• Title/Summary/Keyword: Cavity height

Search Result 169, Processing Time 0.023 seconds

An Experimental Study on the Estimation of Optimum Length of Soil Flow Protector with Wall Stiffness (벽체 강성에 따른 토사유입차단판의 최적 길이 산정에 관한 실험적 연구)

  • Yoo, Jae-Won;Seo, Min-Su;Son, Su-Won;Im, Jong-Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.789-799
    • /
    • 2019
  • The settlement hardly occurs in structures supported by pile foundation such as abutment, culvert but a cavity is formed in the lower part of a structure. As a result, soil discharged from the lateral ground to the cavity accelerates the settlement of the lateral ground of the structure, resulting in a larger settlement. Therefore, in order to prevent problems caused by cavity under the structure supported by pile foundation, soil Flow Protector (briefly called 'FLP'), which can be easily installed on the side of structure, was developed. In this study, an laboratory model test was carried out to prove the reduction effect of settlement and to estimate the optimal installation length of the FLP. As a result, the installation of the FLP reduced the settlement of the lateral ground and prevented the leakage of lateral ground soil into the cavity. If the stiffness of the FLP is small, the state or active earth pressure is generated in the upper part, which is not favorable for stability. But if the stiffness of the FLP is high enough, the passive earth pressure area is generated in the upper part, which will be advantageous for the stability. Also, the increased installation length of FLP is effective to reduce the settlement. And the ratio of the optimal length of the FLP to the box structure height (H = 250 mm) are flexible FLP 1.38, stiff FLP 0.73.

A Study on the Failure Cause of Large Scale Rock Slope in Limestone Quarries (석회석 광산에서 발생한 대규모 암반사면의 붕괴원인 분석에 관한 연구)

  • Lee, Sang-Eun;Kim, Hak-Sung;Jang, Yoon-Ho
    • Tunnel and Underground Space
    • /
    • v.24 no.4
    • /
    • pp.255-274
    • /
    • 2014
  • The target of this study is large scale rock slope collapsed by around 7 pm on August, 2012, which is located at ${\bigcirc}{\bigcirc}$ limestone quarries of Gangneung city, Gangwondo. The slope prior to the collapse is formed as the height of about 200 m and the average inclination of $45^{\circ}$. The estimated amount of the collapse is about $1,500,000m^3$ with respect to the slope after the collapse. Geotechnical and field investigations such as boring, geophysical prospecting, surface geological survey, geological lineaments, borehole imaging, metric 3D imaging, experimental and field test, mining work by year, and daily rainfall were performed to find the cause of rock slope failure. Various analyzes using slope mass rating, stereonet projection, limit equilibrium method, continuum and non-continuum model were conducted to check of the stability of the slope. It is expected that the cause of slope failure from the results of various analysis and survey is due to the combined factors such as topography, rainfall, rock type and quality, discontinuities, geo-structural characteristics as the limestone cavity and fault zones, but the failure of slope in case of the analysis without the limestone cavity is not occurred. Safe factor of 0.66 was obtained from continuum analysis of the slope considering the limestone cavity, so the ultimate causes of slope failure is considered to be due to the influence of limestone cavity developed along fault zone.

Study on the Characteristics of Drawbead Forces in Automotive Stamping Dies (자동차 스템핑 금형의 드로우비드력 특성에 관한 연구)

  • Moon, S.J.;Wagoner, R.H.;Keum, Y.T.
    • Transactions of Materials Processing
    • /
    • v.16 no.6
    • /
    • pp.457-462
    • /
    • 2007
  • The drawbeads, which are used for controlling the flow of the sheet into die cavity by imposing the tension and for preventing the forming defects like wrinkling, springback, etc. during the sheet forming process, affect the formability strongly because of the differences in the restraint and opening forces according to the drawbead shapes and dimensions. In this study, the experimental device enabling to measure the drawbead restraining and opening forces is manufactured and the drawing forces of circular, square, and step drawbeads are measured. The drawbead restraining and opening forces of a circular drawbead are increased as its drawbead height is increased. Similarly, those of a square drawbead are increased as its height is increased and shoulder radii decreased. The drawbead forces obtained from the experiment were compared with those calculated in the numerical simulation of stamping process of automotive fender. Good agreement was found so that the experimental measurements can be used in the simulation of auto-body stamping process.

