• Title/Summary/Keyword: Catenary-Current Collection

Search Result 89, Processing Time 0.028 seconds

Analysis on the Current Collection Characteristics of Korean High-Speed Train in High-Speed Track and Conventional Lines (고속선 및 기존선에서 한국형 고소열차의 집전특성 분석 -판토그라프-가선 간 접촉력 경향을 중심으로-)

  • Mok Jin-Yong;Kim Young-Guk;Park Choon-Soo;Kim Ki-Hwan,;Lee Sung-Ho,
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.595-601
    • /
    • 2004
  • The pantograph for Korean High Speed Train was developed and had been evaluating by through 'G7-R&D project' for home grown high speed train technology. In this paper, from the point of view in mechanical aspect, comparison study on the current collection characteristics between the KHST pantograph and contact wire in catenary system on the High-Speed Line and Ho-Nam/Kyoung-Bu conventional lines is conducted. A measuring system for the performance and mechanical characteristics of the KHST pantograph is used for this study, which was developed and installed on the Proto-type Korean High Speed Train, and physical characteristics were measured while the KHST runs on the High-Speed Line and conventional lines. Through this study, remarkable variations of characteristics which can affect to a current collection quality of high-speed train are found and analyzed from measured mean contact forces in both tracks.

  • PDF

Current Collection Performance of Catenary System within Tunnel Section (터널구간 가선계의 집전성능)

  • Son Gun-Ho;Lee Seung-Il;Choi Yeon-Sun
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.767-772
    • /
    • 2004
  • A dynamic simulation program of a catenary-pantograph system including tunnel section and transient section is developed in this study. The simulation program can accommodate for the pantograph of two panheads and three d.o.f model. Using the developed program, the dynamic characteristics with a SCHUNK'S WBL 85-PANTOGRAPH is analyzed at the conventional TAEBAEK line and its tunnel section when the catenary system is supported by a tunnel bracket. The simulation results show that the variation of contact force and uplift displacement is allowable in general section and the entrance and exit of a tunnel, but the uplift displacement and the separation ratio within tunnel section is difficult to allow.

  • PDF

A Study on the Interface between a G7 Pantograph and a KTX Catenary System in Preparation for G7 On-line Tests in the Korea High Speed Test Track (고속 시험선 구간에서의 G7 본선 시운전에 대비한 G7 팬터그래프와 KTX 가선계와의 인터페이스 연구)

  • Cho, Yong-Hyeon;Kyung, Jin-Ho;Hur, Shin;Choe, Kang-youn;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.557-570
    • /
    • 2000
  • It is necessary to perform a study on the interrace between a G7 pantograph and a KTX catenary system prior to G7 on-line tests in the Korea High Speed Test Track in order to predict how high current collection quality can be obtained during the on-line tests and check if safety problems shall be caused b)Y the tests or not. According to the simulation results, current collection quality of the G7 pantograph at 350km/h is lower than that of a GPU pantograph at 300km/h, but the contact wire uplifts and average contact forces are within the safe-zone. In addition, the ratio of running speed (350km/h) to safe running. Therefore, the G7 on-line tests at 350km/h in the Korea High Speed Test Track is expected not to cause the safety problem.

  • PDF

an Analysis for the Effects of Changes of Aerodynamic Forces by a High Speed Train entering a Tunnel on a High Speed Catenary System(I) (터널로 진입하는 고속 전철에 의한 공력 변화가 고속 가선계에 미치는 영향 분석(I))

  • 조용현;정흥채;권혁빈
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.333-343
    • /
    • 1999
  • When a high speed train enters a tunnel, wind speed passing through the train in a tunnel section becomes higher due to the reverse flow to the direction of the train. The higher wind speed gives more aerodynamic forces to the pantograph on the train. Therefore, it is necessary to perform aerodynamic and dynamic analyses in order to check whether the current collection of the high speed train, entering the tunnel, still remain permissible or not. In this paper, the aerodynamic analysis has been performed under the assumption that a high speed train at 300 km/h enters a tunnel whose cross sectional area Is 107/㎡ and length is 1000m. In consideration of the aerodynamic analysis results, the dynamic analysis has been performed based on the catenary and pantograph dynamic models in SEOUL-PUSAN high speed rail, using the GASENDO developed by RTRI. In addition, the fatigue life of the contact wire has been reviewed using the Goodman diagram. Based on the analysis results, it is concluded that the increase of the aerodynamic forces on the pantograph in the tunnel section shall not affect characteristics of current collection adversely except that motions of the pantograph may be constrained by bump-stops.

  • PDF

A Study on Dynamic Design of Current Collection System for the Korean High Speed Train (한국형 고속전철 집전 시스템의 동적설계에 관한 연구)

  • Hur, Shin;Kyung, Jin-Ho;Song, Dahl-Ho
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.445-452
    • /
    • 1998
  • The dynamic performance design of catenary-pantograph system which collects current for the next generation Korean high speed train(KHST) was considered. Used was the same dynamic model of the catenary-pantograph system as that of TGV-K which will be introduced for Kyung-bu corridor. Using the model , sensitivity analysis fer design variables were made to improve dynamic performance of KHST system. The results of sensitivity analysis and performance improvement are as follows: (1) It was found that aerodynamic force, tension of contact wire, mass of contact strip, mass of supporting contact strip, mass of clamp, mass of steady arm, and stiffness of plunger were the design variables most influencing the dynamic performance of the system. (2) Pantograph with reductions of 20% aerodynamic force, 34% weight of supporting contact strip, 20% spring constant of plunger, and 34% equivalent mass of steady arm was very possible system for the KHST which will be running at maximum operating speed 350 km/h.

