• Title/Summary/Keyword: Cardiovascular stability

Search Result 65, Processing Time 0.027 seconds

Alteration of the Metabolome Profile in Endothelial Cells by Overexpression of miR-143/145

  • Wang, Wenshuo;Yang, Ye;Wang, Yiqing;Pang, Liewen;Huang, Jiechun;Tao, Hongyue;Sun, Xiaotian;Liu, Chen
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.3
    • /
    • pp.572-578
    • /
    • 2016
  • Communication between endothelial cells (ECs) and smooth muscle cells (SMCs) via miR-143/145 clusters is vital to vascular stability. Previous research demonstrates that miR-143/145 released from ECs can regulate SMC proliferation and migration. In addition, a recent study has found that SMCs also have the capability of manipulating EC function via miR-143/145. In the present study, we artificially increased the expression of miR-143/145 in ECs, to mimic a similar change caused by miR-143/145 released by SMCs, and applied untargeted metabolomics analysis, aimed at investigating the consequential effect of miR-143/145 overexpression. Our results showed that miR-143/145 overexpression alters the levels of metabolites involved in energy production, DNA methylation, and oxidative stress. These changed metabolites indicate that metabolic pathways, such as the SAM cycle and TCA cycle, exhibit significant differences from the norm with miR-143/145 overexpression.

Study on Genipin: A New Alternative Natural Crosslinking Agent for Fixing Heterograft Tissue

  • Yoo, Jae-Suk;Kim, Yong-Jin;Kim, Soo-Hwan;Choi, Seung-Hwa
    • Journal of Chest Surgery
    • /
    • v.44 no.3
    • /
    • pp.197-207
    • /
    • 2011
  • Background: In cardiac surgery, especially in the reconstruction of vascular structures and intracardiac defects, glutaraldehyde has usually been used as the reagent for fixing porcine or bovine pericardial tissues. But the well-known problem of calcification or cytotoxicity of glutaraldehyde motivates the search for a replacement. The aim of this study is to investigate the physical, mechanical, and biochemical characteristics of bovine pericardial tissues fixed with genipin, which is known to be a less toxic and more natural fixing reagent. Materials and Methods: Bovine pericardial tissues were fixed with different concentrations and conditions of glutaraldehyde and genipin. To determine the physical, mechanical, and biochemical differences among different concentrations and conditions, we divided the tissue into 18 groups by concentration, the addition of organic solvents, and the timing of adding the organic solvents, and compared the characteristics of each group. Results: Tensile strength, physical activity, and thermal stability tests revealed that the tissues fixed with glutaraldehyde were better with regard to mechanical strength and biochemical durability. However, the difference was not significant statistically. Conclusion: Genipin can be used as an alternative crosslinking agent for pericardial tissue, considering given its physical, mechanical, biochemical characteristics and low cytotoxicity comparable to glutaraldehyde. However, further studies are needed on the immune reaction and the long term changes in genipin-fixed tissues in the human body.

Early Clinical Outcomes of Tricuspid Valve Repair with a Tri-Ad Annuloplasty Ring in Comparison with the Outcomes Using an MC3 Ring

  • Jung, Woohyun;Choi, Jae Woong;Hwang, Ho Young;Kim, Kyung Hwan
    • Journal of Chest Surgery
    • /
    • v.51 no.2
    • /
    • pp.92-99
    • /
    • 2018
  • Background: We evaluated the early clinical outcomes of tricuspid valve annuloplasty (TAP) with the Tri-Ad annuloplasty ring for functional tricuspid regurgitation (TR). Methods: From January 2015 to March 2017, 36 patients underwent TAP with a Tri-Ad ring for functional TR. To evaluate the early clinical outcomes of TAP with the Tri-Ad ring, we conducted a propensity score-matched analysis comparing the Tri-Ad and $MC^3$ tricuspid annuloplasty rings (n=34 in each group). The follow-up duration was $11.0{\pm}7.07$ months. Results: There was 1 case of operative mortality (2.8%) and no cases of late mortality. Postoperative complications occurred in 15 patients (41%), including acute kidney injury in 6 patients (16%), bleeding requiring reoperation in 4 patients (11%), and low cardiac output syndrome in 4 patients (11%). There were no ring-related complications, such as atrioventricular block or ring dehiscence. The TR grade decreased significantly (from $2.03{\pm}1.06$ to $1.18{\pm}0.92$, p<0.01), as did the systolic pulmonary artery pressure (from $43.53{\pm}13.84$ to $38.00{\pm}9.72mm\;Hg$, p=0.03). There were no cases of severe residual TR, but moderate TR was observed in 3 patients, all of whom had severe TR preoperatively. Severe preoperative TR was also associated with moderate in the univariate analysis (p<0.01). In the propensity score-matched analysis comparing the Tri-Ad and $MC^3$ rings, there was no significant difference in early clinical outcomes. Conclusion: TAP with the Tri-Ad ring corrected functional TR effectively and provided good early clinical and echocardiographic results without ring-related complications. However, severe preoperative TR was associated with moderate or severe residual TR in the immediate postoperative period. A follow-up study is necessary to confirm the stability of this procedure.

