• 제목/요약/키워드: Cardiac pacemaker, Artificial

검색결과 19건 처리시간 0.024초

Single-Chamber 페이스메이커 테스터의 개발에 관한 연구 (A Study on the Development of a Single-Chamber Cardiac Pacemaker Tester)

  • 강병윤;신재우;윤영로
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.119-120
    • /
    • 1998
  • In this study, the design of the single-chamber pacemaker tester is presented. It is important to test the functions of the pacemaker before it is implanted into the patient. A pacemaker tester, that is presented in this study, is able to examine pacemaker parameters such as sensing threshold and refractory period. We need to make artificial intracardiac electrogram in order to test the pacemaker parameters. We know from the previous practical examples that a triangle pulse is similar to the physiologic intracardiac electrogram. The tester generates the simplified electrograms and PC software examines the output pulses of the pacemaker which is VVIR mode in closed-loop simulation.

  • PDF

피지옴 모델을 이용한 심실의 전기활성시간 분포에 따른 심박출 성능평가 (Estimation of Cardiac Pumping Performance according to the Ventricular Electrical Activation Time Distribution by Using Physiome Model)

  • 김형균;임기무
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.198-203
    • /
    • 2015
  • The purpose of the study is to examine the effects of pacemaker location on cardiac pumping efficacy theoretically. We used a three-dimensional finite element cardiac electromechanical model of canine ventricles with models of the circulatory system. Electrical activation time for normal sinus rhythm and artificial pacing in apex, left ventricular free wall, and right ventricular free wall were obtained from electrophysiological model. We applied the electrical activation time maps to the mechanical contraction model and obtained cardiac mechanical responses such as myocardial contractile ATP consumption, stroke work, stroke volume, ejection fraction, and etc. Among three artificial pacing methods, left ventricle pacing showed best performance in ventricular pumping efficacy.

A Case Report of Rare Complications after Epicardial Permanent Pacemaker Implantation in an Infant: Airway Compression, Skin Necrosis, and Bowel Perforation

  • Kim, Woojung;Kwak, Jae Gun;Min, Jooncheol;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • 제53권2호
    • /
    • pp.82-85
    • /
    • 2020
  • Insertion of an epicardial pacemaker is a useful treatment for pediatric patients with an abnormal heart rhythm. However, there are limitations and concerns when implanting epicardial pacemakers in infants and neonates due to their small body size. We report a patient who experienced rare complications after implantation of a permanent pacemaker.

An Implantable Antenna for Wireless Body Area Network Application

  • Kim, Ui-Sheon;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.206-211
    • /
    • 2010
  • In this paper, an implantable planar inverted-F antenna (PIFA) for an artificial cardiac pacemaker is proposed. The antenna has a simple structure with a low profile and is placed on the top side of the pacemaker. The dimensions of the pacemaker system, including the antenna element, are $42{\times}43.6{\times}11$ mm. When the antenna is embedded in pig tissue, its $S_{11}$ value is -10.94 dB at 403 MHz and the -10 dB impedance bandwidth of the antenna is 6 MHz (399~406 MHz). The proposed PIFA in tissue has a peak gain of -20.19 dBi and a radiation efficiency of 1.12 % at 403 MHz. When the proposed antenna is placed in a flat phantom, its specific absorption ratio (SAR) value is 0.038 W/kg (1 g tissue). Performances of the proposed PIFA is sufficient to operate at the MICS band (402 ~ 405 MHz).

완전방실차단을 동반한 감염성 심내막염 환자에서 판막치환술 후 관정맥동을 통해 좌심실을 조율하는 심박조율기 시술 (Implantation of a permanent pacemaker through the coronary sinus in a patient who underwent mechanical valve replacement for infective endocarditis with a complete atrioventricular block)

  • 조관훈;김인호;안서희;오용석
    • Journal of Yeungnam Medical Science
    • /
    • 제31권2호
    • /
    • pp.113-116
    • /
    • 2014
  • A 52-year-old man was referred to our hospital due to fever and myalgia that occurred 2 weeks earlier. He showed a complete atrioventricular block on his electrocardiogram, and his vital signs were unstable. On his transthoracic echocardiograph, the 1.5 cm vegetation in the aortic valve with severe aortic regurgitation suggested infective endocarditis. His transesophageal enchocardiograph showed abscess in his mitral-aortic intervalvular fibrosa and vegetation was suspected on his anterior mitral valve leaflet. The patient underwent an emergent operation for valve replacement with temporary epicardial pacing. Intraoperatively, the septal leaflet of his tricuspid valve was injured during the debridement of the abscess pocket that was extended to the membranous septum. The aortic, mitral, and tricuspid mechanical valves were replaced with annular reconstruction without complications. After 14 days of intravenous antibiotics, we successfully changed the epicardial pacemaker into a transvenous DDD-type permanent pacemaker by placing a left ventricular lead via the coronary sinus and an atrial lead in the right atrium appendage. The patient was discharged in a tolerable state and was examined uneventfully in our hospital's outpatient clinic for 8 months.

