• Title/Summary/Keyword: Case 2 Water

Search Result 3,815, Processing Time 0.037 seconds

Influence of Water Hardness on Accumulation of Heavy Metals in Kidneys and Livers of Rats (물의 경도가 흰쥐의 신장, 간에서 중금속 축적에 미치는 영향)

  • 한돈희
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.2
    • /
    • pp.51-64
    • /
    • 1988
  • It has been suggested that calcium is only one of many metals that compete with toxic metals in the body. Therefore, this study was carried out to determine the influence of water hardness on accumulation of heavy metals in rats. The seventy-five rats were divided into control and case groups. Case group was subdivided into four subgroups in proportion to the concentration of water hardness respectively, such as, 0, 250, 500, 1000ppm. Control group was fed on only deionized water, but case groups were fed on hard water with ionized heavy metals (Cd 150mg + Pb 300mg + Cu 300mg/l) for 20, 40, 60 days. The concentrations of cadmium, lead and copper were measured by atomic absorption spectrophotometry (Perkin Elmer 2380) in livers and kidneys. The results of the study are summarized as following 1. The concentration of cadmium accumulation showed the tendency of decrease in proportion to water hardness in both livers and kidneys of rats having been fed for only 60 days, respectively. 2. In only livers of rats having been fed for 60 days, essential metal, copper had the tendency of decrease according as hardness in water. 3. It was impossible to compare case with control about the tendency of lead accumulation because there was no difference between the two in livers and kidneys respectively.

  • PDF

A Study on Efficiency of Water Supply through Conjunctive Operation of Reservoirs and Multi-function Weirs in the Nakdong River (낙동강수계 댐과 다기능보의 연계운영을 통한 용수공급효율화에 관한 연구)

  • Ahn, Jung Min;Im, Toe Hyo;Lee, In Jung;Lee, Kyung-Lak;Jung, Kang Young;Lee, Jae Woon;Cheon, Se Uk;Park, In Hyeok
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.2
    • /
    • pp.138-147
    • /
    • 2014
  • In order to determine the best operating rules for the Nakdong River, three cases were applied to analyze the simulated results of water supply capacity by HEC-ResSim model. This study discussed to present the best operating rules for conjunctive operating of existing the dams and new constructed the weirs through system network. The system network was constructed considering the water supply, the river environment and the operating facility. The water supply capacities are separately evaluated for each case applying the best rules. It is case1 that the dams are operated individually, case2 that the dams are operated in conjunction with the others dams, and case3 that dams and weirs are operated in conjunction with the others dams-weirs. Comparing the cases, case 3 has shown the best water supply capacity of the Nakdong River.

Synthesis and Characterization of Sulfonated Polyimide Polymer Electrolyte Membranes

  • Kim, Hyoung-juhn;Morton H. Litt;Nam, Sang-Yong;Shin, Eun-mi
    • Macromolecular Research
    • /
    • v.11 no.6
    • /
    • pp.458-466
    • /
    • 2003
  • Several copolyimides have been synthesized with different combinations of comonomers in order to study the relationship between conductivity and water insolubility. m-Phenylenediamine (m-PDA), an angled comonomer, was introduced into the polymer backbone to increase water absorption, and resulted in higher proton conductivity. 2,2-bis(trifluoromethyl)benzidine (TFMB) was used as the comonomer to promote water insolubility. There is a good correlation between the water uptake and conductivity of the polyimides. The copolyimides that had high water uptake also generated high proton conductivity. Those polyimides had good mechanical properties. The copolyimides that have 27 mol% of TFMB and 9 mol% of m-PDA have reasonable conductivities and are insoluble in water at 90$^{\circ}C$, even though they have lower conductivities than those of the homopolymer.

Prediction of Change in Growth Rate of Algae in Jinhae Bay due to Cooling Water Discharge (냉배수 방류에 따른 진해만의 해조류 성장 속도 변화 예측)

  • Park, Seongsik;Yoon, Seokjin;Lee, In-Cheol;Kim, Byeong Kuk;Kim, Kyunghoi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.308-323
    • /
    • 2021
  • In this study, we aimed to evaluate the environmental changes in Jinhae Bay caused by cooling water using numerical modeling. Cooling water discharge volume from the results of Case 1 (10 m3 sec-1) showed that the environmental changes in Jinhae Bay were extremely insignificant throughout the study period. In the simulation conditions of Case 2 (100 m3 sec-1), there was a decrease in water temperature of approximately 1 - 3℃ within a 5 km radius from the discharge outlet. In Case 3 (1000 m3 sec-1), a decrease in water temperature of up to 4 - 5℃ was observed within a radius of 8 km from the discharge outlet and cooling water discharge spread throughout the Bay. Growth rate of microalgae decreased by up to 15 % in November, whereas it increased by up to 6 % near the Hangam Bay in Case 3. From the above results, we confirmed that the environmental changes in Jinhae Bay due to cooling water discharged from Tongyeong LNG station are extremely insignificant. Moreover, it is expected that cooling water discharge could be utilized as a counter measure for 'red tide bloom' or 'macroalgae growth'.

