• Title/Summary/Keyword: Catheter

Search Result 1,102, Processing Time 0.03 seconds

Development of Controllable Cannular Catheter using Bio Shape Memory Alloy (SMA) during Percutaneous Minimally Invasive Spine Surgery (경피적 최소침습 척추시술 중 디스크 내에서 방향제어가 가능한 Bio-SMA 캐뉼라 카테터의 개발)

  • Kim, Cheol-Woong
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.378-383
    • /
    • 2007
  • As the Minimally Invasive Surgery (MIS) is developed, an interventional procedure becomes the major of the spine surgery in the world. Despite of the use of the expensive medical equipments, the success chance of the nucleoplasty is about 30%. The reason is that the shape of the cannular needle is similar to that of the conventional injector and looks like the straight. Because the tip of these straight needles is not able to reach in the vicinity of the disc bulging or the protrusion, which are the cause of the low back pain and because the far indirect plasma discharge results in the decompression, the nucleoplasty has the limit. Many incurable diseases has not been solved due to the unexistence of the advanced technique for the MIS human body cannula device. If 3-D direction controllable cannular catheter (whose direction is accurately controlled after inserting into the bodies to cure the lesion) is developed, it is expected that new devised cannular catheter can cure many incurable diseases simultaneously. Therefore, the aims of this research are to develop the new devised cannular catheter of SMA direction controller for the medical situation, which has been produced through many previous trial-error procedures, and to produce the commercial medical device.

  • PDF

Continuous Irrigation of Brain Abscess Using a Double Lumen Catheter - Technical Note - (이중 도관을 이용한 뇌농양의 지속적 세척술 - 수술 수기 -)

  • Park, Jae-Hyo;Yoo, Do-Sung;Kim, Dal-Soo;Huh, Pil-Woo;Cho, Kyoung-Suok;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.10
    • /
    • pp.1328-1332
    • /
    • 2000
  • We present a modified method for the treatment of brain abscess. The double lumen extraventricular drainage (EVD) catheter which was developed for the intracerebral hematoma management, was applied for the treatment of brain abscess drainage. We placed the double lumen EVD catheter into the abscess cavity by free-hand technique and irrigated the abscess cavity continuously with antibiotics solution for 7 days. Simultaneous intravenous antibiotics was administered for 4 weeks. The continuous irrigation with double lumen catheter was found to be safe and effective treatment modality in the brain abscess.

  • PDF

Real-Time Monitoring of Catheter-Related Biofilm Infection in Mice

  • Liu, Xu;Yin, Hong;Xu, Xianxing;Cheng, Yuanguo;Cai, Yun;Wang, Rui
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.10
    • /
    • pp.1728-1733
    • /
    • 2015
  • This study was done to establish a mouse model for catheter-related biofilm infection suitable to bioluminescence imaging (BLI). Biofilm formation of Pseudomonas aeruginosa (P. aeruginosa) Xen5 grown on catheter disks in vitro and in an implanted mouse model was real-time monitored during a 7-day study period using BLI. The numbers of integrated brightness (IB) and viable bacterial count (VBC) in the biofilm disks in vitro were highest at 24 h after inoculation; the IB of biofilm in vivo was increased until 24 h after implantation. A statistical correlation was observed between IB and VBC in vitro by linear regression analysis. The actual VBC value in vivo can be estimated accurately by IB without sacrifice. In addition, we monitored the change in white blood cells (WBCs) during infection. The number of WBCs on day 7 was significantly higher in the infection group than in the control group. This study indicates that BLI is a simple, fast, and sensitive method to measure catheter biofilm infection in mice.