Phospholipid Component 를 함유한 가교된 Polyurethane Biomaterials의 제조와 물성 (Preparation and properties of crosslinked polyurethane containing phospholipid component for biomaterials)

  • Yoo, Hye-Jin;Kim, Han-Do
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.55-58
    • /
    • 2003
  • Segmented polyurethanes have been widely used for various commercial and experimental blood-contacting and tissue-contacting applications such as vascular prostheses, blood pumps, heart valves, pacemaker lead wire insulation, catheters, artificial hearts, and cardiac assist devices due to their generally favorable physical and mechanical properties, as well as fairly good biocompatibility and antithrombogenicity characteristics. (omitted)

  • PDF

VVI 단극유도의 심박조율치를 가진 환자의 개심술 -1례 치험- (Cardiac Surgery for the Patient with VVI Unipolar Pacing System -One Case-)

  • 정해동;최종범;최형호
    • Journal of Chest Surgery
    • /
    • 제31권4호
    • /
    • pp.398-401
    • /
    • 1998
  • 단극유도의 심박조율기를 가진 56세 여자환자에서 관상동맥 우회로술과 승모판 치환술을 시행하였다. 이러한 단극유도 심박조율기는 심근 외의 전자기의 간섭에 대한 감수성이 높으므로 개심술시 전기소작기의 전기파에 의해 심박조율기의 조율기능이 억제될 수 있으며, 수술후 제세동기 사용할 때 영구 심박조율기에 전기 충격이 갈 수 있다. 따라서 대동맥 차단 감자를 해제한 후 심실세동없이 정상 심박동을 유도해야 한다. 본 환자에서 임시형 심방실 유도를 거치하고 임시형 심박조율기로 조율하여 심장리듬과 심기능을 유지시키면서 전기소작기를 사용할 수 있었으며, 대동맥 차단 중 전행성 및 역행성으로 혈성심정지액을 투여하고 대동맥 차단감자를 해제하기 직전에는 온혈심정지액과 온혈의 순차적인 역행성 주입으로 자연적인 심장리듬을 회복시킴으로써 제세동기 사용을 배제할 수 있었다.

  • PDF

어지럼증을 호소하는 서맥성 부정맥 환자의 한의복합치료 1례 (A Case of Patient with Brady-arrhythmia Complaining Dizziness Treated with complex Korean Medicine treatments)

  • 정소민;이성욱;하원정;조기호;문상관;정우상;권승원;이한결
    • 대한중풍순환신경학회지
    • /
    • 제23권1호
    • /
    • pp.41-54
    • /
    • 2022
  • Brady-arrhythmia is defined as an arrhythmia in which the heart rate slows to less than 60 beats per minute. Brady-arrhythmia reduces cardiac output and causes changes in blood flow. As a result, dizziness occurs because not only ischemia occurs in the central nervous system, but also blood flow in major organs decreases. The insertion of an artificial pacemaker is known as almost the only treatment alternative for patients with brady-arrhythmia with symptoms. This study reports a case of 85 year old male diagnosed with brady-arrhythmia complaining presyncope type of dizziness. The patient underwent complex Korean medicine treatments by herbal medicine, acupuncture and moxibustion. The daily average value of pulse rate, K-DHI score, NRS score and the patient's subjective expression of symptoms were used as evaluation tools. This study suggested a significant improvement in symptoms through complex Korean medicine treatments without the use of anti-arrhythmic drugs or insertion of an artificial pacemaker in the patient with brady-arrhythmia complaining dizziness.

Mitral Annulus Calcification and Cardiac Conduction Disturbances: A DANCAVAS Sub-study

  • Jeppe Holm Rasmussen;Maise Hoeigaard Fredgart;Jes Sanddal Lindholt;Jens Brock Johansen;Niels Sandgaard;Abdulrahman Haj Yousef;Selma Hasific;Pernille Sonderskov;Flemming Hald Steffensen;Lars Frost;Jess Lambrechtsen;Marek Karon;Martin Busk;Grazina Urbonaviciene;Kenneth Egstrup;Axel Cosmus Pyndt Diederichsen
    • Journal of Cardiovascular Imaging
    • /
    • 제30권1호
    • /
    • pp.62-75
    • /
    • 2022
  • BACKGROUND: Due to its location very close to the bundle of His, mitral annulus calcification (MAC) might be associated with the development of atrioventricular (AV) conduction disturbances. This study assessed the association between MAC and AV conduction disturbances identified by cardiac implantable electronic device (CIED) use and electrocardiographic parameters. The association between MAC and traditional cardiovascular risk factors was also assessed. METHODS: This cross-sectional study analyzed 14,771 participants, predominantly men aged 60-75 years, from the population-based Danish Cardiovascular Screening trial. Traditional cardiovascular risk factors were obtained. Using cardiac non-contrast computed tomography imaging, MAC scores were measured using the Agatston method and divided into absent versus present and score categories. CIED implantation data were obtained from the Danish Pacemaker and Implantable Cardioverter Defibrillator Register. A 12-lead electrocardiogram was available for 2,107 participants. Associations between MAC scores and AV conduction disturbances were assessed using multivariate regression analyses. RESULTS: MAC was present in 22.4% of the study subjects. Participants with pacemakers for an AV conduction disturbance had significantly higher MAC scores (odds ratio [OR], 1.11; 95% confidence interval [CI], 1.01-1.23) than participants without a CIED, whereas participants with a CIED for other reasons did not. Prolonged QRS-interval was significantly associated with the presence of MAC (OR, 1.45; 95% CI, 1.04-2.04), whereas prolonged PQ-interval was not. Female sex and most traditional cardiovascular risk factors were significantly associated with high MAC scores. CONCLUSIONS: MAC was associated with AV conduction disturbances, which could improve our understanding of the development of AV conduction disturbances.