• Title/Summary/Keyword: Cardiopulmonary Bypass

Search Result 676, Processing Time 0.021 seconds

Comparative Analysis of Medical Terminology Among Korea, China, and Japan in the Field of Cardiopulmonary Bypass (한.중.일 의학용어 비교 분석 - 심폐바이패스 영역를 중심으로 -)

  • Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.159-167
    • /
    • 2007
  • Background: Vocabularies originating from Chinese characters constitute an important common factor in the medical terminologies used 3 eastern Asian countries; Korea, China and Japan. This study was performed to comparatively analyze the medical terminologies of these 3 countries in the field of cardiopulmonary bypass (CPB) and; thereby, facilitate further understanding among the 3 medical societies. Material and Method: A total of 129 English terms (core 85 and related 44) in the field of CPB were selected and translated into each country's official terminology, with help from Seoul National University Hospital (Korea), Tokyo Michi Memorial Hospital(Japan), and Yanbian Welfare Hospital and Harbin Children Hospital (China). Dictionaries and CPB textbooks were also cited. In addition to the official terminology used in each country, the frequency of use of English terms in a clinical setting was also analyzed. Result and Conclusion: Among the 129 terms, 28 (21.7%) were identical between the 3 countries, as based on the Chinese characters. 86 terms were identical between only two countries, mostly between Korea and Japan. As a result, the identity rate in CPB terminology between Korea and Japan was 86.8%; whereas, between Korea and China and between Japan and China the rates were both 24.8%. The frequency of use of English terms in clinical practices was much higher in Korea and Japan than in China. Despite some inherent limitations involved in the analysis, this study can be a meaningful foundation in facilitating mutual understanding between the medical societies of these 3 eastern Asian countries.

Monitoring of Activated Coagulation Time with Kaolin vs. Celite Activator in Cardiac Surgical Patients with Aprotinin (Aprotinin을 투여한 개심술 환자에서 Kaolin과 Celite Activator를 이용한 Activated Coagulation Time(ACT) 측정의 비교)

  • Kim, Joung-Taek;Sun, Kyung;Lee, Choon-Soo;Baik, Wan-Ki;Cho, Sang-Rock;Kim, Hyun-Tae;Kim, Hea-Sook;Park, Hyun-Hee;Kim, Kwang-Ho
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.873-876
    • /
    • 1998
  • Background: High-dose aprotinin has been reported to enhance the anticoagulant effects of heparin during cardiopulmonary bypass ; hence, som authors have advocated reducing the dose of heparin in patients treated with aprotinin. Material and Method: The ACT was measured before, during and after cardiopulmonary bypass, with Hemochron 801 system using two activators of celite(C-ACT) and kaolin(K- ACT) as surface activator. From June, 1996 to February, 1997, 22 adult patients who were scheduled for elective operation were enrolled in this study. Result: The ACT without heparin did not differ between C-ACT and K-ACT. At 30 minutes after anticoagulation with heparin and cardiopulmonary bypass, the average C-ACT was 928${\pm}$400 s; K-ACT was 572${\pm}$159s(p<0.05). After administration of protamine, C-ACT was 137${\pm}$26 s; K-ACT was 139${\pm}$28s, which were not statistically significant. Conclusion: Our results showed that the significant increase in the ACT during heparin- induced anticoagulation in the presence of aprotinin was due to the use of celite as surface activator, rather than due to enhanced anticoagulation of heparin by aprotinin. We conclude that the ACT measured with kaolin provides better monitoring of cardiac surgical patients treated with high dose aprotinin than does the ACT measured with celite. The patients treated with aprotinin should receive the usual doses of heparin.

  • PDF

Postcardiotomy Ventricular Support with Biomedicus Pump (Biomedicus pump를 이용한 개심술후 심실보조)

  • Kim, Won-Gon;Lee, Chang-Ha;Kim, Ki-Bong;Ahn, Hyuk;Rho, Ryang-Joon
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1218-1222
    • /
    • 1996
  • The reported incidence of postcardiotomy cardiogenic shock not responding to conventional therapy is still 0.1 to 0.8%. For this group of patients, more aggressive form of circulatory support must be employed. Centrifugal pumps are a ventricular assist device most commonly used on this purpose, due to low cost and easy availability. Currently, however, clinical experience of centrifugal pumps as a ventricular assist device is rarely reported in Korea. From January 1992 to January 1996, 2986 patients underwent cardiac operations on cardiopulmonary bypass at Seoul National University Hospital. Refractory postcardiotomy cardiac failure requring ventricular support with a Biomedicus centrifugal pump developed in ten of these patients. There were eight men and two women, ranged in age from nine years to 77 years with a mean of 50$\pm$20 years. The primary surgical procedures consisted of isolated coronary revascularization in four patients, combined coronary revascularization and aortic valve replacement in two, aortic dissection repair in two, pulmonary embolectomy in one, and heart transplantation in one. Of the ten patients, five had left ventricular assistance, one had right ventricular assistance, and four had biventricular assistance. Duration of ventricular assistance ranged from 24 to 175 hours, with a mean of 76$\pm$51 hours. Seven patients were weaned from ventricular assistance, and four of them discharged. The causes of death for nonsurvivors were progressive cardiac failure in two patients and multiorgan failure, intractable ventricular fibrillation, irreversible brain injury, and mechanical problem, respectively, in the other four. Survival was not predicted by time on cardiopulmonary bypass, aortic cross-clamp time, or duration of ventricular support. Major complications included bleeding(7), renal failure(6), infection(3) and neurologic complication(2). These results indicate that a centrifugal pump can provide reasonably satisfactory short-term circulatory support.