Giant Right Atrial Thrombi Formation Associated with Hemodialysis Catheter Placement in a Dog

  • Shin, Du-Ree;Yang, Hyuck-Joo;Kim, Hye-Young;Song, Kun-Ho;Seo, Kyoung-Won
    • Journal of Veterinary Clinics
    • /
    • v.34 no.6
    • /
    • pp.478-480
    • /
    • 2017
  • A Cocker spaniel (7-year-old, female) was presented with one week of anorexia, halitosis, oral ulcer, intermittent vomiting, acute weight loss and 3-day history of oliguria. The patient was diagnosed with acute on chronic kidney disease and pancreatitis. Hemodialysis was continued three times a week (total 7 sessions) with improved clinical signs and kidney panel, but presented with another episode of abdominal distention, respiratory distress, and large bowel diarrhea. Echocardiography revealed nearly totally occlusive thrombus in the cranial vena cava, as well as a right atrial mass of approximately $2cm{\times}1cm$. The patient was treated with catheter removal, thrombolysis and anticoagulation therapy with recombinant tissue plasminogen activator. During anticoagulation therapy, size of atrial thrombus was not changed and heart function was not improved after treatment. Since clinical signs were deteriorated, the patient was euthanized by owner's request. Catheter-related giant thrombus in right atrium is a rare complication and treatment guideline for atrial thrombus does not exist. This case is first report of hemodialysis catheter-induced thrombus in Korea.

Effects of a Short Message Service Intervention on Adherence to Maximal Sterile Barrier Precautions and Catheter-Related Blood Stream Infections (최대한의 멸균 차단법의 이행도와 중심정맥관 관련 혈류감염 발생에 대한 단문문자메시지 중재 효과)

  • Kang, Moon-Hee;Kim, Dong-Oak
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.18 no.2
    • /
    • pp.244-250
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the effect of a short message service intervention on adherence to maximal barrier precautions (MBP) and catheter-related blood stream infections. Method: The data were collected from March to September, 2008, at an 826-bed university-affiliated hospital in Daejeon. The study participants were 24 physicians who were inserting central catheters and 133 patients (control group 78 and intervention group 55) with central catheter insertions. The researcher sent the message (adherence to MBP and optimal recommendations) to each internal medicine doctor using the short message service (SMS) for cellular phones. Messages were sent monthly for 3 months. Data were analyzed by chi-square test and t-test using SPSS 12.0 windows program. Result: Adherence to maximal barrier precautions was significantly increased from 44.9% to 69.1% (p=.006) after the SMS intervention. But changes in the rate of CRBSI (catheter related blood stream infection) between the intervention group (1.89) and the control group (4.45) were not significant (p=.323). Conclusions: The results indicate that the SMS intervention is effective in increasing the adherence to maximal barrier precautions and the SMS intervention can be recommended for utilization in infection control nursing practice.

Soft Tissue Response of Rabbit Larynx to Implanted Foley Catheter for Short Duration (토끼 후두내 삽입한 풍선도관에 대한 단기 조직 반응)

  • Yoo, Young-Sam;Choi, Chan;Kim, Dong-Won
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.1
    • /
    • pp.34-39
    • /
    • 2011
  • Objectives : This study was aimed to investigate soft tissue reaction such as inflammation, immune reaction of rabbit larynx to implanted foley catheter. Methods : After 8 rabbits were anesthetized, their thyroid cartilage and trachea were exposed through a skin incision and a 6 French foley catheter was inserted into the thyroid cartilage via cricothyroid membrane and ballooned with normal saline (0.1 mL). The other end of catheters were ligated and cut. The wound was closed keeping catheter under the skin. Two rabbits were used as normal control Larynges were removed for pathologic examination at 4weeks and 8 weeks of the study respectively, Results : Ten rabbits were euthanized for gross and pathologic examination (5 rabbits after 4 weeks and 5 rabbits after 8 weeks). All rabbits survived the study periods and inflammations or foreign body reactions were minimally found on pathologic examinations. Conclusions : Foley catheter could be useful and safe material for vocal fold medialization in rabbit models.

