• 제목/요약/키워드: Cavitation test

검색결과 267건 처리시간 0.029초

아지무스 추진기 캐비테이션 시험 장치 개발 및 캐비테이션 성능 연구 (Azimuth Thruster Cavitation Test Apparatus Development and Cavitation Performance Study)

  • 안종우;설한신;정홍석;박영하;김상환;한정일
    • 대한조선학회논문집
    • /
    • 제61권3호
    • /
    • pp.161-169
    • /
    • 2024
  • In order to investigate cavitation performance for the azimuth thruster in Large Cavitation Tunnel (LCT), the cavitation test apparatus was designed and manufactured. Generally the model scale is determined by the pod dynamometer with about 70mm diameter. Recently as ships with azimuth thruster have become bigger, the problem of the model ship installation was occurred. The model ship with pod dynamometer couldn't be installed in the LCT test section. The cavitation test apparatus and technique which can conduct the cavitation test without pod dynamometer were developed. The cavitation tests were conducted in torque identity method instead of thrust identity method. The target ship with azimuth thruster is 18K LNG bunkering vessel. As the full-scale ship test was conducted, the model cavitation tests were conducted at the same operating conditions. The fluctuating pressure levels of the full-scale ship were compared to those of the model tests. Another model cavitation test was conducted in the foreign institute and the cavitation observation results were compared to those of LCT. Through the comparison with the existing results, it is thought that the cavitation test for the azimuth thruster can be conducted in torque identity method.

터보펌프 Cavitation 성능시험기 개발 및 성능시험에 관한 연구 (Development of Turbopump Cavitation Performance Test Facility and the Test of Inducer Performance)

  • 손동기;김춘택;윤민수;차봉준;김진한;양수석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.619-624
    • /
    • 2001
  • A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar; rotational speed 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification.

  • PDF

디젤기관 실린더라이너의 진동캐비테이션 손상 억제에 관한 연구 (A Study on the Damage Suppression of Diesel Engine Cylinder Liners under Vibratory Cavitation)

  • 정기철;황재호;임우조
    • 수산해양교육연구
    • /
    • 제10권2호
    • /
    • pp.226-238
    • /
    • 1998
  • With the advent of high speed and high output diesel engines, cavitation erosion-corrosion of wet cylinder liners is one of the most prevalent types of failure. The cavitation erosion-corrosion at cylinder liners in water cooled diesel engines is considered to be to the collapse of cavitation bubbles attributed to the cylinder liner vibration. To suppress cavitation damage in cylinder liner, the addition of an inhibitor would be more general method and innovations such as the improvement in the geometric design of the equipment or the selection of suitably resistant construction materials are necessary. In this study, photomicrographs from vibratory facility cavitation specimens and from an eroded liner of a field diesel engine are compared. The behavior of cavitation bubbles grown in fluid is observed under vibration conditions by taking direct photographs with high speed camera. In order to determine the contributions of pure cavitation erosion and of pure corrosion to the total cavitation damage are be studied by following an experimental programme which includes three types of test: (1)pure cavitation erosion test, (2)pure corrosion test, and (1)cavitation erosion-corrosion test. Also cavitation damage under vibratory cavitation is reduced by using flow in tap water.

  • PDF

경사축 추진기 모형시험에서 추진기 소음과 캐비테이션 침식 상관관계 연구 (Correlation study between propeller noise and cavitation erosion with inclined propeller model test)

  • 설한신;백부근
    • 한국음향학회지
    • /
    • 제38권3호
    • /
    • pp.328-333
    • /
    • 2019
  • 본 논문은 선박 추진기의 캐비테이션 침식현상을 연구하기 위하여 추진기에서 발생하는 소음과 캐비테이션 격렬도의 연관성에 대하여 분석하였다. 캐비테이션 침식은 캐비테이션 붕괴의 빈도와 강도로 정의 할 수 있는 '캐비테이션 격렬도'와 밀접히 연관되어 있다. 캐비테이션 붕괴에 의해서 발생하는 압력파는 다양한 진폭과 지속시간의 연속적인 펄스의 형태로 나타나며 이를 캐비테이션 거동과 동조 분석하여 캐비테이션 붕괴에 따른 추진기 소음 연관성을 파악하였다. 이 기법을 경사축 추진기시험을 활용하여 추진기침식시험에 대한 정량적 평가방안을 제시하였다.

터보펌프 인듀서의 흡입성능에 대한 직경과 회전속도의 영향 (The Effect of the Diameter and Rotational Velocity on the Cavitation Performance of a Turbopump Inducer)

  • 손동기;구현철;차봉준;양수석;이대성
    • 한국유체기계학회 논문집
    • /
    • 제5권1호
    • /
    • pp.27-32
    • /
    • 2002
  • The turbopump inducer cavitation is very important for the success of a liquid rocket engine. In this study, the performance test and cavitation performance test were carried out at various rotational speeds with two inducers of different diameter. The rotational speed was varied by 4000, 6000, and 8000 rpm, and the size effect was tested for the normal inducer and twice-enlarged one. The hydraulic performance results showed that the similarity was satisfied over the entire test range of the present study. The blade thickness effect was examined and showed that the increased blade thickness resulted in decreased efficiency and worse cavitation performance for the large tip clearance. The cavitation performance test results showed that the breakdown NPSH increased as the flow coefficient, and was not affected by the rotational speed.

