• Title/Summary/Keyword: Carotid artery ultrasonography

Search Result 54, Processing Time 0.021 seconds

Effects of Electrotherapy on Blood Velocity of Cranial Artery in Tension-Type Headache subjects (전기치료가 긴장형 두통환자의 뇌 혈류 속도에 미치는 영향)

  • Park Rae-Joon;Kim Jin-Sang;Lee In-Hak;Park Jang-hwan;Han Dong-Uck
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.3
    • /
    • pp.349-359
    • /
    • 2000
  • The aim of study was to evaluated the possible role of cranial artery velocity in headache pathogenesis. The present study was studied of five headache(F=5. Mean $age=29.80\pm6.76yrs$) were compared to 4 controls(F=4, Mean $age=29.00\pm5.48yrs$). Transcranial doppler ultrasonography(TCD) is a new non-invasive and easily applicable method to evaluate flow velocities of the intracranial and extracranial cerebral arteries. TCD was performed with standard method to measure the mean Flow Velocity(MFV) of the middle and posterior cerebral arteries, the internal carotid artery, the vertebral and the basilar artery. We reviewed the whole TCD results performed at Taejon Veterans Hospital from October. 11. 2000 to November. 10. 2000. Mean flow velocities in headaches and controls at their 6 decades are $28.00\pm3.61cm/sec$ and $41.25pm1.71cm/sec$ in lent PCA (P<0.01), $50,000\pm23.07cm/sec$ and $82.75\pm15.59cm/sec$ in right MCA(P<0.05), $26.20\pm4.82cm/sec$ and $45.50\pm4.51cm/sec$ in fight PCA(P<0.01). $26.60\pm4.56cm/sec$ and $38.25\pm4.92cm/sec$ in right VAC(P<0.01). After treatment for 2 weeks, mean of velocity on pre treatment and post treatment and post treatment are $28.00\pm3.61cm/sec$ and $38.20\pm5.81cm/sec$ in left PCA (P<0.05), $26.20\pm4.827cm/sec$ and $39.20\pm5.54cm/sec$ in right PCA(P<0.05), $40.60\pm9.18cm/sec$ in right VA(P<0.01). It is concluded that Electrical Therapy for two weeks was effected to promote Mean Flow of Velocity in cranial artery. Mean of velocity in cranial artery with headaches observed in this study was lower than controls, but MFV was promote after treatment for 2 weeks.

  • PDF

Sonographic Findings of Second Branchial Cleft Cysts; Variable Appearances and Helpful Diagnostic Findings (제2새열 낭종의 초음파 소견;다양한 소견들과 진단에 도움이 될 만한 소견들)

  • Kim, Heung-Cheol;Lee, Jun-Ho;NamKung, Sook;Hong, Myung-Sun;Hwang, Im-Kyung
    • Korean Journal of Head & Neck Oncology
    • /
    • v.24 no.1
    • /
    • pp.53-56
    • /
    • 2008
  • Objectives:The purpose of this study was to evaluate the variable sonographic features in addition to classic findings and to find the helpful characteristic findings for diagnosis of branchial cleft cysts. Subjects and Methods:We retrospectively analyzed the sonographic finding of 16 histopathologically proven branchial cleft cysts. Assessment involved the following variables : location related to carotid artery, size, cyst wall, border, margin, shape, internal echotexture, post echoic enhancement, orientation of longitudinal axis relative to the long axis of the neck, and tapering edge. Results:Most branchial cleft cysts were seen as well defined(15/16), oval shape(13/16), smooth inner (12/16) and outer margin(13/16), and post echoic enhancement(16/16). Their diameter varied from 1 to 6cm (mean 3.3cm). The branchial cleft cysts showed variable internal echopatterns;hyperechogenicity or pseudosolid appearance(1/16), heterogeneous echogenicity(4/16) in addition to classic form of anechoic(5/16) or hypoechoic internal echogenicity(6/16). Longitudinal axis of most branchial cleft cysts were arranged in the direction of the long axis of the neck(13/16) and some branchial cleft cysts had tapering edge(6/16). Conclusion:If both atypical sonographic findings and location are showed, longitudinal arrangement of long axis and tapering edge of branchial cleft cysts are helpful findings for differential diagnosis.

