• 제목/요약/키워드: Cavity Wall

검색결과 547건 처리시간 0.03초

유한요소법을 이용한 수종 2급 아말감 와동의 비교연구 (A STUDY ON COMPARISON OF VARIOUS KINDS OF CLASSII AMALGAM CAVITIES USING FINITE ELEMENT METHOD)

  • 석창인;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.432-461
    • /
    • 1995
  • The basic principles in the design of Class II amalgam cavity preparations have been modified but not changed in essence over the last 90 years. The early essential principle was "extension for prevention". Most of the modifications have served to reduce the extent of preparation and, thus, increase the conservation of sound tooth structure. A more recent concept relating to conservative Class II cavity preparations involves elimination of occlusal preparation if no carious lesion exists in this area. To evaluate the ideal ClassII cavity preparation design, if carious lesion exists only in the interproximal area, three cavity design conditions were studied: Rodda's conventional cavity, simple proximal box cavity and proximal box cavity with retention grooves. In this study, MO amalgam cavity was prepared on maxillary first premolar. Three dimensional finite element models were made by serial photographic method. Linear, eight and six-nodal, isoparametric brick elements were used for the three dimensional finite element model. The periodontal ligament and alveolar bone surrounding the tooth were excluded in these models. Three types model(B option, Gap option and R option model) were developed. B option model was assumed perfect bonding between the restoration and cavty wall. Gap option model(Gap distance: $2{\mu}m$) was assumed the possibility of play at the interface simulated the lack of real bonding between the amalgam and cavity wall (enamel and dentin). R option model was assumed non-connection between the restoration and cavty wall. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed the displacement, 1 and 2 direction normal stress and strain with FEM software ABAQUS Version 5.2 and hardware IRIS 4D/310 VGX Work-station. The results were as followed. 1. Rodda's cavity form model showed greater amount of displacement with other two models. 2. The stress and strain were increased on the distal marginal ridge and buccopulpal line angle in Rodda's cavity form model. 3. The stress and strain were increased on the central groove and a part of distal marginal ridge in simple proximal box model and proximal box model with retention grooves. 4. With Gap option, Rodda's cavity form model showed the greatest amount of the stress on distal marginal ridge followed by proximal box model with retention grooves and simple proximal box model in descending order. 5. With Gap option, simple proximal box model showed greater amount of stress on the central groove with proximal box model with retention grooves. 6. Retention grooves in the proximal box played the role of supporting the restorations opposing to loads.

  • PDF

TLC 를 이용한 사각공동내의 열전도 영역에 기포의 형성으로 인한 열전달 현상 구명 (A Study of Heat Transfer Phenomena due to a Formed Gas Bubble under Heat-Conduction Domain in A Closed Square Cavity)

  • 엄용균;유재봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.85-89
    • /
    • 2003
  • In a closed square cavity filled with a liquid, a cooled the upper horizontal wall and a heated the lower horizontal wall, the flow isn't generated under the ground-based condition when Rayleigh number is lower than 1700. In such case the flow phenomena near an air bubble under a cooled horizontal wall were investigated. The temperature and the flow fields were studied by using the Thermo-sensitive Liquid-Crystal and the image processing. The qualitative analysis for the temperature and the flow fields were carried out by applying the image processing technique to the original data. Injecting bubble at the center point of upper cooled wall, the symmetry shape of two vortexes near an air bubble was observed. The bubble size increased, the size of velocity and the magnitude of velocity increased. In spite of elapsed time, a pair of two vortexes was the unique and steady-state flow in a square cavity and wasn't induce to the other flow in the surround region.

  • PDF

Experimental and numerical analysis of RC structure with two leaf cavity wall subjected to shake table

  • Onat, Onur;Lourenco, Paulo B.;Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • 제55권5호
    • /
    • pp.1037-1053
    • /
    • 2015
  • This paper presents finite element (FE) based pushover analysis of a reinforced concrete structure with a two-leaf cavity wall (TLCW) to estimate the performance level of this structure. In addition to this, an unreinforced masonry (URM) model was selected for comparison. Simulations and analyses of these structures were performed using the DIANA FE program. The mentioned structures were selected as two storeys and two bays. The dimensions of the structures were scaled 1:1.5 according to the Cauchy Froude similitude law. A shake table experiment was implemented on the reinforced concrete structure with the two-leaf cavity wall (TLCW) at the National Civil Engineering Laboratory (LNEC) in Lisbon, Portugal. The model that simulates URM was not experimentally studied. This structure was modelled in the same manner as the TLCW. The purpose of this virtual model is to compare the respective performances. Two nonlinear analyses were performed and compared with the experimental test results. These analyses were carried out in two phases. The research addresses first the analysis of a structure with only reinforced concrete elements, and secondly the analysis of the same structure with reinforced concrete elements and infill walls. Both researches consider static loading and pushover analysis. The experimental pushover curve was plotted by the envelope of the experimental curve obtained on the basis of the shake table records. Crack patterns, failure modes and performance curves were plotted for both models. Finally, results were evaluated on the basis of the current regulation ASCE/SEI 41-06.

벽면 캐비티 각에 따른 GDI 분무의 벽 충돌 과정에 대한 수치적 연구 (Numerical Study on Wall Impingement Process of GDI Spray According to Wall Cavity Angle)

  • 심영삼;김덕줄;최경민
    • 대한기계학회논문집B
    • /
    • 제31권12호
    • /
    • pp.971-978
    • /
    • 2007
  • A spray-wall impingement process of a hollow-cone fuel spray from the high-pressure swirl injector in the Gasoline Direct Injection (GDI) engine were experimented and calculated at various wall geometries. The Linearized Instability Sheet Atomization (LISA) & the Aerodynamically Progressed Taylor Analogy Breakup (APTAB) model and the Gosman model were applied to model the breakup and the wall impingement process of the hollow-cone fuel spray. The numerical modelings were implemented in the modified KIVA code. The calculation results of spray characteristics, such as a spray development process and a radial distance after wall impingement, compared with the experimental results by the Laser Induced Exciplex Fluorescence (LIEF) technique. The droplet size distribution and the ambient gas velocity field, which are generally difficult to obtain by the experimental methods, were also calculated and discussed. It was found that the radial distance after wall impingement and Sauter Mean Diameter (SMD) decreased with increasing a cavity angle.

