• 제목/요약/키워드: Cathodic current

검색결과 302건 처리시간 0.022초

Polypyrrole Doped with Sulfonate Derivatives of Metalloporphyrin: Use in Cathodic Reduction of Oxygen in Acidic and Basic Solutions

  • 송위환;백운기
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권2호
    • /
    • pp.183-188
    • /
    • 1998
  • Incorporation of metalloporphyrins into polypyrrole (PPy) film was achieved either by electropolymerization of pyrrole in the presence of metal-tetra(sulfonatophenyl)porphyrin anion (MTSPP, M=Co, Fe) or by metalizing hydrogenated tetra(4-sulfonatophenyl)porphyrin anion (H2TSPP) doped into PPy through ion-exchange. Electrochemical reduction of oxygen on the PPy doped with metallo porphyrin (PPy-MTSPP) was studied in acidic and basic solutions. Oxygen reduction on PPy-MTSPP electrodes appeared to proceed through a 4-electron pathway as well as a 2-electron path. In acidic solutions, the overpotential for O2 reduction on PPy-CoTSPP electrode was smaller than that on gold by about 0.2 V. In basic solutions the overpotential of the PPy-CoTSPP electrode in the activation range was close to those of Au and Pt. The limiting current was close to that of Au. However, polypyrrole doped with cobalt-tetra(sulfonatophenyl)porphyrin anion (PPy-CoTSPP) or with iron-tetra(sulfonatophenyl)porphyrin anion (PPy-FeTSPP) was found to have limited potential windows at high temperatures (above 50 ℃), and hence the electrode could not be held at the oxygen reduction potentials in basic solutions (pH 13) without degradation of the polymer.

Pulsed Amperometric Detection of Metal Ions Complexing with EDTA in a Flow Injection System

  • 이준우;여인형;편종홍
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권3호
    • /
    • pp.316-318
    • /
    • 1997
  • A general and universal detection method, which can be used in high performance liquid chromatography (HPLC) and flow injection analysis (FIA) system for the determination of any metal ions complexing with ethylenediaminetetraacetic acid (EDTA), is demonstrated. Pulsed amperometric detection scheme is applied in a flow-through thin layer electrochemical cell at an Au working electrode. Fluctuation of peak current level at the same flow rate of carrier solution is minimized at this solid working electrode, whereas not at a dropping mercury electrode. Removal of dissolved oxygen can be omitted with this detection method, which is a required step for cathodic detection methods. Also, a group of metal ions can be determined selectively and indirectly with this detection scheme.

공소결법에 의해 제조된 지지체식 평판형 고체산화물 연료전지 성능 특성 (Fabrication and Characteristics of Supported Type Planar Solid Oxide Fuel Cell By Co-firing Process)

  • 송락현
    • 한국재료학회지
    • /
    • 제13권3호
    • /
    • pp.160-168
    • /
    • 2003
  • The co-firing processes for the supported type planar solid oxide fuel cell were investigated. A flat cell of $7.7${\times}$10.8\textrm{cm}^2$ was fabricated successfully by the co-firing process, in which green films were co-sintered in the forms of two layers of anode/electrolyte or of three layers of anode/electrolyte/cathode with gas distributor. A co-fired cell of two layers yielded a power of 200 ㎽/$\textrm{cm}^2$ at 608 ㎷. Its performance loss was mainly due to iR drop in the anodic gas distributor, which was attributed to poor contact between anodic gas distributor and current collector. The performance in the co-fired cell of three layers was much lower than that of two layers, which resulted from the large iR drop and activation overvoltage at the cathodic side. In the co-fired cell of two layers, the impedance analysis indicated that the performance decay during cell operation is due to both anode overvoltage and iR drop at anode side. Also the electrode reaction of the co-fired two layers' cell is considered to be controlled by activation overvoltage within the low current of 50 ㎃.

