• Title/Summary/Keyword: Carbon monoxide

Search Result 1,001, Processing Time 0.023 seconds

A Study on Prevention of Accidents of Carbon Monoxide Leak from Gas Boilers (가스보일러 일산화탄소 누출사고 경감에 관한 연구)

  • Song, Jaechang;Kwon, Hweeung;Lee, Younghee;Moon, Il
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.277-281
    • /
    • 2012
  • This work is concerned with a plan for preventing accidents of CO gas leak from gas boilers, involving the enforcement of installations of both CO alarm system and condensing boilers, and financial support of government grants. If amongst 1,460,000 beneficiaries of basic livelihood security, one million households in use of gas boilers receive 3-year support of 200,000 won, the difference of prices between common and condensing boilers, the government grants would be 2,000 billion won. If 3 million common householders are in 3-year support of 100,000 won, government grants would be 3,000 billion won. Therefore, 3-year grand total of government grants would be 5,000 billion won. Finance for government grants can be purveyed from energy saving; yearly 2,000 billion won of energy saving by enforcing to replace one million existing boilers with condensing boilers, leading to 2 trillion won of energy saving for 10 years. In this way, 6,000 billion won of 3-year grand total of government grants for CO alarm system and condensing boilers can be purveyed. The rest amount would be fundraised for energy savings. We claim that our proposal can make an achievement of more than 50% reduction of CO leak accidents during 10 years.

Effect of Pyridine on Toluene Diisocyanate (TDI) Synthesis Using Direct Carbonylation over Pd/SiO2 (Toluene diisocyanate(TDI) 합성을 위한 Pd/SiO2 촉매상 직접 카보닐화반응에서의 피리딘 첨가효과)

  • Seo, Myung-Gi;Kim, Seongmin;Lee, Dae-Won;Lee, Kwan-Young
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.417-420
    • /
    • 2012
  • This study is about reduction reaction making 2, 4-dinitrotoluene (2, 4-DNT) to 2, 4-toluene diisocyanate (2,4-TDI) with Pd/$SiO_2$. Catalytic systems based on Pd/$SiO_2$ at about $200^{\circ}C$ and under 100 bars of carbon monoxide. We studied the effect of pyridine on the yield of the TDI. TDI was not created without pyridine, but created with pyridine, at the reaction result. According to research, homogeneous synthesis of TDI with direct carbonylation, palladium and pyridine complexion is known to catalyze. When adding pyridine the reason of TDI synthesis is palladium leaching, ICP-AES was performed to confirm it. As a result, the proportion of Pd loaded in $SiO_2$ was decreased 52% than before, after the reaction by adding 20 vol% pyridine. Generating TDI by adding pyridine might be the effect of the complex ion, which is composed of leached palladium and pyridine.

Matrix Modification for Atomic Absorption Spectrophotometric Determination of Volatile Elements (Ⅱ). Determination of Trace Germanium by Electrothermal Atomization (휘발성 원소들의 원자흡수 분광분석을 위한 매트릭스 개선에 관한 연구(제2보). 전열 원자화에 의한 흔적량 게르마늄의 정량)

  • Choi, Ho Sung;Choi, Jong Moon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.2
    • /
    • pp.109-116
    • /
    • 1996
  • A matrix modification was studied for the determination of trace germanium in mineral waters by electrothermal atomic absorption spectrophotometry (ET-AAS). For this, the type and quantity of modifier as well as the use of auxiliary modifier were investigated to realize the efficient modification. Germanium suffers from low sensitivity and poor reproducibility in ET-AAS determination because of the premature loss of germanium via volatile germanium monoxide formation when heated in the presence of carbon. Therefore, the addition of a matrix modifier is necessary to stablize the germanium, thermally and chemically. By the addition of palladium (10 ${\mu}g/mL)$ as a single modifier to the sample containing 500 ng/mL germanium, the charring temperature could be raised from 800 to $1000^{\circ}C$, and its absorbance was also increased, but the atomization temperature was not raised. In this case, the absorbance of germanium was not changed in the range of 10∼70 ${\mu}g/mL$ of palladium added. On the other hand, it was considered that the use of a mixed modifier could modifiy the matrix more effectively than with a single modifier. The best results were obtained by using 1% ammonium hydroxide as an auxiliary modifier together with 10 ${\mu}g/mL$ palladium. The charring temperature could be raised from 800 to $1100^{\circ}C$, without any change of the atomization temperature. With above optimum conditions, the trace amount of germanium in several mineral waters were determined by a calibration curve method, and good recoveries of more than 95% were also obtained in the samples in which a given amount of germanium was spiked. The detection limit of this method was about 6.9 ng/mL.

