• Title/Summary/Keyword: Cathode ray tube

Search Result 100, Processing Time 0.027 seconds

Measurement of X-ray Quality in Mammography Unit (유방촬영용 X선장치의 선질 특성)

  • Lee, In-Ja;Kim, Jung-Min;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.5-10
    • /
    • 1998
  • In the mammography, X-ray beam quality is one of the most important factors. Using X-ray mammography unit model GE/CGR Senography 600T Senix H.F, Authors studied four subjects. 1. The aluminum attenuation rate in 30 kVp when used with or without compression plate. 2. HVLs at 5 different area of the X-ray field of $26{\sim}32kVp$. 3. HVLs to know the influence of corrected measurement or parallel measurement. 4. Film density with microdensitometer along and cross to the long axis of X-ray tube, in terms of the Heel effect in the X-ray field. The following results were obtained. 1. Beam quality of anode area was harder than cathode area. 2. The dose reduction rate of compression plate was approximately $65.5%{\sim}88.1%$ and the beam quality with compression plate was hardened up to 4kVp accordingly. 3. If the X-ray beam enters the attenuation plate obliquely, HVL was $2.6{\sim}2.9%$ harder than perpendicular to it. 4. Because of heel effect, the film density of cathode area is higher than anode area to film density of 0.5.

  • PDF

A X-ray Tube Using Field Emitter Made by Multi-walled Carbon Nanotube Yarns

  • Kim, Hyun-Suk;Castro, Edward Joseph D.;Kwak, Seung-Im;Ju, Jin-Young;Hwang, Yong-Gyoo;Lee, Choong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.392-392
    • /
    • 2011
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission.$^{1,2}$ CNT yarns have demonstrated its potential as excellent field emitters.$^3$ Extensive simulations were carried out in designing a CNT yarn-based cathode assembly. The focal spot size dependence on the anode surface of the geometric parameters such as axial distance of the electrostatic focus lens from the cathode and the applied bias voltages at the cathode, grid mesh and electrostatic focus lens were studied. The detailed computer simulations using Opera 3D electromagnetic software$^4$ had revealed that a remarkable size of focal spot under a focusing lens triode type set-up design was achieved. The result of this optimization simulation would then be applied for the construction of the CNT yarn based micro-focus x-ray tube with its field emission characteristics evaluated.

  • PDF

A Three-dimensional Magnetic Field Mapping System for Deflection Yoke of Cathode-Ray Tube

  • Park, K.H.;Yoon, M.;Kim, D.E.;Lee, S.M.;Joo, H.D.;Lee, S.D.;Yang, W.Y.
    • Journal of Information Display
    • /
    • v.3 no.4
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we introduce an efficient three-dimensional magnetic field mapping system for a Deflection Yoke (DY) in Cathode-Ray Tube (CRT). A three-axis Hall probe mounted in a small cylindrical bar and three-stepping motors placed in a non-magnetic frame were utilized for the mapping. Prior to the mapping starts, the inner contour of DY was measured by a laser sensor to make a look-up table for inner shape of DY. Three-axis magnetic fields are then digitized by a three-dimensional Hall probe. The results of the mapping can be transformed into various output formats such as multi pole harmonics of magnetic fields. Field shape in one, two and three- dimensional spaces can also be displayed. In this paper, we present the features of this mapping device and some analysis results.

The Effects of Panel Convexity on Visual Performance and Fatigue in Using Cathode-Ray Tube (CRT) Displays (CRT 디스플레이의 패널곡률이 시각작업 수행도와 안피로도에 미치는 영향)

  • Kim, Sang-Ho;Jang, Seong-Ho;Im, Jong-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.27-44
    • /
    • 2003
  • An experiment was carried out to compare the suitability in visual tasks between flat and conventional (convex) cathode-ray tube (CRT) displays. The subjects performed visual search tasks during 2-h for detecting target words among distracters presented on the screen. The subjects' visual performance was evaluated with average time and number of errors made to complete the tasks. Visual fatigue after the search tasks was also evaluated in terms of degradations in accommodative power and subjective ratings. Difference was not found in task time between the two displays, but flat CRT showed a lower number of errors than conventional CRT. The difference in number of errors was statistically significant at 0=0.05. Although there was no difference between the displays in degradations of accommodative power, results from the subjective ratings showed that flat CRT yields less fatigue than conventional CRT. The results partially support the hypothesis that panel convexity of CRT displays has a significant effect on the performance and fatigue during visual tasks and thus flat CRT is the better display than conventional one.