터보펌프 인듀서의 흡입성능에 대한 직경과 회전속도의 영향 (The Effect of the Diameter and Rotational Velocity on the Cavitation Performance of a Turbopump Inducer)

  • 손동기;구현철;차봉준;양수석;이대성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.229-234
    • /
    • 2001
  • The turbopump inducer cavitation is very important for the success of a Liquid rocket engine. In this study the performance test and cavitation performance test were carried out at various rotational speed with two different diameter inducers. The rotational speed were varied 4000, 6000, 8000 rpm and the variation to the diameter of an inducer were taken as design size and 2 times enlarged size. The major results of the present study were as follows. 1. The hydraulic performance results showed that the similarity was met over the entire test range of the present study. 2. The blade thickness effect was examined and showed that the increased blade thickness resulted in decreased efficiency and worse cavitation performance for large tip clearance. 3. The cavitation performance test results showed that the breakdown NPSH increases as the flow coefficient and does not affected by the rotational speed.

  • PDF

Effects of Ultrasonic Amplitude on Electrochemical Properties During Cavitation of Carbon Steel in 3.5% NaCl Solution

  • Jang, I.J.;Kim, K.T.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제19권4호
    • /
    • pp.163-173
    • /
    • 2020
  • Cavitation corrosion in many industrial plants has recently become a serious issue. Cavitation corrosion has generally been investigated using a vibratory method based on ASTM G32 standard, and the test can be divided into direct cavitation and indirect cavitation. Cavitation corrosion test uses the vibration frequency of the horn of 20 kHz with constant peak-to-peak displacement amplitude. In this work, the peak-to-peak amplitude was controlled from 15 ㎛ to 85 ㎛, and electrochemical measurements were obtained during indirect cavitation. The relationship between cavitation corrosion rate and electrochemical properties was discussed. Corrosion steps of carbon steel at the initial stage under cavitation condition in 3.5 % NaCl can be proposed. When the cavitation strength is relatively low, corrosion of the steel is more affected by the electrochemical process than by the mechanical process; but when the cavitation strength is relatively high, corrosion of the steel is affected more by the mechanical process than by the electrochemical process. This work confirmed that the critical ultrasonic amplitude of 0.42 %C carbon steel is 53.8 ㎛, and when the amplitude is less than 53.8 ㎛, the corrosion effect during the cavitation corrosion process is higher than the mechanical effect.

한국형 발사체용 터보펌프 조립체 시험에서의 캐비테이션 불안정성 (Cavitation Instability of Turbopump Assembly Test for KSLV-II)

  • 김대진;최창호;김진선
    • 항공우주시스템공학회지
    • /
    • 제14권5호
    • /
    • pp.100-106
    • /
    • 2020
  • 액체로켓엔진용 터보펌프는 작동 조건에서 캐비테이션 불안정성에 노출되며, 이는 터보펌프의 안정성에 영향을 미친다. 이를 확인하기 위해 터보펌프 조립체 시험 중 나타난 캐비테이션 불안정성의 특징을 살펴보았다. 시험 중 산화제펌프는 대표적인 캐비테이션 불안정성인 초조화 선회 캐비테이션과 부착 비대칭 캐비테이션에 노출되었다. 캐비테이션 불안정성이 발생되지 않는 조건에서 작동했던 연료펌프에서도 산화제펌프의 초조화 선회 캐비테이션에 의한 진동이 확인되었다.

Incipient Cavitation in a Bulb Turbine: Model Test and CFD Calculation

  • Necker, Jorg;Aschenbrenner, Thomas
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.140-149
    • /
    • 2011
  • For a certain operating point of a horizontal shaft bulb turbine (i.e. volume flow, net head, blade angle, guide vane angle) the efficiency for different pressure levels (i.e. different Thoma-coefficient ${\sigma}$) is calculated using a commercial Computational Fluid Dynamics (CFD-)-code including two-phase flow and a cavitation model. The results are compared with experimental results achieved at a closed loop test rig for model turbines. The comparison of the experimentally and numerically obtained efficiency and the visual impression of the cavitation show a good agreement. Especially the drop in efficiency is calculated with satisfying accuracy. This drop in efficiency in combination with the visual impression is of high practical importance since it contributes to determine the admissible cavitation in a bulb-turbine. It is seen that the incipient cavitation in Kaplan type turbines has no major importance in determing this admissible amount of cavitation.

Effects of Rare Earth Metal Addition on the Cavitation Erosion-Corrosion Resistance of Super Duplex Stainless Steels

  • 심성익;박용수;김순태;송치복
    • 소성∙가공
    • /
    • 제8권3호
    • /
    • pp.301-301
    • /
    • 1999
  • Austenitic stainless steels such as AISI 316L have been used in equipment in which fluid flows at high speeds which can induce cavitation erosion on metallic surfaces due to the collapse of cavities, where the collapse is caused by the sudden change of local pressure within the liquid. Usually AISI 316L is susceptible to cavitation erosion. This research focuses on developing a better material to replace the AISI 316L used in equipment with high speed fluid flow, such as impellers. The effects of Rare Earth Metal (REM) additions on the cavitation erosion-corrosion resistance of duplex stainless steels were studied using metallographic examination, the potentiodynamic anodic polarization test, the tensile test, the X-ray diffraction test and the ultrasonic cavitation erosion test. The experimental alloys were found to have superior mechanical properties due to interstitial solid solution strengthening, by adding high nitrogen (0,4%), as well as by the refinement of phases and grains induced by fine REM oxides and oxy-sulfides. Corrosion resistance decreases in a gentle gradient as the REM content increases. However, REM containing alloys show superior corrosion resistance compared with that of other commercial alloys (SAF 2507, AISI 316L). Owing to their excellent mechanical properties and corrosion resistance, the alloys containing REM have high cavitation erosion-corrosion resistance.