  • PDF

결체조직질병(結締組織疾病)에 병발(倂發)된 간질성폐병변(間質性肺病變)에 대(對)한 활혈화어법(活血化瘀法)의 치료효과(治燎效果) 연구(硏究)

  • 장항홍
    • Journal of Haehwa Medicine
    • /
    • v.5 no.2
    • /
    • pp.497-497
    • /
    • 1997
  • 간질성폐질변(間質性肺疾變)은 결체조직질병(結締組織疾病)의 상견(常見)되는 병발증(倂發證)이지만, 지금까지는 이상적(理想的)인 치료법(治療法)이 없었다. 본(本) 연구(硏究)는 본병(本病)의 병리기전(病理機轉)이 중의(中醫)에서의 "어혈(瘀血)"증(證) 상호(相互) 유사(類似)한 것으로부터 시작(始作)하여, 중의(中醫)의 "활혈화어법(活血化瘀法)"과 결합(結合)하여 치료(治療)하면서 환자(患者)의 폐기능(肺氣能) 검사결과(檢査結果)의 변화(變化)를 추적(追跡)해, 그 치료효과(治療效果)에 대(對)한 평가(評價)를 내리는 작업(作業)으로 이루어졌다. 먼저 풍습과(風濕科)에 의뢰(依賴)하여 결체조직질병(結締組織疾病)에 간질성폐병(間質性肺病)이 병발(倂發)한 환자(患者)를 선별(選別)한 후(後)에, 서의치료(西醫治療) 통(通)해서 그 원발성(原發性) 질병(疾病)이 은정(隱靜)한 상태(狀態)에까지 이르도록 한 후(後), 필요(必要)한 최저량(最低量)의 서의약(西醫藥)만을 유지(維持)케 하였다. 환자(患者)의 의사(意舍)에 따라서 두 개의 조(組)로 나누어, 실험군(實驗群)은 중의(中醫)에서 회진(會診)하고, Raynaud 증후군(症候群)의 유무(有無)에 따라서, 당귀사역탕(當歸四逆湯) 혹(或)은 혈부축어탕(血府逐瘀湯)을 농축분제(濃縮粉劑)로 투여(投與)하며 연속(連續)하여 6개월간(個月間) 치료(治療)하였다. 대조군(對照群)의 경우(境遇)에는 중의(中醫)가 회진(會診)하지 않았다. 14개월(個月)동안 모두 실험군(實驗群) 23례(例)와 대조군(對照群) 16례(例)를 대상(對象)으로 연구(硏究)를 하였는데, 모두 여성환자(女性患者)였다. 압축성폐용량(壓軸性肺用量)(FVC), 폐총용량(肺總用量)(TCL), carbon monoxide에 대(對)한 폐(肺)의 확산능력(擴散能力)(DLCO), 그리고 폐포공기량(肺泡空氣量)(VA)에 대(對) DCLO의 비(比)를 지표(指標)로 삼아, 폐기능(肺氣能)의 손상정도(損傷程度)에 따라서 box plot으로 분석(分析)하고, 폐기능(肺氣能)의 손상(損傷)을 측정(測定)하는 시스템을 만들었다. 실험결과(實驗結果), 실험군(實驗群)이 대조군(對照群)에 비(比)해서 치료(治療) 전(前)보다 명현(明顯)한 개선(改善)이 있었다. 폐기능(肺氣能)을 검사(檢査)한 수치(數値)들을 일반적(一般的)으로 통계처리(統計處理)한 것을 응용(應用)하고, TCL과 FVC의 모형식(模型式)을 만든 결과(結果), 실험군(實驗群)에서 FVC가 치료과정(治療過程)의 기간(其間)과 정비례(正比例)하여 향상(向上)되고, 또한 치료효과(治療效果)가 명현(明顯)하게 나타나기 시작(始作)하는 시기(時期)가 중의(中醫) 치료과정(治療過程)을 거친 실험군(實驗群)의 제(第)12개(個)에서 DLCO와 DLCO/VA의 향상(向上)이 나타나는 시기(時期)와 거의 일치(一致)하는 것을 발견(發見)하였다.

