• Title/Summary/Keyword: Cavity Wall

Search Result 547, Processing Time 0.031 seconds

Numerical Investigation on Heat Transfer Characteristics for Natural Convection Flows in a Doubly-Inclined Cubical-Cavity (이중으로 경사진 3차원 캐비티내 자연대류 열전달 특성에 관한 수치해석적 연구)

  • Myong, Hyon-Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.435-442
    • /
    • 2009
  • Three-dimensional heat transfer characteristics for natural convection flows are numerically investigated in the doubly-inclined cubical-cavity according to the variation of a newly defined orientation angle �� of the hot wall surface from horizontal plane at moderate Rayleigh numbers. Numerical simulations of laminar flows are conducted in the range of Rayleigh numbers($10^4{\leq}Ra{\leq}10^5$) and $0^{\circ}{\leq}{\alpha}90^{circ}$ with a solution code(PowerCFD) employing unstructured cell-centered method. Comparisons of the average Nusselt number at the cold face are made with benchmark solutions and experimental results found in the literature. It is found that the average Nusselt number at the cold wall has a maximum value around the specified orientation ${\alpha}$ at each Rayleigh number. Special attention is also paid to three-dimensional thermal characteristics in natural convection according to new orientation angles at Ra��= $1{\times}10^5$, in order to investigate a new additional heat transfer characteristic found in the range of above Ra = $6{\times}10^4$.

Vacuum Die Casting Mold Design of Fuel Cell Bipolar Plate using Die Filling Simulation and Experimental Verification (금형 충전 해석을 이용한 연료전지 분리판 진공 다이캐스팅 금형 설계 방안 및 실험 검증)

  • Jin, Chul-Kyu;Jang, Chang-Hyun;Kang, Chung-Gil
    • Journal of Korea Foundry Society
    • /
    • v.32 no.2
    • /
    • pp.65-74
    • /
    • 2012
  • In this paper, we present the results of our studies on optimal die design towards development of a vacuum die casting process to fabricate fuel cell bipolar plate with micro-channel array. Cavity and overflow shape is designed by computational filling analysis of MAGMA soft. Optimal die design consists of seven overflows at the end of cavity and three overflows at each side wall of cavity. The molten metal that passed the gate and reached the side wall flowed into the side overflow, no turbulent flow occurred, and the filling behavior and velocity distribution were uniform. In addition, partially solidified molten metal passing through the channel was perfectly eliminated by overflow without back-flow. When vacuum pressure, injection speed of low and high region was 300 mbar, 0.3 m/s and 2.5 m/s respectively with Silafont 36 die casting alloy, sound sample without casting defects was obtained. The experimental results are nearly consistent with simulation results.

A Case of Infected Huge Lymphangioma in Pelvic Cavity (골반강에 발생한 감염된 거대 림프관종 1예)

  • Choi, Woo-Seok;Lee, Seong-Ho;Chung, Seok-Young;Song, Phil-Hyun;Baek, Un-Gi;Cho, Chul-Kyu;Park, Tong-Choon;Choi, Joon-Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • v.19 no.1
    • /
    • pp.63-67
    • /
    • 2002
  • Lymphangioma is a benign tumor resulted from abnormal communication between large dermal lymphatic channels and central lymphatic system. The tumor is encountered more often in the neck and axilla and less often in mediastinum, omentum, retroperitoneum, and scrotum. It rarely developes at urogenital system, and there has been no previous description of lymphangioma involving the bladder wall in Korea. We report a case of 35-year-old female with infected huge lymphagioma ansing from pelvic cavity and involving bladder wall.

  • PDF

Collection characteristics of wet-type cyclone with wall cavity for air pollutants removal of marine diesel engines (선박 대기오염 저감을 위한 벽면 캐비티 적용 습식 사이클론의 집진특성)

  • Yoa, Seok-Jun;Kwon, Jun-Hyeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.2
    • /
    • pp.185-192
    • /
    • 2014
  • The main object of this study was to investigate the collection characteristics of wet-type cyclone with wall cavity. The experiment was executed to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as water spray, water spray type, inlet velocity etc. In results, for the present system of wet-type, the pressure drop represented 35 mm $H_2O$, while in dry-type 33 mm $H_2O$ showing lower 6% at $v_{in}=21m/s$. In case of $v_{in}=21m/s$ and water spray 200 mL/min, the collection efficiency of the present system became significantly higher as 96.8% comparing to that of the conventional wet-type scrubber. Additionally, for 200 mL/min, $SO_2$ removal efficiencies decreased with the increment of inlet velocity representing 75.0, 62.5, 50.0%, at $v_{in}=6,9,12m/s$, respectively.

Numerical Study on the Mixing Enhancement of Parallel Supersonic-subsonic Wakes Using Wall Cavities (공동을 이용한 초음속-아음속 평행류에서의 혼합증대에 관한 수치적 연구)

  • Moon, Seong-Mok;Chang, Se-Myong;Kim, Chong-Am;Lee, Kyoung-Hoon;Kim, In-Soo;Ahn, Su-Hong;Woo, Kwan-Je
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.353-356
    • /
    • 2010
  • A computational study on the enhancement of parallel supersonic-subsonic mixing wakes is conducted and compared with available experimental data. The first aim of the present work is to show a direct comparison between numerical predictions and equivalent experimental data for the baseline case. The Pitot pressure distribution data are in good agreement between computation and experiment, and the results show that Menter's SST model with the compressibility correction gives the best performance. Further we investigate the effects of primary parameters such as the position of the cavity, and the arrangement of the cavity at the given flow condition.

