• Title/Summary/Keyword: CareDose 4D

Search Result 35, Processing Time 0.024 seconds

Measurement of Radiation Dose of HR CT and Low Dose CT by using Anthropomorphic Chest Phantom and Glass Dosimetry (인체등가형 흉부팬텀과 유리선량계를 이용한 고해상력 및 저선량 CT의 선량측정)

  • Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.933-939
    • /
    • 2019
  • The purpose of this study is to provide basic clinical data by evaluating images, measuring absorbed dose and effective dose by using high resolution CT and low dose CT by using anthropomorphic chest phantom and glass dosimeter. Tissue dose was measured by inserting a glass dosimeter into the anthropomorphic chest phantom. A 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany) and CARE Dose 4D were used, and the parameters of the high resolution CT were 120 kVp, Eff. Scan parameters of mAs 104, scan time 7.93 s, slice 1.0 mm (Acq. 64 × 0.6 mm), convolution kernel (B60f sharp) were used, and low dose CT was 120 kVp, Eff. mAs 15, scan time 7.41 s, slice 3.0 mm (Acq. 64 × 0.6 mm), scan of convolution kernel B50f medium sharp. CTDIvol was measured at 8.01 mGy for high resolution CT and 1.18 mGy for low dose CT. Low dose CT scans showed 85.49% less absorbed dose than high resolution CT scans.

The Effects of Polydatin Isolated from Polygonum cuspidatum on Melanogenesis and Wrinkle Formation (호장으로부터 분리한 Polydatin의 미백 및 주름억제 효능에 대한 연구)

  • Jin, Mu-Hyun;Jeong, Eui-Taek;Kim, Mi-Sun;Song, Hye-Jin;Kwak, Taek-jong;Park, Sun-Gyoo;Lee, Sang-Min
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.37 no.4
    • /
    • pp.327-335
    • /
    • 2011
  • 5,4'-dihydroxystilbene-3-O-${\beta}$-D-glucopyranoside (Polydatin) is one of the stilbenes found in Polygonum cuspidatum (P. cuspidatum), however, the effects of polydatin on skin biology remain to be elucidated. In this study, we obtained polydatin from P. cuspidatum and investigated the effects of polydatin in skin-derived melanocytes and fibroblasts. In melanocytes, polydatin inhibited not only the tyrosinase activity and melanin production but the expression of melanogenic factors, tyrosinase and microphthalmia-associated transcription factor (MITF). In addition, the level of type I procollagen in fibroblasts was analyzed, and polydatin significantly induced the production of type I procollagen in a dose-dependent manner. Finally we conformed that topical treatment of polydatin improved wrinkle and induced whitening of human skin in vivo. These data provide evidence that polydatin can be a potent candidate for the improvement of both skin wrinkle and whitening from the point of industry view.

Plan Dose Evaluation of Three Dimensional Conformal Radiotherapy Planning (3D-CRT) of Nasopharyngeal Carcinoma (NPC): Experience of a Tertiary Care University Hospital in Pakistan

  • Abbasi, Ahmed Nadeem;Hafiz, Asim;Ali, Nasir;Khan, Khurshid Ahmed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5989-5993
    • /
    • 2013
  • Background: Radiation therapy is the mainstay of treatment for nasopharyngeal carcinoma. Importance of tumor coverage and challenges posed by its unique and critical location are well evident. Therefore we aimed to evaluate our radiation treatment plan through dose volume histograms (DVHs) to find planning target volume (PTV) dose coverage and factors affecting it. Materials and Methods: This retrospective study covered 45 histologically proven nasopharyngeal cancer patients who were treated with definitive 3D-CRT and chemotherapy between Feb 2006 to March 2013 at the Department of Oncology, Section Radiation Oncology, Aga Khan University Hospital, Karachi, Pakistan. DVH was evaluated to find numbers of shrinking field (phases), PTV volume in different phases and its coverage by the 95% isodose lines, along with influencing factors. Results: There were 36 males (80%) and 9 females (20%) in the age range of 12-84 years. Stage IVA (46.7%) was the most common stage followed by stage III (31.1). Eighty six point six-percent received induction, 95.5% received concurrent and 22.2% received adjuvant chemotherapy. The prescribed median radiation dose was 70Gy to primary, 60Gy to clinically positive neck nodes and 50Gy to clinically negative neck regions. Mean dose to spinal cord was 44.2Gy and to optic chiasma was 52Gy. Thirty seven point eight-percent patients completed their treatment in three phases while 62.2% required four to five phases. Mean volume for PTV3 was $247.8cm^3$ (50-644.3), PTV4 $173.8cm^3$ (26.5-345.1) and PTV5 $119.6cm^3$ (18.9-246.1) and PTV volume coverage by 95% isodose lines were 74.4%, 85.7% and 100% respectively. Advanced T stage, intracranial extension and tumor volume > $200cm^3$ were found to be important factors associated with decreased PTV coverage by 95% isodose line. Conclusions: 3D CRT results in adequate PTV dose coverage by 95% isodose line. However advanced T stage, intracranial extension and large target volume require more advanced techniques like IMRT for appropriate PTV coverage.

