• 제목/요약/키워드: Cavity flow

검색결과 902건 처리시간 0.03초

Residual stresses and viscoelastic deformation of an injection molded automotive part

  • Kim, Sung-Ho;Kim, Chae-Hwan;Oh, Hwa-Jin;Choi, Chi-Hoon;Kim, Byoung-Yoon;Youn, Jae-Ryoun
    • Korea-Australia Rheology Journal
    • /
    • 제19권4호
    • /
    • pp.183-190
    • /
    • 2007
  • Injection molding is one of the most common operations in polymer processing. Good quality products are usually obtained and major post-processing treatment is not required. However, residual stresses which exist in plastic parts affect the final shape and mechanical properties after ejection. Residual stresses are caused by polymer melt flow, pressure distribution, non-uniform temperature field, and density distribution. Residual stresses are predicted in this study by numerical methods using commercially available softwares, $Hypermesh^{TM},\;Moldflow^{TM}\;and\;ABAQUS^{TM}$. Cavity filling, packing, and cooling stages are simulated to predict residual stress field right after ejection by assuming an isotropic elastic solid. Thermo-viscoelastic stress analysis is carried out to predict deformation and residual stress distribution after annealing of the part. Residual stresses are measured by the hole drilling method because the automotive part selected in this study has a complex shape. Residual stress distribution predicted by the thermal stress analysis is compared with the measurement results obtained by the hole drilling method. The molded specimen has residual stress distribution in tension, compression, and tension from the surface to the center of the part. Viscoelastic deformation of the part is predicted during annealing and the deformed geometry is compared with that measured by a three dimensional scanner. The viscoelastic stress analysis with a thermal cycle will enable us to predict long term behavior of the injection molded polymeric parts.

T cell phenotype and intracellular $IFN-{\gamma}$ production in peritoneal exudate cells and gut intraepithelial lymphocytes during acute Toxoplasma gondii infection in mice

  • Lee, Young-Ha;Shin, Dae-Whan
    • Parasites, Hosts and Diseases
    • /
    • 제40권3호
    • /
    • pp.119-129
    • /
    • 2002
  • Although there are many reports on the splenic (systemic) T cell response after Toxoptasma gondii infection, little information is available regarding the local T cell responses of peritoneal exudate cells (PEC) and gut intraepithelial Iymphocytes (IEL) following peroral infection with bradyzoites. Mice were infected with 40 cysts of the 76K strain of T. gondii, and then sacrificed at days 0, 1, 4, 7 and 10 postinfection (PI). The cellular composition and T cell responses of PEC and IEL were analyzed. The total number of PEC and IEL per mouse increased after infection, but the ratio of increase was higher in IEL. Lymphocytes were the major component of both PEC and IEL. The relative percentages of PEC macrophages and neutrophils/eosinophils increased signiflcantly at day 1 and 4 PI, whereas those of IEL did not change significantly. The percentage of PEC NK1.1 and ${\gamma\delta}T$ cells peaked at day 4 PI (p < 0.0001), and CD4 and $CD8{\alpha}T$ cells increased continuously after infection. The percentages of IEL $CD8{\alpha}$ and ${\gamma\delta}T$ cells decreased slightly at first, and then increased. CD4 and NK1.1 T cells of IEL did not change significantly after infection. $IFN-{\gamma}-producing$ PEC NK1.1 T cells increased significantly from day 1 PI, but the other T cell subsets produced $IFN-{\gamma}$ abundantly thereafter. The proportion of IEL $IFN-{\gamma}-producing$ $CD8{\alpha}$ and ${\gamma\delta}T$ cells increased significantly after infection, while IEL NK1.1 T cells had similar $IFN-{\gamma}$ production patterns. Taken together, CD4 T cells were the major phenotype and the important $IFN-{\gamma}$ producing T cell subsets in PEC after oral infection with T. gondii whereas $CD8{\alpha}T$ cells had these roles in IEL. These results suggest that PEC and IEL comprise different cell differentials and T cell responses, and according to infection route these factors may contribute to the different cellular immune responses.

