• Title/Summary/Keyword: Cardiovascular flow

Search Result 598, Processing Time 0.038 seconds

Spectral Element Modeling for the Blood Flow through Artery (동맥 유동해석을 위한 스펙트럴 요소의 개발)

  • Jang, In-Joon;Seo, Bo-Sung;Lee, U-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.383-386
    • /
    • 2007
  • As the blood flow characteristics have been recognized to be closely related to various cardiovascular diseases, it is very important to predict them accurate enough in an efficient way. Thus, this paper proposes a one-dimensional spectral finite element model for the human blood vessels. The spectral finite element model is formulated in the frequency-domain by using the exact frequency dependent shape functions and applied to an ascending aorta.

  • PDF

Early Aortic Valve Replacement in Symptomatic Normal-Flow, Low-Gradient Severe Aortic Stenosis: A Propensity Score-Matched Retrospective Cohort Study

  • Kyu Kim;Iksung Cho;Kyu-Yong Ko;Seung-Hyun Lee;Sak Lee;Geu-Ru Hong;Jong-Won Ha;Chi Young Shim
    • Korean Circulation Journal
    • /
    • v.53 no.11
    • /
    • pp.744-755
    • /
    • 2023
  • Background and Objectives: Aortic valve replacement (AVR) is considered a class I indication for symptomatic severe aortic stenosis (AS). However, there is little evidence regarding the potential benefits of early AVR in symptomatic patients diagnosed with normal-flow, low-gradient (NFLG) severe AS. Methods: Two-hundred eighty-one patients diagnosed with symptomatic NFLG severe AS (stroke volume index ≥35 mL/m2, mean transaortic pressure gradient <40 mmHg, peak transaortic velocity <4 m/s, and aortic valve area <1.0 cm2) between January 2010 and December 2020 were included in this retrospective study. After performing 1:1 propensity score matching, 121 patients aged 75.1±9.8 years (including 63 women) who underwent early AVR within 3 months after index echocardiography, were compared with 121 patients who received conservative care. The primary outcome was a composite of all-cause death and heart failure (HF) hospitalization. Results: During a median follow-up of 21.9 months, 48 primary outcomes (18 in the early AVR group and 30 in the conservative care group) occurred. The early AVR group demonstrated a significantly lower incidence of primary outcomes (hazard ratio [HR], 0.52; 95% confidence interval [CI], 0.29-0.93; p=0.028); specifically, there was no significant difference in all-cause death (HR, 0.51; 95% CI, 0.23-1.16; p=0.110), although the early AVR group showed a significantly lower incidence of hospitalization for HF (HR, 0.43; 95% CI, 0.19-0.95, p=0.037). Subgroup analyses supported the main findings. Conclusions: An early AVR strategy may be beneficial in reducing the risk of a composite outcome of death or hospitalization for HF in symptomatic patients with NFLG severe AS. Future randomized studies are required to validate and confirm our findings.

Evaluation of the Potential of Retrograde Flow Competition in the Right Gastroepiploic Artery Graft for Coronary Artery Bypass Grafting (우위대망동맥을 이용한 관상동맥우회술 후 역행성 혈류 발생가능성의 연구)

  • Chung, Bong-Kyu;Sun, Kyung;Kwon, Joon;Kim, Kwang-Ho;Jung, Jae-Seung;Son, Ho-Sung;Lee, Sung-Ho;Kim, Kwang-Taik;Kim, Hyung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.1
    • /
    • pp.20-26
    • /
    • 2002
  • Background: Due to the concern of flow competition or retrograde steal, it has been generally suggested that the right gastroepiploic artery(RGEA) pedicled graft should be used in critical coronary stenosis lesion. The study was designed to evaluate the potential of retrograde flow competition in the RGEA pedicled graft by measuring the native pressure differences(PD) between the normal coronary artery and celiac arterial pressure, which would be compared with trans-stenosis pressure gradients(TSPG) in coronary artery occlusive disease. Material and Method: Between July, 1998 and February, 1999, pressures of the right coronary artery and the right gastroepiploic artery(or the celiac artery) were measured in patients with the patent right coronary artery(n=12). The PD between the arteries was compared with the TSPG in the occlusive coronary arteries(n=32). Result: The pressures of the normal right coronary artery and celiac artery were 143$\pm$23 vs. 134$\pm$17mmHg in systole(p<0.005), 74$\pm$13 vs. 73$\pm$14mmHg in diastole(p=NS), and 100$\pm$16 vs. 97$\pm$15mmHg in mean (p<0.05). The PD between the arteries were -8~25mmHg in systole, -4~7mmHg in diastole, and -1~10mmHg in mean. The TSPG measured in the occlusive coronary arteries were -4~19(7$\pm$5.8)mmHg in the lesion less than 75% stenosis vs. 7~74(27$\pm$18.3)mmHg in the 75% or over stenosis lesion(p<0.005). The normally existing pressure difference between the coronary arteries and RGEA(15~20mmHg) was significantlyless than the TSPG in .the occlusive coronary artery with 75% or over stenosis(p<0.001). Conclusion: If the pressure gradient between the RGEA and the coronary artery distal to the stenosis is the main determinant of development of retrograde flow competiton in the RGEA pedicled graft, the above data suggests that there will be little chance of competition when It is used in the coronary lesion with 75% or over stenosis.

