• Title/Summary/Keyword: Cavitation Index

Search Result 13, Processing Time 0.03 seconds

Cavitation Visualization Test for Shape Optimization of Bottom Plug in Reversing Valve (공동현상 가시화 실험을 통한 절환밸브 바텀플러그 형상 최적화)

  • Kim, Tae An;Lee, Myeong Gon;Han, Seung Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.11
    • /
    • pp.913-918
    • /
    • 2016
  • A three-way reversing valve, which provides rapid and accurate changes in the water flow direction without requiring any precise control device, is used in automotive washing machines to remove oil and dirt that remain on the machined engine and transmission blocks. Because of the complicated shape of the bottom-plug, however, cavitation occurs in the plug. In this study, the cavitation index and POC (percent of cavitation) were used to quantitatively evaluate the cavitation effect occurring in the bottom-plug on the downstream side. An optimal shape design was conducted via parametric study with a simple CAE model to avoid time-consuming CFD analysis and hard-to-achieve convergence. To verify the results of the numerical analysis, a flow visualization test was conducted using a specimen prepared according to ISA-RP75.23. In this test, the flow characteristics, such as cavitation occurring on the downstream side, were investigated using flow test equipment that included a valve, pump, flow control system, and high-speed camera.

Study on the Reduction Method of Occurred Cavitation in a System (시스템내 발생하는 캐비테이션 저감방법에 관한 연구)

  • Park, Sang-Eun;Roh, Hyung-Woon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.1 s.22
    • /
    • pp.45-50
    • /
    • 2004
  • Two phenomena often encountered in liquid flow, which were completely absent in gas or vapor flow, were cavitation and flashing. These phenomena were of significant interest in any comprehensive discussion of control valves or contracted devices since their occurrence would affect the device sizing procedures, might introduce noise and vibration, and also may limit the life expectancy of device components and the immediate downstream piping. Thus, this study aimed to find the reduction method of occurred cavitation in system by the computer simulation. A derivative six model with different dimensions of cavity were adopted. From the results, it was found that the length of the cavity was mote important factor to reduce the pressure drop over the control valves or contracted devices than the depth of the cavity. And the pressures along the centerline of the contracted devices were dropped two times in the case of haying the large length (Lc=1.5D) of cavity.

Electrochemical and Cavitation-Erosion Characteristics of Duplex Stainless Steels in Seawater Environment (해수 환경에서 듀플렉스 스테인리스강의 전기화학적 거동 및 캐비테이션 특성)

  • Heo, Ho-Seong;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.466-474
    • /
    • 2021
  • A wet type scrubber for merchant vessel uses super austenitic stainless steels with pitting resistance equivalent number (PREN) of 40 or higher for operation in a harsh corrosive environment. However, it is expensive due to a high nickel content. Thus, electrochemical behavior and cavitation erosion characteristics of UNS S32750 as an alternative material were investigated. Microstructure analysis revealed fractions of ferritic and austenitic phases of 48% and 52%, respectively, confirming the existence of ferritic matrix and austenitic island. Potentiodynamic polarization test revealed damage at the interface of the two phases because of galvanic corrosion due to different chemical compositions of ferritic and austenitic phases. After a cavitation test, a compressive residual stress was formed on the material surface due to impact pressure of cavity. Surface hardness was improved by water cavitation peening effect. Hardness value was the highest at 30 ㎛ amplitude. Scanning electron microscopy revealed wave patterns due to plastic deformation caused by impact pressure of the cavity. The depth of surface damage increased with amplitude. Cavitation test revealed larger damage caused by erosion in the ferritic phase due to brittle fracture derived from different strain rate sensitivity index of FCC and BCC structures.

