• Title/Summary/Keyword: Carbon monoxide

Search Result 1,001, Processing Time 0.024 seconds

A Study on the Characteristics of a Pt/TiO2 Catalyst Prepared by Liquid-Phase Ruduction for Formaldehyde Oxidation at Room Temperature (액상환원 기반 Pt/TiO2 촉매 제조를 이용한 포름알데히드 상온 산화 반응 특성 연구)

  • Jae Heon Kim;Younghee Jang;Geo Jong Kim;Sung Chul Kim;Sung Su Kim
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.612-618
    • /
    • 2023
  • Modern society spends more than 80% of its daily life indoors, emphasizing the need for attention to indoor air pollution due to the improvement in living standards. In this study, the performance and reaction characteristics of the Pt/TiO2 catalysts prepared by liquid-phase reduction for the removal of formaldehyde (HCHO), one of the indoor air pollutants, at room temperature without the need for additional light or heat were investigated. As a result, it showed that catalysts prepared by the same method showed approximately 40~80% various activities depending on the type of TiO2. XRD, BET, and XPS analyses were performed to investigate the particle size, crystal structure, specific surface area, and O/Ti molar ratio of the support material, and it revealed that the correlation between the properties and performance was insignificant. To explore the oxidation reaction pathway of formaldehyde (HCHO), in situ DRIFT analysis using carbon monoxide and H2-TPR was perfomed. The results revealed that the performance was demonstrated by the oxidation state of the active metal and the adsorption-desorption characteristics of the adsorbate species.

New Method for Combined Quantitative Assessment of Air-Trapping and Emphysema on Chest Computed Tomography in Chronic Obstructive Pulmonary Disease: Comparison with Parametric Response Mapping

  • Hye Jeon Hwang;Joon Beom Seo;Sang Min Lee;Namkug Kim;Jaeyoun Yi;Jae Seung Lee;Sei Won Lee;Yeon-Mok Oh;Sang-Do Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1719-1729
    • /
    • 2021
  • Objective: Emphysema and small-airway disease are the two major components of chronic obstructive pulmonary disease (COPD). We propose a novel method of quantitative computed tomography (CT) emphysema air-trapping composite (EAtC) mapping to assess each COPD component. We analyzed the potential use of this method for assessing lung function in patients with COPD. Materials and Methods: A total of 584 patients with COPD underwent inspiration and expiration CTs. Using pairwise analysis of inspiration and expiration CTs with non-rigid registration, EAtC mapping classified lung parenchyma into three areas: Normal, functional air trapping (fAT), and emphysema (Emph). We defined fAT as the area with a density change of less than 60 Hounsfield units (HU) between inspiration and expiration CTs among areas with a density less than -856 HU on inspiration CT. The volume fraction of each area was compared with clinical parameters and pulmonary function tests (PFTs). The results were compared with those of parametric response mapping (PRM) analysis. Results: The relative volumes of the EAtC classes differed according to the Global Initiative for Chronic Obstructive Lung Disease stages (p < 0.001). Each class showed moderate correlations with forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity (FVC) (r = -0.659-0.674, p < 0.001). Both fAT and Emph were significant predictors of FEV1 and FEV1/FVC (R2 = 0.352 and 0.488, respectively; p < 0.001). fAT was a significant predictor of mean forced expiratory flow between 25% and 75% and residual volume/total vital capacity (R2 = 0.264 and 0.233, respectively; p < 0.001), while Emph and age were significant predictors of carbon monoxide diffusing capacity (R2 = 0.303; p < 0.001). fAT showed better correlations with PFTs than with small-airway disease on PRM. Conclusion: The proposed quantitative CT EAtC mapping provides comprehensive lung functional information on each disease component of COPD, which may serve as an imaging biomarker of lung function.