Effect of LI4-LI11 Transcutaneous Electrical Nerve Stimulation on Regional Cerebral Blood Flow in Healthy Human Using SPECT and Statistical Parametric Mapping (뇌 SPECT와 SPM을 이용한 합곡-곡지 TENS 치료의 뇌혈류에 대한 효과)

  • Jeong, Dong-Won;Kim, Young-Suk;Park, Seong-Uk;Jung, Woo-Sang;Park, Jung-Mi;Ko, Chang-Nam;Cho, Ki-Ho;Bae, Hyung-Sup;Kim, Deok-Yoon;Moon, Sang-Kwan
    • The Journal of Korean Medicine
    • /
    • v.29 no.4
    • /
    • pp.205-212
    • /
    • 2008
  • Background and purpose: So far it was reported that acupuncture increased cerebral blood supply and stimulated the functional activity of brain nerve cells. A previous study demonstrated a correlation between LI4-11 electro-acupuncture (EA) and rCBF increase in frontal lobe. However, there remained a need to study further using various controls in acupuncture research. Transcutaneous electrical nerve stimulation (TENS) has been used as a non-invasive control in acupuncture study. This study was to evaluate the effect of LI4-LI11 TENS on regional cerebral blood flow (rCBF) in normal volunteers using single photon emission computed tomography (SPECT) and statistical parametric mapping (SPM). Methods: In the resting state, $^{99m}Tc-ECD$ brain SPECT scans were performed on 10 normal volunteers (9 males, 1 female, mean age 26.6$\pm$0.5 years; age range from 26 to 27 years). On the other day, 7 days after the resting examination, 15 minute TENS were applied at LI 4 and LI 11 on the right side of the subjects. Immediately after LI4-LI11 TENS, the second SPECT images were obtained in the same manner as the resting state. Significant increases and decreases of regional cerebral blood flow after LI4-LI11 TENS were estimated by comparing their SPECT images with those of the resting state using paired t statistics at every voxel, which were analyzed by statistical parametric mapping with a threshold of p = 0.001, uncorrected (extent threshold: k=100 voxels). Results: TENS applied at right LI4-LI11 increased rCBF in the left somatosensory association cortex (Brodmann area 5, 7). However there was no area where LI4-11 TENS decreased rCBF. Conclusion and suggestions: These results demonstrate that right LI4-LI11 TENS increased rCBF only in corresponding somatosensory association cortex, which was different from the previous results using LI4-11 EA. It is suggested that there be a different mechanism between TENS and EA.

  • PDF

Hybrid Technique to Correct Cerebral Malperfusion Following Repair of a Type A Aortic Dissection

  • Kim, Seon Hee;Song, Seunghwan;Kim, Sang-Pil;Lee, Jonggeun;Lee, Han Cheol;Kim, Eun Soo
    • Journal of Chest Surgery
    • /
    • v.47 no.2
    • /
    • pp.163-166
    • /
    • 2014
  • A 49-year-old man with drowsy mentality was diagnosed with acute type A aortic dissection; he underwent an emergency operation. When selective antegrade cerebral perfusion was initiated, the right regional cerebral oxygen saturation ($rSO_2$) decreased as compared to the left one. Adequate blood flow was perfused through the branch of the artificial graft, after distal anastomosis, but the right $rSO_2$ did not recover. Angiography revealed another intimal tear on the right common carotid artery. A stent was then inserted. The right $rSO_2$ promptly increased to the same level as that of the left one. The patient was discharged without any neurologic complications.

Treatment of Refractory Chylous Ascites with an Innovative Peritoneovenous Shunt: Temporary Usage of a Continuous Renal Replacement System: A Case Report

  • Park, Jiyoun;Lee, Jae Jun;Lee, Jung Hee;Shim, Young Mog
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.81-84
    • /
    • 2022
  • Esophagectomy and esophageal reconstruction are commonly chosen as surgical options for esophageal cancer. However, prolonged untreated chyle leakage is associated with a poor prognosis. We report the case of a patient with refractory chylous ascites. To limit the ongoing fluid loss, we utilized the chylous ascites as an additional fluid source in a renal replacement therapy system. A continuous renal replacement therapy (CRRT) drainage system was modified to drain both the chylous ascites and venous blood. The ascites drainage rate was determined empirically and regulated by a dial-flow extension set. The CRRT mode was set to continuous venovenous hemodiafiltration and maintained for 7 days. After the patient was weaned from CRRT, ascites did not reaccumulate, and the patient's general condition improved dramatically. No infections related to the system occurred. This procedure temporarily alleviates symptoms and provides more time for alternative treatment strategies.