  • PDF

Effects of Distraction using Operating Doll on Preschool Children's Pain during an IV Catheter Insertion (작동인형을 이용한 관심전환이 정맥주사 시 학령전기 아동의 통증에 미치는 효과)

  • Lee Boon-Sim;Kwon In-Soo
    • Child Health Nursing Research
    • /
    • v.11 no.4
    • /
    • pp.490-497
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate the effect on pain of distraction with an operating doll in preschool children(3-6 years old) during an IV catheter insertion. Method: The research design was a nonequivalent control group posttest design, and the participants were 22 children in the experimental group, and 23 children in the control group. The children were hospitalized for enteritis and pharyngitis in a university hospital. The subjective pain was measured using FACES Pain Rating Scale by self report, and the pain behavior responses were scored using Procedure Behavior Check List by observing a film of the entire procedure, and changes in pulse and oxygen saturation as the physiological pain responses were measured by pulse oximeter. Data were analyzed with the SPSS Win 10.0 program. Result: The degree of subjective pain, pain behavior responses, and changes in pulse during IV catheter insertion were significantly lower in the experimental group. But there was no significant difference in $O_2$ saturation between the two groups. Conclusion: Distraction using an operating doll was effective in decreasing pain during inserting the IV catheter in preschool children.

  • PDF

The Biofilm Eradication Using Gentamicin and Anticoagulants as Catheter-Related Infection Prophylaxis in Hemodialysis Patients : A Systematic Review

  • Natasha, Augustine;Timotius, Kris Herawan
    • Microbiology and Biotechnology Letters
    • /
    • v.47 no.2
    • /
    • pp.173-182
    • /
    • 2019
  • The use of double lumen catheters as a means of hemodialysis access is commonly accompanied with the use of gentamicin as an antibiotic lock. Other antibiotics and anticoagulants are often added to increase the efficacy of gentamicin in order to reduce catheter-related infection and to prevent biofilm formation. This review aimed to evaluate the following: 1) the use of gentamicin in eliminating catheter-related infection and reducing biofilm formation in hemodialysis catheters, 2) the efficacy of additional antibiotics in combination with gentamicin, and 3) the effect of additional anticoagulants to complement the efficacy of gentamicin as the main prophylactic antibiotic lock. We sorted through data from 242 PubMed and ScienceDirect studies, which were then short-listed to 33 studies. Next, they were grouped, extracted, and analyzed qualitatively to fulfil the objectives of this review. Consequently, the use of a gentamicin-lock solution was shown to reduce the incidence of bacteremia; however, it was not strong enough to inhibit the growth of infectious microbes and formation of biofilms. Several bacteria, such as Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, and Klebsiella pneumoniae, have been reported as infectious agents. Combination with other antibiotics also provided no effect in reducing bacterial growth and biofilm formation in catheters. Furthermore, the additional anticoagulants (trisodium citrate and EDTA) were reported to be effective in enhancing the efficacy of gentamicin in avoiding catheter-related infection, bacterial growth, and biofilm formation; thus, the use of gentamicin can be rationalized.

Cantilever형 내시경 작동기의 진동과 제어의 해석

  • 박준형;김종현;이장무
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.761-764
    • /
    • 1995
  • This paper demonstrates the feasibility of utilizing Shape Memory Alloy(SMA) actuators in controlling the motion of micro active catherer. The dynamic behavior of SMA is obtained by several experiments for the design of the controller. Two different type of structures which realize catheter are proposed. Each prototype of micro active catherer is fabricated, and its control performance which used the designed controller is investigated. The results obtained show the potential of the SMA as viable means for actuating the micro active catheter.

  • PDF

Design of the Cardiac Output Measurement Module using Swan-Ganz Cathetar (Swan-Ganz Cathetar를 이용한 Cardiac Output 측정 모듈 개발에 관한 연구)

  • Jeong, Yong-hyun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.549-552
    • /
    • 2009
  • 본 논문에서는 심폐기능에 이상이 있는 중환자의 지속적인 감시와 진단을 위한 방법으로 Swan-Ganz Catheter를 체내에 삽입하여 심박 출량과 혼합정맥혈 산소포화도를 기존 장비들보다 정밀하게 측정할 수 있는 모듈을 개발하고자 한다. Swan-Ganz Catheter에는 두 개의 온도센서와 한개의 압력센서를 포함하고 있으며 이를 통해 입력되는 센서 값을 세밀하게 수집하고 이를 기반으로 일회 심박 출량, 전신 및 폐혈관저항, 산소소모량 등을 계산하여 환자의 상태를 보다 정확하게 진단 및 치료가 가능하게 한다.

  • PDF