raises the fuel temperature remarkably and become to start combustion. The high pressure in the cavity due to the cavity structure and combustion leads the hydrogen fuel to upstream. The shock in the cavity to be generated by the fuel injection joins together and reflects off the ceiling wall. This makes high pressure and low mach number region and makes a small recirculation in this region. This high stagnation temperature is nearly recovered in the shear layer in front of the cavity and leads to start combustion. In the downstream of the cavity, the wall pressure drops significantly. This means that the combustion phenomenon is diminished. Because fuel lumps at the trailing edge of the cavity then it spreads after the cavity so, in this region there is a strong expansion.

  • PDF

실내 3D 입체 면광원 조명연출에 관한 감성평가 모형 연구 (Sensibility Evaluation Model Research as to The Three-dimensional Surface Light Source set In The Interior)

  • 이진숙;박지영;정찬웅
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.14-26
    • /
    • 2015
  • This study has been conducted so as to analyse user's sensibility on lighting method, correlated color temperature and illumination by composing surface light source, which was projected onto a unit side of interior wall, ceiling and floor. 1) As an analyzed results of the sensibility images, it showed that the "snug & tender" value had got higher when the correlated color temperature got lower. And the "energetic, cheerful" value had got higher when the level of illuminance got lower. Furthermore, the "unusual, unique" showed higher value on the illuminated floor circumstance. Finally, the higher correlated color temperature had been, "energetic, cheerful" value also got higher. 2) As a result of multi-regression analysis, it was found that 3000K and 100lx had the biggest influence on 'snug' image while 5,500K, 500lx had the biggest influence on 'energetic' image. In addition, it was found that the illuminated floor had a big influence on 'unusual' image while 500lx had the biggest influence on 'refined' image.

차폐막이 있는 밀폐공간 내에서의 난류 자연대류 - 복사열전달에 관한 연구 (A Study on the Turbulent Natural Convection - Radiative Heat Transfer In a Partitioned Enclosure)

  • 박경우;이주형;박희용
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2738-2750
    • /
    • 1994
  • The Effects of radiative heat transfer on turbulent flow in a partitioned enclosure is studied numerically. The enclosure is partially divided by a thin, poorly conducting vertical divider projecting from the ceiling of the enclosure. The low Reynolds number $k-{\epsilon}$ model is adopted to calculate the turbulent flow field. The solutions to the radiative transfer equations are obtained by the discrete ordinates method(DOM). This method is based on control volume method and is compatible with the SIMPLER algorithm used to solve the momentum and energy equations. The effects of optical thickness and Planck number on the flow, temperature fields and heat transfer rates are investigated for a moderate Rayleigh number($=10^9$). The changes in buoyant flow fields and temperature distributions due to the variation of baffle length are also analyzed. From the predictions, radiant heat exchange between the baffle and the sidewalls strongly influences the temperature distribution in the baffle and its vicinity and total heat transfer increases as the optical thickness and the baffle length decrease. It is possible to neglect the radiative heat transfer effect when Planck number is over one.

에너지를 함유한 선 폴리머인 Prepolymer(GDNPF) 제조 공정 연구 (A study on the polymerization of energetic prepolymer(GDNPF))

  • 전용구;김진석
    • 한국군사과학기술학회지
    • /
    • 제8권2호
    • /
    • pp.67-76
    • /
    • 2005
  • We synthesized an energetic prepolymer(glycidyl dinitro propyl formal, GDNPF) for plastic-bonded explosive and measured its thermodynamic parameters. Glycidyl dinitro propyl formal(GDNPF) as an energetic monomer was epoxidized from allyl-2,2-dinitro propyl formal which is reacted with dinitro propyl alcohol and excess allyl alcohol, and then energetic polymer of GDNPF was polymerized by cationic ring opening polymerization. Thermodynamic parameters were obtained from the ceiling temperature($T_c$) values of 1 mole monomer at reaction temperature. We varied feed rate of monomer, concentration of initiator and monomer to control molecular weight and polydispersity of prepolymer (GDNPF). The activated monomer polymerization has been executed with precisely controlled feed of GDNPF monomer to reactor in the complex state catalyst generated by $BF_3{\cdot}(C_3H_5)_2$ and 1,4-butanediol in $C_2H_4Cl_2$. Number average molecular weight(Mn), polydispersity(Pd), hydroxy number and glass transition temperature($T_g$) of prepolymer(GDNPF) were $2,500{\sim}3,000,\;1.2{\sim}1,3,\;0.6{\sim}0.8eq/kg\;and\;-20{\sim}-25^{\circ}C$ respectively.