Factors Associated with the Discrepancy between Exercise Capacity and Airflow Limitation in Patients with Chronic Obstructive Pulmonary Disease

  • Tae Hoon Kim;I Re Heo;Na Young Kim;Joo Hun Park;Hee-Young Yoon;Ji Ye Jung;Seung Won Ra;Ki-Suck Jung;Kwang Ha Yoo;Ho Cheol Kim
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.2
    • /
    • pp.155-164
    • /
    • 2024
  • Background: Exercise capacity is associated with lung function decline in chronic obstructive pulmonary disease (COPD) patients, but a discrepancy between exercise capacity and airflow limitation exists. This study aimed to explore factors contributing to this discrepancy in COPD patients. Methods: Data for this prospective study were obtained from the Korean COPD Subgroup Study. The exercise capacity and airflow limitation were assessed using the 6-minute walk distance (6-MWD; m) and forced expiratory volume in 1 second (FEV1). Participants were divided into four groups: FEV1 >50%+6-MWD >350, FEV1 >50%+6-MWD ≤350, FEV1 ≤50%+6-MWD >350, and FEV1 ≤50%+6-MWD ≤350 and their clinical characteristics were compared. Results: A total of 883 patients (male:female, 822:61; mean age, 68.3±7.97 years) were enrolled. Among 591 patients with FEV1 >50%, 242 were in the 6-MWD ≤350 group, and among 292 patients with FEV1 ≤50%, 185 were in the 6-MWD >350 group. The multiple regression analyses revealed that male sex (odds ratio [OR], 8.779; 95% confidence interval [CI], 1.539 to 50.087; p=0.014), current smoking status (OR, 0.355; 95% CI, 0.178 to 0.709; p=0.003), and hemoglobin levels (OR, 1.332; 95% CI, 1.077 to 1.648; p=0.008) were significantly associated with discrepancies in exercise capacity and airflow limitation in patients with FEV1 >50%. Meanwhile, in patients with FEV1 ≤50%, diffusion capacity of carbon monoxide (OR, 0.945; 95% CI, 0.912 to 0.979; p=0.002) was significantly associated with discrepancies between exercise capacity and airflow limitation. Conclusion: The exercise capacity of COPD patients may be influenced by factors other than airflow limitation, so these aspects should be considered when assessing and treating patients.

Measurement and analysis of tractor emission during plow tillage operation

  • Jun-Ho Lee;Hyeon-Ho Jeon;Seung-Min Baek;Seung-Yun Baek;Wan-Soo Kim;Yong-Joo Kim;Ryu-Gap Lim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.3
    • /
    • pp.383-394
    • /
    • 2023
  • In Korea, the U.S. Tier-4 Final emission standards have been applied to agricultural machinery since 2015. This study was conducted to analyze the emission characteristics of agricultural tractors during plow tillage operations using PEMS (portable emissions measurement systems). The tractor working speed was set as M2 (5.95 km/h) and M3 (7.60 km/h), which was the most used gear stage during plow tillage operation. An engine idling test was conducted before the plow tillage operation was conducted because the level of emissions differed depending on the temperature of the engine (cold and hot states). The estimated level of emissions for the regular area (660 m2), which was the typical area of cultivation, was based on an implement width of 2.15 m and distance from the work area of 2.2 m. As a result, average emission of CO (carbon monoxide), THC (total hydrocarbons), NOx (nitric oxides), and PM (particulate matter) were approximately 6.17×10-2, 3.36×10-4, 2.01×10-4, and 6.85×10-6 g/s, respectively. Based on the regular area, the total emission of CO, THC, NOx, and PM was 2.62, 3.76×10-2, 1.63, and 2.59×10-4 g, respectively. The results of total emission during plow tillage were compared to Tier 4 emission regulation limits. Tier 4 emission regulation limits means maximum value of the emission per consumption power (g/kWh), calculated as ratio of the emission and consumption power. Therefore, the total emission was converted to the emission per power using the rated power of the tractor. The emission per power was found to be satisfied below Tier 4 emission regulation limits for each emission gas. It is necessary to measure data by applying various test modes in the future and utilize them to calculate emission because the emission depends on various variables such as measurement environment and test mode.

