• Title/Summary/Keyword: Cascade system

Search Result 444, Processing Time 0.03 seconds

An experimental study on the flow characteristics of a supersonic turbine cascade

  • Cho, Jong-jae;Jeong, Soo-in;Kim, Kui-soon;Lee, Eun-seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.807-812
    • /
    • 2004
  • In this paper, a small supersonic wind tunnel was designed and built to study the flow characteristics of a supersonic impulse turbine cascade by experiment. The flow was visualized by means of a single pass Schlieren system. The supersonic cascade with 3-dimensional supersonic nozzle was tested over a wide range of pressure ratio. Highly complicated flow patterns including shocks, nozzle-cascade interaction and shock boundary layer interactions were observed.

  • PDF

Design of Optimized Fuzzy Cascade Controller Based on HFCGA for Ball & Beam System (Ball & Beam 시스템에 대한 계층적 공정 경쟁 유전자 알고리즘을 이용한 최적 퍼지 캐스케이드 제어기 설계)

  • Jang, Han-Jong;Choi, Jeoung-Nae;Oh, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.308-309
    • /
    • 2007
  • 본 논문에서는 계층적 공정 경쟁 기반 병렬 유전자 알고리즘 (Hierarchical Fair Competition Genetic Algorithm: HFCGA)을 이용하여 Ball & Beam 시스템에 최적의 Fuzzy Cascade 제어기를 설계하고자 한다. Ball & Beam 시스템은 비선형적이며 Beam의 마찰계수와 Ball의 중력 가속도를 고려하여 Ball의 위치를 조정하는 시스템이다. 이러한 Ball & Beam 시스템에 대해 Fuzzy Cascade 제어기를 설계하고, 조기 수렴에 문제가 있는 기존의 유전자 알고리즘을 개선한 HFCGA를 이용하여 제어기의 파라미터를 최적화 한다. 마지막으로 실제 플랜트에 적용하여 설계된 제어기의 성능을 평가하고, PD Cascade 제어기와 Fuzzy Cascade 제어기의 성능을 비교한다.

  • PDF

Performance comparison of cascade refrigerator and two-stage compression refrigerator (캐스케이드 냉동시스템과 2단 압축 1단 팽창식 냉동 시스템의 성능 비교)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.625-631
    • /
    • 2014
  • In order to obtain a low evaporation temperature ranging from $-30^{\circ}C{\sim}-50^{\circ}C$, a cascade refrigeration system and two-stage compression one-stage expansion refrigeration system is required. However, the research results of performance comparison of these refrigeration system are very scarce. This paper were compared the performance characteristics of R744-R404A cascade refrigeration system and R404A two-stage compression refrigeration system. The COP of R404A two-stage compression refrigeration system is about 36~57% greater than that of R744-R404A cascade refrigeration system in the range of evaporation temperature of $-30^{\circ}C{\sim}-50^{\circ}C$. But R404A two-stage compression refrigeration system is unstable because COP is significantly changed when evaporating temperature and compressor efficiency decreased. In particular, when compressor efficiency decreased, COP is significantly decreased. In this case, not efficient for long-term use. Whereas R744-R404A cascade refrigeration system using natural refrigerants. Therefore, it is environmentally friendly. And this system is high-efficiency refrigeration system. The reason it can be configured by selecting the suitable refrigerant at high-temperature side and low-temperature side. From the above results, select the appropriate low temperature refrigeration system by considering the environmental and performance aspects.

Improvement on Sensorless Vector Control Performance of PMSM with Sliding Mode Observer

  • Wibowo, Wahyu Kunto;Jeong, Seok-Kwon;Jung, Young-Mi
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.129-136
    • /
    • 2014
  • This paper proposes improvement on sensorless vector control performance of a permanent magnet synchronous motor (PMSM) with sliding mode observer. An adaptive observer gain and second order cascade low-pass filter (LPF) were used to improve the estimation accuracy of the rotor position and speed. The adaptive observer gain was applied to suppress the chattering intensity and obtained by using the Lyapunov's stability criterion. The second order cascade LPF was designed for the system to escalate the filtering performance of the back-emf estimation. Furthermore, genetic algorithm was used to optimize the system PI controller's performance. Simulation results showed the effectiveness of the suggested improvement strategy. Moreover, the strategy was useful for the sensorless vector control of PMSM to operate on the low-speed area.

A Study on the Cold Energy for Liquefied Nitrogen Gas and Cascade Refrigeration System (액화질소 초저온과 이원냉동 초저온 냉열의 비교 실험적 연구)

  • Kim, C.S.;Jang, H.S.;Jeong, H.M;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.56-62
    • /
    • 2007
  • This paper represents the cold energy for liquefied nitrogen gas and cascade refrigerator. In this study, the vaporizer of liquefied nitrogen gas has the fin coil tube type with the dimension of inside diameter of 10mm and outside diameter of 12mm. Also, the total length of vaporizer is 20,000mm. The main experimental parameters are the mean velocity in duct and the supplied flow-rates of liquefied nitrogen gas. For the cascade refrigeration system, the refrigerants are ethane(R 170) in the high pressure stage and R 22 in the low pressure stage.