Shape Optimization of Three-Way Reversing Valve for Cavitation Reduction (3 방향 절환밸브의 공동현상 저감을 위한 형상최적화)

  • Lee, Myeong Gon;Lim, Cha Suk;Han, Seung Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.11
    • /
    • pp.1123-1129
    • /
    • 2015
  • A pair of two-way valves typically is used in automotive washing machines, where the water flow direction is frequently reversed and highly pressurized clean water is sprayed to remove the oil and dirt remaining on machined engine and transmission blocks. Although this valve system has been widely used because of its competitive price, its application is sometimes restricted by surging effects, such as pressure ripples occurring in rapid changes in water flow caused by inaccurate valve control. As an alternative, one three-way reversing valve can replace the valve system because it provides rapid and accurate changes to the water flow direction without any precise control device. However, a cavitation effect occurs because of the complicated bottom plug shape of the valve. In this study, the cavitation index and percent of cavitation (POC) were introduced to numerically evaluate fluid flows via computational fluid dynamics (CFD) analysis. To reduce the cavitation effect generated by the bottom plug, the optimal shape design was carried out through a parametric study, in which a simple computer-aided engineering (CAE) model was applied to avoid time-consuming CFD analysis and difficulties in achieving convergence. The optimal shape design process using full factorial design of experiments (DOEs) and an artificial neural network meta-model yielded the optimal waist and tail length of the bottom plug with a POC value of less than 30%, which meets the requirement of no cavitation occurrence. The optimal waist length, tail length and POC value were found to 6.42 mm, 6.96 mm and 27%, respectively.

Evaluation of Passive Joint Laxity of the Coxofemoral Joints from Distraction Radiography in the Korean Jindo (신연촬영법에 의한 진돗개 고관절 이완성의 방사선학적 평가)

  • Kim Sangki
    • Journal of Veterinary Clinics
    • /
    • v.21 no.4
    • /
    • pp.369-373
    • /
    • 2004
  • The pelvic distraction-stress radiographs of 50 clinically normal Korean Jindo which confirmed to have non-dysplastic hip joints on the ventrodorsal extension view, were investigated to evaluate the passive coxofemoral joint laxity as quantified by the distraction index. The synovial fluid cavitation of the unilateral coxofemoral joint was detected in 8 dogs, and distraction index was not measured in theses cavitated joints. The distraction index measured minimally 0.20, and maximally 0.74. The medial distraction index for the dog examined was 0.42, and 75th percentile distraction index was below 0.50.

Numerical Examinations of Damage Process on the Chuteway Slabs of Spillway under Various Flow Conditions (여수로 방류에 따른 여수로 바닥슬래브의 손상 발생원인 수치모의 검토)

  • Yoo, Hyung Ju;Shin, Dong-Hoon;Kim, Dong Hyun;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.4
    • /
    • pp.47-60
    • /
    • 2021
  • Recently, as the occurrence frequency of sudden floods due to climate variability increased, the damage of aging chuteway slabs of spillway are on the rise. Accordingly, a wide array of field survey, hydraulic experiment and numerical simulation have been conducted to find the cause of damage on chuteway slabs. However, these studies generally reviewed the flow characteristics and distribution of pressure on chuteway slabs. Therefore the derivation of damage on chuteway slabs was relatively insufficient in the literature. In this study, the cavitation erosion and hydraulic jacking were assumed to be the causes of damage on chuteway slabs, and the phenomena were reproduced using 3D numerical models, FLOW-3D and COMSOL Multiphysics. In addition, the cavitation index was calculated and the von Mises stress by uplift pressure distribution was compared with tensile and bending strength of concrete to evaluate the possibility of cavitation erosion and hydraulic jacking. As a result of numerical simulation on cavitation erosion and hydraulic jacking under various flow conditions with complete opening gate, the cavitation index in the downstream of spillway was less than 0.3, and the von Mises stress on concrete was 4.6 to 5.0 MPa. When von Mises stress was compared with tensile and bending strength of concrete, the fatigue failure caused by continuous pressure fluctuation occurred on chuteway slabs. Therefore, the cavitation erosion and hydraulic jacking caused by high speed flow were one of the main causes of damage to the chuteway slabs in spillway. However, this study has limitations in that the various shape conditions of damage(cavity and crack) and flow conditions were not considered and Fluid-Structure Interaction (FSI) was not simulated. If these limitations are supplemented and reviewed, it is expected to derive more efficient utilization of the maintenance plan on spillway in the future.