  • PDF

Preparation of High Spin Five-Coordinate Iron(II) Complexes of 1,4,8,11-Tetraazacyclotetradecane and High Spin Six-Coordinate Iron(II) Complexes of 1,5,8,12-Tetraazadodecane (1,4,8,11-테트라아자사이클로테트라데칸의 높은 스핀 다섯배위철(II) 착화합물과 1,5,8,12-테트라아자도데칸의 높은 스핀 여섯배위철(II) 착화합물의 합성)

  • Myunghyun Paik Suh
    • Journal of the Korean Chemical Society
    • /
    • v.24 no.2
    • /
    • pp.139-145
    • /
    • 1980
  • High spin iron(II) complexes of 1,4,8,11-tetraazacyclotetradecane (cyclam), a macrocyclic ligand, and 1,5,8,12-tetraazadodecane (3,2,3-tet), a noncyclic ligand, have been prepared. The reaction of low spin $[Fe(cyclam)(CH_3CN)_2](ClO_4)_2$ with chloride ion in methanol produces high-spin $[Fe(cyclam)Cl]ClO_4$. Although $[Fe(cyclam)(CH_3CN)_2](ClO_4)_2$ is low spin, $[Fe(3,2,3-tet)(CH_3CN)_2](ClO_4)_2$ isolated in the present study is high spin. This difference is explained in terms of the smaller constrictive effect exerted by the noncyclic ligand than the cyclic ligand. The isolation of $[Fe(cyclam)Cl]ClO_4$ provides evidences against the current view that the presence of either unsaturation or substituents on the macrocyclic ligands is necessary for the successful preparation of high spin five-coordinate iron (II) complexes. Reactions of $[Fe(cyclam)Cl]ClO_4\;and\;[Fe(3,2,3-tet)(CH_3CN)_2](ClO_4)_2$ with carbon monoxide yield low spin six-coordinate $[Fe(cyclam)Cl(CO)]ClO_4\;and\;[Fe(3.2,3-tet)(CH_3CN)(CO)](ClO_4)_2$, respectively.

  • PDF

Paraquat Induced Heme Oxygenase-1 in Dopaminergic Cells (도파민 세포에서 Paraquat에 의한 헴산화효소-1의 유도)

  • Chun Hong Sung
    • KSBB Journal
    • /
    • v.20 no.1 s.90
    • /
    • pp.21-25
    • /
    • 2005
  • Paraquat, a widely used herbicide, has been suggested as a potential risk factor for Parkinson's disease. Heme oxygenase-1(HO-1), a marker for oxidative stress and endoplasmic reticulum(ER) stress, is known to catalyze heme to biliverdin, carbon monoxide and free iron in response to various stimuli. Here we show that paraquat activates HO-1 expression in a time-and dose-dependent manner in substantia nigra(SN) dopaminergic neuronal cells. Activation of Ho-1 by paraquat was regulated primarily at the level of gene transcription. Deletion analysis of the promoter and the 5' distal enhancers, E1 and E2, of the HO-1 gene revealed that the E2 enhancer is a potent inducer of the paraquat-dependent Ho-1 gene expression in dopamninergic neuronal cells. Mutational analysis of the E2 enhacer further demonstrated that the transcription factor activator protein-1(AP-1) plays an important role in mediating paraquat-induced HO-1 gene transcription. Moreover, using specific inhibitors of the mitogen-activated protein kinases(MAPKs), we investigated the role of paraquat and MAPKs for HO-1 gene regulation in dopaminergic cells. The c-Jun N-terminal kinase(JNK) inhibitor SP600125 significantly suppressed the expression of HO-1 by paraquat. All these results demonstrate that induction of HO-1 by paraquat requies the activation of the AP-1 and JNK pathway.