코콜이 환자의 sleep splint 착용 전후의 음향학적 및 공기역학적 연구 (An Aerodynamic study used aerophone II for snoring patients)

  • 정세진;김현기;신효근
    • 대한치과의사협회지
    • /
    • 제49권4호
    • /
    • pp.219-226
    • /
    • 2011
  • Snoring and obstructive sleep apnea (OSA) are common sleep disordered breathing conditions. Habitual snoring is caused by a vibration of soft tissue of upper airway while breath in sleeping, and obstructive sleep apnea is caused by the repeated obstructions of airflow for a sleeping, specially airflow of pharynx. Researchers have shown that snoring is the most important symptom connected with the obstructive sleep apnea syndrome The treatment is directed toward improving the air flow by various surgical and nonsurgical methods. The current surgical procedures used are uvulopalatopharyngoplasty(UPPP), orthognathic surgery, nasal cavity surgery. Among the nonsurgical methods there are nasal continuous positive air pressure(CPAP), pharmacologic therapy. weight loss in obese patient, oral appliance(sleep splint). Sleep splint brings the mandible forward in order to increase upper airway volume and prevents total upper airway collapse during sleep. However, the precise mechanism of action is not yet completely understood, especially aerodynamic factor. The aim of this study evaluated the effect of conservative treatment of snoring and OSAS by sleep splint through measured aerodynamic change by an aerophone II. We measured a airflow, sound pressure level, duration, mean power from overall airflow by aerophone II mask. The results indicated that on a positive correlation between a decrease in maximum airflow rate and a decrease in maximum sound pressure level, on a negative correlation between a decrease in maximum airflow rate and a increase in duration.

A CONTROLLED CYCLIC LOADING ON THE SURFACE TREATED AND BONDED CERAMIC: STAIRCASE METHOD

  • Yi, Yang-Jin
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.298-306
    • /
    • 2008
  • STATEMENT OF PROBLEM: Effect of surface treatment of ceramic under loading does not appear to have been investigated. PURPOSE: The aim of this study was to investigate the effect of surface treatment of esthetic ceramic, which is performed to increase the bonding strength, on the fracture stress under controlled cyclic loading condition. MATERIAL AND METHODS: Sixty 1.0 mm-thick specimens were made from Mark II Vitablocs (Vita Zahnfabrik, Germany) and divided into 3 groups: polished (control), sandblasted, and etched. Specimens of each group were bonded to a dentin analog material base including micro-channels to facilitate the flow of water to the bonding interface. Bonded ceramics were cyclically loaded with a flat-end piston in the water (500,000 cycles, 15Hz). Following completion of cyclic loading, specimens were examined for subsurface crack formation and subsequent stress was determined and loaded to next specimen by the staircase method according to the crack existence. RESULTS: There were significant differences of mean fatigue limit in the sandblasted (222.86 ${\pm}$ 23.42 N) and etched group (222.86 ${\pm}$ 14.16 N) when compared to polished group (251.43 ${\pm}$ 10.6 N) (P<.05; Wald-type pair-wise comparison and post hoc Bonferroni test). Of cracked specimens, surface treated group showed longer crack propagation after 24 hours. All failures originated from the radial cracking without cone crack. Fracture resistance of this study was very low and comparable to failure load in the oral cavity. CONCLUSION: Well controlled cyclic loading could induce clinically relevant cracks and fracture resistance of Mark II ceramic was relatively low applicable only to anterior restorations. Surface treatment of inner surface of feldspathic porcelain in the matsicatory area could influence lifetime of restorations.

