• Title/Summary/Keyword: Cardiac CT

Search Result 155, Processing Time 0.024 seconds

A Rare Case of Cardiac Neurofibroma in a Patient with Neurofibromatosis Type 1: Radiologic Findings (신경섬유종증 1형 환자에서 드물게 발생하는 심장 신경섬유종: 영상의학적 소견)

  • Sanghyun Seo;Ji Young Rho
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1321-1327
    • /
    • 2021
  • Neurofibromatosis type 1 (NF1) is a relatively common inherited disorder characterized by the formation of neurofibromas, pigmentary abnormalities of the skin, Lisch nodules of the iris, and skeletal abnormalities. Multiple cutaneous neurofibromas are benign nerve sheath tumors and the main manifestation of NF1. Cardiac neurofibroma associated with NF1 is very rare, and few cases have been reported in the literature. Herein, we present the CT and MRI findings of a surgically confirmed left ventricular neurofibroma in a 32-year-old female with NF1.

Feasibility and Safety of a Technique Intended to Place the Catheter Tip in the Right Atrium without Abutment Against the Cardiac Wall during Implantation of the Totally Implantable Venous Access Port (완전이식형 정맥 접근 포트 삽입 시 카테터 팁을 심벽에 닿지 않고 우심방 내 위치시키는 방법의 타당성과 안전성)

  • Hyejin Park;Tae-Seok Seo;Myung Gyu Song;Woo Jin Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.161-170
    • /
    • 2024
  • Purpose To assess the safety and feasibility of intentionally positioning the catheter tip in the right atrium (RA) without an abutment during implantation of a totally implantable venous access port (TIVAP). Materials and Methods We enrolled 330 patients who had undergone TIVAP implantation between January and December 2016 and postoperative chest CT. The TIVAP was placed using the single-incision technique to access the axillary vein directly from the incision line. To position the catheter tip in the RA without abutment, blood return was checked before cutting. Catheter length and complications were evaluated by retrospectively reviewing medical images and records. Results All patients achieved successful catheter tip positioning without abutment or dysfunction. The median tip position was 15.3 mm distal to the cavoatrial junction (CAJ) on fluoroscopy and 6 mm distal to the CAJ on CT. Catheter tips migrated a median of 10.4 mm cephalically on CT compared to fluoroscopy. Thromboses were detected in the RA and superior vena cava in one patient each. Conclusion Intentional catheter tip positioning in the RA without abutment is a safe and feasible technique with a low incidence of thrombosis and no observed dysfunction.

Correlation Between Pulmonary Contusion and Myocardial Contusion in Patients with Multiple Injuries (다발성 외상환자에서 폐좌상과 심근좌상의 상관관계)

  • Ryu, Ji-Ho;Yeom, Seok-Ran;Jeong, Jin-Woo;Min, Mun-Ki;Park, Maeng-Real;Kim, Yong-In;Han, Sang-Kyun;Park, Sung-Wook
    • Journal of Trauma and Injury
    • /
    • v.24 no.1
    • /
    • pp.31-36
    • /
    • 2011
  • Purpose: This study was conducted to evaluate the correlations among pulmonary contusion severity, trauma score and cardiac troponin I (cTnI) level. Methods: We prospectively evaluated patients with multiple injuries who had been admitted to the emergency department (ED) from July 2007 to July 2008. We first measured the total creatinine kinase (CK), the MB fraction of CK (CK-MB), TnI, and myoglobin within 2 hours after the injury. We then checked the electrocardiogram, x-ray, and computed tomography (CT) results. Finally, we assessed the injuries as variables and then compared the results for patients with elevated TnI levels (group A) and patients whose TnI levels fell within the normal range (group B). Results: Eighty-six of the 92 patients admitted to the ED were enrolled. The pulmonary contusion score (PCS) was well correlated with $PaO_2/FiO_2$. TnI levels were correlated with PCS. When TnI levels were above 0.86 ng/ml, the mortality was estimated with 100% sensitivity and 86.1% specificity. Conclusion: Pulmonary contusion severity is correlated with TnI level. When the PCS is high and the cTnI level is elevated in multiple-injury patients, we recommend continuous cardiac monitoring and further evaluation

Automated Segmentation of Left Ventricular Myocardium on Cardiac Computed Tomography Using Deep Learning