A Three-Dimensional Deep Convolutional Neural Network for Automatic Segmentation and Diameter Measurement of Type B Aortic Dissection

  • Yitong Yu;Yang Gao;Jianyong Wei;Fangzhou Liao;Qianjiang Xiao;Jie Zhang;Weihua Yin;Bin Lu
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.168-178
    • /
    • 2021
  • Objective: To provide an automatic method for segmentation and diameter measurement of type B aortic dissection (TBAD). Materials and Methods: Aortic computed tomography angiographic images from 139 patients with TBAD were consecutively collected. We implemented a deep learning method based on a three-dimensional (3D) deep convolutional neural (CNN) network, which realizes automatic segmentation and measurement of the entire aorta (EA), true lumen (TL), and false lumen (FL). The accuracy, stability, and measurement time were compared between deep learning and manual methods. The intra- and inter-observer reproducibility of the manual method was also evaluated. Results: The mean dice coefficient scores were 0.958, 0.961, and 0.932 for EA, TL, and FL, respectively. There was a linear relationship between the reference standard and measurement by the manual and deep learning method (r = 0.964 and 0.991, respectively). The average measurement error of the deep learning method was less than that of the manual method (EA, 1.64% vs. 4.13%; TL, 2.46% vs. 11.67%; FL, 2.50% vs. 8.02%). Bland-Altman plots revealed that the deviations of the diameters between the deep learning method and the reference standard were -0.042 mm (-3.412 to 3.330 mm), -0.376 mm (-3.328 to 2.577 mm), and 0.026 mm (-3.040 to 3.092 mm) for EA, TL, and FL, respectively. For the manual method, the corresponding deviations were -0.166 mm (-1.419 to 1.086 mm), -0.050 mm (-0.970 to 1.070 mm), and -0.085 mm (-1.010 to 0.084 mm). Intra- and inter-observer differences were found in measurements with the manual method, but not with the deep learning method. The measurement time with the deep learning method was markedly shorter than with the manual method (21.7 ± 1.1 vs. 82.5 ± 16.1 minutes, p < 0.001). Conclusion: The performance of efficient segmentation and diameter measurement of TBADs based on the 3D deep CNN was both accurate and stable. This method is promising for evaluating aortic morphology automatically and alleviating the workload of radiologists in the near future.

Experimental Study of Surface Activity in Acute Pulmonary Edema (급성 폐수종에서의 Pulmonary Surfactant 에 관한 연구)

  • 김진식;홍완일
    • Journal of Chest Surgery
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 1974
  • Acute pulmonary edema was induced by intravenous injection of epinephrine, intravenous infusion of dextran and intratracheal instillation of acid solution index was determined from pressure volume curves in excised lungs. Surface activity was also investigated with measurements of maximum and minimum surface tension and stability index on saline extracts of same lungs. The results were as follows. 1. The expansion index of excised lung in which pulmonary edema was induced by intravenous injection of epinephrine, intravenous infusion of dextran and intratracheal instillation of acid solution was ignificantly decreased as compared with the normal control of $0.86{\pm}0.017$ to $0.74{\pm}0.03$, $0.71{\pm}0.081$and $0.76{\pm}0.02$, respectively. 2. The deflation curves of excised lungs in which pulmonary edema was induced were significantly decreased as compared with the normal controls. 3. The minimum surface tension of excised lung in which pulmonary edema was induced was significantly increased in each groups and stability index was significantly decreased as compared with the normal controls 0.78 to $0.35{\pm}0.039$, $0.29{\pm}0.02 $ and $0.31{\pm}0.083$, respectively. 4. The decrease of pulmonary surface activity in acute pulmonary edema was in proportion to the degree of pulmonary edema regardless of their etiology.

