• Title/Summary/Keyword: Cardiac magnetic resonance

Search Result 158, Processing Time 0.354 seconds

Regional Amyloid Burden Differences Evaluated Using Quantitative Cardiac MRI in Patients with Cardiac Amyloidosis

  • Jin Young Kim;Yoo Jin Hong;Kyunghwa Han;Hye-Jeong Lee;Jin Hur;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.880-889
    • /
    • 2021
  • Objective: This study aimed to investigate the regional amyloid burden and myocardial deformation using T1 mapping and strain values in patients with cardiac amyloidosis (CA) according to late gadolinium enhancement (LGE) patterns. Materials and Methods: Forty patients with CA were divided into 2 groups per LGE pattern, and 15 healthy subjects were enrolled. Global and regional native T1 and T2 mapping, extracellular volume (ECV), and cardiac magnetic resonance (CMR)-feature tracking strain values were compared in an intergroup and interregional manner. Results: Of the patients with CA, 32 had diffuse global LGE (group 2), and 8 had focal patchy or no LGE (group 1). Global native T1, T2, and ECV were significantly higher in groups 1 and 2 than in the control group (native T1: 1384.4 ms vs. 1466.8 ms vs. 1230.5 ms; T2: 53.8 ms vs. 54.2 ms vs. 48.9 ms; and ECV: 36.9% vs. 51.4% vs. 26.0%, respectively; all, p < 0.001). Basal ECV (53.7%) was significantly higher than the mid and apical ECVs (50.1% and 50.0%, respectively; p < 0.001) in group 2. Basal and mid peak radial strains (PRSs) and peak circumferential strains (PCSs) were significantly lower than the apical PRS and PCS, respectively (PRS, 15.6% vs. 16.7% vs. 26.9%; and PCS, -9.7% vs. -10.9% vs. -15.0%; all, p < 0.001). Basal ECV and basal strain (2-dimensional PRS) in group 2 showed a significant negative correlation (r = -0.623, p < 0.001). Group 1 showed no regional ECV differences (basal, 37.0%; mid, 35.9%; and apical, 38.3%; p = 0.184). Conclusion: Quantitative T1 mapping parameters such as native T1 and ECV may help diagnose early CA. ECV, in particular, can reflect regional differences in the amyloid deposition in patients with advanced CA, and increased basal ECV is related to decreased basal strain. Therefore, quantitative CMR parameters may help diagnose CA and determine its severity in patients with or without LGE.

Automated Measurement of Native T1 and Extracellular Volume Fraction in Cardiac Magnetic Resonance Imaging Using a Commercially Available Deep Learning Algorithm

  • Suyon Chang;Kyunghwa Han;Suji Lee;Young Joong Yang;Pan Ki Kim;Byoung Wook Choi;Young Joo Suh
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1251-1259
    • /
    • 2022
  • Objective: T1 mapping provides valuable information regarding cardiomyopathies. Manual drawing is time consuming and prone to subjective errors. Therefore, this study aimed to test a DL algorithm for the automated measurement of native T1 and extracellular volume (ECV) fractions in cardiac magnetic resonance (CMR) imaging with a temporally separated dataset. Materials and Methods: CMR images obtained for 95 participants (mean age ± standard deviation, 54.5 ± 15.2 years), including 36 left ventricular hypertrophy (12 hypertrophic cardiomyopathy, 12 Fabry disease, and 12 amyloidosis), 32 dilated cardiomyopathy, and 27 healthy volunteers, were included. A commercial deep learning (DL) algorithm based on 2D U-net (Myomics-T1 software, version 1.0.0) was used for the automated analysis of T1 maps. Four radiologists, as study readers, performed manual analysis. The reference standard was the consensus result of the manual analysis by two additional expert readers. The segmentation performance of the DL algorithm and the correlation and agreement between the automated measurement and the reference standard were assessed. Interobserver agreement among the four radiologists was analyzed. Results: DL successfully segmented the myocardium in 99.3% of slices in the native T1 map and 89.8% of slices in the post-T1 map with Dice similarity coefficients of 0.86 ± 0.05 and 0.74 ± 0.17, respectively. Native T1 and ECV showed strong correlation and agreement between DL and the reference: for T1, r = 0.967 (95% confidence interval [CI], 0.951-0.978) and bias of 9.5 msec (95% limits of agreement [LOA], -23.6-42.6 msec); for ECV, r = 0.987 (95% CI, 0.980-0.991) and bias of 0.7% (95% LOA, -2.8%-4.2%) on per-subject basis. Agreements between DL and each of the four radiologists were excellent (intraclass correlation coefficient [ICC] of 0.98-0.99 for both native T1 and ECV), comparable to the pairwise agreement between the radiologists (ICC of 0.97-1.00 and 0.99-1.00 for native T1 and ECV, respectively). Conclusion: The DL algorithm allowed automated T1 and ECV measurements comparable to those of radiologists.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Role of Myocardial Extracellular Volume Fraction Measured with Magnetic Resonance Imaging in the Prediction of Left Ventricular Functional Outcome after Revascularization of Chronic Total Occlusion of Coronary Arteries