  • PDF

Study on the Performance of a Cascade Heat Pump with Two-stage Water Heating Process (2단 승온 캐스케이드 히트펌프의 성능 특성에 관한 연구)

  • Jang, Hanbyeoul;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.27-32
    • /
    • 2016
  • It is estimated that only heating and cooling take about one third of the total energy consumption worldwide. However, the conventional heating and cooling systems have low efficiencies. Also, boilers and electric heaters that are mostly used to generate both domestic and industrial hot water are inefficient and high energy consumers. For this reason, cascade heat pumps which are known to be very energy efficient and have less environmental impact are being promoted to replace conventional heating, cooling and hot water systems. In this study, a newly designed cascade heat pump by two-stage water heating method has been experimentally investigated. By adopting the auxiliary heat exchanger, the performance of the system was increased. The performance enhancement rate of the system could be maximized by adjusting the low stage compressor speed rather than the high stage compressor speed. The performance of the system with the auxiliary heat exchanger was enhanced by 16.5%.

Design of Low Cost Real-Time Audience Adaptive Digital Signage using Haar Cascade Facial Measures

  • Lee, Dongwoo;Kim, Daehyun;Lee, Junghoon;Lee, Seungyoun;Hwang, Hyunsuk;Mariappan, Vinayagam;Lee, Minwoo;Cha, Jaesang
    • International Journal of Advanced Culture Technology
    • /
    • v.5 no.1
    • /
    • pp.51-57
    • /
    • 2017
  • Digital signage is becoming part of daily life across a wide range of visual advertisements segments market used in stations, hotels, retail stores, hotels, etc. The current digital signage system used in market is generally works on limited user interactivity with static contents. In this paper, a new approach is proposed using computer vision based dynamic audience adaptive cost-effective digital signage system. The proposed design uses the Camera attached Raspberry Pi Open source platform to employ the real-time audience interaction using computer vision algorithms to extract facial features of the audience. The real-time facial features are extracted using Haar Cascade algorithm which are used for audience gender specific rendering of dynamic digital signage content. The audience facial characterization using Haar Cascade is evaluated on the FERET database with 95% accuracy for gender classification. The proposed system, developed and evaluated with male and female audiences in real-life environments camera embedded raspberry pi with good level of accuracy.

Analysis of Back-to-back Refueling for Heavy Duty Hydrogen Fuel Cell Vehicles Using Hydrogen Refueling Stations Based on Cascade System (캐스케이드 시스템 기반 수소 충전소를 이용한 대형 수소 연료 전지 차량 연속 충전 분석)

  • GYU SEOK SHIM;BYUNG HEUNG PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.3
    • /
    • pp.300-309
    • /
    • 2024
  • Hydrogen utilization in the transportation sector, which relies on fossil fuels, can significantly reduce greenhouse gas by using to hydrogen fuel cell vehicles, and its adoption depends performance of hydrogen refueling station. The present study developed a model to simulate the back-to-back filling process of heavy duty hydrogen fuel cell vehicles at hydrogen refueling stations using a cascade method. And its quantitatively evaluated hydrogen refueling station performance by simulating various mass flow rates and storage tank capacity combinations, analyzing vehicle state of charge (SOC) of vehicles. In the cascade refueling system, the capacity of the high-pressure storage tank was found to have the greatest impact on the reduction of filling time and improvement of efficiency.

Mass flow rate ratio analysis for optimal refrigerant charge of a R744 and R404A cascade refrigeration system (R744-R404A 캐스케이드 냉동시스템의 최적 냉매 충전을 위한 질량유량비 분석)

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Jo, Hwan;Jeon, Min-Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.575-581
    • /
    • 2013
  • In this paper, the influences of several factors, such as subcooling, superheating degree, internal heat exchanger efficiency, and etc. to the optimal amount of refrigerant charge are investigated for the case of R744-R404A cascade refrigeration system. Refrigerants used in the cascade refrigeration system are R404A in high temperature cycle and R744 in the low temperature cycle. The main results are summarized as follows : The mass flow rate ratio decreases with increasing subcooling, superheating degree and internal heat exchanger efficiency in the high temperature cycle, and evaporating temperature and compression efficiency in the low temperature cycle. And the mass flow rate ratio decreases with decreasing temperature difference of cascade heat exchanger and evaporating, condensing temperature in the high temperature cycle, and subcooling, superheating degree and internal heat exchanger efficiency in the low temperature cycle.

Fuzzy-based PID Controller for Cascade Process Control

  • Tummaruckwattana, S.;Pannil, P.;Chaikla, A.;Tirasesth, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.268-271
    • /
    • 2004
  • This paper describes the development of a fuzzy logic control based on PID controller to improve the performances of the control system using conventional PID controller for the cascade process control systems. The structure of the proposed control system consists of two fuzzy-based PID controllers. One is used to eliminate the input disturbances of the inner loop and the other is used to regulate output response of the outer loop. The fuzzy PID design is derived from the linear-time continuous function of the conventional PID controller. The performance of the proposed controller is verified by MATLAB/SIMULINK simulation. Results of simulation studies demonstrates the outstanding of the control system using fuzzy-based PID controller in terms of reduced overshoot and fast response compared with the conventional PID controller.

  • PDF