Active CDS-Clamped L-Type Current-Fed Isolated DC-DC Converter

  • Nguyen, Minh-Khai;Duong, Truong-Duy;Lim, Young-Cheol;Choi, Joon-Ho
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.955-964
    • /
    • 2018
  • In this paper, an active capacitor-diode-switch (CDS) snubber is proposed for L-type current-fed isolated DC-DC converters. The proposed CDS-clamped converter has a number of advantages. It can achieve wide range zero-voltage switching (ZVS) on two switches, a continuous input current with a low ripple, a reduction of one active switch and high efficiency. The operating principles, analysis and parameter design guideline are presented. A 300 W prototype is built to test the proposed converter. Simulation and experimental results are shown at 30 V input voltage and 400 V output voltage.

Trends of Clinical Decision Support System(CDSS) (임상의사결정지원시스템(CDSS) 기술동향)

  • Lee, D.H.;Jung, H.Y.;Kim, M.H.;Lim, M.E.;Kim, D.H.;Han, Y.W.;Lee, Y.W.;Choi, J.H.;Kim, S.H.
    • Electronics and Telecommunications Trends
    • /
    • v.31 no.4
    • /
    • pp.77-85
    • /
    • 2016
  • 구글 딥마인드 알파고와 이세돌 선수와의 바둑대결 후 인공지능의 활용처로 의료분야가 거론되면서 임상의사결정지원시스템(Clinical Decision Support System: CDSS)이 최근 주목받고 있다. 기본적으로 CDSS는 환자 진료에 있어 예방, 진단, 치료, 처방 그리고 예후의 각 단계에서 임상의의 의사결정을 도와주는 시스템을 말한다. 본고에서는 CDSS의 국내외 도입 및 시장현황과 관련 기술현황을 검토하여 의료현장에서 CDSS의 활용이 활성화되기 위한 방안을 도출하고자 한다.

  • PDF

Development of Location Identification System for Moving Robot in the Sensor Space under KS Illumination Intensity Environment (국내 조명 환경에서 센서공간을 활용한 이동로봇의 위치인식시스템 개발)

  • Kang, Chul U.;Ko, Seok J.
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.9 no.2
    • /
    • pp.67-73
    • /
    • 2014
  • When a mobile robot performs in unknown environments, a location identification is an essential task. In this paper, we propose a location identification system that uses a sensor space without additional devices on the robot. Also the sensor space consists of a matrix of CDS sensor; when a robot was positioned on the CDS sensor, we can estimate the coordinate of the location by sensing a light. Based on KS illumination standard, experiments are performed in various environments. By evaluating the experimental results, we can show that the proposed system can be applicable to the location identification system of a moving robot.

Catastrophic Intramedullary Abscess Caused by a Missed Congenital Dermal Sinus

  • Dho, Yun-Sik;Kim, Seung-Ki;Wang, Kyu-Chang;Phi, Ji Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.3
    • /
    • pp.225-228
    • /
    • 2015
  • Congenital dermal sinus (CDS) is a type of occult spinal dysraphism characterized by a midline skin dimple. A 12-month-old girl presented with fever and ascending quadriparesis. She had a midline skin dimple in the upper sacral area that had been discovered in her neonatal period. Imaging studies revealed a holocord intramedullary abscess and CDS. Overlooking CDS or misdiagnosing it as benign sacrococcygeal dimple may lead to catastrophic infection and cause serious neurological deficits. Therefore, further imaging work-up or consultation with a pediatric neurosurgeon is recommended following discovery of any atypical-looking dimples in the midline.

A Study on Information Retrieval Techniques of VOCED Database (직업교육 데이터베이스 VOCED의 검색기법 연구)

  • Kim, Soon-Won
    • Journal of Information Management
    • /
    • v.27 no.1
    • /
    • pp.40-65
    • /
    • 1996
  • This study is to review information retrieval techniques of VOCED database. The VOCED database contains internationally relevant information on vocational and adult education, training and related subjects. The software used is CDS/ISIS and the records are indexed using the APSDEP Thesaurus. When searching the VOCED database, various types of search techniques can be used. Multiple word, phrase, boolean logic, term truncation, defind field, and proximity searching techniques or a mixture of all of them, make it possible to find exactly what you want in seconds.

  • PDF

Dual Sampling-Based CMOS Active Pixel Sensor with a Novel Correlated Double Sampling Circuit

  • Jo, Sung-Hyun;Bae, Myung-Han;Jung, Joon-Taek;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • In this paper, we propose a 4-transistor active pixel sensor(APS) with a novel correlated double sampling(CDS) circuit for the purpose of extending dynamic range. Dual sampling techniques can overcome low-sensitivity and temporal disparity problems at low illumination. To accomplish this, two images are obtained at the same time using different sensitivities. The novel CDS circuit proposed in this paper contains MOS switches that make it possible for the capacitance of a conventional CDS circuit to function as a charge pump, so that the proposed APS exhibits an extended dynamic range as well as reduced noise. The designed circuit was fabricated by using $0.35{\mu}m$ 2-poly 4-metal standard CMOS technology and its characteristics have been evaluated.