  • Yinyin Chen;Xinde Zheng;Hang Jin;Shengming Deng;Daoyuan Ren;Andreas Greiser;Caixia Fu;Hongxiang Gao;Mengsu Zeng
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.83-93
    • /
    • 2019
  • Objective: The purpose of this study was to prospectively investigate the value of the myocardial extracellular volume fraction (ECV) in predicting myocardial functional outcome after revascularization of coronary chronic total occlusion (CTO). Materials and Methods: Thirty patients with CTO underwent cardiovascular magnetic resonance (CMR) before and 6 months after revascularization. Three baseline markers of functional outcome were evaluated in the dysfunctional segments assigned to the CTO vessels: ECV, transmural extent of infarction (TEI), and unenhanced rim thickness (RIM). At the global level, the ECV values of the whole myocardium with and without a hyperenhanced region (global and remote ECV) were respectively measured. Results: In per-segment analysis, ECV was superior to TEI and RIM in predicting functional recovery (area under receiver operating characteristic curve [AUC]: 0.86 vs. 0.75 and 0.73, all p values < 0.010), and it emerged as the only independent predictor of regional functional outcome (odds ratio [OR] = 0.83, 95% confidence interval [CI]: 0.77-0.89; p < 0.001) independent of collateral circulation. In per-patient analysis, global baseline ECV was indicative of ejection fraction (EF) at the follow-up examination (β = -0.61, p < 0.001) and changes in EF (β = -0.57, p = 0.001) in multivariate regression analysis. A patient with global baseline ECV less than 30.0% (AUC, 0.93; sensitivity 94%, specificity 80%) was more likely to demonstrate significant EF improvement (OR: 0.38; 95% CI: 0.17-0.85; p = 0.019). Conclusion: Extracellular volume fraction obtained by CMR may provide incremental value for the prediction of functional recovery both at the segmental and global levels in CTO patients, and may facilitate the identification of patients who can benefit from revascularization.

Prognostic Implication of Right Ventricle Parameters Measured on Preoperative Cardiac MRI in Patients with Functional Tricuspid Regurgitation

