• Title/Summary/Keyword: Cathode

Search Result 2,916, Processing Time 0.029 seconds

Development of Multiwire Proportional Counter for Measurement of Environmental-level Alpha Particles (환경준위 알파입자측정을 위한 다중선 비례계수기 개발(I))

  • Oh, Pil Jae;Park, Tae Soon;Lee, Min Kie;Kim, Kyung Hwa
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.262-269
    • /
    • 1996
  • The muiltiwire proportional counter for the measurement of low-level and environmental $\alpha$ particles emitting nuclides was developed. External dimension of the devloped multiwire proportional counter is $350{\times}290{\times}30mm$ and the sensitivity area is $250{\times}200mm$. The wall material of the detector was selected the stainless steel to prevent the deformation by external impact and to obtain minimum background. The anode and cathode wires were used the stainless steel material of diameter $50{\mu}m$. The spacing of each wires are 10.0mm, 5.0mm and the numbers of total wire are 21, 42 lines, respectively. The multiwire proportional counter was designed that the measurement source is placed within the detector to prevent the wall absorption effect and the efficiency variation by various source heights. The characteristics of the developed detector have been investigated to obtain the plateau, operating voltage, background, counting efficiency, position sensitivity and energy resolution etc. For the $^{241}Am$ nuclide, the calculated LLD(Lower Limit of Detection) is 5.0mBq/L which is lower than 40mBq/L of recommended LLD value by ISO(International Organization for Standardization).

  • PDF

Role of Electrode Reaction of Electrolyte in Electrokinetic-Fenton Process for Phenanthrene Removal (동전기-펜턴 공정에서 전해질의 전극반응이 처리효율에 미치는 영향)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • The effects of electrolytes were investigated on the removal efficiency when several different electrolytes were used to change the electrode reaction in an electrokinetic (EK)-Fenton process to remediate phenanthrene-contaminated soil. Electrical potential gradient decreased initially due to the ion entrance into soil and then increased due to the ion extraction from soil under the electric field. Accumulated electroosmotic flow was $NaCl>KH_2PO_4>MgSO_4$ at the same concentration because the ionic strength of $MgSO_4$ was the highest and $Mg(OH)_2$ formed near the cathode reservoir plugged up soil pore to inhibit water flow. When hydrogen peroxide was contained in electrolyte solution, removal efficiency increased by Fenton reaction. When NaCl was used as an electrolyte compound, chlorine ($Cl_2$) was generated at the anode and dissolved to form hypochlorous acid (HClO), which increased phenanthrene removal. Therefore, the electrode reaction of electrolyte in the anode reservoir as well as its transport into soil should be considered to improve removal efficiency of EK-Fenton process.

Removal of Cr, Pb and Cd from Reservoir Sediment by Electrokinetic Technique (동전기를 이용한 유수지 오염 퇴적토내 Cd, Pb 및 Cr제거)

  • Shin, Hyun-Moo
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.1
    • /
    • pp.68-77
    • /
    • 2009
  • For the reservoir sediment highly contaminated with total Cr, Pb, and Cd, the applicability of electrokinetic remediation method was evaluated. Also, BCR sequential extraction method was adopted to compare the heavy metal speciation in between before and after electrokinetic reaction that is operated under constant current condition for the sediment. After reaction, total Cr and Pb moved toward the direction of anode, while Cd tended to cathode and stayed highest in the midst of sediment specimen. From the BCR sequential extraction analysis, it was known that for total Cr and Pb the residual fraction that showed high fraction before reaction decreased and changed to the oxidation fraction. On the other hand, for Cd the fraction of exchangeable/carbonate that dominated most fractions before reaction changed to the residual and oxidation fractions.