The influence of EAF dust on resistivity of concrete and corrosion of steel bars embedded in concrete

  • Almutlaq, Fahad M.
    • Advances in concrete construction
    • /
    • 제2권3호
    • /
    • pp.163-176
    • /
    • 2014
  • Essentially, when electrical current flows easily in concrete that has large pores filled with highly connective pore water, this is an indication of a low resistivity concrete. In concrete, the flow of current between anodic and cathodic sites on a steel reinforcing bar surface is regulated by the concrete electrical resistance. Therefore, deterioration of any existing reinforced concrete structure due to corrosion of reinforcement steel bar is governed, to some extent, by resistivity of concrete. Resistivity of concrete can be improved by using SCMs and thus increases the concrete electrical resistance and the ability of concrete to resist chloride ingress and/or oxygen penetration resulting in prolonging the onset of corrosion. After depassivation it may slow down the corrosion rate of the steel bar. This indicates the need for further study of the effect of electric arc furnace dust (EAFD) addition on the concrete resistivity. In this study, concrete specimens rather than mortars were cast with different additions of EAFD to verify the electrochemical results obtained and to try to understand the role of EAFD addition in influencing the corrosion behaviour of reinforcing steel bar embedded in concrete and its relation to the resistivity of concrete. The results of these investigations indicated that the corrosion resistance of steel bars embedded in concrete containing EAFD was improved, which may link to the high resistivity found in EAFD-concrete. In this paper, potential measurements, corrosion rates, gravimetric corrosion weight results and resistivity measurements will be presented and their relationships will also be discussed in details.

Electro-Fenton 반응을 이용한 유독성 유기화합물 처리 (Removal of Toxic Organic Compound using Electro-Fenton Reaction)

  • 박상원
    • 한국환경과학회지
    • /
    • 제13권6호
    • /
    • pp.551-560
    • /
    • 2004
  • The feasibility and efficiency of the hydrogen peroxide produced by an electrolysis cell reactor was investigated, From regulating voltages for the given reaction time, the concentration of the hydrogen peroxide was gradually increased with increasing voltages. Optimal voltage range was found to be 10~15 V. The concentration of hydrogen peroxide was much higher with oxygen gas than without oxygen gas in the cathodic chamber. But there was a little difference in the generating rate of hydrogen peroxide regardless of the presence of nitrogen gas. Under given conditions, the maximum value of ICE(Instantaneous Current Efficiency) was about 38%, and then current density was 74 $mA/\textrm{cm}^2.$ The specific energy consumption was $0.694[kWh/kg-H_2O_2].$ Since Esp (Specific Energy Consumption)was very little value, It did not demand high energy in this system. Using the hydrogen peroxide gained in the experiment, Fenton's reaction was conducted and the removal of nitrobenzene, 3-chlorophenol and dye wastewater was studied. This results were very similar to the Fenton's reaction by using commercial hydrogen peroxide.

표면(表面) 코팅 양극(陽極)과 태양전기(太陽電氣)를 이용한 콘크리트 중의 철근(鐵筋) 부식(腐食) 방지(防止)를 위한 효과 (Effect for Steel Corrosion Protection in Concrete applying Surface Coating Anode and Solar Battery)

  • 김종필;박광필;김성수;정호섭;이승태
    • 자원리싸이클링
    • /
    • 제18권4호
    • /
    • pp.44-51
    • /
    • 2009
  • 양극과 철근과의 사이에 이온의 흐름이 원활하도록 전도성이 우수한 탄소리본전극과 표면코팅을 실기한 후 무공해, 반영구적인 무한태양전기를 전류로 공급한 전기방식에 의한 콘크리트 중의 철근 부식 방지 효과를 알아보기 위하여 복극량, 철근의 복극전위 및 부식속도를 측정하였다. 실험결과 방식을 실시한 모든 대상 시험체가 NACE의 복극량 기준 100 mV 기준을 만족하였으며, 방식을 실시한 경우 복극전위와 부식속도가 안정적인 범위에 있음을 알 수 있었다.

마찰교반용접한 5456-H116 알루미늄 합금 용접부 표면의 기계적 및 전기화학적 특성 (Mechanical and Electrochemical Characteristics of Welding Parts Surface for Friction Stir Welded 5456-H116 Al Alloy)

  • 장석기;김성종
    • 한국표면공학회지
    • /
    • 제41권4호
    • /
    • pp.156-162
    • /
    • 2008
  • Small FRP(fiber-reinforced polymer) fishing ships have numerous problems with the point of the environmental and recycling perspectives. In light of these aspects, aluminum can be used as a material for ship building. It is environmental friendly, easy to recycle, and provides a high added value to fishing boats. In this paper, we report on mechanical and electrochemical characteristics of welding parts for friction stir welded 5456-H116 Al alloy. In friction stir welded at various traveling speeds under the rotation speed of 500 RPM, the best characteristics presented in traveling speed of 15mm/min. The anodic polarizations of base metal and welding metal were observed tendency which current density from the open circuit potential suddenly increase. The cathodic polarization presented concentrated polarization caused by the dissolved oxygen reduction reaction and activation polarization caused by hydrogen generation. From result of Tafel analysis, the corrosion potential of 5456 alloy(Base metal) was lower than that of friction stir welded part, as were its corrosion current densities.