An Experimental Study on the Performance and the Exhaust Emissions of Gasoline Engine Using Water-Gashol Blends as a Fuel (물-가스홀 혼합물을 연료로 사용한 가솔린기관의 성능 및 배기성분에 관한 실험적 연구)

  • 노상순;배명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.25-38
    • /
    • 1984
  • Since the energy shock in 1973, there have been wide studies for the developments of the alternative energy source, the rationalization of the energy utilization and the energy economy because of the recognition of the limitation of energy source all over the world. This study is experimentally examined in and compared with the engine performance of output, torque and fuel consumption rate, and the exhaust emissions with the change of engine rmp in the cases of using water-gashol blends, gashol and gasoline as a fuel in a conventional 4 cycle 4 cylinder gasoline engine. In the case of using water-gashol blends, it is installed by the exhaust manifold pipe into the intake manifold, and water is injected from nozzle fitted up the air horn of the carburetor. The results are obtained as follows; 1. In the case of an addition with water, the engine output and the torque are little difference with the case of gasoline. 2. The fuel consumption rate is decreased as compared with the case of gasoline. Especially, the decrease in quantity is remarkable at the low rpm. 3. The exhaust emissions are remarkably decreased as compared with the case of gasoline. Especially, decreases of CO and HC in quantity are remarkable at the low rpm, and a decrease of No/sub x/ in quantity is remarkable at the high rpm. 4. There is a moderate condition of operation because the producing factors of NO/sub x/ and CO, HC are contrary to each other.

  • PDF

A study on spatial onset characteristics of flash drought based on GLDAS evaporative stress in the Korean Peninsula (GLDAS 증발 스트레스 기반 한반도 돌발가뭄의 공간적 발생 특성 연구)

  • Kang, Minsun;Jeong, Jaehwan;Lee, Seulchan;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.10
    • /
    • pp.631-639
    • /
    • 2023
  • Flash drought (FD), characterized by the rapid onset and intensification, can significantly impact ecosystems and induce immediate water stress. A more comprehensive understanding of the causes and characteristics of FD events is required to enhance drought monitoring. Therefore, we investigated the FD events took place over the Korean peninsula using Global Land Data Assimilation System (GLDAS) data from 2012 to 2022. We first detected FD events using the stress-based method (Standardized Evaporative Stress Ratio, SESR), and analyzed the frequency and duration of FDs. The FD events were classified into three cases based on the variations in Actual Evapotranspiration (AET) and potential Evapotranspiration (PET), and spatially analyzed. Results revealed that there are regional disparities in frequency and duration of FDs, with a mean frequency of 6.4 and duration of 31 days. When classified into Case 1 (normal condition), Case 2 (AET-driven), and Case 3 (PET-driven), we found that Case 2 FDs emerged approximately 1.5 times more frequently than those driven by PET (Case 3) across the Korean peninsula. Case 2 FDs were found to be induced under water-limited conditions, and led both AET and PET to be decreased. Conversely, Case 3 FDs occurred under energy-limited conditions, with increase in both. Case 2 FDs predominantly affected the northwestern and central-southern agricultural regions, while Case 3 occurred in the eastern region, characterized by forested land cover. These findings offers insights into our understanding of FDs over the Korean peninsula, considering climate factors, land cover, and water availability.

An Estimation of NPS Pollutant Loads using the Correlation between Storm Water Runoff and Pollutant Discharge in a Small Urban Drainage Basin (도시소유역에서의 유출과 비점원오염물 배출 간의 상관관계 수립에 의한 NPS 오염물 배출량의 산정)