직육면체 공동 내부의 소음 저감을 위한 능동 구조-음향 연성제어

  • 이상원;황철호;이장무
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.218-223
    • /
    • 1997
  • The technique used is the active structural acoutrol (ASAC)approach which involves controlling the acoustic response of a panel-cavity covpled system by applying oscillating force inputs in the form of prezoelectric actuators directly to the flexible panel. The linear quadratic Gaussian control scheme is used for attenuating nosie inside the rectangular enclosure causing by flexible wall vibration. Results indicated the application of control inputs to the radiating wall resukted in considerable noise reductions inside the cavity. Auso,the possibility of application to the more complicated fluid-structure coupled system is verified.

양벽온이 다른 장방형용기 내에서 얼음의 융해과정에 관한 실험적 연구 (An Experimental Study on Melting Process of Ice in a Rectangular Cavity with Different Wall Temperature)

  • 임우택;김병철
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.547-555
    • /
    • 1995
  • Melting process of ice in a rectangular cavity with different temperature walls has been studied experimentally. Front shape of ice and melting rate were affected by initial temperature of ice and variation of temperature distribution and density gradient. When the hot wall temperature was below $8^{\circ}C$, the melting rates were higher at the bottom than those of at the top due to the density inversion, but with increasing the hot wall temperature the melting rates at the top were affected by hot wall and were higher than those of at the bottom. When the initial temperature of ice was low, melting rates were low, but with increasing the time melting rates were almost the same with those of each initial temperature of ice.

  • PDF

선택적 투과성면을 가진 직사각형 밀폐공간에서의 표면복사 및 자연대류해석 (Analysis of the Combined Surface Radiation-Natural Convection in a Rectagular Enclosure with a Selectively Transparent Wall)

  • 박대성;이택식;이준식
    • 대한설비공학회지:설비저널
    • /
    • 제16권2호
    • /
    • pp.194-203
    • /
    • 1987
  • A numerical study has been conducted on the combined radiation-natural convection heat transfer characteristics in a square cavity with a selectively transparent wall. The fluid in the cavity is assumed to be transparent to the thermal radiation. The effect of the wall emissivity is mainly considered in view of the temperature and flow fields. The comparison of the radiative heat flux and conductive heat flux variations along the isothermal wall is presented as well. The results show that the Nusselt number distribution is fairly uniform due to the com-pensative interaction of the radiation and convection heat transfer.

  • PDF

고온에서 벽면 형상에 따른 GDI 분무의 충돌 과정 및 연료 액막 형성에 대한 수치적 연구 (Numerical Study on Impingement Process and Fuel Film Formation of GDI Spray according to Wall Geometry under High Ambient Temperature)

  • 심영삼;최경민;김덕줄
    • 한국자동차공학회논문집
    • /
    • 제16권2호
    • /
    • pp.166-174
    • /
    • 2008
  • Numerical study on the impingement process and the fuel film formation of the hollow-cone fuel spray was conducted under vaporization condition, and the effect of the wall cavity angle on spray-wall impingement structure was investigated. A detailed understanding of this phenomena will help in designing injection systems and controlling the strategies to improve engine performance and exhaust emissions of the Gasoline Direct Injection (GDI) engine. The improved Abramzon model was used to model the spray vaporization process and the Gosman model was adopted for modeling of spray-wall impingement process. The calculated results of the spray-wall impingement process were compared with experimental results. The velocity field of the ambient gas, the Sauter Mean Diameter (SMD) and the generated fuel film on the wall, which are difficult to obtain by the experimental method, were also calculated and discussed. It was found that the radial distance after the wall impingement and the SMD decreased with increasing the cavity angle and the temperature.

광배근피판을 이용한 외상성 흉벽 결손의 재건 1례 (Chest Wall Reconstruction Using Latissimus Dorsi Myocutaneous Flap)

  • 이호철;류한영
    • Journal of Chest Surgery
    • /
    • 제29권2호
    • /
    • pp.239-243
    • /
    • 1996
  • 역행성 호흡 운동을 방지 하고 종격동내의 구조물을 보호하는 흥곽의 기능을 고려해야 하기 때문에 흉벽 재건은 임상적으로 간단하지가 않다. 영남대 학교병원 흉부외과에서는 교통사고로 좌측 전흉부의 전층에 걸친 흉벽 결손을 가진 37세 남자 환자에게 흉벽 재건술을 시행하였다. 외상직후 변연 절제와 지혈을 위해 1차 응급 수술이 시행되었고, 수술후25일째 흉벽 재건을 위한 2차수술을 시행하였다. 흉벽재건에는 흉배동맥을 피판경으로한 광배근피판과 좌측 대퇴부로부터 피부이식이 이용되었다. 흉벽 재건 수술후 인공호흡기 보조없이 자가 호흡이 가능하였으며, 수술후 3개월에 시행한 폐기능 검사(FVC, FEV1.0)는 예측치의 80%로 나타났다. 광배근피판을 이용한 흉벽 재건의 수술후 경과는 생리학적, 해부학적 그리고 미학적으로도 만족할만 하였다.

  • PDF