  • PDF

A Study on Analysis of Heart Rate Variability Using Fractal Dimension (FRACTAL 차원을 이용한 심박변화 분석에 관한 연구)

  • Lee, Byung-Chae;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.169-171
    • /
    • 1994
  • This paper is to find out more reliable analyzing method of heart rate variability. Heart rate variability analysis is to evaluate cardiovascular stability and also have used as an indicator of autonomic nervous system activity. In this study, time domain analysis, spectral analysis and state space analysis method are applied to analyze heart rate variability. Because of nonlinear characteristics of heart rate, we need not only spectral analysis, but also state space analysis. Fractal dimension of spectral estimation is useful indicator of autonomic nervous activity.

  • PDF

A Review of Anesthesia for Lung Transplantation

  • Kim, Hye-Jin;Shin, Sang-Wook;Park, Seyeon;Kim, Hee Young
    • Journal of Chest Surgery
    • /
    • v.55 no.4
    • /
    • pp.293-300
    • /
    • 2022
  • Lung transplantation is the only treatment option for patients with end-stage lung disease. Although more than 4,000 lung transplants are performed every year worldwide, the standardized protocols contain no guidelines for monitoring during lung transplantation. Specific anesthetic concerns are associated with lung transplantation, especially during critical periods, including anesthesia induction, the initiation of positive pressure ventilation, the establishment and maintenance of one-lung ventilation, pulmonary artery clamping, pulmonary artery unclamping, and reperfusion of the transplanted lung. Anesthetic management according to the special risks associated with a patient's existing lung disease and surgical stage is the most important factor. Successful anesthesia in lung transplantation can improve hemodynamic stability, oxygenation, ventilation, and outcomes. Therefore, anesthesiologists must have expertise in transesophageal echocardiography, extracorporeal life support, and cardiopulmonary anesthesia and understand the pathophysiology of end-stage lung disease and the drugs administered. In addition, communication among anesthesiologists, surgeons, and perfusionists during surgery is important to achieve optimal patient results.

Comparison of the Uniaxial Tensile Strength, Elasticity and Thermal Stability between Glutaraldehyde and Glutaraldehyde with Solvent Fixation in Xenograft Cardiovascular Tissue (이종심혈관 조직에 대한 글루타알데하이드 및 용매를 첨가한 고정방법에 따른 장력, 탄력도 및 열성 안정성 비교연구)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Kim, Wong-Han
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.165-174
    • /
    • 2009
  • Background: With the advances of cardiac surgery, the demand for an artificial prosthesis has increased, and this has led to the development and utilization of diverse alternative materials. We conducted this research to improve an artificial prosthesis by examining the changes of the physical qualities, the pressure related tensile strength, the change in elasticity and the thermostability of a xenograft valve (porcine) and pericardium (bovine, porcine) based on the type of fixation liquid we used. Material and Method: The xenograft valves and pericardium were assigned into three groups: the untreated group, the fixed with glutaraldehyde (GA) group and the glutaraldehyde with GA+solvent such as ethanol etc. group. The surgeons carried out each group's physical activities. Each group's uniaxial tension and elasticity was measured and compared. Thermostability testing was conducted and compared between the bovine and porcine pericardium fixed with GA group and the GA+solvent group. Result: On the physical activity test in the surgeon's hand, no significant difference between the groups was sensed on palpation. For suture and tension, the GA+solvent group was slightly firmer than the low GA concentration group. In general, the circumferential uniaxial tension and elasticity of the porcine aortic and pulmonary valves were better in the fixed groups than that in the untreated group. There was no significant difference between the GA and GA+solvent groups (p>0.05). Bovine and porcine pericardium also showed no significant difference between the GA group and the GA+solvent group (p>0.05). When comparing between the groups for each experiment, the elasticity tended to be stronger in most of the higher GA concentration group (porcine pulmonary valve, porcine pericardium). On the thermostability testing of the bovine and porcine pericardium, the GA group and the G+solvent group both had a sudden shrinking point at $80^{\circ}C$ that showed no difference (bovine pericardium: p=0.057, porcine pericardium: p=0.227). Conclusion: When fixing xenograft prosthetic devices with GA, adding a solvent did not cause a loss in pressure-tension, tension-elasticity and thermostability. In addition, more functional solvents or cleansers should be developed for developing better xenografts.

