Multiple congenital ocular defects in a Bedlington terrier dog (Bedlington terrier의 다발성 안기형 1례)

  • Yoo, Sukjong;Ji, Dongbeom;Kim, Hwiyool;Seo, Kangmoon;Jeong, Manbok
    • Korean Journal of Veterinary Research
    • /
    • v.53 no.2
    • /
    • pp.133-136
    • /
    • 2013
  • To report multiple congenital ocular defects in a Bedlington terrier dog aged 2.5 months with blindness. Routine ophthalmic examinations were performed for the clinical signs. Menace responses and cotton ball test were absent in both eyes (OU), but pupillary light reflexes were normal in OU. Slit lamp biomicroscopy reveled corneal dystrophy, posterior subcapsular cataract, microphthalmia in OU and lenticular coloboma in the right eye. In indirect ophthalmoscopy and ultrasonography, retinal detachment and posterior lenticonus were shown in OU. It is the first report of lenticular coloboma and posterior lenticonus in a Bedlington terrier dog.

Description of a novel ultrasound guided peribulbar block in horses: a cadaveric study

  • Leigh, Hannah;Gozalo-Marcilla, Miguel;Esteve, Vicente;Bautista, Alvaro Jesus Gutierrez;Gimenez, Tamara Martin;Viscasillas, Jaime
    • Journal of Veterinary Science
    • /
    • v.22 no.2
    • /
    • pp.22.1-22.9
    • /
    • 2021
  • Background: Standing surgery in horses combining intravenous sedatives, analgesics and local anaesthesia is becoming more popular. Ultrasound guided (USG) peribulbar nerve block (PB) has been described in dogs and humans for facial and ocular surgery, reducing the risk of complications versus retrobulbar nerve block (RB). Objective: To describe a technique for USG PB in horse cadavers. Methods: Landmarks and PB technique were described in two equine cadaver heads (Phase 1), with computed tomography (CT) imaging confirming contrast location and spread. In Phase 2, ten equine cadaver heads were randomised to two operators naive to the USG PB, with moderate experience with ultrasonography and conventional "blind" RB. Both techniques were demonstrated once. Subsequently, operators performed five USG PB and five RB each, unassisted. Contrast location and spread were evaluated by CT. Injection site success was defined for USG PB as extraconal contrast, and for RB intraconal contrast. Results: Success was 10/10 for USG PB and 0/10 for RB (p < 0.001). Of the RB injections, eight resulted in extraconal contrast and two in the masseter muscle (p = 0.47). Conclusions: The USG PB had a high injection site success rate compared with the RB technique; however, we cannot comment on clinical effect. The USG technique was easily learnt, and no potential complications were seen. The USG PB nerve block could have a wide application for use in horses for ocular surgeries (enucleations, eyelid, corneal, cataract surgeries, and ocular analgesia) due to reduced risk of iatrogenic damage. Further clinical studies are needed.

Korean Medicine Treatment for Patients with Grade I-III Hemorrhoids (Goligher Classification): A Case Series (Goligher 분류상 1기-3기에 해당하는 항문질환 환자의 한의치료 증례군보고)

  • Kim, Chan-young;Seoung, Kang-uk;Ahn, Hae-in;Yoon, Young-heum;Kim, Nam-kwen
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.6
    • /
    • pp.1289-1299
    • /
    • 2020
  • Background: Hemorrhoid surgery is a frequently performed surgery in Korea, second only to cataract surgery. However, it has serious complications, including bleeding, infection, anal stenosis, and urinary retention, so active conservative therapies are in need at an early stage. Case summary: Thirteen patients with anal disease complained of main symptoms of pain, bleeding, and prolapse, with additional complaints of itching and mucus discharge. An herbal medicine mixture of Eulja-tang and Hwangryeonhaedok-tang was administered twice daily, and dry cupping therapy, acupuncture, and hot pack placements were administered on pelvic and sacral regions once weekly for four weeks. The symptoms were evaluated before and each week after the treatments. The treatments had statistically significant therapeutic effects. Conclusion: Korean medicine treatment-effectively alleviating the symptoms of anal disease, such as pain, bleeding, and prolapse-may represent an alternative therapy for conservative treatments in the early stages of anal disease.

Placement of an Intraocular Silicone Prosthesis with Evisceration in a Dog with Refractory Glaucoma (난치성 녹내장을 지닌 개에서 안구내용제거술을 통한 안구 내 실리콘 보철물 적용 1례)

  • Kim, Kyung-Hee;Kim, Joon-Young;Choi, Young-Min;Lee, Jong-Hoon;Park, Chang-Hee;Lee, Jung-Ha;Lee, Young-Sun;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.610-613
    • /
    • 2010
  • An 8-year-old male dog weighing 7.9 kg was referred to us for evaluation of exophthalmos and corneal edema of the left eye, on which cataract surgery had been performed 3 years prior. On ophthalmic examination, the left eye showed an extremely high intraocular pressure (47 mmHg), with no menace response, dazzle reflex, or pupillary light reflex. The dog was treated with systemic and topical glaucoma medications. After treatment, corneal edema decreased but IOP did not return to within acceptable limits. Seventeen months later, the dog presented with hyphema, episcleral congestion, and corneal edema attributable to accidental trauma. The owner wished to maintain an attractive ocular appearance, and an intraocular silicone prosthesis (ISP) was thus inserted after the evisceration. Three months postoperatively, a corneal ulcer was detected, but this resolved successfully after prescription of appropriate medication. One year after surgery, no complications related to surgery were evident.