Damages of Chuteway Slabs of Spillway by Water Release (수문방류에 따른 여수로 바닥슬래브의 손상 발생)

  • Shin, Dong-Hoon;Jung, Woo-Sung;Yoo, Hyung Ju;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.64-64
    • /
    • 2021
  • 댐의 중요 구성요소 중 하나인 여수로 구조물은 관행적으로 단위길이당 100m3/s 정도의 유량이 흐를 수 있도록 설계를 하고, 이를 초과할 때는 여수로 구조물에 피해가 가지 않도록 공기혼입 장치를 설치하거나 콘크리트의 설계강도를 증가시키는 대책을 사용하는 것이 일반적이다(댐설계 기준·해설, 2011) 그러나 건설된 지 오래된 댐의 경우 여수로 콘크리트 구조물의 설계강도가 낮고(최저 16.7MPa) 수문방류 횟수가 많아 최근에 건설된 댐 여수로 보다 상대적으로 많은 손상이 발생되어 있어 잦은 보수보강이 요구되고, 점차 유지관리 비용이 증대되고 있어 노후된 여수로 구조물일수록 기능을 유지하면서도 유지관리 비용을 절감할 수 있는 방안의 수립이 요구되고 있다. 이에 본 연구에서는 𐩒𐩒𐩒댐 여수로를 대상으로 2020년 홍수기 전·후의 여수로 바닥슬래브의 손상상태를 3D드론 매핑, 육안조사 및 내구성 조사결과 등을 이용한 정밀분석을 통해 수문방류시 여수로 바닥슬래브에 가장 큰 손상을 일으키는 손상메커니즘으로 유수에 의한 부상(uplift)에 의한 파손 메커니즘(Flow-driven uplift failure mechanism)을 제시하였으며, 여수로 바닥슬래브의 가장 일반적 손상원인으로 간주되고 있는 공동현상(cavitation)이 공동지수(cavitation index)가 0.3이상인 경우에도 발생할 수 있음을 확인하였다. 이와 같은 관찰 및 분석결과는 보다 많은 사례를 통하여 보완될 경우 향후 여수로 구조물의 설계 뿐만 아니라 보수보강 방법이나 유지관리, 더나아가서는 종합적 댐시설물 자산관리 계획을 수립하는데 매우 유용한 자산이 될 수 있다.

  • PDF

Factors Associated with Persistent Sputum Positivity at the End of the Second Month of Tuberculosis Treatment in Lithuania

  • Diktanas, Saulius;Vasiliauskiene, Edita;Polubenko, Katazyna;Danila, Edvardas;Celedinaite, Indre;Boreikaite, Evelina;Misiunas, Kipras
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.3
    • /
    • pp.233-240
    • /
    • 2018
  • Background: Non-conversion of sputum smear and culture prolongs the infectivity of the patient and has been associated with unfavorable outcomes. We aimed to evaluate factors associated with persistent sputum positivity at the end of two months of treatment of new case pulmonary tuberculosis (TB). Methods: Data of 87 human immunodeficiency virus-negative patients with culture-positive drug-susceptible pulmonary TB admitted to local university hospital between September 2015 and September 2016 were reviewed. Factors associated with sputum smear and/or culture positivity at the end of the second month of treatment were analyzed. Results: Twenty-two patients (25.3%) remained smear and/or culture-positive. Male sex, lower body mass index (BMI), unemployment, alcohol abuse, higher number of lobes involved and cavities on chest X-rays, shorter time to detection (TTD) on liquid cultures, higher respiratory sample smear grading and colony count in solid cultures, higher C-reactive protein, erythrocyte sedimentation rate, leukocytosis, thrombocytosis, and anemia were all significantly associated with persistent sputum positivity. However, in the logistic regression analysis only male sex, lower BMI, alcohol abuse, higher radiological involvement, cavitation, higher smear grading, higher colony count in solid cultures and shorter TTD were determined as independent factors associated with persistent sputum positivity at the end of 2 months of treatment. Conclusion: In conclusion, higher sputum smear and culture grading at diagnosis, shorter TTD, higher number of lobes involved, cavitation, male sex, alcohol abuse, and lower BMI were independently associated with persistent sputum positivity. These factors should be sought when distinguishing which patients will remain infectious longer and possibly have worse outcomes.