  • PDF

Open Heart Surgery for Six Cases of the Conegnital Heart Disease (선천성(先天性) 심장병(心臟病)의 개심술(開心術) -6례(例) 수술경험(手術經驗) -)

  • Lee, Sung Haing;Lee, Sung Koo;Han, Sung Sae;Lee, Kihl Rho;Kim, Song Myung;Lee, Kwang Sook;Lee, Chong Kook
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.220-238
    • /
    • 1976
  • Six cases of congenital heart disease were operated on by means of cardiopulmonary bypass between December, 1975 and April, 1976. Two cases of ventricular septal defects (VSD), two cases of VSD, associated with ruptured aneurysm of sinus Valsalva, two cases of atrial septal defects (ASD) and one case of pulmonic stenosis with patent ductus arteriosus were operated. Sarns roller pumps and Bentley Temptrol oxygenators were used for extracorporeal circulation. Pump oxygenator was primed with Ringer's lactate solution, 5% dextrose in water, mannitol, and ACD blood. Flow rate ranged from 2.0 to $2.4L/M^2/min$. Bicarbonate was added to the oxygenator with estimated amount as 15 mEq/L/hr. Venous catheters were introduced into superior and inferior vena cava, and oxygenated blood was returned to the body through aortic cannula inserted into ascending aorta. Moderate hypothermia ($30^{\circ}C$) was induced by core cooling. Aorta was cross clamped for 15 minutes and released for 3 minutes, and repeated clamping when necessary. Atrial and ventricular septal efects were closed by direct sutures. Aneurysms of sinus Valsalva ruptured into the right ventricle were repaired through right ventriculotomy by d:rect closure with Dacron patch reinforcement. Cardiopulmonary bypass time varied from 66 to 209 minutes, and aorta cross clamping time ranged from 13 to 56 minutes. Postoperative bleeding was minimal except one case who needed for evacuation of substernal hematoma. Intra- and postoperative urinary output was satisfactory. Acid-base balance, partial pressure of $O_2$, electrolytes, and hematological changes during intra- and post-perfusion period remained at the acceptable ranges. No mortality was experienced.

  • PDF

Renal Leiomyosarcoma with an Extension of the Tumor Thrombi into the IVC and the RA -One of case - (하대정맥과 우심방의 종양혈전을 동반한 신평활근육종 - 1예 보고 -)

  • Chung, Ki-Chun;Lee, Chul-Burm;Chon, Soon-Ho;Kim, Sang-Heon;Kim, Hyuck;Chung, Won-Sang;Kim, Young-Hak;Kang, Jung-Ho
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.970-974
    • /
    • 2003
  • There has been an improvement in the prognosis of tumor thrombi invading the inferior vena cava(IVC) and the right atrium(RA) of renal cell carcinoma with radical nephrectomy and tumor thrombectomy with the aid of cardiopulmonary bypass in the last 10 years. A 30 year old woman was diagnosed with right renal tumor with tumor thrombi invading the right renal vein and the IVC above the right renal vein to the RA. She received radical nephrectomy and removal of tumor thrombi in the infrarenal IVC under hypothermic total circulatory arrest using the cardiopulmonary bypass. The tumor recurred 12 months after the initial operation, she received a second operation for tumor removal from the retroperitoneum, suprarenal IVC, and RA. She died 11 months after the second operation due to lung metastases and recurred hepatic vein tumor extended to the RA and right ventricle.

Epicardial Repair of Acute Atrioventricular Groove Disruption Complicating Mitral Valve Replacement - A case report - (승모판막치환술 후 발생한 급성 제1형 좌심실 파열에 대한 심외막적 봉합 - 1예 보고 -)

  • Cho, Kwang-Ree;Kang, Jae-Geul;Jin, Sung-Hoon
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.855-858
    • /
    • 2007
  • A left ventricular rupture might be one of the most disastrous complications after a mitral valve replacement. An acute atrioventricular groove rupture (type I) was detected in a 54-year-old female diagnosed with a mitral stenosis combined with severe tricuspid regurgitation. She had a prior medical history of an open mitral commissurotomy in Japan at 30 years ago. The surgical findings suggested that the previous procedure was not a simple commissurotomy but a commissurotomy combined with a posteromedial annuloplasty procedure. After a successful mitral valve replacement and a measured (De Vega type) tricuspid annuloplasty, the weaning from a cardiopulmonary bypass was uneventful. However, copious intraoperative bleeding from the posterior wall was detected and the cardiopulmonary bypass was restarted. Exposure of the posterior wall of the left ventricle showed bleeding from the atrioventricular groove 3 cm lateral to the left atrial auricle. Under the impression of a Type I left ventricular rupture, epicardial repair (primary repair of the Teflon felt pledgetted suture, continuous sealing suture using auto-pericardial patch and application of fibrin-sealant) was attempted. Successful local control was made and the patient recovered uneventfully. The patient was discharged at 14 postoperative days without complications. We report this successful epicardial repair of an acute type I left ventricular rupture after mitral valve replacement.