심강내관상동맥(Intracavitary Coronary Artery)질환에 대한 관상동맥우회술 -수술치험 1예- (Coronary Artery Bypass Graft (CABG) for Intracavitary Coronary Artery Disease - A case report-)

  • 김수완;성기익;박표원;전태국;박계현;이영탁
    • Journal of Chest Surgery
    • /
    • 제38권7호
    • /
    • pp.504-506
    • /
    • 2005
  • 심강내관상동맥은 전체 관상동맥우회술 환자 중 약 $0.2\~0.3\%$에서 발견되며, 국내에서는 아직 보고된 바 없는 극히 드문 관상동맥기형의 일종이다. 수술 전 관상동맥조영술을 통하여 진단하기 어렵고, 관상동맥우회술 후에 우심실로부터의 출혈이 발생할 수 있으므로 우심실절개 부위의 견고한 봉합이 필요하다. 기존의 증례 보고에 따르면 외과용거즈(pledget)를 이용한 수평매트리스봉합(horizontal mattress suture)이 추천되기는 하나 주위의 심근을 압박하여 관상동맥가지 및 관통동맥의 협착을 유발할 수 있어, 단순단속봉합(simple interrupted suture)을 이용하고도 수술 후 별다른 합병증 얼이 호전된 예를 경험하였기에 보고하는 바이다.

머시영역의 비등방성을 고려한 2성분혼합물의 응고과정 (Solidification Process of a Binary Mixture with Anisotropy of the Mushy Region)

  • 유호선
    • 대한기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.162-171
    • /
    • 1993
  • 본 연구에서는 2성분혼합물의 응고과정해석에 머시영역의 비등방성을 포함시 킬수 있는 모델을 정립하고 실제계산을 수행하여 비등방성이 천이현상 및 조대편석(m- acrosegregation)에 미치는 영향을 보이고자 한다. 이 과정에서 기본 방정식의 변형 을 통한 수치해석의 효율화에 관해서도 취급할 것이다. 해석대상은 비등방성의 효과 가 잘 나타날 수 있으면서 해석은 용이한 2차원 정사각형용기로 선택하였다. 대상혼 합물은 실용적으로 관심있는 금속 합금과 결정구조가 유사하며 물성치가 비교적 잘 확 립된 염화암모늄수용액(NH$_{4}$C1-H$_{2}$O)이다. 특히 아공정염화암모늄수용액은 부력비(buoyancy factor)가 -1.4정도로서 온도와 농도구배에 의한 부력이 크기는 비슷 하지만 작용방향이 반대이기 때문에 이중확산대류의 전형적인 형태를 고찰하기에 편리 한 물질이다.

항복응력과 미끄럼현상을 고려한 분말사출성형 충전공정의 유한요소해석 (Finite Element Analysis of Powder Injection Molding Filling Process Including Yield Stress and Slip Phenomena)

  • 박주배;권태헌
    • 대한기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.1465-1477
    • /
    • 1993
  • 본 연구에서는 분말혼합체의 특성인 항복응력을 포함한 Generalized Newtonian Fluid의 구성 방정식을 도입하고 미끄럼현상을 고려한 신소재의 사출성형 충전과정 해석용 CAE(computer aided engineering)시스템을 개발하였다. 수치모사를 위한 수치해석방법으로는, 유한요소법(finite element method)과 유한차분법(finite difference method)을 함께 사용하였다. 유한요소법과 검사체적법(control volume technique) 을 병용하여 유동의 진행을 수치모사 하였으며, 유한차분법을 사용하여 온도분포를 계산하였다.

비침습식 미세전류자극이 실험적으로 유발된 흰쥐의 골관절염 회복에 미치는 영향 (The Effect of Microcurrent Electrical Stimulation on the Articular Cartilage Recovery in Osteoarthritis)

  • 방현수;강종호;천송희;김민희;박수진;김진상;박래준
    • 대한물리의학회지
    • /
    • 제2권2호
    • /
    • pp.151-159
    • /
    • 2007
  • Purpose : The purpose of the study was to investigate the effect of cold application on knee joint in rats induced by osteoarthritis. Methods : Osteoarthritis was induced in female Sprague-Dowley rats by injecting into articular cavity of knee joint with 4% Kaolin, 2% carrageenan. Rats were divided randomly into the control and MES applicated group. The Experimental group was applicated MES in rat knee joint for 30 minutes. Results : Recovery of articular cartilage surface and thickness of articular cartilage increased after MES application. And chondrocytes were distributed widely throughout the cartilage matrix. The physical effects of Microcurrent Electrical Stimulation. Decrease in blood flow. Delay of neurotransmitter velocity Decrease in metabolism activity and inhibit the progress of the infection. Decrease in pain and muscle rigidity, inhibition of circulation Conclusion : This study shows that MES application affects articular cartilage recovery in osteoarthritis.