  • PDF

Development of Local Ground Pantograph for Power Supply to Wireless Mountain Trams (무가선 산악트램 급전을 위한 지상 집중식 급전장치 개발)

  • Seo, Sung-il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.268-275
    • /
    • 2020
  • In domestic mountain resort areas, a catenary system cannot be installed for the protection of the natural environment and view. Therefore, mountain trams must be operated wireless. In this study, a local ground pantograph, which supplies electricity to the battery on board, was developed for this purpose, and its performance was verified by tests. The system is installed on ground at stops or repair shops. While a bogie goes to the pantograph, the arms and collection shoes are raised by a spring force to make contact with the collection bar under the bogie so electric power can be supplied to the battery. Because it is a local ground type, it does not require a roof pantograph and catenary system. The system enables the mountain tram to run wireless. In addition, there is no separation and arc because it collects current while standing at stops or shops. The system has a long life because moving contact, which generates wear and damage to shoes, is avoided. The insulation resistance was above the criteria of 10 ㏁, and there was no abnormal temperature increase when a current of 335A was supplied for one hour.

An Experimental Study on the Correlation between Span Types and the Contact Force of the Pantograph for High-speed Train (경간형식과 고속열차 판토그라프 접촉력 특성의 상호관계에 대한 시험적 고찰)

  • Kim Young-Guk;Mok Jin-Yong;Lee Hi-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.5
    • /
    • pp.398-404
    • /
    • 2005
  • In this paper, we introduce the on-line test of the current collection characteristics for HSR 350x(Korea High Speed Train project) that have been performed in the Kyoung-bu high-speed line since 2002. Through the analysis of measured data during on-line test, the variation trend of contact force between pantograph and contact wire of catenary according to the span type, the track conditions and driving patterns is reviewed. In order to analyze the variation trend of contact force, we have checked the span type of catenary in KP 24 - 125 out of Kyoung-bu high speed line and obtained the statistical processing result per each span type. This study shows that the track conditions do not affect on the dynamic performance between pantograph and contact wire catenary, and the span type and the driving pattern are important factors in determining the good interaction between them.

On the Implementation of an Advanced Judgement Algorithm for Contact Loss of Catenary System (전차선의 집전상태 판단 알고리즘 구현)

  • Park, Young;Jung, Ho-Sung;Yun, Il-Kwon;Kim, Wonha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.850-854
    • /
    • 2014
  • Analyzing dynamic performance between pantograph and contact wire depends on mechanical and electrical conditions such as contact force, currents, aerodynamics of pantograph and tension of overhead contact wire. For the characteristic of dynamic performance between pantograph and overhead contact wire, various evaluation systems are used to measuring of the interaction of the contact line and the pantograph. Among the various methods, the contact force and percentage of arcing are intended to prove the safety and the quality of the current collection system on the train. However, these methods are only capable of measuring on the train which are installed measurement systems. Therefore in this paper, a track-side monitoring system was implemented to measure electrical characteristics from active overhead contact wire systems in order to constantly estimate current collection performance of railway operation. In addition, a method to analyze loss of contact phenomena was proposed. According to simulation results, the proposed system was capable of measuring abnormal electrical behavior of pantograph and contact wires on the track-side. The advantage of the proposed system is possible to detect loss of contact or any other electrical abnormalities of all types of trains within sections from sub to sub without the need to install any on-board equipment on trains.

Development of measuring system of dynamic characteristics for tilting pantograph on the Korean Tilting Train (한국형 틸팅열차의 틸팅 판토그래프 동특성 측정시스템 개발)

  • Mok, Jin-Yong;Kim, Seog-Won;Kim, Young-Guk;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.692-697
    • /
    • 2007
  • The current collection system, pantograph, is one of the important subsystems in electric train system, because of it's fatal function and role of supplying power to the train system. Generally, the function of current collection system is evaluated by loss of contact rate between pantograph and contact wire in catenary by measuring arcs, or by statistical method of evaluating minimum mean contact force. The Korean Tiling Train(TTX) has been manufactured by KRRI and Korean domestic companies and is preparing the trial running test of itself. In this paper, we introduce our successful achievement, measuring system and applied methods of dynamic characteristics for the tilting pantograph, developed of by our own technology.

  • PDF

A Study on the Enhancement of Dynamic Follow-up Characteristics of a Pantograph for High-speed Trains (고속전철 집전용 팬더그래프의 동적 추종 특성 향상에 관한 연구)

  • Cho, Yong-Hyeon;Kwon, Tae-Soo;Choe, Kang-Youn;Kim, Seog-Won
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.134-139
    • /
    • 2001
  • Pantographes should follow periodical motions with hanger and span passing frequencies during operation in order to have good dynamic follow-up characteristics. According to the dynamic simulations of a pantograph together with catenary systems, the best current collection performance of a pantograph is obtained when receptance peak frequencies are matched with hanger and span passing frequencies. Based on this principle, design variables of G7 pantograph are selected. However, because a high-speed train may run in the wide range of speeds and induce aero-acoustic noises, the design variables are adjusted to escape from these problems with a little sacrifice of current collection performance.

  • PDF