Trends Detection of Display Research Areas by Bibliometric Analysis (과학계량학 기법을 이용한 디스플레이 연구영역의 트렌드 탐지)

  • Ahn, Se-Jung;Shim, We;Lee, June-Young;Kwon, Oh-Jin;Noh, Kyung-Ran
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1343-1351
    • /
    • 2012
  • In this study, trends for five research areas of LED(Light Emitting Diode), OLED(Organic Light Emitting Diode), LCD(Liquid Crystal Display), PDP(Plasma Display Panel) and CRT(Cathode Ray Tube) are investigated using bibliometric analysis. The papers and patents citation data were extracted from Scopus and USPTO databases, respectively. We could figure out the research trends by the number of publications and citation information. We prospect the current interests and future trends by investigating the development process of the 5 research areas as function of time.

A Study on the Structural Design Approach to Improve Shockproof Characteristic in Cathode Ray Tube (음극선관의 내충격 특성 향상을 위한 구조 설계에 관한 연구)

  • Park, Sang-Hu;Kim, Won-Jin;Lee, Boo-Youn
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.100-105
    • /
    • 2000
  • In this study the structural design concepts of main parameters of a Cathode Ray Tube(CRT) such as frame spring and shadow mask were proposed to guarantee a failure-proof CRT under mechanical shock. With computer simulation and experiments some information on the structural design concept was obtained as followings: the frame and the shadow mask of the CRT needed designing to increase strength so double-beads shape at the corner of frame was newly designed for it, And the spring which interconnected frame with panel glass was required to deform elastically for the purpose of absorbing the shock energy in the direction of drop. A new type of spring 'twisting spring' was designed to achieve the flexibility in that direction. By using it the deformation energy of a shadow mask could reduced to some degree. To accomplish those simulations commerical codes Pam-Crash and I-DEAS were used and a typical CRT was analyzed as an example to prove the usefulness of this study.

  • PDF

Reduction of Microphonic Phenomenon in Cathode Ray Tube by Finite Element Analysis (유한요소해석을 활용한 전자관(Cathod Ray Tube)의 Microphonic 현상개선에 관한 연구)

  • 김성대;서장원;김석관;정봉교
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.271-274
    • /
    • 1996
  • TV나 스피커가 부착되는 PC Monitor에서는 스피커에서 나오는 음향에너지로 인한 진동으로 물결무늬모양의 화면떨림현상이 발생하는데 이를 감소시키기 위해 본 연구에서는 모니터에서의 스피커 부착부분에 대한 개선이 아닌 CRT 자체를 개선하여 어떤 형태의 모니터에 장착하여도 Microphonic현상이 최소화될 수 있는 CRT를 개발하고자 한다. 본 연구에서는 15" CRT를 대상으로 Microphonic현상의 원인규명과 개선안을 도출하였다. Microphonic현상의 주파수분석과 모드분석을 통해 원인을 규명하고 중요부품을 위주로 유한요소해석모델을 구현하였으며 이를 이용하여 중요인자 중 개선이 쉬운 스프링과 프레임에 대한 형상개선을 통해 Microphonic현상수준을 크게 개선하였다. 특히 17" 프레임에 대한 구체적인 개선형상은 실험계획법을 사용하여 도출하였다. 15" GoldStar CRT의 경우는 동일모델에서 최고수준으로 현재 생산 판매되고 있다. 현재 생산 판매되고 있다.

  • PDF

Evaluation of color CRT monitor by MTFA (MTFA에 의한 칼라 CRT의 화질 평가)

  • 김태희
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.205-211
    • /
    • 1998
  • The MTF(modulation transfer function) measuring system with a linear CCD(charge coupled-device) was constructed to cvaluate a color CRT(catode ray tube). The measured MTF values were corrected by considering the spectral response and the pixel sizes of CCD. The effects of a spot size, video bandwidth, pitch of shadow mask holes, display luminance, and ambient illumination on image quality were studied. The uniformity of resolution and the contrast Ioss by ambient light of the color CRT monitor were measured, and the results were analyzed by MTFA(modulation threshold area).

  • PDF