  • PDF

박리성 대동맥류(DeBakey Type III)의 외과적 치험 -2예보고- (dissecting aortic aneurysm (DeBakey Type III) -Report of two cases-)

  • 문경훈
    • Journal of Chest Surgery
    • /
    • 제19권3호
    • /
    • pp.443-448
    • /
    • 1986
  • Aortic dissection is a serious disease that mortality does not approach to zero despite of medical and surgical improvement. Recently two cases of aortic dissection were treated with good results by the two other methods. Case 1 [57-Y-0-Male]; Chief complaint was chest pain radiating to the back. Preoperatively he was controlled by Minipress, dichlotride, & sodium nitroprusside. Aortography showed DeBakey Type III aortic dissection extending from just below the Lt. subclavian artery to the proximal portion of the origin of the renal artery. Through the midline long incision Flow reversal & Thrombo-exclusion method was used, and bypass course was proximal anastomosis at the ascending aorta - through the Rt. thoracic cavity - midportion of the diaphragm - posterior to the liver, stomach, & pancreas - distal anastomosis at the abdominal aorta proximal to its bifurcation. Bypass graft was preclotted 20 mm Dacron Woven Graft, and the aortic arch between the Lt. subclavian artery & Lt. common carotid artery was divided and meticulously sutured. Control aortogram which was done at 4th postoperative month revealed obstruction of the false lumen by thrombosis, and complications were not noticed. Case 2 [53-Y-0-Male]; Chief complaint was chest pain radiating to the abdomen. DeBakey Type III aortic dissection which was similar to the case 1 was detected by the aortography, and involvement of the Lt. subclavian & common carotid arteries was suspicious. Through the Lt. posterolateral thoracotomy the Ringed Intraluminal Sutureless Graft, No. 22 mm, was inserted from just below the Lt. common carotid artery to the midportion of the descending thoracic aorta under total circulation arrest using a F-F bypass, and the Lt. subclavian artery was ligated. Postoperatively hospital course was uneventful with antihypertensive drugs, and any specific complications were not noticed.

  • PDF

분말사출성형 시 분말 혼합체의 유동성 시뮬레이션을 통한 투광성 알루미나 소결체의 특성 연구 (A study on the Powder Injection Molding of Translucent Alumina via Flowability Simulation of Powder/Binder Mixture)

  • 김형수;변종민;김세훈;김영도
    • 한국분말재료학회지
    • /
    • 제21권3호
    • /
    • pp.215-221
    • /
    • 2014
  • Translucent alumina is a potential candidate for high temperature application as a replacement of the glass or polymer. Recently, due to the increasing demand of high power light emitting diode (LED), there is a growing interest in the translucent alumina. Since the translucent property is very sensitive to the internal defect, such as voids inside or abnormal grain growth of sintered alumina, it is important to fabricate the defect-free product through the fabrication process. Powder injection molding (PIM) has been commonly applied for the fabrication of complex shaped products. Among the many parameters of PIM, the flowability of powder/binder mixture becomes more significant especially for the shape of the cavity with thin thickness. Two different positions of the gate were applied during PIM using the disc type of die. The binder was removed by solvent extraction method and the brown compact was sintered at $1750^{\circ}C$ for 3 hours in a vacuum. The flowability was also simulated using moldflow (MPI 6.0) with two different types of gate. The effect of the flowability of powder/binder mixture on the microstructure of the sintered specimen was studied with the analysis of the simulation result.