The Proposal of Debrisflow Investigation (토석류 재해 조사법의 제안)

  • Choi, Hui-Rim;Chang, Bhum-Soo;Lee, Wang-Gon;Park, Sang-Duk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1100-1106
    • /
    • 2009
  • A debris flow is known as that flood and landslide of water cause much physical human damages worldwide to complex natural disaster that happen combining and happy event is happening mainly in urgent mountains area in domestic. Because happen about debris flow that happen from each place every year and is drift, mechanism of accumulation definitely make clear and great many damage is not running out. Must grasp actual conditions of priority debris flow to need debris flow prevention countermeasure and lay countermeasure to take away damage by debris flow. Because collecting actual conditions of debris flow that happen by objective investigation methods and accuracy, proposed about investigation calamity investigation method so that can calculate debris flow damage and prepare in subsequentness damage.

  • PDF

A Study on the Thermal Analysis for Electrical Wire in Overload and Short of Low Voltage Wiring (저압 배선선로의 과부하 및 단락사고 발생시 전선의 열해석에 관한 연구)

  • 이상호;오홍석
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.56-60
    • /
    • 2002
  • Recently, with the growth of software for electro-thermal analysis, it has been studied the precise analysis and investigation of cause for the electrical fire using computer simulation on the basis of theory for electro-thermal analysis. But it is very lacking for the precise analysis and investigation of cause for the electrical fire. In this paper, we have simulated the thermal analysis for electrical wire according to the value of current in a overload and a short with the electrical wire of the L's company product(600 V VVF) using the electro-thermal finite element method(Flux2D).

The Cause of Fire from Incomplete Electric Contact and Identifying It (불완전 접촉에 의한 발화원인 및 식별방법에 관한 연구)

  • Choi, S.B.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.9-22
    • /
    • 2008
  • We identified objectively the ignition spot of real fire scene and electrical machinery and appliances in sections which were acted for fire cause. By pointing out the actual condition of dealing electronic devices and researching the way of solution, I will presents the fundamental materials which will help to prevent recurrence.

  • PDF

A Study on the Causes and the Analysis of Electrical Fires - focused on Heat Analysis for Electrical Wires- (전기화재의 발생원인 및 분석에 관한 연구 - 전선의 열해석을 통하여 -)

    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.72-76
    • /
    • 2002
  • Nowaday, with the growth of software for electro-thermal analysis, it has been studied the precise analysis and investigation of cause for the electrical fire using computer simulation on the basis of theory for electro-thermal analysis. But it is very lacking for the precise analysis and investigation of cause for the electrical fire. In this paper, we have simulated the thermal analysis for electrical wire according to the value of current and deteriorating time in a overload and a short with the electrical wire of the L's company product(600 V VVF : Three core) using the elec-tro-thermal finite element method(Flux2D).

CURRENT STATUS AND IMPORTANT ISSUES ON SEISMIC HAZARD EVALUATION METHODOLOGY IN JAPAN

  • Ebisawa, Katsumi
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1223-1234
    • /
    • 2009
  • The outlines of seismic PSA implementation standards and seismic hazard evaluation procedure were shown. An overview of the cause investigation of seismic motion amplification on the Niigata-ken Chuetsu-oki (NCO) earthquake was also shown. Then, the contents for improving the seismic hazard evaluation methodology based on the lessons learned from the NCO earthquake were described. (1) It is very important to recognize the effectiveness of a fault model on the detail seismic hazard evaluation for the near seismic source through the cause investigation of the NCO earthquake. (2) In order to perform and proceed with a seismic hazard evaluation, the Japan Nuclear Energy Safety Organization has proposed the framework of the open deliberation rule regarding the treatment of uncertainty which was made so as to be able to utilize a logic tree. (3) The b-value evaluation on the "Stress concentrating zone," which is a high seismic activity around the NCO hypocenter area, should be modified based on the Gutenberg-Richter equation.