Comparative Studies of Pulsatile and Nonpulsatile Blood Flow during Cardiopulmonary Bypass (박동류 및 비박동류에 의한 체외순환의 비교)

  • Sun, Kyung;Baek, Kwang-Je;Kim, Yo-Han;Kim, Chang-Young;Kim, Kwang-Taek;Kim, Hark-Jei;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.182-192
    • /
    • 1985
  • [here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.

  • PDF

Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion (상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF

A clinical study on the effects of myocardial protection during open heart surgery (개심술에서 술중 심근보호효과에 관한 임상적연구)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.230-240
    • /
    • 1987
  • Cardioplegia and myocardial protection were performed under cardiopulmonary bypass during open-heart surgery with the use of cold St. Thomas Hospital cardioplegic solution [4=C] for the coronary artery perfusion and normal saline solution [4- C] for the topical cardiac cooling. To maintain the state of myocardial protection, coronary artery reperfusion was carried out using St. Thomas Hospital cardioplegic solution at the interval of 30 minutes. A total number of patients studied were 57 cases, including 37 cases of correction for congenital cardiac anomalies and 20 cases for acquired heart valvular diseases. Cardiopulmonary bypass time during the surgery was observed to be average of 87.89*47.55 hours, aortic cross-clamping time to be average of 76.68~44.27 hours raging from 30 to 191 minutes. In order to evaluate the effects of myocardial protection in the surgery, serum enzyme levels were determined. To observe the relationship between aortic cross-clamping time and myocardial protection effects, patients studied were divided into the following 3 groups. I group: aortic cross-clamping time, 60 minutes, II group: aortic cross-clamping time, 90 minutes, III group: aortic cross-clamping time, over 91 minutes. 1. Changes in serum enzyme levels in postoperative period. [1] SCOT; The postoperative value [increased over 200 units] for ischemic myocardial injury during operation was observed in 11 cases [19.3% of the total] of the total patients studied, of which 4 cases [13.3%] in I group, 1 case [10.0%] in II group, and 6 cases [35.3%] in III group. [2] LDH; The positive value [increased over 900 units] for ischemic myocardial injury during operation was observed in 9 cases [15.7% of the total] of the total patients studied, of which 2 cases [6.6%] in I group, 1 case [10.0%] in II group, and 6 cases [35.3%] in III group. [3] CPK; The positive value [increased over 800 units] for ischemic myocardial injury during operation was observed in 10 cases [17. 5% of the total] of the total patients studied, including 4 cases [13. 3%] in I group, 1 case [10.0%] in II group, and 5 cases [29.4%] in III group. 2. The myocardial protection method used in the present study was demonstrated to be effective for the myocardial protection in the surgery with aortic cross-clamping time of up to 90 minutes. A few ischemic myocardial injury were observed in the surgery with aortic cross-clamping time over 91 minutes, but no significant cardiac dysfunction was noted. The surgery with aortic cross-clamping time of up to 191 minutes did not appear to give rise any significant interference with postoperative recovery.

  • PDF

Arterial Switch Operation for Transposition of G rest Arteries (대혈관전위증에 대한 동맥전환술)

  • 이호철;류한영
    • Journal of Chest Surgery
    • /
    • v.29 no.3
    • /
    • pp.278-284
    • /
    • 1996
  • Nine infants with transposition of great arteries have undergone arterial switch operation from May 1989 to May 1994 in the Department of Thoracic and Cardiovascular Surgery, Yeungnam University Hospital. Patients' age ranged from 3 days to 90 days, averaging 30$\pm$21 days. Diagnosis was made by two-dimensional echocardiography in all patients. Eight patients were diagnosed as transposition of great arteries with ventricular septal defect and one patient was a simple transposition of great arteries. Associated anomalies were patent ductus arteriosus (8), atrial septal defect (7) and coarctation of aorta(1). The anatomy of the coronary arteries were 7 (77 %) type A and 2 (23 %) type D according to the Yacoub classification. Pulmonary artery reconstruction was done according to Lecompte maneuver with tautologous pericardial patch in 8 patients. Overall operative mortality rate was 55% Left heart failure and pulmonary hypertensive crisis were the cause of death on postoperative 1~2 days in three patients, and two succumbed to death due to sepsis on postoperative 2~ 3 weeks. The mean follow-up period was mean 17 months. No patient had clinically significant postoperative aortic regurgitation and supravalvular pulmonary stenosis. The excessive use of inotropic support postoperatively was identified as a stastically significant risk factor following the arterial switch operation. But other variables such as low body weight, long cardiopulmonary bypass time, excessive hemodilution during cardiopulmonary bypass, hypothermia and volume loading were not significant risk factors.

  • PDF