Operating Optimization and Economic Evaluation of Multicomponent Gas Separation Process using Pressure Swing Adsorption and Membrane Process (압력 순환 흡착과 막 분리공정을 이용한 다성분 기체의 분리공정 조업 최적화 및 경제성 평가)

  • Kim, Hansol;Lee, Jaewook;Lee, Soobin;Han, Jeehoon;Lee, In-Beum
    • Korean Chemical Engineering Research
    • /
    • v.53 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • At present, carbon dioxide ($CO_2$) emission, which causes global warming, is a major issue all over the world. To reduce $CO_2$ emission directly, commercial deployment of $CO_2$ separation processes has been attempted in industrial plants, such as power plant, oil refinery and steelmaking plant. Besides, several studies have been done on indirect reduction of $CO_2$ emission from recycle of reducing gas (carbon monoxide or hydrogen containing gas) in the plants. Unlike many competing gas separation technologies, pressure swing adsorption (PSA) and membrane filtration are commercially used together or individually to separate a single component from the gas mixture. However, there are few studies on operation of sequential separation process of multi-component gas which has more than two target gas products. In this paper, process simulation model is first developed for two available configurations: $CO_2$ PSA-CO PSA-$H_2$ PSA and $CO_2$ PSA-CO PSA-$H_2$ membrane. Operation optimization and economic evaluation of the processes are also performed. As a result, feed gas contains about 14% of $H_2$ should be used as fuel than separating $H_2$, and $CO_2$ separation should be separated earlier than CO separation when feed gas contains about 30% of $CO_2$ and CO. The simulation results can help us to find an optimal process configuration and operation condition for separation of multicomponent gas with $CO_2$, CO, $H_2$ and other gases.

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

Optimization of DME Reforming using Steam Plasma (수증기 플라즈마를 이용한 DME 개질의 최적화 방안 연구)

  • Jung, Kyeongsoo;Chae, U-Ri;Chae, Ho Keun;Chung, Myeong-Sug;Lee, Joo-Yeoun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.5
    • /
    • pp.9-16
    • /
    • 2019
  • In today's global energy market, the importance of green energy is emerging. Hydrogen energy is the future clean energy source and one of the pollution-free energy sources. In particular, the fuel cell method using hydrogen enhances the flexibility of renewable energy and enables energy storage and conversion for a long time. Therefore, it is considered to be a solution that can solve environmental problems caused by the use of fossil resources and energy problems caused by exhaustion of resources simultaneously. The purpose of this study is to efficiently produce hydrogen using plasma, and to study the optimization of DME reforming by checking the reforming reaction and yield according to temperature. The research method uses a 2.45 GHz electromagnetic plasma torch to produce hydrogen by reforming DME(Di Methyl Ether), a clean fuel. Gasification analysis was performed under low temperature conditions ($T3=1100^{\circ}C$), low temperature peroxygen conditions ($T3=1100^{\circ}C$), and high temperature conditions ($T3=1376^{\circ}C$). The low temperature gasification analysis showed that methane is generated due to unstable reforming reaction near $1100^{\circ}C$. The low temperature peroxygen gasification analysis showed less hydrogen but more carbon dioxide than the low temperature gasification analysis. Gasification analysis at high temperature indicated that methane was generated from about $1150^{\circ}C$, but it was not generated above $1200^{\circ}C$. In conclusion, the higher the temperature during the reforming reaction, the higher the proportion of hydrogen, but the higher the proportion of CO. However, it was confirmed that the problem of heat loss and reforming occurred due to the structural problem of the gasifier. In future developments, there is a need to reduce incomplete combustion by improving gasifiers to obtain high yields of hydrogen and to reduce the generation of gases such as carbon monoxide and methane. The optimization plan to produce hydrogen by steam plasma reforming of DME proposed in this study is expected to make a meaningful contribution to producing eco-friendly and renewable energy in the future.