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Dose Planning Study of Target Volume Coverage with Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma: Penang General Hospital Experience

  • Vincent Phua, Chee Ee;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng;Ung, Ngie Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2243-2248
    • /
    • 2013
  • Background: To compare the dosimetric coverage of target volumes and organs at risk in the radical treatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Materials and Methods: Data from 10 consecutive patients treated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively for analysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans using a total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5 measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The means of each comparison target volume coverage measures and organs at risk measures were obtained and tested for statistical significance using the paired Student t-test. Results: All 5 measures for target volume coverage showed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absolute improvement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and 16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organs at risk showed statistically significant difference in their means which were clinically meaningful between the IMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid (less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less 44.3%). Conclusions: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coverage while delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as a standard of care for radical treatment of NPC.

Evaluation of Scintillation Camera Applications of 3D Printing Phantom (3D 프린팅 팬텀의 섬광카메라 적용 평가)

  • Park, Hoon-Hee;Lee, Ju-young;Kim, Ji-Hyeon
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.343-350
    • /
    • 2021
  • 3D printing technology is an additive manufacturing technology produced through 3D scanning or modeling method. This technology can be produced in a short time without mold, which has recently been applied in earnest in various fields. In the medical field, 3D printing technology is used in various fields of radiology and radiation therapy, but related research is insufficient in the field of nuclear medicine. In this study, we compare the characteristics of traditional nuclear medicine phantom with 3D printing technology and evaluate its applicability in clinical trials. We manufactured the same size phantom of poly methyl meta acrylate(PMMA) and acrylonitrile butadiene styrene(ABS) based on the aluminum step wedge. We used BrightView XCT(Philips Health Care, Cleveland, USA) SPECT/CT. We acquired 60 min list mode for Aluminum, PMMA and ABS phantoms using Rectangular Flood Phantom (Biodex, New York, USA) 99mTcO4 3 mCi(111 MBq), 6 mCi (222MBq) and 57Co Flood phantom(adq, New Hampshire, USA). For the analysis of acquired images, the region of interest(ROI) were drawn and evaluated step by step for each phantom. Depending on the type of radioisotope and radiation dose, the counts of the ABS phantom was similar to that of the PMMA phantom. And as the step thickness increased, the counts decreased linearly. When comparing the linear attenuation coefficient of Aluminum, PMMA and ABS phantom, the linear attenuation coefficient of the aluminium phantom was higher than that of the others, and the PMMA and ABS phantom had similar the linear attenuation coefficient. Based on ABS phantom manufactured by 3D printing technology, as the thickness of the PMMA phantom increased, the counts and linear attenuation coefficient decreased linearly. It has been confirmed that ABS phantom is applicable in the clinical field of nuclear medicine. If the calibration factor is applied through further research, it is believed that practical application will be possible.

The Efficacy of Interferon(IFN)-${\gamma}$ in Idiopathic Pulmonary Fibrosis (특발성 폐섬유화증에서 Interferon-${\gamma}$의 효과)

  • Park, Joo Hun;Oh, Yeon Mok;Shim, Tae Sun;Lim, Chae-Man;Koh, Younsuck;Lee, Sang-Do;Kim, Woo Sung;Kim, Won Dong;Kim, Dong Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.6
    • /
    • pp.611-618
    • /
    • 2004
  • Background : Idiopathic pulmonary fibrosis(IPF), a subtype of IIP(idiopathic interstitial pneumonia), is a fatal disease with a 3-5 year median survival. Many attempts at treating this condition have failed to demonstrate a survival benefit in IPF. Recently Ziesche et $al^{12}$ reported the efficacy of IFN-${\gamma}$ for treating IPF but there is still some controversy. The aim of this study was to determine the efficacy of IFN-${\gamma}$ in patients with advanced IPF who had not been responsive to steroid and cytotoxic agents. Method : Nine patients with advanced IPF(age: $55.4{\pm}15.3$ years, Male: Female=8:1) were enrolled. One year treatment regime with 2 million IU of IFN-${\gamma}$ administered subcutaneously three times a week, and low dose prednisolone(10-30 mg/d) was also used. In the case of a definite aggravation and serious side effects, the IFN-${\gamma}$ was discontinued. During the IFN-${\gamma}$ trial, a pulmonary function test and chest radiography were checked every three month throughout the study. Result : 1) Among 9 patients, only 4 patients were able to complete the 12 month treatment with IFN-${\gamma}$, and 5 patients died during the treatment period. 2) No improvement either in the respiratory symptoms or pulmonary functions were observed any of the patients, even in those who completed the 12 months trial of IFN-${\gamma}$, 3) At the time of IFN-${\gamma}$ trial, the survivors who finished the IFN-${\gamma}$ treatment for 12 months had a higher oxygen level($81.3{\pm}2.8$ vs. $67.4{\pm}8.4$, P=0.024) and a better pulmonary function(FVC: $61.3{\pm}5.1$ % predicted vs. $45.7{\pm}12.3%$, P=0.048, and $D_Lco$: $45.0{\pm}5.0%$ predicted vs. $30.8{\pm}11.2%$, P=0.048) than the non-survivors. Conclusion : Our data suggested that IFN-${\gamma}$ therapy was not effective in the patients with advanced IPF refractory compared with other therapeutic agents. Furthermore, these results suggest that severe impairment of the pulmonary function and hypoxemia during the IFN-${\gamma}$ therapy requires special attention.