Annual Change in Pulmonary Function and Clinical Characteristics of Combined Pulmonary Fibrosis and Emphysema and Idiopathic Pulmonary Fibrosis: Over a 3-Year Follow-up

  • Kim, Yu Jin;Shin, Seong Hyun;Park, Jeong-Woong;Kyung, Sun Young;Kang, Shin Myung;Lee, Sang-Pyo;Sung, Yon Mi;Kim, Yoon Kyung;Jeong, Sung Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.77 no.1
    • /
    • pp.18-23
    • /
    • 2014
  • Background: Combined pulmonary fibrosis and emphysema (CPFE) have different pulmonary function tests (PFTs) and outcomes than idiopathic pulmonary fibrosis (IPF). The intention of this study was to identify unknown differences between CPFE and IPF by a retrospective comparison of clinical data including baseline and annual changes in pulmonary function, comorbidities, laboratory findings, clinical characteristics and cause of hospitalization. Methods: This study retrospectively enrolled patients with CPFE and IPF who had undergone PFTs once or several times per year during a follow-up period of three years. Baseline clinical characteristics and the annual changes in the pulmonary function during the follow-up period were compared between 26 with CPFE and 42 patients with IPF. Results: The baseline ratio of forced expiratory volume in one second to forced vital capacity ($FEV_1$/FVC%) in patients with CPFE was lower than that in patients with IPF ($78.6{\pm}1.7$ vs. $82.9{\pm}1.1$, p=0.041). The annual decrease in $FEV_1$/FVC in the CPFE was significantly higher than in the IPF. The annual decreases in diffusion capacity of carbon monoxide and FVC showed no significant differences between the two groups. The symptom durations of cough and sputum were in the CPFE significantly lower than in the IPF. The serum erythrocyte sedimentation rate level at the acute stage was significantly higher than in the IPF. There were no significant differences in the hospitalization rate and pneumonia was the most common cause of hospitalization in both study groups. Conclusion: The annual decrease of $FEV_1$/FVC was in patients with CPFE significantly higher than in the patients with IPF.

A study on the management of harmful working environments for Increase of Labor productivity. (노동생산성 향상을 위한 유해작업환경관리에 관한 연구)

  • 조태웅;유익현;박성애
    • Journal of Environmental Health Sciences
    • /
    • v.3 no.1
    • /
    • pp.27-44
    • /
    • 1976
  • This study was carried out to evaluate the harmful factors in working environments and to investigate the labor productivity after improvement of environments, surveying 93 industrial establishments of 10 industries located in Youngdeungpo industrial area in Seoul. The results obtained were as follows: 1) The highest noise level of 125dB(A) was indicated at the rolling process of transport equipment manufacturing industry. 2) The best illumination level was shown in precise machinery industry and the worst was indicated in rubber products, metallic products and transport equipment manufacturing industries. 3) Thermal conditions were above threshold limit value (TLV) at more than two processes of all industries except printing industry. 4) The highest dust concentration was determined in textile and wearing manufacturing industry. 5) Organic solvents were detected at 52 processes in 93 industrial establishments and 33 processes of them showed higher than TLV. The results about harmful chemicals were as follows: a) sulfur dioxide ($SO_2$)was determined higher than TLV on welding process of metallic product manufacturing industry and heat treatment process of transport equipment manufacturing industry. b) Carbon monoxide (CO) concentration was 700ppm at heat treatment process of transport equipment manufacturing industry, indicating 14 times of TLV. c) vinylchloride concentration in the air of PVC raw material mixing process and PVC preparation process of chemical product manufacturing industry was determined higher than TLV. d) Hydrochloride (HCl) concentration in the air of wire expanding process of transport equipment manufacturing industry was determined higher than TLV. 7) Higher values of lead concentration than TLV were determined at lead welding metallic product manufacturing industry and type planting process of process of printing industry, $1.8mg/m^3$ and $0.3mg/m^3$ respectively. 9) 22, 968 of 52, 855 workers (i.e. 43.5%) in 93 industries were exposed to various harmful agents. 10) It was found that the improvement of illumination in electric apparatus manufacturing industry (from 20~40 lux to 420 lux) resulted in an increase in productivity of 6.5% per capita and a decrease in faulty products of 19%. 11) Improvement of environments using local exhaust ventilation system resulted in a decrease of harmful substances lower than TLV and an increase in productivity of 11.4%. 12) Improvement of shovelling tools based on ergonomics resulted in a reduction in energy expenditure of 25.3% and an increase in productivity of 32.2% per capita.