A Study on Public Nuisance in Seoul, Pusan and Daegu Cities Part I. Survey on Air Pollution and Noise Level (공해(公害)에 관(關)한 조사연구(調査硏究) 제일편(第一編) : 서울, 부산(釜山), 대구(大邱) 지역(地域)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 비교조사(比較調査) 연구(硏究))

  • Cha, Chul-Hwan;Shin, Young-Soo;Lee, Young-Il;Cho, Kwang-Soo;Choo, Chong-Yoo;Kim, Kyo-Sung;Choi, Dug-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.4 no.1
    • /
    • pp.41-64
    • /
    • 1971
  • During the period from July 1st to the end of November 1970, a survey on air pollution and noise level was made in Seoul, Pusan and Taegu, the three largest cities in Korea. Each city was divided into 4-6 areas; the industrial area, the semi-industrial area, the commercial area, the residential area, the park area and the downtown area. Thirty eight sites were selected from each area. A. Method of Measurement : Dustfall was measured by the Deposit Gauge Method, sulfur oxides by $PbO_2$ cylinder method, suspended particles by the Digital Dust Indicator, Sulfur dioxide ($SO_2$) and Carbon Monoxide (CO) by the MSA & Kitakawa Detector and the noise levels by Rion Sound Survey meter. B. Results: 1. The mean value of dustfall in 3 cities was $30.42ton/km^2/month$, ranging from 8.69 to 95.44. 2. The mean values of dustfall by city were $33.17ton/km^2/month$ in Seoul, 32.11 in Pusan and 25.97 in Taegu. 3. The mean values of dustfall showed a trend of decreasing order of semi-industrial area, downtown area, industrial area, commercial area, residential area, and park area. 4. The mean value of dustfall in Seoul by area were $52.32ton/km^2/month$ in downtown, 50.54 in semi-industrial area, 40.37 in industrial area, 24,19 in commercial area, 16.25 in park area and 15.39 in residential area in order of concentration. 5. The mean values of dustfall in Pusan by area were $48.27ton/km^2/month$ in semi-industrial area, 36.68 in industrial area 25.31 in commercial area, and 18.19 in residential area. 6. The mean values of dustfall in Taegu by area were $36.46ton/km^2/month$ in downtown area, 33.52 in industrial area, 20.37 in commercial area and 13.55 in residential area. 7. The mean values of sulfur oxides in 3 cities were $1.52mg\;SO_3/day/100cm^2\;PbO_2$, ranging from 0.32 to 4.72. 8. The mean values of sulfur oxides by city were $1.89mg\;SO_3/day/100cm^2\;PbO_2$ in Pusan, 1.64 in Seoul and 1.21 in Taegu. 9. The mean values of sulfur oxides by area in 3 cities were $2.16mg\;SO_3/day/100cm^2\;PbO_2$ in industrial area, 1.69 in semi-industrial area, 1.50 in commercial area, 1.48 in downtown area, 1.32 in residential area and 0.94 in the park area, respectively. 10. The monthly mean values of sulfur oxides contents showed a steady increase from July reaching a peak in November. 11. The mean values of suspended particles was $2.89mg/m^3$, ranging from 1.15 to 5.27. 12. The mean values of suspended particles by city were $3.14mg/m^3$ in Seoul, 2.79 in Taegu and 2.25 in Pusan. 13. The mean values of noise level in 3 cities was 71.3 phon, ranging from 49 to 99 phon. 14. The mean values of noise level by city were 73 phon in Seoul, 72 in Pusan, and 69 in Taegu in that order. 15. The mean values of noise level by area in 3 cities showed a decrease in the order of the downtown area, commercial area, industrial area and semi-industrial area, park area and residential area. 16. The comparison of the noise levels by area in 3 cities indicated that the highest level was detected in the downtown area in Seoul and Taegu and in the industrial area in Pusan. 17. The daily average concentration of sulfur dioxides ($SO_2$) in 3 cities was 0.081 ppm, ranging from 0.004 to 0.196. 18. The daily average concentrations of sulfur dioxides by city were 0.092 ppm in Seoul, 0.089 in Pusan and 0.062 in Taegu in that order. 19. The weekly average concentration of carbon monoxides(CO) was 27.59 ppm. 20. The daily average concentrations of carbon monoxides by city were 33.37 ppm. in Seoul, 25.76 in Pusan and 23.65 in Taegu in that order. 21. The concentration of $SO_2$ and CO reaches a peak from 6 p. m. to 8 p. m. 22. About 3 times probably the daily average concentration of CO could be detected in the downtown area probably due to heavy traffic emission in comparison with that in the industial area. 23. As for daily variation of the concentration of $SO_2$ and CO it was found that the concentration maintains relatively higher value during weekdays in the industrial area and on the first part of the week in the downtown area.

