• Title/Summary/Keyword: Case Drop

Search Result 677, Processing Time 0.025 seconds

Challenging a Single-Factor Analysis of Case Drop in Korean

  • Chung, Eun Seon
    • Language and Information
    • /
    • v.19 no.1
    • /
    • pp.1-18
    • /
    • 2015
  • Korean marks case for subjects and objects, but it is well known that case-markers can be dropped in certain contexts. Kwon and Zribi-Hertz (2008) establishes the phenomenon of Korean case drop on a single factor of f(ocus)-structure visibility and claims that both subject and object case drop can fall under a single linguistic generalization of information structure. However, the supporting data is not empirically substantiated and the tenability of the f-structure analysis is still under question. In this paper, an experiment was conducted to show that the specific claims of Kwon and Zribi-Hertz's analysis that places exclusive importance on information structure cannot be adequately supported by empirical evidence. In addition, the present study examines H. Lee's (2006a, 2006c) multi-factor analysis of object case drop and investigates whether this approach can subsume both subject and object case drop under a unified analysis. The present findings indicate that the multi-factor analysis that involves the interaction of independent factors (Focus, Animacy, and Definiteness) is also compatible with subject case drop, and that judgments on case drop are not categorical but form gradient statistical preferences.

  • PDF

Case Drop and Prosodic Structure in Korean

  • Hong, Sung-Hoon
    • Speech Sciences
    • /
    • v.7 no.3
    • /
    • pp.35-51
    • /
    • 2000
  • The goal of this paper is to examine how Case Drop (the drop of the case markers) correlates with the prosodic structure in Korean. On the assumption that intervocalic Lenis Stop Voicing (LSV) applies within the domain of the Accentual Phrase (AP), voicing analyses are performed on intervocalic lenis stop consonants before and after Case Drop. A statistical analysis reveals that the drop of the nominative and accusative case markers significantly alter the AP structure. Pitch values will then be extracted to verify that such changes in the AP structure conform to the pitch properties proposed for the AP (Jun 1993, 1998). The results show that the AP structure suggested by LSV does not always coincide with that imposed by the pitch properties.

  • PDF

A case of foot drop treated with placenta pharmacopuncture (자하거 약침으로 호전된 족하수 환자 치험 1례)

  • Jang, Woo-Seok
    • Journal of Pharmacopuncture
    • /
    • v.12 no.1
    • /
    • pp.99-102
    • /
    • 2009
  • This study was to evaluate a case of foot drop treated with placenta pharmacopuncure. After thirteen times of treatment, I evaluated this case by the angle of dorsiflexion, the total sum of gaiting points, the time of heel standing. As a result of evaluation, the angle of dorsiflexion, total sum of gaiting points, time of heel standing were improved. The placenta pharmacopuncture can be used for foot drop and other peripheral nerve palsy.

Experimental study on the effects of EVA(Ethylene Vinyl Acetate) for solar cell's long-term life (EVA(Ethylene Vinyl Acetate) 수지가 태양전지의 장기적인 수명에 미치는 영향에 관한 실험적 연구)

  • Kim, Seon Yong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.397-401
    • /
    • 2015
  • In this study, analysed the characteristics of power drop and surface damage in solar cell through high temperature and humidity test in the 3 case of EVA(ethylene vinyl acetate) and 2 case ribbon thickness. The solar cells were tested during the 500hr in $85^{\circ}C$ temperature and 85% relative humidity conditions, that excerpted standard of PV Module(KS C IEC-61215). Through the EL(Electroluminescence) shots, specimen's surface have partialy damaged. Before and after high humidity and high temperature test, ribbon thickness $200{\mu}m$ EVA1 case power drop rate was 8.463%, EVA2 case was 6.667%, EVA3 case was 6.373%. In the ribbon thickness $250{\mu}m$ EVA1 case power drop rate was 6.521%, EVA2 case was 8.517%, EVA3 case was 6.019%. EVA3 case was the lowest power and FF(fill factor) drop rate at the 2 case of ribbon thickness, because EVA3 is laerger than EVA1 and EVA2 in thickness, elongation and tensile strength.

Clinical Study on 1 Case of Patient with the Foot Drop Diagnosed as Peripheral Neuropathy (말초신경병증으로 진단된 편측 족하수 환자의 치험 1례)

  • Choi, Sung-Yong;Lee, Seong-Kyun;Gug, Yun-Jai;Kim, Dae-Joong;Lee, Seung-Hyun
    • Journal of Acupuncture Research
    • /
    • v.23 no.1
    • /
    • pp.217-223
    • /
    • 2006
  • Objectives : To see if Clinical study on 1 Case of patient with the foot drop diagnosed as peripheral neuropathy suggest further treatment plan for more effective cure. Methods : To heal foot drop diagnosed as peripheral neuropathy using herbal medicine wooseul-tangkami and electronic acupuncture on the Yangmyung channel(陽明經) selected in The Yellow Emperor's of internal Medicine and on Panggwang channel(膀胱經) considered as painful lesion. Results : we experienced a case of foot drop diagnosed as the peripheral neuropathy the patient was treated by wooseul-tangkami, and electric acupuncture on Yangmyung channel and also Panggwang channel and had a significant improvement in gait ability and the range of motion. Conclusion : Herbal medicine wooseul-tangkami, and electric acupuncture on Yangmyung channel and also Panggwang channel was prescribed in the perpective of oriental medicine when treating foot drop, Wooseul-tangkami is used to remove the wetness-heat evil and had shown significant improvement in gait ability and the range of motion.