Ophthalmic Findings in 547 Korean Sapsaree Dogs

  • Chae, Je-Min;Kim, Won-Tae;Jeong, Man-Bok;Yi, Na-Young;Park, Shin-Ae;Kim, Se-Eun;Park, Young-Woo;Ha, Ji-Hong;Han, Koog-Il;Seo, Kang-Moon
    • Journal of Veterinary Clinics
    • /
    • v.25 no.6
    • /
    • pp.482-487
    • /
    • 2008
  • This study was performed to investigate the ophthalmic findings of the Korean traditional 'Sapsaree' dogs, and to provide ophthalmic references. Five hundred forty-seven Sapsaree dogs were randomly chosen without any criteria preference. Ophthalmic examination was performed bilaterally using ocular equipments, including slit-lamp biomicroscope, tonometer, direct and indirect ophthalmoscope. The obtained data for ophthalmic findings were analysis by the multivariate linear regression model to identify effects of sex, age and hair coat type. For congenital conditions, the incidence of persistent pupillary membrane (PPM) was the most common defect and there was present 8.8 % whereas for acquired ophthalmic diseases, cataract was the most commonly observed (3.7 %) in Sapsaree dog. Other frequent ocular finding included persistent hyaloid vessel remnant (PHVR, 6.2 %) in congenital conditions, and postinflammatory retinal degeneration (PIRD, 3.1 %) and corneal dystrophy (2.4 %) in acquired ophthalmic diseases. Only one significant effect was age of the Sapsaree for PIRD (P=0.040). There are no any significant effect for sex and hair coat types. This study will provide useful guidelines to clinicians and breeders for the basic ophthalmic information on this breed.

Optical Models of the Finite Schematic Eyes for Presbyopia (노안을 위한 정밀 모형안 설계)

  • Baarg, Saang-Bai
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.439-447
    • /
    • 2008
  • There is a need for a finite schematic presbyopic eye that models vision and image quality under various conditions such as cataract or refractive surgery, as well as near vision corrections with an ophthalmic lens or contact lens. Using recently measured biometric data of presbyopic eyes, new model eyes were designed that are optically and anatomically close to real eyes. The parameters changing significantly with age were incorporated into models for four different age groups. The new model eyes have alpha angle, decentered pupil, aspheric GRIN lens and aspheric retinal surface. It is likely that the new finite presbyopic model eyes will be useful for designing visual instruments such as low vision aids, PALs, IOL and contact lenses, and for the clinical prediction of the retinal image quality of a presbyopic patient.

Demand on Nursing Services in 7 Korean Diagnostic-Related Group (7개 포괄수가 질환군 대상 간호요구도 분석)

  • Choi, Youn Jeong;Lee, Youngjin;Seo, Young Min;Lim, Ji Young
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.24 no.2
    • /
    • pp.151-159
    • /
    • 2017
  • Purpose: The purpose of this study was to identify nursing demands according to general characteristics and diseases of inpatients to whom comprehensive payment systems apply. Methods: This study was designed as a retrospective research study using the electronic medical records of Hospital Information Systems (HIS). Participants were 836 subjects who received seven Diagnostic-Related Group diagnoses among inpatients of one tertiary hospital from January 1, 2015 to June 30, 2015. Data were analyzed using SPSS 23.0. Results: Nursing demand among inpatients'seven Diagnostic-Related Group diagnoses was relatively higher for appendectomy, cataract surgery, and hysterectomy, while there was a significant difference depending on the age, duration of admission, admission path, hospital entry method and Diagnostic-Related Group. Conclusion: The results can be utilized as basic data on accurate nursing demands that reflect various features of patients.

Trifocal versus Bifocal Diffractive Intraocular Lens Implantation after Cataract Surgery or Refractive Lens Exchange: a Meta-analysis