A Study on Wearable Emotion Monitoring System Under Natural Conditions Applying Noncontact Type Inductive Sensor (자연 상태에서의 인간감성 평가를 위한 비접촉식 인덕티브 센싱 기반의 착용형 센서 연구)

  • Hyun-Seung Cho;Jin-Hee Yang;Sang-Yeob Lee;Jeong-Whan Lee;Joo-Hyeon Lee;Hoon Kim
    • Science of Emotion and Sensibility
    • /
    • v.26 no.3
    • /
    • pp.149-160
    • /
    • 2023
  • This study develops a time-varying system-based noncontact fabric sensor that can measure cerebral blood-flow signals to explore the possibility of brain blood-signal detection and emotional evaluation. The textile sensor was implemented as a coil-type sensor by combining 30 silver threads of 40 deniers and then embroidering it with the computer machine. For the cerebral blood-flow measurement experiment, subjects were asked to attach a coil-type sensor to the carotid artery area, wear an electrocardiogram (ECG) electrode and a respiration (RSP) measurement belt. In addition, Doppler ultrasonography was performed using an ultrasonic diagnostic device to measure the speed of blood flow. The subject was asked to wear Meta Quest 2, measure the blood-flow change signal when viewing the manipulated image visual stimulus, and fill out an emotional-evaluation questionnaire. The measurement results show that the textile-sensor-measured signal also changes with a change in the blood-flow rate signal measured using the Doppler ultrasonography. These findings verify that the cerebral blood-flow signal can be measured using a coil-type textile sensor. In addition, the HRV extracted from ECG and PLL signals (textile sensor signals) are calculated and compared for emotional evaluation. The comparison results show that for the change in the ratio because of the activation of the sympathetic and parasympathetic nervous systems due to visual stimulation, the values calculated using the textile sensor and ECG signals tend to be similar. In conclusion, a the proposed time-varying system-based coil-type textile sensor can be used to study changes in the cerebral blood flow and monitor emotions.

Central Nervous System Complications of Coronary Artery Bypass Grafting - Comparison Between Off-Pump CABG and Conventional CABG (관상동맥 우회술 후의 중추신경계 합병증 - 심폐바이패스를 사용하지 않은 관상동맥 우회술과 기존의 관상동맥 우회술의 비교)

  • Chang, Ji-Min;Lee, Jeong-Sang;Kim, Ki-Bong;Ahn, Hyuk;Yoon, Byung-Woo;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.33 no.12
    • /
    • pp.941-947
    • /
    • 2000
  • Background: Central nervous system complication after coronary artery bypass grafting(CABG) is one of the major prognostic determinants and the use of the cardiopulmonary bypass(CPB) may increase the incidence of this devastating complication. In this study, the outcomes after off-pump CABG were studied and compared with those following the conventional CABG using CPB. Material and Method: Among the consecutive isolated CABG's performed in SNUH during Feb. 1995 and Jun. 1999, 338 coronary artery bypass grafting were divided into two groups. 223 patients underwent CABG using the CPB(Group I), and 115 patients underwent CABG without CPB(OPCAB)(Group II). All patients enrolled in this study received extensive preoperative examinations including thorough neurologic examination before and after surgery, transcranial doppler study, carotid duplex ultrasonography, and magnetic resonance angiography if necessary. Central nervous system(CNS) complications were defined as stroke, seizure, metabolic or hypoxic encephalopathy and transient delirium after surgery. Result: There were 61 cases(27.3%) who developed postoperative CNS complication in Group I, whereas 8 cases(7.0%) of CNS complications developed postoperatively in group II(p<0.05). Statistically significant predictors of postoperative CNS complications in group I were age and the use of cardiac assist devices perioperatively. Conclusion: This study suggested that omitting the use of CPB in CABG resulted in significant decrease of the postoperative CNS complications. OPCAB should be more widely applied especially to the elderly who have preexisting cerebrovascular disease.

  • PDF