  • PDF

A Study on the Temperature Behavior on Impinging Plate of Diesel Spray with Ultra High Pressure (극초고압 디젤분무의 충돌면 온도거동에 관한 연구)

  • Lee Jong Tai;Jeong Dae Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.402-408
    • /
    • 2005
  • The instantaneous temperature behaviors on impinging plate in case of ultra high pressure have been measured and analyzed by using the instantaneous temperature probe and ultra high pressure injection equipment. The temperature drop was largest at P1 which is center of impinging spray and decreased with propagation of spray to the radius direction. The temperature drop was bigger in case of higher temperature of impinging plate. The temperature drop decreased with increase of injection pressure. But decreasing rate of temperature drop was slight over 2,500 bars. Therefore, it was predicted that the fuel evaporation versus the increase of injection pressure was maximum at around 2,500 bars.

A Case Report of Foot Drop in Soyangin Improved with Sukjiwhanggosam-tang (숙지황고삼탕(熟地黃苦蔘湯)으로 호전된 소양인(少陽人) 족하수(足下華) 치험 1례)

  • Han, Da-Nim;Lee, Pil-Jae;Kim, Seong-Ki;Lim, Eun-Chul;Jung, Ji-Eun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.21 no.1
    • /
    • pp.270-277
    • /
    • 2009
  • 1. Objectives The purpose of this case study is to report the effects of Sukjiwhanggosam-tang which is based on the Sasang Constitutional Medicine for the Foot drop caused by peroneal nerve palsy. 2. Methods This patient was treated by Sukjiwhanggosam-tang according to the result of Sasang Constitutional diagnosis. We used Visual analogue scale(VAS), Range of motion(ROM) and Manual Muscle Testing(MMT) to evaluate the improvement of the Foot drop. 3. Results After 20 days treatment, the VAS of Rt. leg & foot hypoesthesia decreased from 10 to 2. The ROM of dorsiflexion of the ankle joint increased from $10^{\circ}$ to $30^{\circ}$ and the grade of MMT increased from 3 to 4. 4. Conclusions This case study shows an efficient result of using Sukjiwhanggosam-tang in the treatment of the Foot drop caused by peroneal nerve palsy.

  • PDF

Bilateral foot drop caused by T12 infectious spondylitis after vertebroplasty: a case report

  • Kim, Dong Hwan;Shin, Yong Beom;Ha, Mahnjeong;Kim, Byung Chul;Han, In Ho;Nam, Kyoung Hyup
    • Journal of Trauma and Injury
    • /
    • v.35 no.1
    • /
    • pp.56-60
    • /
    • 2022
  • The most common cause of foot drop is lumbar degenerative disc herniation, particularly at L4/5. We present a rare case of spinal cord injury accompanied by a thoracolumbar lesion that presented with bilateral foot drop. A 69-year-old male patient presented with sudden-onset severe bilateral leg pain and bilateral foot drop. Radiologic findings revealed T12 spondylitis compressing the conus medullaris. He had undergone vertebroplasty for a T12 compression fracture after a fall 6 months before. A physical examination showed bilateral foot drop, paresthesia of both L5 dermatomes, increased deep tendon reflex, and a positive Babinski sign. An acute bilateral L5 root lesion and a conus medullaris lesion were suspected based on electromyography. A surgical procedure was done for decompression and reconstruction. After the operation, bilateral lower extremity muscle strength recovered to a good grade from the trace grade, and the patient could walk without a cane. The current case is a very rare report of bilateral foot drop associated with T12 infectious spondylitis after vertebroplasty. It is essential to keep in mind that lesions of the thoracolumbar junction can cause atypical neurological symptoms. Furthermore, understanding the conus medullaris and nerve root anatomy at the T12-L1 level will be helpful for treating patients with atypical neurological symptoms.

Case Report of Foot Drop Patient Treated with Electroacupuncture (전침을 이용한 족하수(Foot drop)환자 치험2례)

  • Lee, Jong-Young;Won, Seung-Hwan;Kim, Doo-Yong;Kim, Sung-Hae;Park, Hee-soo;Hwang, Jung-Su
    • Journal of Acupuncture Research
    • /
    • v.22 no.5
    • /
    • pp.161-166
    • /
    • 2005
  • The Foot drop is led by the conditional palsy of dorsal flexor according to some causes. In this case, it is caused by peroneal nerve palsy. It brings the difficulty in waking and standing up. We observed 2 cases of patient with Foot drop. Two patients were treated by the same method and treatment was performed by means of electroacupuncture(2-4Hz frequency, intensity was adjusted so that localized muscle contraction could be seen). As the result, symptoms are improved.

  • PDF

Heat Transfer and Pressure Drop Characteristics of Secondary Refrigerants Applying to Indirect Refrigeration System (간접 냉동 시스템용 2차 냉매의 열전달과 압력강하 특성)

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Jo, Hwan;Yi, Wen-Bin;Jeon, Min-Ju
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.45-50
    • /
    • 2013
  • This paper presents the comparison of heat transfer and pressure drop of various secondary refrigerants (single-phase and two-phase) in the indirect refrigeration system. The main results were summarized as follows: In case of heat transfer, it is useful to use secondary refrigerants in low evaporating temperature region and the heat transfer coefficient of single-phase is larger than two-phase secondary refrigerants. In case of pressure drop, it is useful to use secondary refrigerants in high evaporating temperature region and the pressure drop of two-phase is smaller than single-phase secondary refrigerant. Also, $CO_2$ is the best useful because pressure drop of $CO_2$ among the secondary refrigerants is the smallest.