  • PDF

DIFFERENCE IN BOND STRENGTH ACCORDING TO FILLING TECHNIQUES AND CAVITY WALLS IN BOX-TYPE OCCLUSAL COMPOSITE RESIN RESTORATION (박스 형태의 복합레진 수복시 충전법 및 와동벽에 따른 결합력 차이에 관한 연구)

  • Ko, Eun-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.350-355
    • /
    • 2009
  • Bond strength depends on characteristics of bonding surface and restorative technique. The majority of studies dealing with dentin bond strength were carried out on flat bonding surface, therefore, difference of bond strength between axial wall and pulpal wall is not clear yet. This study evaluated bonding difference between cavity walls in class I composite resin restoration with different filling techniques. Twenty extracted caries-free human third molars were used. Cavities were prepared in 6 ${\times}$4 ${\times}$3 mm box-type and divided into four groups according to filling technique and bonding surface: Group I; bulk filling - pulpal wall, Group II; bulk filling - axial wall, Group III; incremental filling - pulpal wall, Group IV; incremental filling - axial wall. Cavities were filled with Filtek $Z250^{(R)}$(3M/ESPE., USA) and Clearfill SE $bond^{(R)}$(Kuraray, Japan). After 24 hour-storage in $37^{\circ}C$water, the resin bonded teeth were sectioned bucco-lingualy at the center of cavity. Specimens were vertically sectioned into 1.0 ${\times}$1.0 mm thick serial sticks perpendicular to the bond surface using a low-speed diamond saw (Accutom 50, Struers, Copenhagen, Denmark) under water cooling. The trimmed specimens were then attached to the testing device and in turn, was placed in a universal testing machine (EZ test, Shimadzu Co., Kyoto, Japan) for micro-tensile testing at a cross-head speed of 1 mm/min. The results obtained were statistically analyzed using 2-way ANOVA and t-test at a significance level of 95%. The results were as follows: 1. There was no significant difference between bulk filling and incremental filling. 2. There was no significant difference between pulpal wall and axial wall, either. Within the limit of this study, it was concluded that microtensile bond strength was not affected by the filling technique and the site of cavity walls.

A Study of Particle Diffusion from a Cavity in Flow Tube (유동관에 형성된 Cavity로부터의 입자확산현상 연구)

  • Lee, J.W.;Goo, J.H.;Kim, H.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.29-38
    • /
    • 1994
  • Particle contamination into and out of a cavity-cylindrical cavities with aspect ratios(width/depth) less than, equal to 1 and langer than 1, and also three dianensional T's attached to a cylindrical flow tube was studied numerically, using a finite difference method. In the process of unsteady particle diffusion, the particles contained in a concentration boundary layer near the tube wall plays an important role in the initial stage, after which a quasi-steady concentration profile is developed inside the cavity, resulting in an exponential change of concentration with time. Average concentration and its rate of change are observed to be closely correlated by a power law function in terms of Reynolds number and the logarithm of Schmidt number. Effects of the three parameters-Re, Sc, and aspect ratio-are analysed and well explained.

  • PDF

Damping Layout Optimization to Reduce Structure-borne Noises in a Two-Dimensional Cavity (이차원 공동의 구조기인소음 저감을 위한 제진재의 최적배치)

  • Lee Doo-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.805-812
    • /
    • 2006
  • An optimization formulation is proposed to minimize sound pressures in a two-dimensional cavity by controlling the attachment area of unconstrained damping materials. For the analysis of structural-acoustic systems, a hybrid approach that uses finite elements for structures and boundary elements for cavity is adopted. Four-parameter fractional derivative model is used to accurately represent dynamic characteristics oJ the viscoelastic materials with frequency and temperature. Optimal layouts of the unconstrained damping layer on structural wall of cavity are identified according to temperatures and the amount of damping material by using a numerical search algorithm.

  • PDF

A Experimental Study on Chracteristics of a Mixed Convection Heat Transfer in a Cavity with upper Channel (상부채널을 갖는 캐비티의 혼합대류 열전달에 관한 실험적연구)

  • Bae, Suk-Tae
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.115-121
    • /
    • 1998
  • In this study a channel cavity flow was performed. The channel has small size in the upper cavity region. At the gap is supplied by driven flow for Reynolds number. The experimental study was carried out in a channel cavity with square heat surface by visualization equipment with Mach-Zehnder interferometer and laser apparatus. Heat source was uniform heat flux($0.4W/cm^2,\;0.8W/cm^2,\;1.2W/cm^2$). When the bottom wall is heated, the tendency of natural convection flows are vigorous increasing heat flux.

  • PDF

THE ADAPTIBILITY OF LIGHT-CURED GLASS-IONOMER CEMENTS TO CAVITY WALLS. (와동벽에 대한 광중합형 글래스아이오노머 시멘트의 적합도)

  • Kang, Mi-Sun;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.173-182
    • /
    • 1995
  • The purpose of this study was to evaluate the adaptability of light-cured glass ionomer cement to cavity walls. Class V cavities were prepared on the labial surfaces of extracted bovine incisor teeth. The cavities were restored with Fuji II as self-cured glass ionomer cement and Fuji II LC, Vitremer as light-cured glass ionomer cement. Fluorescent markers (fluoreceine and rhodamin B) were incorperated into liquid and primer for a better image of microscopic observation. Restored teeth were sectioned by longitudinal and labiolingual direction. The adaptability at the tooth-restoration interface was assessed incisally, axially and cervically by confocal scanning laser microscope. Following results were obtained : 1. Chemical-cured glass iomomer cement restoration showed close adaptation on the all of the cavity walls, but, cracks formed within the cement. 2. Light-cured glass ionomer cement restoration was well adapted to the cavity walls, but showed crack in the cement adjacent to axial dentinal wall. 3. There' was no significant difference in adaptability between two light-cured glass ionomer cement restorations.

  • PDF