  • 신현석;윤용남
    • Water for future
    • /
    • v.26 no.4
    • /
    • pp.85-95
    • /
    • 1993
  • Three purposes of this study are as follows: The first was the development of the extention method for the limited data observed in an urban drainage basin. The second was the analysis of the correlation between storm water runoff and NPS(non-point source) pollutant discharge, The last was the calculation of the monthly and annual specific NPS loads using the established correlation. the selected model was the SWMM monthly and annual specific NPs loads using the established correlation. The selected model was the SWMM (Storm Water Management model) developed by the US EPA(environmental Protection Agency). As a result of this study, the best correlation between storm wate runoff and NPS pollutants discharge was produced by the non-linear correlation between runoff rate(mm/hr)and specific loads rate(g/ha/sec)for all pollutants studied ; SS, COD, BOD, and TN. The best correlation through the analysis based on evently total mass was made by the linear correlation between the specific accumulated runoff(mm) and the specific accumulated loads(kg/ha) for CASE 1., and by the non-linear correlation for CASE 2. The NPS annual specific loads for the urban basin studied were 4933 kg/ha/year for SS, 775kg/ha/year for BOD, 3094kg/ha /year for COD,257kg/ha/year for TN, respectively. And the proportion of the NPS annual specific loads to the total annual specific loads were 42 % for SS, 13 % for BOD, 29% for COD, and 21 % for TN.

  • PDF

A Study on the Cooling Effect of a Water Fire Extinguishing Agent Containing NaBr (NaBr을 첨가한 물소화제의 냉각효과에 관한 연구)

  • 방창훈;김종석
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.6-12
    • /
    • 2001
  • The objective of the present work is to examine the cooling effect of a water fire extinguishing agent containing NaBr(30%, w/w). The carbon steel and teflon were used as a hot solid. The temperature on the hot solid surface ranged from $70^{\circ}c$ to $116^{\circ}c$ and water droplet size was 2.6 mm in the experiments. It is suggested that regardless of the hot solid material, the indepth temperature of the case of NaBr solution is lower than that of pure water and the variation of indepth temperature of teflon is higher than that of carbon steel. Regardless of the hot solid material, the time averaged heat flux of the case of pure water is higher than that of NaBr solution. the apparent evaporation time of the case of pure water is shorter than that of NaBr solution.

  • PDF

The Studies on the Production of Ginseng Extract by Amylase (Amylase를 이용한 인삼엑기스의 제조)

  • 임무현;조규성;김해중;주현규
    • Journal of Ginseng Research
    • /
    • v.3 no.2
    • /
    • pp.134-143
    • /
    • 1979
  • It order to extract the soluble organic substances of Korean ginseng effectively, the ginseng extract have been made by using amylase. The investigation on the optimum condition of enzyme reaction was carried out, and the amounts of gained extract and its saponin pattern were compared among the ethanol extract, water extract and enzyme extract. The results obtained are summerized as follows. 1. The gaining ratio or ginseng extract was the highest value when the raw ginseng and dried ginseng were extracted in the concentration of 7.5% and 5% with 0.3%∼0.6% enzyme for 25 hour. 2. The amounts of ethanol extract, water extract and enzyme extract were 9.14%, 17.23% and 23.73% in case of raw ginseng and 64.09%, 72.52% and 74.36% in case of dried ginseng, respectively. The amount of enzyme extract was increased as much as 6∼14% in case of raw ginseng, and 2∼10% in case of dried ginseng compared with that of ethanol and water extract. 3. The absolute content of saponin was nearly constant in spite of the different extraction method and all of the ginseng saponin pattern of thin-layer chromatograms were almost same.

  • PDF

Study in the integrated watershade management for conservation of water resources (II) - Water quality modeling and simulation of Oship stream - (수자원 보전을 위한 유역통합관리 방안에 관한 연구(II) - 오십천 수계의 수질모델링 및 수질 예측 -)

  • 허인량;정의호;권재혁
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.61-69
    • /
    • 2002
  • Oship stream is located nearby south eastern coasts. This study was performed to find out waters quality modeling and then to predict water quality of Oship stream. Based on survey data, BOD, T-N, T-P calibration and verification result were in good agreement with measured value within mean coefficient variance(MSE) value, which were 13.9%, 9.0%, 26.5% and 19.5%, 12.0%, 16.5%, respectively. Sectional water quality predictions of the main stream of Oship stream are executed on the basis of the following cases 1) with sewage treatment of Dogye-eup 2) reduction of mine wastewater treatment of 80% in th basin. As a result, BOD, T-P improvement rates at down stream of Oship stream, case 1) were appeared 12.2%, 22.2%, case 2) maximum sulfate ion and conductivity reduction removal rate of Oship stream were 58%, 68%. The main pollution sources of Oship-stream were almost domestic wastewater and mine wastewater discharged from Dogye-eup which located in uppers stream. The large effects will appear after the construction of Dogye sewage water treatment plant which remove the organic matter and nutrients in these sewage water. The waste water from mine can not easily to treat for characteristics of effluence and economic problems. However, to achieve the goal of water quality in Oship-stream water system, treatments of those are necessary.