  • Hyun Jung Koo;June-Goo Lee;Ji Yeon Ko;Gaeun Lee;Joon-Won Kang;Young-Hak Kim;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.660-669
    • /
    • 2020
  • Objective: To evaluate the accuracy of a deep learning-based automated segmentation of the left ventricle (LV) myocardium using cardiac CT. Materials and Methods: To develop a fully automated algorithm, 100 subjects with coronary artery disease were randomly selected as a development set (50 training / 20 validation / 30 internal test). An experienced cardiac radiologist generated the manual segmentation of the development set. The trained model was evaluated using 1000 validation set generated by an experienced technician. Visual assessment was performed to compare the manual and automatic segmentations. In a quantitative analysis, sensitivity and specificity were calculated according to the number of pixels where two three-dimensional masks of the manual and deep learning segmentations overlapped. Similarity indices, such as the Dice similarity coefficient (DSC), were used to evaluate the margin of each segmented masks. Results: The sensitivity and specificity of automated segmentation for each segment (1-16 segments) were high (85.5-100.0%). The DSC was 88.3 ± 6.2%. Among randomly selected 100 cases, all manual segmentation and deep learning masks for visual analysis were classified as very accurate to mostly accurate and there were no inaccurate cases (manual vs. deep learning: very accurate, 31 vs. 53; accurate, 64 vs. 39; mostly accurate, 15 vs. 8). The number of very accurate cases for deep learning masks was greater than that for manually segmented masks. Conclusion: We present deep learning-based automatic segmentation of the LV myocardium and the results are comparable to manual segmentation data with high sensitivity, specificity, and high similarity scores.

Use of Coronary CT Angiography as a Screening Tool for Coronary Artery Disease in Asymptomatic Healthy Individuals or Patients (무증상 정상인 또는 환자의 관상동맥 질환 선별 검사로서 관상동맥 전산화단층촬영 혈관조영술의 유용성)

  • Gong Yong Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.54-69
    • /
    • 2022
  • Early detection of potential asymptomatic coronary artery disease is very important, as patients with sudden cardiac death often do not show symptoms such as chest pain or motor dyspnea. Coronary CT angiography (CCTA) has long been unjustified as a screening tool for asymptomatic patients because of the risks posed by radiation exposure. However, there are still various opinions regarding the usefulness of CCTA for screening for coronary artery disease (CAD) in asymptomatic healthy individuals or patients. This review investigated the usefulness of coronary artery calcium score and CCTA as screening tests for CAD in asymptomatic healthy individuals or patients through various literature reviews. With the development of CT technology, recent studies have been conducted in asymptomatic CAD patients with a reduced radiation dose of less than 1 mSv. A total of 2.6% of asymptomatic subjects on CCTA found significant CAD over 70%, and it was concluded that screening CCTA for CAD showed prognostic power in predicting the future occurrence of CAD in asymptomatic people. However, after the completion of the current NIH SCOT-HEART 2 study, it may be possible to determine whether CCTA is appropriate as a screening tool for CAD in asymptomatic healthy individuals.

Removal of Bone Cement through Right Anterolateral Thoracotomy

  • Chung, Jin-Woo;Shin, Je-Kyoun;Chee, Hyun-Keun;Kim, Jun-Seok;Kim, Dong-Chan;Park, Jae-Bum
    • Journal of Chest Surgery
    • /
    • v.45 no.3
    • /
    • pp.202-204
    • /
    • 2012
  • A 55-year-old woman who had a history of percutaneous vertebroplasty was referred to our institution with sudden onset of chest pain. Computed tomography (CT) scan demonstrated a long, linear, highly-attenuated segment in the right side of the heart and fragmented pieces in the right pulmonary artery. The CT scan and echocardiogram revealed no pericardial effusion or hemopericardium. Based on these findings, we performed surgery through right anterolateral thoracotomy without cardiac arrest. As a result, we safely removed the foreign body. This approach may be a feasible and effective procedure for selected cases.

Non-occlusive Mesenteric Ischemia (NOMI) Secondary to Traumatic Hemorrhagic Shock: Case Report (외상성 출혈성 쇼크 환자에서 발생한 비 폐쇄성 장간막 허혈)

  • Lim, Kyoung Hoon;Jung, Hee Kyung;Cho, Jayun;Lee, Sang Cjeol;Park, Jinyoung
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.204-207
    • /
    • 2014
  • Non-occlusive mesenteric ischemia (NOMI) encompasses all forms of mesenteric ischemia with patent mesenteric arteries. NOMI is commonly caused by decreased cardiac output resulting in hypoperfusion of peripheral mesenteric arteries. We report a case of NOMI secondary to hemorrhagic shock and rhabdomyolysis due to trauma. A 42-year-old man presented to our trauma center following a pedestrian trauma. On arrival, he was drowsy and in a state of hemorrhagic shock. He was found to have multiple fractures, both lung contusion and urethral rupture. An initial physical examination and abdominal computed tomography (CT) scan revealed no evidence of intra-abdominal injury. High doses of catecholamine were administered for initial 3 days due to unstable vital sign. On day 25 of hospitalization, follow-up abdominal CT scan demonstrated that short segment of small bowel loop was dilated and bowel wall was not enhanced. During exploratory laparotomy, necrosis of the terminal ileum with intact mesentery was detected and ileocecectomy was performed. His postoperative course was uneventful and is under rehabilitation.