An Influence of Modified Robicsek Sternal Wiring after Median Sternotomy on the Postoperative Sternal Wound Infection (정중 흉골 절개 후 시행한 변형 Robicsek 흉골 봉합법이 수술 후 흉골감염에 미치는 영향)

  • Chang, Won-Ho;Youm, Wook;Kim, Dong-Hyun;Oh, Hong-Chul;Han, Jung-Wook;Kim, Hyun-Jo
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.763-769
    • /
    • 2009
  • Background: In the majority of cases, sternal instability and wound infection concomitantly present after a cardiac operation following conventional median sternotomy, and these complications have a major influence on the postoperative course. The aim of this study is to compare the results of the different sternal wiring techniques of sternal infection. Material and Method: Between April 2004 and December 2008, 157 adult patients underwent cardiac in group A, whereas 71 patients who had undergone modified Robicsek sternal wiring were included in group B. The incidences of sternal wound complications in the two groups were assessed. Result: The mean age of the group B patients was older than that of the group A patients ($61{\pm}10$ years vs $57{\pm}13$ years). The incidence of preoperative left ventricular dysfunction (ejection fraction <30%), chronic obstructive pulmonary disease, renal failure requiring dialysis and diabetes mellitus were significantly higher in Group B, whereas the other perioperative risk factors for infection were not significantly different between the two groups. Two patients in group A experienced superficial wound infection, whereas 4 patients in group B displayed superficial wound infection, but the difference was not statistically significant (p=0.255). Yet poststernotomy deep sternal wound infection appeared in 6 patients of group A, whereas none of the patients in group B displayed this malady. Conclusion: The modified Robicsek sternal wiring technique showed greater sternal stability even for the patient with a high risk for infection, and the technique caused a lower incidence of deep sternal wound infection.

Development and assessment of nano drug delivery systems for combined delivery of rosuvastatin and ezetimibe

  • Mohamed Ali Metwally;El-Yamani Ibrahim El-Zawahry;Maher Amer Ali;Diaa Farrag Ibrahim;Shereen Ahmed Sabry;Omnia Mohamed Sarhan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.28 no.3
    • /
    • pp.275-284
    • /
    • 2024
  • Worldwide, cardiovascular disease is the main cause of death, which accordingly increased by hyperlipidemia. Hyperlipidemia therapy can include lifestyle changes and medications to control cholesterol levels. Statins are the medications of the first choice for dealing with lipid abnormalities. Rosuvastatin founds to control high lipid levels by hindering liver production of cholesterol and to achieve the targeted levels of low-density lipoprotein cholesterol, another lipid lowering agents named ezetimibe may be used as an added therapy. Both rosuvastatin and ezetimibe have low bioavailability which will stand as barrier to decrease cholesterol levels, because of such depictions, formulations of this combined therapy in nanotechnology will be of a great assistance. Our study demonstrated preparations of nanoparticles of this combined therapy, showing their physical characterizations, and examined their behavior in laboratory conditions and vivo habitation. The mean particle size was uniform, polydispersity index and zeta potential of formulations were found to be in the ranges of (0.181-0.72) and (-13.4 to -6.24), respectively. Acceptable limits of entrapment efficiency were affirmed with appearance of spherical and uniform nanoparticles. In vitro testing showed a sustained release of drug exceeded 90% over 24 h. In vivo study revealed an enhanced dissolution and bioavailability from loaded nanoparticles, which was evidenced by calculated pharmacokinetic parameters using triton for hyperlipidemia induction. Stability studies were performed and assured that the formulations are kept the same up to one month. Therefore, nano formulations is a suitable transporter for combined therapy of rosuvastatin and ezetimibe with improvement in their dissolution and bioavailability.