Toxoplasma gondii virulence prediction using hierarchical cluster analysis based on coding sequences (CDS) of sag1, gra7 and rop18

  • Subekti, Didik T;Ekawasti, Fitrine;Desem, Muhammad Ibrahim;Azmi, Zul
    • Journal of Veterinary Science
    • /
    • v.22 no.6
    • /
    • pp.88.1-88.6
    • /
    • 2021
  • Toxoplasma gondii consists of three genotypes, namely genotype I, II and III. Based on its virulence, T. gondii can be divided into virulent and avirulent strains. This study intends to evaluate an alternative method for predicting T. gondii virulence using hierarchical cluster analysis based on complete coding sequences (CDS) of sag1, gra7 and rop18 genes. Dendrogram was constructed using UPGMA with a Kimura 80 nucleotide distance measurement. The results showed that the prediction errors of T. gondii virulence using sag1, gra7 and rop18 were 7.41%, 6.89% and 9.1%, respectively. Analysis based on CDS of gra7 and rop18 was able to differentiate avirulent strains into genotypes II and III, whereas sag1 failed to differentiate.

System Effectiveness of AirDam for Natural Ventilation by U-CDS (U-CDS의 자연환기를 위한 AirDam시스템의 효과에 대한 연구)

  • Seungchul, Kim;Boohyun, Shin;Gidae, Oh
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.87-92
    • /
    • 2022
  • Recently, there has been an increasing demand for electric equipment installed on the ground to be installed in an underground space. Accordingly, U-CDS (Underground-Compact Distribution Station) installed in the underground is supplied, and to improve its weak ventilation performance, an Airdam-type structure was applied and the effect was analyzed. As a result, the temperature around the transformer was reduced by up to 9.5 degrees, and the air flow increased by up to 1.17 m/s. Airdam structure can be supplied in the form of various sculptures because it is possible to design freely while maintaining its principle.

Implementation of Knowledge Engine for SAGE-based Guideline (SAGE 기반 가이드라인 실행 지식 엔진 구현)

  • Kim, Jeong-A;Jo, In-Suk
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06a
    • /
    • pp.139-141
    • /
    • 2011
  • CDS 서비스는 검증한 임상가이드라인과 프로토콜을 임상 실무에 적용함으로써 의료의 질을 향상시키고, 비용을 절감할 수 있는 방법이다. CDS 서비스를 실무에 구현하기 위해서는 검증한 지식과 이를 실행할 수 있는 지식엔진이 필수적인 구현 컴포넌트이다. 본 논문에서는 지식의 상호운용성을 보장하는 임상가이드라인 모델링 방법으로 SAGE라는 의료지식표현 기법을 선택하고, SAGE 지식을 기존 엔진과 연계할 수 있는 방법으로 변환 방법을 제안하였다. 또한 변환을 통한 기존 지식엔진 활용의 가능성을 검증하기 위하여 변환의 정확성을 검증하였다.

Comparison of Inclusion Complex Formation Capacity of Cyclodextrins with Various Molecules and Characterization of Cyclodextrin-fatty Acid Complex (Cyclodextrin의 Inclusion Complex 형성능과 Fatty Acid와의 Complex 형성조건과 특성)

  • 이용현;정승환박동찬
    • KSBB Journal
    • /
    • v.10 no.2
    • /
    • pp.149-158
    • /
    • 1995
  • The capacity of inclusion complex formation between ${\alpha}$-, ${\beta}$-, ${\gamma}$-cyclodextrins(CDs) and various compounds, such as pH indicators, biloslalns, glycoside, amino acid, and fatty acids, was compared. Fatty acid was identified as the most suitable ligand for fractionation of CDs in terms of capacity and selectivity. The effects of complex formation conditions, such as, mixing ratio of CD and fatty acid, pH, ionic strength, and temperature, on the capacity of fatty acrid-CD complex was also investigated. The carbon number of fatty acids was identified as the most significant factor determining the capacity and selectivity of inclusion complex formation of CDs. Capric acid(C10) and palmitic acid(C16) showed high specificity for ${\alpha}$- and ${\beta}$-CDs, respectively. Under the optimal conditions, the molar ratio of complex formed was found to be 1.0:2.6 for ${\alpha}$-CD/capric acid and 1.0:1.9 for ${\beta}$-CD/palmitic acid. X-ray diffraction and infrared spectrum of the formed inclusion complex were analyzed. The changes of enthalpy($\Delta$H) of the inclusion complex formation reaction was evaluated by differential scanning calorimetry, showed that the reaction was endothermic.

  • PDF