태양광 변환을 위한 p형 GaAs 광전극의 전기적 특성 (Electrical Properties of p-GaAs Photoelectrode for Solar Energy Conversion)

  • 윤기현;이정원;강동헌
    • 한국세라믹학회지
    • /
    • 제32권11호
    • /
    • pp.1262-1268
    • /
    • 1995
  • Photoelectrochemical properties of p-GaAs electrode have been investigated. I-V characteristic shows that the cathodic photocurrent is observed at -0.7 V vs. SCE. The photoresponse at near 870~880nm wavelength indicates that the photogenerated carriers contibuted to the observed current. The maximum converson efficiency of 35% is obtained for a Xe lamp light source at 400nm. In C-V relation, capacitance peaks appeared at the frequencies of 100Hz and 300Hz due to the activation of the interfacial states which exist at the energy level corresponding to the one-third of the GaAs band gap. The difference of about 1.1V between flatband potential (Vfb) from the Mott-Schottky method and onset voltage from I-V curve is observed due to the trap of carriers at the interfacial states in the boundary between GaAs and electrolyte. In case of WO3 deposited p-GaAs electrode, higher positive onset current and photocurent density are obtained. This can be explained by the fact that carriers are generated by light penetrated into the WO3 thin flm as well as p-GaAs substrate and then move into the electrolyte effectively.

  • PDF

해수 환경하에서 알루미늄합금(5083F)의 외부전원법에 의한 최적 방식전위 결정에 관한 연구 (Investigation on Optimum Protection Potential Decision of Al Alloy(5083F) in Sea Water by Impressed Current Cathodic Protection)

  • 김성종;감정일;김종신
    • 한국표면공학회지
    • /
    • 제40권6호
    • /
    • pp.262-270
    • /
    • 2007
  • Recently, there has been a new appreciation of aluminum alloys as materials that are capable of reducing the environment load. This is because aluminum alloys are lightweight, easy to recycle, permit miniaturization, and have environmental friendly properties. In this study, we investigated the mechanical and electrochemical properties of 5083F aluminum alloys using slow strain rate test(SSRT) and potentiostatic tests under various potential conditions. In the potentiostatic tests, the current density in the potential range from -0.7 to -1.4V after 1,200 s was low. After considering the results of the potentiostatic tests, maximum tensile strength, yield strength, elongation, time-to-fracture, observation of fractured specimen and fractography analysis, the optimum protection potential range was between -1.3 and -0.7V(Ag/AgCl).

Kinetic Study of the Electrooxidation of Mefenamic Acid and Indomethacin Catalysed on Cobalt Hydroxide Modified Glassy Carbon Electrode

  • Saghatforoush, Lotfali.;Hasanzadeh, Mohammad.;Karim-Nezhad, Ghasem.;Ershad, Sohrab.;Shadjou, Nasrin.;Khalilzadeh, Balal.;Hajjizadeh, Maryam.
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권6호
    • /
    • pp.1341-1348
    • /
    • 2009
  • Electrocatalytic oxidation of two anti-inflammatory drugs (Mefenamic acid and Indomethacin) was investigated on a cobalt hydroxide modified glassy carbon (CHM-GC) electrode in alkaline solution. The process of oxidation and its kinetics were established by using cyclic voltammetry and chronoamperometry techniques as well as steady state polarization measurements. Voltammetric studies indicated that in the presence of under study drugs, the anodic peak current of low-valence cobalt species increased, followed by a decrease in the corresponding cathodic current. This result indicates that the drugs were oxidized via cobalt hydroxide species immobilized on the electrode surface via an E$\acute{C}$ mechanism. A mechanism based on the electrochemical generation of Co (IV) active sites and their subsequent consumption by the drugs in question was also investigated. The constants rate of the catalytic oxidation of the drugs and the electron-transfer coefficients reported.