  • PDF

The Changes of CO Gas Sensing Properties of ZnO and $SnO_2$ with Addition $TiO_2$ ($TiO_2$첨가에 의한 ZnO와 $SnO_2$의 일산화탄소 감응특성 변화)

  • Kim, Tae-Won;Choi, U-Sung;Jun, Seon-Taek
    • Korean Journal of Materials Research
    • /
    • v.8 no.4
    • /
    • pp.312-316
    • /
    • 1998
  • ZnO- TiO$_2$, and Sn0$_2$ - Ti0$_2$ ceramic composites doped with TiO$_2$ were prepared and their electrical and 1000ppm CO gas sensing properties were investigated. The phases of samples were analyzed by XRD, and the microsturctures of the fractured surface of samples were observed by SEM. A carbon monoxide gas sensitivity was de¬fined as the ratio of the resistance in dry air atmosphere(R$drt air$) to the resistance in 1000ppm CO gas atmosphere(R$_co$) The CO gas sensitivity of Smol% Ti0$_2$-added ZnO decreased about 1.7 times compared to that of pure ZnO. On the other hand, the maximum CO gas sensitivity of Ti0$_2$-added SnO$_2$ increased about 2.5 times compared to that of pure SnO$_2$. Therefore, the CO gas sensitivies of SnO$_2$-TiO$_2$ composite were better than those of ZnO- Ti0$_2$ and the temper¬ature range showing the maximum sensitivity for Sn0$_2$-TiO$_2$ composite was lower than that for ZnO- Ti0$_2$.

  • PDF

Synthesis of Binuclear Bismacrocyclic Iron(II) Complex by the Aerobic Oxidation of Iron(II) Complex of 1,4,8,11-Tetraazacyclotetradecane

  • Myunghyun Paik Suh;Gee-Yeon Kong;Il-Soon Kim
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.4
    • /
    • pp.439-444
    • /
    • 1993
  • The aerobic oxidation of the Fe(II) complex of 1,4,8,11-tetraazacyclotetradecane, [Fe(cyclam)$(CH_3CN)_2](ClO_4)_2$, in MeCN in the presence of a few drops of $HClO_4$ leads to low spin Fe(III) species [Fe(cyclam)$(CH_3CN)_2](ClO_4)_3$. The Fe(III) cyclam complex is further oxidized in the air in the presence of a trace of water to produce the deep green binuclear bismacrocyclic Fe(II) complex $[Fe_2(C_{20}H_{36}N_8)(CH_3CN)_4](ClO_4)_4{\cdot}2CH_3CN$. The Fe(II) ions of the complex are six-coordinated and the bismacrocyclic ligand is extensively unsaturated. $[Fe_2(C_{20}H_{36}N_8)(CH_3CN)_4](ClO_4)_4{\cdot}2CH_3CN$ crystallizes in the monoclinic space group $P2_1/n$ with a= 13.099 (1) ${\AA}$, b= 10.930 (1) ${\AA}$, c= 17.859 (1) ${\AA}$, ${\beta}$= 95.315 $(7)^{\circ}$, and Z= 2. The structure was solved by heavy atom methods and refined anisotropically to R values of R= 0.0633 and $R_w$= 0.0702 for 1819 observed reflections with F > $4{\sigma}$ (F) measured with Mo K${\alpha}$ radiation on a CAD-4 diffractometer. The two macrocyclic units are coupled through the bridgehead carbons of ${\beta}$-diimitie moieties by a double bond. The double bonds in each macrocycle unit are localized. The average bond distances of $Fe(II)-N_{imine}$, $Fe(II)-N_{amine}$, and $Fe(II)-N_{MeCN}$ are 1.890 (5), 2.001 (5), and 1.925 (6) ${\AA}$, respectively. The complex is diamagnetic, containing two low spin Fe(II) ions in the molecule. The complex shows extremely intense charge transfer band in the near infrared at 868 nm with ${\varepsilon}$= 25,000 $M^{-1}cm^{-1}$. The complex shows a one-electron oxidation wave at +0.83 volts and two one-electron reduction waves at -0.43 and-0.72 volts vs. Ag/AgCl reference electrode. The complex reacts with carbon monoxide in $MeNO_2$ to form carbonyl adducts, whose $v_{CO}$ value (2010 $cm^{-1}$) indicates the ${\pi}$-accepting property of the present bismacrocyclic ligand.