The effects of solenoid magnet on plasma extraction in Filtered Vacuum Arc Source (FVAS) (자장여과 아크 소스에서 각 전자석이 플라즈마 인출에 미치는 영향)

  • 김종국;변응선;이구현;조영상
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.431-439
    • /
    • 2001
  • In this paper, the a-Diamond films were synthesized using filtered vacuum arc source (FVAS), FVAS was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were composed of one permanent magnet and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Cathode was made of graphite with 80 mm in diameter. The effects of solenoid magnet on plasma extraction were investigated by computer simulation and experiment using Taguchi's methode. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. The beam current density was 3.2 mA/$\textrm{cm}^2$ and average deposition rate was 5 $\AA$/sec when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, 5 A, and 5 A, respectively. The beam current density and the efficiency of beam transportation were increased with the positive bias voltage of the plasma duct.

  • PDF

Vacuum Web-coater with High Speed Surface Modification Equipment for fabrication of 300 mm wide Flexible Copper Clad Laminate (FCCL) (초고속 대면적 표면 처리 장치가 부착된 300 mm 폭 연성 동박적층 필림 제작용 진공 웹 코터)

  • Choi, H.W.;Park, D.H.;Kim, J.H.;Choi, W.K.;Sohn, Y.J.;Song, B.S.;Cho, J.;Kim, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2007
  • Prototype of $800{\ell}$ vacuum web coater (Vic Mama) consisting of ion source with low energy less than 250 eV for high speed surface modification and 4 magnetron sputter cathodes was designed and constructed. Its performance was evaluated through fabricating the adhesiveless flexible copper clad laminate (FCCL). Pumping speed was monitored in both upper noncoating zone pumped down by 2 turbo pumps with 2000 l/sec pumping speed and lower surface modification and sputter zone vacuumed by turbo pumps with 450 1/sec and 1300 1/sec pumping speed respectively. Ion current density, plasma density, and uniformity of ion beam current were measured using Faraday cup and the distribution of magnetic field and erosion efficiency of sputter target were also investigated. With the irradiation of ion beams on polyimide (Kapton-E, $38{\mu}m$) at different fluences, the change of wetting angle of the deionized water to polyimide surface and those of surface chemical bonding were analyzed by wetting anglometer and x-ray photoelectron spectroscopy. After investigating the deposition rate of Ni-Cr tie layer and Cu layer was investigated with the variations of roll speed and input power to sputter cathode. FCCL fabricated by sputter and electrodeposition method and characterized in terms of the peel strength, thermal and chemical stability.

A Study on Process Performances of Continuous Electrodeionization with a Bipolar Membrane for Water Softening and Electric Regeneration (바이폴라막을 이용한 연수용 전기탈이온의 공정 효율 및 전기적 재생에 관한 연구)

  • Moon, Seung-Hyeon;Hong, Min-Kyoung;Han, Sang-Don;Lee, Hong-Joo
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.210-218
    • /
    • 2007
  • CEDI-BPM(Continuous Electrodeionization-Bipolar Membrane) has advantages due to high ion permselectivity through ion exchange membranes and the production of $H^+$ and $OH^-$ ions on the bipolar membrane surfaces for regeneration of ion exchange resin during electrodeionization operation. In this study, hardness materials were removed by the CEDI-BPM without scale formation and the ion exchange resins were electrically regenerated during the operation. The adsorption characteristic of ion exchange resin surface, the influence of flow rate on the hardness removal and electric regeneration were investigated in the study. The removal efficiency of Ca was higher than that of Mg in the CEDI-BPM, which was related to the high adsorption capacity of Ca on the cation exchange resin. With increasing flow rate, the flux of Ca and Mg was enhanced by the permselectivity of a cation exchange membrane. In the electric regeneration of CEDI-BPM, it was shown that the regeneration efficiency was higher with a lower regeneration potential applied between cathode and anode.