  • Yura Ahn;Hyun Jung Koo;Joon-Won Kang;Won Jin Choi;Dae-Hee Kim;Jong-Min Song;Duk-Hyun Kang;Jae-Kwan Song;Joon Bum Kim;Sung-Ho Jung;Suk Jung Choo;Cheol Hyun Chung;Jae Won Lee;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1253-1265
    • /
    • 2021
  • Objective: To investigate the prognostic value of preoperative cardiac magnetic resonance imaging (MRI) for long-term major adverse cardiac and cerebrovascular events (MACCEs) in patients undergoing tricuspid valve (TV) surgery for functional tricuspid regurgitation (TR). Materials and Methods: The preoperative cardiac MR images, New York Heart Association functional class, comorbidities, and clinical events of 78 patients (median [interquartile range], 59 [51-66.3] years, 28.2% male) who underwent TV surgery for functional TR were comprehensively reviewed. Cox proportional hazards analyses were performed to assess the associations of clinical and imaging parameters with MACCEs and all-cause mortality. Results: For the median follow-up duration of 5.4 years (interquartile range, 1.2-6.6), MACCEs and all-cause mortality were 51.3% and 23.1%, respectively. The right ventricular (RV) end-systolic volume index (ESVI) and the systolic RV mass index (RVMI) were higher in patients with MACCEs than those without them (77 vs. 68 mL/m2, p = 0.048; 23.5 vs. 18.0%, p = 0.011, respectively). A high RV ESVI was associated with all-cause mortality (hazard ratio [HR] per value of 10 higher ESVI = 1.10, p = 0.03). A high RVMI was also associated with all-cause mortality (HR per increase of 5 mL/m2 RVMI = 1.75, p < 0.001). After adjusting for age and sex, only RVMI remained a significant predictor of MACCEs and all-cause mortality (p < 0.05 for both). After adjusting for multiple clinical variables, RVMI remained significantly associated with all-cause mortality (p = 0.005). Conclusion: RVMI measured on preoperative cardiac MRI was an independent predictor of long-term outcomes in patients who underwent TV surgery for functional TR.

Evaluation of Left Atrial Appendage Isolation Using Cardiac MRI after Catheter Ablation of Atrial Fibrillation: Paradox of Appendage Reservoir

  • Hyungjoon Cho;Yongwon Cho;Jaemin Shim;Jong-il Choi;Young-Hoon Kim;Yu-Whan Oh;Sung Ho Hwang
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.525-534
    • /
    • 2021
  • Objective: To assess the effect of left atrial appendage (LAA) isolation on LAA emptying and left atrial (LA) function using cardiac MRI in patients who underwent successful catheter ablation of atrial fibrillation (AF). Materials and Methods: This retrospective study included 84 patients (mean age, 59 ± 10 years; 67 males) who underwent cardiac MRI after successful catheter ablation of AF. According to the electrical activity of LAA after catheter ablation, patients showed either LAA isolation or LAA normal activity. The LAA emptying phase (LAA-EP, in the systolic phase [SP] or diastolic phase), LAA emptying flux (LAA-EF, mL/s), and LA ejection fraction (LAEF, %) were evaluated by cardiac MRI. Results: Of the 84 patients, 61 (73%) and 23 (27%) patients showed LAA normal activity and LAA isolation, respectively. Incidence of LAA emptying in SP was significantly higher in LAA isolation (91% vs. 0%, p < 0.001) than in LAA normal activation. LAA-EF was significantly lower in LAA isolation (40.1 ± 16.2 mL/s vs. 80.2 ± 25.1 mL/s, p < 0.001) than in LAA normal activity. Furthermore, LAEF was significantly lower in LAA isolation (23.7% ± 11.2% vs. 31.1% ± 16.6%, p = 0.04) than in LAA normal activity. Multivariate analysis demonstrated that the LAA-EP was independent from LAEF (p = 0.01). Conclusion: LAA emptying in SP may be a critical characteristic of LAA isolation, and it may adversely affect the LAEF after catheter ablation of AF.

Scan Time Analysis Using 4D Phase-Contrast MRI According to Scan Parameter: A Phantom Study (스캔 인자에 따른 4D 위상 대조 자기공명영상을 이용한 스캔 시간 분석: 팬텀 연구)

  • Park, Jieun;Kim, Junghun;Hwang, Moonjung;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.179-184
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect according to the NEX, VENC, targeted cardiac phases on the velocity measurement of 4D phase-contrast MRI. Materials and Methods: The abdominal aortic phantom was made to experiment. The working fluid was mixed with water and glycerin to mimic the density and viscosity of human blood. The inlet velocity was Reynolds number 2000. The experimental conditions were NEX 1 and 4, VENC 102 cm/s and 200 cm/s, and 10 and 15 targeted cardiac phases, respectively. The average flow rate, average velocity, maximum velocity, and cross-section area were measured. Results: As a result of the case-by-case comparison, the error rate was less than 5%. There was no significant difference (p > 0.05). Conclusion: It is expected that this result will be useful for acquiring blood flow information in clinical practice.