Percutaneous OxyRVAD in a Patient with Severe Respiratory Failure and Right Heart Failure: A Case Report

  • Ga Young Yoo;June Lee;Seok Beom Hong;Do Yeon Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.3
    • /
    • pp.319-322
    • /
    • 2024
  • Venovenous extracorporeal membrane oxygenation (VV ECMO) is often used in cases of severe respiratory failure, especially in patients considered for lung transplantation. However, because many lung diseases can ultimately result in right heart failure, the treatment of secondary right heart failure can present a challenge when the patient is already under VV ECMO support. In such cases, an oxygenated-right ventricular assist device (OxyRVAD) can be used. OxyRVAD is designed to maintain anterograde blood flow and prevent right ventricular distension. Moreover, the pulmonary arterial cannula can be inserted percutaneously. We report a case in which percutaneous OxyRVAD was successfully implemented to manage right heart failure in a patient with respiratory failure who was on VV ECMO.

Total Arterial Revascularization Using Y-composite Graft for Isolated Left Main Coronary Artery Disease (단독 좌주간 관동맥 협착병변에서 Y-도관을 이용한 완전 동맥도관 관상동맥우회로 조성술)

  • Ahn, Byong-Hee;Yu, Ung;Chun, Joon-Kyung;Ryu, Sang-Wan;Choi, Yong-Sun;Kim, Byong-Pyo;Hong, Sung-Bum;Bum, Min-Sun;Na, Kook-Ju;Jung, Myung-Ho;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.35-42
    • /
    • 2004
  • Background: For the treatment of isolated left main coronary artery disease, twelve arterial revascularizations with Y-composite grafts using left internal thoracic artery and radial artery or right gastroepiploic artery were peformed. This study was performed to investigate whether V-composite graft can satisfy the blood flow required to make myocardium act properly or not. Borderline stenotic lesions on the left main coronary artery, which are very prone to remodel the bypassed vessels due to competitive flows, were also considered. Material and Method: Among 247 patients who underwent coronary artery bypass grafting from March 2000 to April 2003, 12 patients (4.7%) who had received total arterial revascularizations for the isolated left main coronary artery disease were studied retrospectively. Result: left anterior descending arteries were bypassed with left internal thoracic artery by off-pump technique in all patients, however, 2 cases of left obtuse marginal branches were bypassed under on-pump beating heart. Except for one patient, who did not have an obtuse marginal branch more than 1 mm in diameter, 11 patients had gone through complete arterial revascularizations by use of the Y shape arterial graft. Among five patients who had less than 75% stenosis, one patient showed string sign on left internal thoracic artery grafted to left anterior descending artery. However, two grafts to obtuse marginal blanches were completely obstructed and one showed slender sign. There were no graft-dominant flow in patients with stenotic lesion less than 75%. On the contrary to the result of patients with stenotic lesions less than 75%, all the patients with stenotic lesions more than 90% showed graft-dominant blood flow. Conclusion: In conclusion, it is assumed that, when stenotic lesions are over 90%, coronary artery bypass grafting with an Y shape arterial graft could possibly give enough help to the obstructed coronary arteries in blood supplying to myocardium, which needs massive quantity of blood to act well. However, when patients have borderline stenoses, through scrupulous examinations, more prudent and flexible decisions are required in choosing the treatment methods, such as, direct anastomosis of vein or artery to aorta, or adding supplementary treatment methods like percutaneous coronary intervention, rather than choosing a fixed treatment methods.

Numerical Study of Effect of counter-pulsation on Hemodynamic Response in the ECLS (체외생명구조장치에서 역박동 방법이 혈류역학 응답에 미치는 영향에 대한 수치적 연구)

  • Kim, In-Su;Lim, Ki-Moo;Choi, Seoung-Wook;Jun, Hyung-Min;Shim, Eun-Bo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1660-1664
    • /
    • 2008
  • Extra-corporeal Life Support System (ECLS) is the device used in emergency cases to substitute a extracorporeal circulation in open heart surgery, cardiac arrest or in acute cardiopulmonary failure. To obtain the effect of counter-pulsation on hemodynamic response in the ECLS quantitatively, we developed cardiovascular model which consists of 12 compartment model of heldt et al. and 3 compartment model of Schreiner et al. based on windkessel approximation. We compared coronary perfusion, arterial pulse pressure, cardiac output, and left ventricular pressure-volume diagram according to flow configuration such as counter-pulsation, copulsation, and continous flow. When counter-pulsation was applied, 5% higher coronary perfusion, 26% lower pulse pressure, and 2% higher cardiac output than copulsation condition were calculated. We conclude that counter-pulsation configuration in the ECLS is hemodynamically more stable than copulsation and influences the positive effect to recover ventricles.

  • PDF