겨울철 냉기를 이용한 벼의 저온저장 (II) - 빈상부 쿨링시스템을 이용한 냉각 벼의 저온저장 특성 - (Low Temperature Storage of Rough Rice Using Cold-Air in Winter (II) - Low Temperature Storage Characteristics of Rough Rice Using a Cooling System in the Top of a Bin -)

  • 이재석;홍현기;리혁;박종수;함택모;한충수
    • Journal of Biosystems Engineering
    • /
    • 제32권1호
    • /
    • pp.13-19
    • /
    • 2007
  • Storage rough rice in low temperature using the winter cold air avoids rough rice temperature increase which happens from early May, and this is possible by installing a cooling system in the top of a bin, the room between top rice level and bin ceiling. The research objective is to establish low temperature rough rice storage technique, furnishing winter cold air to rough rice, by investigating the cooling system potential of maintaining low rough rice temperature and by analyzing rough rice storage characteristics over a storage period. The rough rice storage characteristics were evaluated from January to August 2003, using a storage and dry bin of 400-ton capacity. Results of this research are as follows: Cooling bin using the cooling system in the top of the bin maintained the rice temperature less than 15$^{\circ}C$ in entire portions in August. Moisture contents and germination rates of rough rice were decreased over the storage period, on the other hand, the rough rice stored in the ambient temperature bin had relatively lower moisture contents and germination rates to compare with the bin using winter cold air. Crack ratio and acid value of brown rice in the ambient temperature bin storage had increased more than the cooling bin storage. The result indicates that the storage bin using winter cold air and the cooling system maintains moisture content and germination of rice, minimizes cracked kernel and acid value, and preserves rice quality as well.

천장제트기류에 대한 국내 정온식 열감지기의 작동온도 및 반응시간지수(RTI)에 관한 DB 구축 (DB Construction of Activation Temperature and Response Time Index for Domestic Fixed-temperature Heat Detectors in Ceiling Jet Flow)

  • 윤가영;한호식;문선여;박충화;황철홍
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.35-42
    • /
    • 2020
  • 성능위주 소방설계(PBD)의 안전성 평가 과정에서 화재모델링의 신뢰성 확보를 위해서는 화재감지기 작동시간의 정확한 예측성능이 요구된다. 본 연구는 대표적 화재모델인 FDS에 적용되는 정온식 열감지기의 주요 입력인자인 감지기 작동온도와 RTI의 측정을 목표로 한다. 이를 위해 화재감지기 실험 장치인 Fire detector evaluator (FDE)가 적용되었으며, 제품 인지도 조사를 통해 선정된 국내 10종의 정온식 감지기가 고려되었다. 결과적으로 감지기의 제조사별로 작동온도와 RTI는 상당한 차이가 있는 것으로 확인되었으며, 측정된 DB가 적용된 FDS의 감지기 작동시간은 보다 정확한 예측이 가능함을 확인하였다. 최종적으로 신뢰성이 확보된 정온식 열감지기의 작동온도와 RTI의 DB가 제공되었다.

쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과 (Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof)

  • 송봉근;김경아;박경훈
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

RFID 기반 냉동창고 시스템의 적재위치 관리 방안 (An Approach for Managing Storage Locations in RFID-Based Cold-Storage Warehouse System)

  • 문미경;최봉준
    • 한국정보통신학회논문지
    • /
    • 제15권9호
    • /
    • pp.1971-1978
    • /
    • 2011
  • 기존의 RFID (Radio Frequency Identification) 기반 냉동창고 시스템에서는 cold room 입구에 RFID 리더기를 설치하여 물품이 인식될 때 단지 그곳에 적재되는 것으로 인식하였다. 그러나 이러한 방법으로는 다양한 상황에서 물품의 적재위치 인식에 오류가 발생하게 된다. 냉동창고에서는 물품 보관을 하는 cold room의 안팎 온도차이로 인해 물품의 적재위치 오류는 물품의 변질을 가져오게 하므로 실시간 정확한 위치를 파악하는 것은 매우 중요하다. 본 논문에서는 2대의 RFID 리더기가 설치된 지게차와 천정태그를 이용하여 냉동창고 관리시스템에서 물품의 적재위치 오류를 해결하기 위한 방안을 제시한다. 지게차에 설치된 2개의 RFID 리더기는 각각 천장에 부착된 태그로부터 위치데이터와 지게차에 적재된 물품데이터를 획득한다. 2개의 리더기로부터 수집된 데이터를 분석하여 물품의 입/출고 상황정보와 물품의 이동경로정보를 실시간으로 모니터링 할 수 있다. 이를 통해 냉동창고의 물품보관에 대한 효율성을 높일 수 있게 한다.

사각 천장형 루버 디퓨저의 토출 각도에 따른 실내유동에 관한 연구 (Study on Indoor Flow According to Vane Angle of Square Ceiling Type Louver Diffuser)

  • 장헌덕;이대희;이진호
    • 대한기계학회논문집B
    • /
    • 제36권7호
    • /
    • pp.683-687
    • /
    • 2012
  • 본 연구는 CFD 해석을 이용하여 사각 천장형 루버 디퓨저의 토출각도와 토출 유량에 따른 실내 공기유동 특성에 관한 것이다. CFD 툴은 상용프로그램인 ANSYS 13.0의 CFX를 이용하였다. 연구에 사용된 디퓨저는 적은 유량에서도 충분한 도달거리를 확보할 수 있도록 모델링하였으며, 실내 크기는 $6{\times}6{\times}2.7m$로 디퓨저의 대각선 방향으로 원형 배기구를 모델링 하였다. 토출 공기의 체적유량은 5.1CMM, 7.4CMM이며, 디퓨저의 토출각도를 $30^{\circ}$에서부터 $60^{\circ}$까지 $10^{\circ}$씩 변화하여 실내의 유동특성에 대하여 고찰하였다.