The Study on the Accidents analysis and preventive measures from a excavator (굴삭기로 인한 재해분석 및 예방대책에 관한 연구)

  • Lee, Yong-Soo;Gang, Yong-Tak;Kim, Jin-Su;Kim, Chang-Eun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.283-297
    • /
    • 2010
  • This study carried out the investigation about the actual conditions of the management, disaster analysis and safety awareness on excavator in one of construction equipment and tried to make it's preventive measures. To achieve this, first of all, the accident of the internal Construction Industry process Investigation and Analysis, and then analyze an cause of accident based on it. Next, For the conditions of safety management conduct a survey to Investigation and Analysis and Propose preventive measures. The results of this study can be summarized as follows. 1st, Status of safety awareness and management of construction equipment tend to seek quickly and easily for the interests of sight. 2nd, Half the precincts of the equipment is causing major disaster. 3rd, The risk of excavator operation's indicators and drivers is so much potential. 4th, The preventive measures are needed for strengthening safety education, professional legal education, changes in safety awareness, the development of prevention system.

  • PDF

A Field State Investigation on Standalone PV streetlight for Development of Real-time Analysis Technology (독립형 태양광 가로등의 실시간 분석기술 개발을 위한 실태조사)

  • Kim, Doo Hyun;Kim, Sung Chul;Hwang, Dong Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.5
    • /
    • pp.10-14
    • /
    • 2013
  • This paper is aimed to investigate the actual conditions of standalone PV(Photovoltaics) streetlight in public place and analyze cause of failure and derive the method of decrease for standalone PV streetlight. The cost of installing standalone PV streetlight in a public for the safety and convenience of life is expensive(300 million won per unit). Management of standalone PV streetlight is important because it is operating system itself, after installation, but concern degree of management is very low and development of technology has not been done. Accordingly, standalone PV streetlight in public place is not operate in night, this phenomenon is lasted for several days to months. Therefore this study, for standalone PV streetlight constantly to keep the normal operation, investigation conducted to check status of standalone PV streetlight(50 units), the voltage of the main parts and analyze the cause of the failure. In addition, the improvement of standalone PV streetlight is suggested by using FTA(fault tree analysis).

Cause Investigation and Verification of Fire Accidents for Road and Street Lighting (가로등 화재사고의 원인규명과 검증)

  • Shong, Kil-Mok;Han, Woon-Ki;Kim, Jong-Min;Kim, Young-Seok;Kim, Myoung-Soo;Kim, Hyeok-Soo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • This paper carried out a variety of analysis for a finding out the causes of fire on the street lamp. The glass bulb of 250W metal-halide(MH) lamps attached with the impurities rose the temperature by at $410.4^{\circ}$ in normal condition. Therefore, a lamp apparatus is needed the improvement for ventilation and the protection against dust. The heat of MH lamps is diffused through out the luminous tube, a glass bulb, and apparatus by degrees. The accident cause of the lamp is presumed that the accumulated heat by deposits of the inner part. It will be recommended the improvement of the structure that aren't the external impurity and accumulated heat in the MH lamps set.

  • PDF

Analysis of an Arson fire of Motor Vehicle (자동차 방화사례의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.112-119
    • /
    • 2011
  • In this study, a fire cause of setting fire to one's own car to collect the insurance is analyzed. Through a close examination of causes of this car fire, it is suggested to improve current practices and institutions: (1) A collection system of fallen vehicle parts or fire debris in the fire site should be established; (2) A system of providing fire site information in detail should be established when a police station requests National Institute of Scientific Investigation (NISI) to examine causes of vehicle fires; (3) When a burned car is suspected of arson, a fire station and a police station should maintain a mutual cooperation system; (4) Procedures of examining the causes of vehicle arson in National Institute of Scientific Investigation (NISI) should be improved; and (5) Recognition of the examination of fire causes and correlation with analysis equipment should be changed.

The Study on the Accidents analysis and preventive measures from a excavator (굴삭기로 인한 재해분석 및 예방대책에 관한 연구)

  • Lee, Yong-Soo;Gang, Yong-Tak;Kim, Jin-Su;Kim, Chang-Eun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.3
    • /
    • pp.81-91
    • /
    • 2010
  • This study carried out the investigation about the actual conditions of the management, disaster analysis and safety awareness on excavator in one of construction equipment and tried to make it's preventive measures. To achieve this, first of all, the accident of the internal Construction Industry process Investigation and Analysis, and then analyze an cause of accident based on it. Next, For the conditions of safety management conduct a survey to Investigation and Analysis and Propose preventive measures. The results of this study can be summarized as follows. 1st, Status of safety awareness and management of construction equipment tend to seek quickly and easily for the interests of sight. 2nd, Half the precincts of the equipment is causing major disaster. 3rd, The risk of excavator operation's indicators and drivers is so much potential. 4th, The preventive measures are needed for strengthening safety education, professional legal education, changes in safety awareness, the development of prevention system.