Heat Transfer Characteristics on a Single Rotating Disk with a Shrouded Cover (슈라우드로 차폐되어진 단일회전디스크 표면의 열전달 특성)

  • Ryu, Goo-Young;Won, Chung-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1029-1037
    • /
    • 2000
  • The present study investigates the local heat/mass transfer characteristics on a rotating disk which is the top disk covered with a shroud in HDD. The naphthalene sublimation technique is employed to determine the local heat/mass transfer coefficients on the rotating disk. Flow field measurements using Laser Doppler Anemometry (LDA) and numerical calculations are performed to analyze the flow patterns induced by the disk rotation. HDD has been developed for compactness and speedy data access, thus the rotating velocity of the disk is increased and the height of a hub is decreased. The experiments are conducted for the various hub heights of 5, 10 and 15 mm, for the rotating Reynolds numbers of $5.5{\times}10^4$ to $1.1{\times}10^5$ and for the effects of the presence of a read/write head arm. The results show that the heat transfer on the rotating disk is enhanced considerably for the decrease of the hub height and for the increase of the rotating Reynolds number. The head arm inserted in the cavity decreases the heat transfer despite the enhancement of tangential RMS velocity because of the deficit of the momentum in the flow field.

Maxillary sinus augmentation using biphasic calcium phosphate: dimensional stability results after 3-6 years

  • Cha, Jae-Kook;Kim, Chingu;Pae, Hyung-Chul;Lee, Jung-Seok;Jung, Ui-Won;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.1
    • /
    • pp.47-57
    • /
    • 2019
  • Purpose: This study was designed to observe the resorption pattern of biphasic calcium phosphate (BCP) used for maxillary sinus augmentation over a 3- to 6-year healing period, and to investigate factors affecting the resorption of BCP. Methods: A total of 47 implants placed in 27 sinuses of 22 patients were investigated. All patients had residual bone height less than 5 mm at baseline. The modified Caldwell-Luc approach was used to elevate the maxillary sinus membrane, and the sinus cavity was filled with BCP (70% hydroxyapatite and 30% ${\beta}$-tricalcium phosphate). Implant placement was done simultaneously or in a staged manner. Serial radiographic analysis was performed up to 6 years postoperatively. Results: During the follow-up period, no implant loss was reported. The mean reduced height of the augmented sinus (RHO) was $0.27{\pm}1.08mm$ at 36 months, and $0.89{\pm}1.39mm$ at 72 months postoperatively. Large amounts of graft material (P=0.021) and a long healing period (P=0.035) significantly influenced the amount of RHO. In particular, there was a significant relationship between a healing period longer than 40 months and RHO. Conclusions: BCP can achieve proper dimensional stability with minimal reduction of the graft height in a 3- to 6-year healing period after maxillary sinus augmentation. The healing period and the amount of graft material influenced the resorption of BCP.

An Analysis in Optimum Coupling Method of Cylindrical Dielectric Resonator Filter Designed by Non-decaying Mode Analysis (Non-decaying 모드 해석을 이용해서 설계한 원통형 유전체 공진기 여파기의 최적 결합 방법에 대한 분석)

  • Lee, Won-Hui;Park, Chang-Won;Kim, Tai-Shin;Hur, Jung;Lee, Sang-Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.7
    • /
    • pp.14-21
    • /
    • 2001
  • In this paper, we designed and fabricated C-band bandpass filter using dielectric resonators. From waveguide cutoff frequency which applied the region between adjacent dielectric resonators, the height of cavity is determined. The cavity's diameter is determined to the twice of dielectric resonator? diameter considering the conductor loss. The resonant frequency of the DR cavity is calculated with non decaying mode analysis. Conventionally, cylindrical dielectric resonator is analysed by Cohn's model which use the decaying mode in the region between dielectric resonator wall and circular cavity wall, which is an approximated method. The external quality factor, $Q_{ex}$ has found with simulation result using Ansoft's Maxwell simulation tool. The designed filter using dielectric resonators with dielectric constant of 45 has the passband center at 5.065GHz. The bandpass filter using dielectric resonators has about 1dB insertion loss, 20MHz bandwidth and more than 30dB attenuation at $f_0+15MHz$.