  • PDF

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

A Studs on Farmers Syndrome and Its Risk Factors of Vinylhouse Workers and Evaluation of Risk Factors of Vinylhouse Works (일부 농촌지역 비닐하우스 농사자들의 작업환경 및 농부증 실태와 관련요인평가)

  • Lee, Jung-Jeung
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.1
    • /
    • pp.101-119
    • /
    • 2004
  • Objectives: In order to estimate risk factors affecting the health of vinylhouse workers and harmful environments in vinylhouse working. Methods: The investigator performed questionnaires and laboratory examinations on 102 vinylhouse workers and 69 farmers in 7 myoens (Korean subcounties). one eup (a Korean town), Goryeong-gun, Gyeongsangbuk-do between April 8 and 18, 2004 (for 11 days), and measured the heavy metal in the air and the soil, temperature, humidity, air current, harmful gases in vinylhouses. Results: Even in cloudy days, the temperature in vinylhouses in daylight was $33.4^{\circ}$ and the temperature difference between inside and outside vinylhouses was around $16^{\circ}$. Oxygen concentration was similar inside and outside vinylhouses, while carbon dioxide concentration was lower inside than outside vinylhouses. Carbon monoxide was not detected. In the air inside vinylhouses, cadmium was not detected. Lean concentration in the soil was lower inside vinylhouses than outside vinylhouses at surface, while cadmium concentration was similar inside and outside vinylhouses in the soil except some areas. Out of male vinylhouse workers. 16.4---- were positive farmer's syndrome and 49.2---- were suspicious, while out of females, 41.5---- were positive and 46.3---- were suspicious. Out of male farmers, 30.4---- were positive farmer's syndrome, while out of female farmers, 60.0---- were positive and 28.3---- were suspicious. There was no difference between vinylhouse workers and farmers in the distribution of hypertension and abnormal liver function, while diabetes mellitus was more common in farmers than in vinylhouse workers. Vinylhouse working, sex, and hours of farming per day were selected as significant variables affecting farmer's syndrome in this study, and the rate of positive farmer's syndrome was rather lower in vinylhouse workers than in farmers. Females were higher than males in the rate, and those who farmed at least 10 hours per day were higher in the rate than those who farmed less than 10 hours per day. Out of the vinylhouse workers, no differences were found between the distribution of farmer's syndrome and farming-related variables such as the total period of farming, the size of farm land, the mean farming hours per day, the number of family members who farm together, the frequency of scattering agricultural chemicals. In addition, there were no differences between the distribution and the wearing masks and protectors and personal sanitation among those who scattered agricultural chemicals by themselves. There were no differences found in blood lean concentration, urinary cadmium concentration, serum cholinesterase, and hemoglobin according to the distribution of farmer's syndrome. In the vinylhouse workers, females were higher than males in the rate of farmer's syndrome, and those who farmed at least 10 hours per day were higher in the rate than those who farmed less than 10 hours per day. Meanwhile, the rate was lower in those who slept at least 8 hours a day than in those who slept less than 8 hours. Conclusions: In conclusion, the physical environments inside vinylhouses were harmful, but no significant difference was found in harmfulness of the chemical environments. The chronic diseases such as farmer's syndrome. hypertension, diabetes, and dyshepatia were not common in the vinylhouse workers than in the farmers. Meanwhile, farmer's syndrome was more common in the vinylhouse workers who worked longer and slept less.

  • PDF