Study of carbon nanotube cathode fabricated by screen printing on field emission properties (스크린 인쇄법으로 제작한 탄소나노튜브 캐소드의 전계방출 특성에 관한 연구)

  • 조영래
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.27-27
    • /
    • 2003
  • 최근 탄소나노튜브를 전계방출 표시소자(FED, field omission display)용 에미터 재료로 사용한 캐소드 개발에 대한 연구가 활발히 진행되고 있다. 캐소드전극으로는 투명전도성 반도체 박막인 ITO를 사용하고, 에미터용 재료로는 탄소나노튜브를 사용해서 스크린 인쇄법으로 2극(diode type)형 전계방출 소자용 캐소드를 제작하였다. 본딩재(bonding materials)의 종류와 공정변수를 달리해서 에미터용 탄소나노튜브와 ITO 캐소드 전극 사이의 전기적 접촉방법을 변화시켰을때 탄소나노튜브 캐소드의 전계방출 특성을 체계적으로 연구하였다. 첫째로, 본딩재의 전기전도성 (electrical conductivity)을 변수로 해서 탄소나노튜브 에미터의 전계강화(fold enhancement) 효과를 연구한 결과 본딩재의 구성 성분중 부도체(insulator)의 분율이 높을수록 전계강화 효과가 크게 나타남을 확인하였다. 두 번째로, ITO박막 캐소드전극과 탄소나노튜브 잉크 사이에 중간층(inter layer)을 형성시켜서 중간층이 전계방출 특성에 미치는 영향을 연구하여, 중간층의 존재가 탄소나노튜브의 전계방출 전류의 균일성과 전류밀도의 증가에 기여하는 것을 확인하였다. 본 연구의 결과 전계방출 전류가 안정적이면서 동시에 전계방출 효율이 크게 개선된 탄소나노튜브 캐소드를 제작하는 공정기술이 개발되었다. 개발된 기술은 기존의 방법에 비해서 탄소나노튜브 캐소드의 진공패키징시 아웃개싱(outgassing)의 양도 현격하게 작았으며, 에미터와 캐소드 전극 사이의 본딩력(adhesion)도 우수해서 항후 탄소나노튜브 전계방출 표시소자의 개발에 크게 기여할 것으로 판단된다.luminum 첨가량이 증가함에 따라 세라믹 수율도 증가하였음을 확인하였다. 합성된 aluminum-contained polycarbosilane은 20$0^{\circ}C$에서 1시간 동안 불융화과정을 거쳐 환원 및 진공 분위기에서 고온 열처리하였으며 이로부터 얻어진 시료에 대해 XRD분석을 수행하였다. SEM과 TEM을 이용하여 미세구조를 관찰하였다./100 duty로 구동하였으며, duty비 증가에 따라 pulse의 on-time을 고정하고 frequency를 변화시켰다. dc까지 duty비가 증가됨에 따라 방출전류의 양이 선형적으로 증가하였다. 전압을 일정하게 고정시키고 각 duty비에서 시간에 따라 방출전류를 측정한 결과 duty비가 높을수록 방출전류가 시간에 따라 급격히 감소하였다. 각 duty비에서 방출전류의 양이 1/2로 감소하는 시점을 에미터의 수명으로 볼 때 duty비 대 에미터 수명관계를 구해 높은 duty비에서 전계방출을 시킴으로써 실제의 구동조건인 낮은 duty비에서의 수명을 단시간에 예측할 수 있었다. 단속적으로 일어난 것으로 생각된다.리 폐 관류는 정맥주입 방법에 비해 고농도의 cisplatin 투여로 인한 다른 장기에서의 농도 증가 없이 폐 조직에 약 50배 정도의 고농도 cisplatin을 투여할 수 있었으며, 또한 분리 폐 관류 시 cisplatin에 의한 직접적 폐 독성은 발견되지 않았다이 낮았으나 통계학적 의의는 없었다[10.0%(4/40) : 8.2%(20/244), p>0.05]. 결론: 비디오흉강경술에서 재발을 낮추기 위해 수술시 폐야 전체를 관찰하여 존재하는 폐기포를 놓치지 않는 것이 중요하며, 폐기포를 확인하지 못한

  • PDF

Phase Evolution in LiMO2(M=Co,Ni) Cathode Materials for Secondary Lithium Ion Batteries : Effect of Temperature and Oxygen Partial Pressure (리튬 2차 전지용 양극활물질 LiMO2(M=Co,Ni)의 온도와 산소 분압에 따른 상전이 거동)