Minimizing MR Gradient Artefacts on ECG Signals for Cardiac Gating based on an Adaptive Digital Filter (적응 디지털 필터 기반의 MRI Cardiac Gating을 위한 심전도 신호의 MR Gradient 잡음 최소화 방법)

  • Park, Ho-Dong;Jang, Bong-Ryeol;Lee, Kyoung-Joung
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.817-818
    • /
    • 2006
  • In Magnetic Resonance Imaging(MRI), the QRS complex of ECG is used as a trigger signal for MRI scan. But, gradient and RF(radio frequency) artifacts which are caused to static and dynamic field in MRI scanner cause interference in the ECG. Also, the signal shape of theses artifacts can be similar to the QRS-complex, causing possible misinterpretation during patient monitoring and false gating of the MRI. In case of using general FIR or IIR band-pass filters for minimizing the artifacts, artifact-reduction-ratio is not excellent. So, an adaptive real-time digital filter is proposed for reduction of noise by gradient and RF(radio frequency) artifacts. The proposed filter for MRI-Gating is based on the noise-canceller with NLMS(Normalized Least Mean Square) algorithm. The reference signals of the adaptive noise canceller are a combination of the noisy three channel ECG signals. In conclusions, the proposed method showed the acceptable quality of ECG signal with sufficient SNR for gating the MRI and possibility of real time implementation.

  • PDF

Cardiac arrest and severe encephalopathy following e-cigarette nicotine intoxication: a case report (심정지 및 심각한 뇌병변 장애를 초래한 전자 담배용 Nicotine 중독 1례)

  • Jinwon Park;Sunghyun Yun
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.20 no.2
    • /
    • pp.82-85
    • /
    • 2022
  • Traditionally, most cases of nicotine poisoning have been due to ingestion of nicotine pesticides. However, the increasing use of electronic cigarettes (e-cigarettes) has resulted in both intentional and unintentional exposure to concentrated liquid nicotine or "e-liquid" leading to an increase in nicotine poisoning cases. However, fatalities following the ingestion of the e-liquid are extremely rare. We report a rare case of cardiac arrest and severe encephalopathy following the intentional ingestion of e-liquid. We present the case of a 20-year-old woman who intentionally ingested liquid nicotine intended for e-cigarette use. She was found in asystole and experienced a return of spontaneous circulation (ROSC) after undergoing approximately 46 mins of cardiopulmonary resuscitation. Her plasma nicotine levels were >500 ng/ml. Despite aggressive supportive care, she was found to have encephalopathy consistent with severe anoxic brain injury on magnetic resonance imaging. In recent times, there have been some reports of deaths following liquid nicotine ingestion. Our case illustrates the potential for fatal nicotine toxicity from ingestion of e-cigarettes.

A Rare Case of Cardiac Neurofibroma in a Patient with Neurofibromatosis Type 1: Radiologic Findings (신경섬유종증 1형 환자에서 드물게 발생하는 심장 신경섬유종: 영상의학적 소견)

  • Sanghyun Seo;Ji Young Rho
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1321-1327
    • /
    • 2021
  • Neurofibromatosis type 1 (NF1) is a relatively common inherited disorder characterized by the formation of neurofibromas, pigmentary abnormalities of the skin, Lisch nodules of the iris, and skeletal abnormalities. Multiple cutaneous neurofibromas are benign nerve sheath tumors and the main manifestation of NF1. Cardiac neurofibroma associated with NF1 is very rare, and few cases have been reported in the literature. Herein, we present the CT and MRI findings of a surgically confirmed left ventricular neurofibroma in a 32-year-old female with NF1.