Examinations of Damage Mechanism on the Chuteway Slabs of Spillway under Various Flow Conditions (여수로 방류에 따른 여수로 바닥 슬래브의 손상 메커니즘 검토)

  • Yoo, Hyung Ju;Shin, Dong-Hoon;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.251-251
    • /
    • 2021
  • 최근 기후변화로 인한 집중호우의 영향으로 홍수 시 댐으로의 유입량이 설계 당시보다 증가하여 댐의 안전성 확보가 필요하다(감사원, 2003). 이에 건설교통부(2003)는 기후변화와 댐 노후화에 대비하여 치수능력증대사업을 추진하여 댐의 홍수배제능력을 확보하였고, 환경부(2020)에서는 40년 이상 경과된 댐을 대상으로 스마트 안전관리체계 구축을 통한 선제적 보수보강, 성능개선 및 자산관리로 댐의 장수명화를 목적으로 댐의 국가안전대진단을 추진하고 있다. 이에 본 연구에서는 댐 시설(여수로)의 노후도 평가 시 활용 될 수 있는 여수로 표면손상 원인규명에 대하여 3차원 수치모형(FLOW-3D 및 COMSOL Multiphysics)을 통해 검토하고자 한다. 연구대상 댐은 𐩒𐩒댐으로 지형 및 여수로를 구축하였으며, 계획방류량(200년 빈도) 및 최대방류량(PMF) 조건에서 모의를 수행하였다. 수치모의 계산의 정확도 검토를 위하여 Baffle의 설치를 통하여 시간에 따른 유량의 변화를 설계 값과 비교하였고 오차가 1.0% 이내를 만족하는 것을 확인하였다. 여수로 표면손상의 다양한 원인 중 기존연구(USBR, 2019)를 통하여 공동침식(Cavitation Erosion) 및 수력잭킹(Hydraulic Jacking)에 초점을 두었으며 방류조건 별 공동지수(Cavitation Index)산정을 통하여 공동침식 위험 구간을 확인하였다. 이음부의 균열 및 공동으로 인한 표층부 콘크리트의 탈락현상을 가속화시키는 수력잭킹 검토를 위하여 국부모형을 구축하였고 음압력(Negative Pressure), 정체압력(Stagnation Pressure), 양압력(Uplift Pressure)의 분포를 확인하였다. 최종적으로 COMSOL Multiphysics를 통하여 압력분포에 따른 구조해석을 수행하여 폰 미세스(Von Mises) 등가응력 및 변위를 검토하여 콘크리트의 탈락가능성을 확인하였다. 본 연구는 여수로 공동부 및 균열부에서의 손상메커니즘을 확인할 수 있는 기초적인 연구이지만 향후에는 다양한 지형조건 및 흐름조건에서의 압력분포 분석 및 유체-구조물 상호작용(Fluid-Structure Interaction, FSI)모의를 수행한다면 구조물 노후도 및 잔존수명 평가에 필요한 손상한계함수 도출이 가능할 것으로 기대된다.

  • PDF

A Study on the Chamical and Physical Characteristics of Ultrasonic-Energy-Added Diesel Fuel (초음파 에너지 부가 지젤연료의 화학적, 물리적 특성에 관한 연구)

  • 최두석;윤면근;류정인
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.147-155
    • /
    • 1996
  • This study investigated the characteristics of ultrasonic-energy-added diesel fuel. We compared the characteristics used H-NMR spectrum, FT-IR spectrum, viscosity and surface tension between conventional diesel fuel and ultrasonic-energy-added diesel fuel. The result are obtained as follow : We knew that ultrasonic energy result to reduce BI and weaken viscosity and surface tension. Also, the ultrasonic energy caused to reduce aromatics Ha and increase Alkanes Hγ. The effect of ultrasonic-energy-added dieselfuel was principally caused by change of chemical structures and a physical characteristics.

  • PDF