  • Huang, Cheng-Zhu;Kim, Ho-Jin;Jeong, Yeon-Uk;Lee, Joon-Hyung;Kim, Jeong-Joo
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.4
    • /
    • pp.292-297
    • /
    • 2005
  • $LiMO_{2}(M=Co,Ni)$ samples were synthesized with $Li_{2}CO_{3},\;Co_{3}O_{4}$, and NiO by the solid-state reaction method. In the case of $LiCoO_{2}$, at low temperature$(T=400^{\circ}C)$ spinel structure was synthesized and the obtained spinel phase was transformed to layered phase at high temperature$(T\ge600^{\circ}C)$. The phase transition behaviors of $LiCoO_{2}$ were investigated with various heating temperature and time. The rate of transition was directly proportional to the concentrations of reactant, and activation energy of reaction was around 6.76 kcal/mol. When CoO(rock salt structure) was used as a starting material instead of $Co_{3}O_{4}$(spinel structure), layered structure of $LiCoO_{2}$ was obtained at low temperature. In the case of $LiNiO_{2}$ the transition from layered structure to rock salt structure occurred easily by disordering/ordering reaction, but did not occur in $LiCoO_{2}$. The difference in metal ion radii in $LiCoO_{2}$ and $LiNiO_{2}$ results in different behaviors of phase transitions.

Fabrication of Small SOFC Stack Based on Anode-Supported Unit Cells and Its Power Generating Characteristics (음극지지형 단전지를 사용한 소형 SOFC 스택의 제조 및 출력특성)

  • Jung, Hwa-Young;Kim, Woo-Sik;Choi, Sun-Hee;Kim, Joosun;Lee, Hae-Weon;Ko, Haengjin;Lee, Ki-Chun;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.10 s.269
    • /
    • pp.777-782
    • /
    • 2004
  • In this research, $5\times5cm^2$ unit cells were fabricated via liquid condensation process and uniaxial pressing followed by the screen printing of electrolyte and cathode layer. The SOFC stack was assembled with unit cells, gasket-type sealant and metal interconnect. The stack was designed to have a single column with internal-manifold and cross-flow type gas-channels. The SOFC stack produced 15 W, which is $50\%$ of the maximum power being expected from the maximum power density of the unit cell. Controlling factors for the proper operation of the SOFC stack and other designing factors of stack manifold and gas channels were discussed.

Electricity Production by Metallic and Carbon Anodes Immersed in an Estuarine Sediment (퇴적토에 담지된 금속 및 탄소전극에 의한 전기 생산 특성)

  • Song, Hyung-Jin;Rhee, In-Hyoung;Kwon, Sung-Hyun;Cho, Dae-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3731-3739
    • /
    • 2009
  • One-chambered sediment cells with a variety of anodic electrodes were tested for generation of electricity. Material used for anodes was iron, brass, zinc/iron, copper and graphite felt which was used for a common cathode. The estuarine sediment served as supplier of oxidants or electron-producing microbial habitat which evoked electrons via fast metal corrosion reactions or a complicated microbial electron transfer mechanism, respectively. Maximum power density and current density were found to be $6.90\;W/m^2$ (iron/zinc) and $7.76\;A/m^2$ (iron), respectively. Interestingly, copper wrapped with carbon cloth produced better electric performance than copper only, by 60%, possibly because the cloth not only prevented rapid corrosion on the copper surface by some degrees, but also helped growing some electron-emitting microbes on its surface. At anodes oxidation reduction potential(ORP) was kept to be stationary over time except at the very initial period. The pH reduction in the copper and copper/carbon electrodes could be a sign of organic acid production due to a chemical change in the sediment. The simple estimation of interfacial, electrical resistances of electrodes and electrolyte in the sediment cell that a key to the electricity generation should be in how to control corrosion rate or microbial electron transfer activity.