  • Yoon, Chang Ho;Shin, In-Soo;Kim, Mee Kum
    • Journal of Korean Medical Science
    • /
    • v.33 no.44
    • /
    • pp.275.1-275.15
    • /
    • 2018
  • Background: We compared the efficacy between trifocal and bifocal diffractive intraocular lens (IOL) implantation. Methods: Through PubMed, MEDLINE, EMBASE, and CENTRAL, we searched potentially relevant articles published from 1990 to 2018. Defocus curves, visual acuities (VAs) were measured as primary outcomes. Spectacle dependence, postoperative refraction, contrast sensitivity (CS), glare, and higher-order aberrations (HOAs) were measured as secondary outcomes. Effects were pooled using random-effects method. Results: We included 11 clinical trials, with a total of 787 eyes (395 subjects). The trifocal IOL group showed better binocular distance VA corrected with defocus levels of -0.5, -1.0, -1.5, and -2.5 diopter than the bifocal IOL group (All $P{\leq}0.004$). The trifocal IOL group showed better monocular uncorrected distance and intermediate VAs (mean difference [MD], -0.04 logarithm of the minimum angle of resolution [logMAR]; 95% confidence interval [CI], -0.07, -0.01; P = 0.006 and MD, -0.07 logMAR; 95% CI, -0.13, -0.01; P = 0.03, respectively). Postoperative refraction, glare, CS, and HOAs were not significantly different from each other. Conclusion: The overall findings indicate that trifocal diffractive IOL implantation is better than the bifocal diffractive IOL in intermediate VA, and provides similar or better in distance and near VAs without any major deterioration in the visual quality.

Periocular Allergic Contact Dermatitis Associated with the Use of Ofloxacin Ophthalmic Ointment: A Case Report (Ofloxacin 안연고에 의해 유발된 눈주위 알레르기접촉피부염)

  • Jo, Jeong Won;Jeong, Hae Bong;Shin, Young Bin;Kang, Kee Ryeon;Kim, Chi Yeon
    • Korean journal of dermatology
    • /
    • v.56 no.10
    • /
    • pp.624-627
    • /
    • 2018
  • Allergic contact dermatitis is an inflammatory condition associated with periorbital erythema, edema, and pruritus. The periorbital skin is relatively thin compared with the skin over other facial areas; therefore, it is vulnerable to allergen penetration and may show a variety of cutaneous manifestations. Recently, vision enhancement surgery is a widely performed procedure, and the prevalence of senile cataract and glaucoma is increasing. The prevalence of periocular allergic contact dermatitis is increasing secondary to the growing use of topical ophthalmic medications. Several studies in Korea have reported periocular allergic contact dermatitis secondary to the use of topical ophthalmic medications including latanoprost ($Latano^{(R)}$), fluorometholone ($Tolon^{(R)}$), polymyxin B ($Terramycin^{(R)}$), atropine sulfate ($Atropine^{(R)}$), neomycin sulfate ($Cambison^{(R)}$), and befunolol hydrochloride ($Bentos^{(R)}$), among others. However, ofloxacin ($Effexin^{(R)})$-induced allergic contact dermatitis has not been reported in the domestic and/or foreign literature. We report a case of periocular allergic contact dermatitis secondary to the use of ofloxacin ophthalmic ointment.

Double-Pass System (Optical Quality Analysis System) for Analysis of the Multifocal Function of a Diffractive Multifocal Intraocular Lens (Acrysof ReSTOR®) Compared to a Monofocal Intraocular Lens (Acrysof IQ®)

  • Hwang, Ho Sik;Shin, Hye Young;Joo, Choun-Ki
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.110-117
    • /
    • 2014
  • In this study, we objectively determined whether the ReSTOR as a multifocal IOL (intraocular lens) has a multifocal function compared to the IQ as a monofocal IOL in vivo by OQAS (Optical Quality Analysis System). Eighteen patients who had cataract surgery with implantation of ReSTOR (27 eyes) and 15 patients with IQ (21 eyes), were included inthis study. Uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UCNVA)and distance corrected near visual acuity (DCNVA) were measured. After setting the artificial pupil size to 3 mm, we performed 'Optical quality'. We inputted defocus diopters of (objective spherical refraction)(far), (objective spherical refraction-1.25 D)(intermediate),(objective spherical refraction-2.5 D)(near), and (objective spherical refraction-3.5 D)(very near) into 'selected spherical refraction' simulating the optical quality at far, intermediate, and near distance. We changed the pupil size to 5 mm and repeated the same measurements. The UCDVA and CDVA did not show significant differences between the 2 groups. But, the UCNVA and DCNVA of the ReSTOR group were better than those of the IQ group (p=0.000, p=0.000). For 3 mm pupil, at far distance, modulation transfer function (MTF) cut off and point spread function (PSF) width at 50% of ReSTOR were worse than those of IQ (p=0.039, p=0.020). At intermediate distance, MTF cut off, Strehl ratio and PSF width at 50% of ReSTOR were worse than those of IQ (p=0.001, p=0.001, p=0.000). At near distance, MTF cut off of ReSTOR was worse than that of IQ (p=0.033). At very near distance, MTF cut off and Strehl ratio of ReSTOR were worse than those of IQ (p=0.002, p=0.002), but PSF width at 50% of ReSTOR was better than that of IQ. For 5 mm pupil, most parameters at each distance, there was no significant difference between the 2 groups. Only PSF width at 50% of ReSTOR were worse than those of IQ at intermediate distance (p=0.013). It was impossible to show the multifocal function of ReSTOR compared to the IQ byOQAS.