Moderate hypofractionated image-guided thoracic radiotherapy for locally advanced node-positive non-small cell lung cancer patients with very limited lung function: a case report

  • Manapov, Farkhad;Roengvoraphoj, Olarn;Li, Minglun;Eze, Chukwuka
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.180-184
    • /
    • 2017
  • Patients with locally advanced lung cancer and very limited pulmonary function (forced expiratory volume in 1 second $[FEV1]{\leq}1L$) have dismal prognosis and undergo palliative treatment or best supportive care. We describe two cases of locally advanced node-positive non-small cell lung cancer (NSCLC) patients with very limited lung function treated with induction chemotherapy and moderate hypofractionated image-guided radiotherapy (Hypo-IGRT). Hypo-IGRT was delivered to a total dose of 45 Gy to the primary tumor and involved lymph nodes. Planning was based on positron emission tomography-computed tomography (PET/CT) and four-dimensional computed tomography (4D-CT). Internal target volume (ITV) was defined as the overlap of gross tumor volume delineated on 10 phases of 4D-CT. ITV to planning target volume margin was 5 mm in all directions. Both patients showed good clinical and radiological response. No relevant toxicity was documented. Hypo-IGRT is feasible treatment option in locally advanced node-positive NSCLC patients with very limited lung function ($FEV1{\leq}1L$).

Bleomycin, Etoposide and Cisplatinum (BEP) Chemotherapy for Metastatic Germ Cell Tumours: Treatment Outcomes at UKM Medical Centre, Malaysia

  • Azrif, Muhammad;Leong, Yu Kong;Aslan, Nik Muhammad;Fong, Kua Voon;Ismail, Fuad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2467-2471
    • /
    • 2012
  • Introduction: Although bleomycin/etoposide/cisplatinum (BEP) chemotherapy is established as the standard treatment for germ cell tumours, it requires significant experience in administration and toxicity management to maintain optimal dose intensity. A retrospective review of 30 patients was conducted at UKMMC to study treatment outcomes. Methods & Materials: Patients with GCTs and treated with at least two cycles of BEP chemotherapy between January 2003 and Oct 2009 were eligible for this study. Patients received 4-6 cycles of bleomycin 30,000IU IV D1, D8 & D15 and either etoposide $100mg/m^2$ IV D1-D5 and cisplatin $20mg/m^2$ IV D1-D5 (5 day BEP regimen) or etoposide $165mg/m^2$ D1-D3 and cisplatin $50mg/m^2$ D1-3 (3 day BEP regimen) every three weeks per cycle. All patients received prophylactic granulocyte colony-stimulating factor (GCSF) from days 6 to 10 of each cycle. The overall response rates, 2 year progression-free survival and overall survival of the whole cohort were assessed. Results: Thirty patients fulfilled the inclusion criteria. Non-seminomatous GCTs comprised 93.3% of cases and gonadal and mediastinal primary sites were the most common. Sixty percent were classified as IGCCCG poor risk disease. Median follow-up was 26.6 months. The overall response rate (CR+PR) was 70%. The two year PFS and OS were 70% and 66%. There was a significant difference in terms of the overall response rate (85% vs 40%, p = 0.03) and in PFS (94.7% vs 50%, p = 0.003) between gonadal and extragonadal primary sites. Conclusion: It is possible to achieve outcomes similar to those in international clinical trials with close monitoring and good supportive care of patients undergoing BEP chemotherapy. There is a strong argument for patients with IGCCCG poor prognosis disease to be treated in specialist tertiary centres to optimize treatment outcomes.