The Study on Electrocardiographic Changes after Mitral Valvular Replacement (승모판막 수술에 따른 심전도 변화)

  • Yeo, Seung-Dong;Im, Seung-Pyeong
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.421-427
    • /
    • 1991
  • Atrial fibrillation[Af] is closely related to thrombus in left atrium, systemic embolism, and loss of the contribution of atrial contraction to cardiac output. Therefore maintenance of sinus rhythm[SR] is undoubtedly hemodynamically superior to Af in the clinical course of mitral valvular disease especially in the unstable period immediately after surgery. In this article, the conversion rate and the factors influencing the conversion of Af to SR after surgery were studied. Ninety-three patients with mitral valvular replacement at Chungnam National University Hospital were analysed with electrocardiography before and after surgery during the period from June 1985 to June 1990. Eighty patients presented Af before surgery. Twenty-four[30Yo] of the patients were converted to SR[A group] and fifty six presented continuous Af after surgery[B group]. The duration of preoperative Af, preoperative left atrial dimension[LAD], preoperative functional status[NYHA classification] and cardiothoracic[CT] ratio were factors influencing the conversion of Af to SR after surgery. The mean preoperative duration of Af was 3.5$\pm$2.6yr in group A and 7.6$\pm$4.9yr in group B. The mean preoperative LAD was 53. 7$\pm$9.4mm in group A and 62.5$\pm$11.2mm in group B. Before surgery, eleven patients[46%] were belong to NYHA class I, II in group A and eight[14%] in group B. The preoperative CT ratio was 62$\pm$6% in group A and 69$\pm$8% in group B.

  • PDF

Usability Evaluation of Lateral Sliding Table in CT Examination (CT 검사에서 Lateral Sliding Table의 유용성 평가)

  • Choi, Jeong Hun;Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.677-684
    • /
    • 2020
  • Miscentering in the left and right X axis direction during CT examination affects dose and quality. When the CT Gantry Isocenter and the center of the examination objective are matched using the Lateral Sliding Table, the image quality is improved and the exposure dose is reduced. CTDI Head Phantom (Kimda, Korea) and dosimeter (Ray Safe, Sweden) were used to measure dose comparison CTDI (mGy) due to center deviation, and Water Phantom (HITACHI, Japan) was used to measure noise to see the difference in uniformity due to center deviation. Measurements of doses for dose comparison CTDI (mGy) with a deviation showed that doses were consistently reduced and exact dose was not projected until they were moved to 80 mm by 20 mm from the Isocenter. SD values were measured to see the difference in uniformity due to center deviation and the noise continued to increase until it was moved by 20 mm to 80 mm. The range of collimation has increased by the extent of deviating from the center and the range of exposure has increased. Using the Lateral Sliding Table, you can easily adjust the Isocenter, increase the quality of the image by adjusting the Isocenter in areaa such as the cardiac examination of the location away from the Isocenter, Extreme bone and Shoulder, and greatly reduce the collimation to the Isocenter, so it can be used to reduce unnecessary exposure dose.

Fast Marker-based Registration of 3D CT and 2D X-ray Fluoroscopy Images (3차원 전산화 단층촬영영상과 2차원 X-선 투시영상간 표식기 기반 고속 정합)

  • Kim Gye-Hyun;Park Seong-Jin;Hong He-Len;Shin Yeong-Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.3
    • /
    • pp.335-343
    • /
    • 2006
  • This paper proposes a novel technique of marker-based 2D-3D registration to combine 3D information obtained from preoperative CT images into 2D image obtained from intraoperative x-ray fluoroscopy image. Our method is divided into preoperative and intraoperative procedures. In preoperative procedure, we generate CT-derived DRRs using graphics hardware and detect markers automatically. In intraoperative procedure, we propose a hierarchical two- step registration to reduce a degree of freedom from 6-DOP to 2-DOF which is composed of in-plane registration using principal axis method and out-plane registration using minimal error searching method in spherical coordinate. For experimentation, we use cardiac phantom datasets with confirmation markers and evaluate our method in the aspects of visual inspection, accuracy and processing time. As experimental results, our method keeps accuracy and aligns very fast by reducing real-time computations.