  • PDF

Investigation of changes in abdominal cavity between dyspepsia patients and healthy participants when pressure pain occurs using an algometer combined with an ultrasound device: a non-randomized, controlled, pilot trial (초음파 결합형 압통계를 활용한 압통시 소화불량 환자와 건강인의 복강내 조직 변화 비교: 비무작위 대조군 예비 임상시험)

  • Jinwoong Lim;Taeseong Jeong;Hoseok Jung;Sunny Kang;Chang-Min Choi;Dong Woung Kim
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.27 no.1
    • /
    • pp.43-52
    • /
    • 2023
  • Objectives : The aim of this study was to evaluate the differences in the abdominal cavity between functional dyspepsia patients and healthy people using an algometer combined with an ultrasound device. Methods : A non-randomized, controlled, pilot trial was conducted. Thirty patients in the experimental group and fifteen participants in the control group were recruited. We collected demographical data, and measured abdominal circumference, height of the body cavity, subcutaneous fat thickness, visual analogue scale of dyspepsia symptoms in the experimental group, depth of algometer and pressure of algometer when pressure pain occurred, and the whole ultrasonic image from the beginning of pressurization to the time when pressure pain occurred. The measurements were carried out twice with the duration of 1 week. Generalized linear regression was conducted to adjust baseline characteristics. Results : A total of 45 participants (30 in experimental group, 15 in control group) were recruited and finished the trial. Females were recruited more in the experimental group than in the control group and it was statistically significant. The difference in thickness of abdominal cavity between a second before the pressure pain and at the time when pressure pain occurred was statistically significant on 1st visit, and other measurements were not statistically significant. From the results of the regression analysis, the difference between two groups was statistically significant in the differences in the thickness of stomach and up to abdominal aorta on 1st visit, and the thickness of stomach on 2nd visit, and other measurements were not statistically different. Conclusions : According to the results, there were not statistically significant differences in abdominal examination when pressure pain occurred between dyspepsia patients and healthy people. Further studies are warranted to assess the abdominal examination using devices including algometer and ultrasound devices, regarding the results of the present study.

Miniaturization Technology of the Filter for High-speed Wireless Communication Systems (초고속 무선통신 설비용 필터의 소형화에 관한 연구)

  • Hwang, Jae-Ho;Moon, Jun-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.368-371
    • /
    • 2005
  • In this paper, a small band pass filter is designed using new probe type for wireless communication system. In order to provide a band pass filter which can be reduced in dimension, can be reduced in height, and can be surface-mounted. The filter was fabricated using $TE_{01{\delta}}$ mode dielectric resonator. The input/output probes are attached to coner portion of the rectangular metal cavity. Results of the manufactured filter$(12{\times}12{\times}8mm)$ show that the center frequency is 9.953GHz, the insertion loss is -2.98 dB, the 3dB-bandwidth is 15 MHz, and the lode Q is 663.

  • PDF

The optimization of nozzle size for pulse cleaning of ceramic filter (세라믹필터 역세정을 위한 노즐 사이즈 최적화)

  • Choi, Joo-Hong;Kim, Jin-Hyoung;Chi, Hua-Chang;Yu, Lang;Sakong, Kyoung-Min;Kim, Young-Ae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.796-799
    • /
    • 2007
  • In the bench scale test unit consisting of four commercial filter elements, the traces of the transient pressure around the nozzle and overpressure in the filter cavity were measured to estimate the effect of nozzle on pulse cleaning. For the given pulse cleaning system, the convergent nozzle displayed better performance than the straight one. The optimum ratio of outlet to inside diameter of convergent nozzle was determined, which minimized the pulse gas consumption and maximized the entrainment effect. The angle and height of nozzle convergent part was also optimum operational condition, which is meaningful to the industrial applying.

  • PDF

How Can We Improve Crown-Implant Ratio in Reconstructed Mandible with Fibular Free Flap?: A New Surgical Technique Using 3D RP Model and Reconstruction Titanium Plates

  • Kim, Dong-Young;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • v.4 no.1
    • /
    • pp.13-16
    • /
    • 2017
  • Fibular free flap reconstruction is the flap of the choice in long-span mandibular bone reconstruction. The most common disadvantage of the fibular flap is short bone height to install dental implant. Double barrel fibular flap has been tried, however, bulky flap in the oral cavity hinder its use. Titanium reconstruction plate has been used simultaneously with the free fibular flap to stabilize occlusion and to fix the fibular flap. In this study, titanium reconstruction plate was fixed in the lower border of the mandible and the fibular free flap was fixed in the superior border of the titanium plate to improve implant-crown ratio. This new technique improved the longevity of the dental prosthodontics with dental implants.