• Title/Summary/Keyword: Carbon monoxide

Search Result 1,001, Processing Time 0.025 seconds

Relationship between Exposure Concentrations to Methylene Chloride in Air and Carboxyhemoglobin Levels in Blood of Workers Engaged in Blowing, and Cleaning Operations (발포 및 세척 공정 근로자의 공기중 Methylene Chloride 노출 농도와 혈중 Carboxyhemoglobin 수준간의 상관관계에 관한 연구)

  • Shin, Yong Chul;Kim, Yang Ho;Yi, Gwang Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.87-98
    • /
    • 1999
  • The objectives of this study were to evaluate exposures to airborne methylene chloride and postshift carboxyhemoglobin (COHb) in blood of workers engaged in processes using blowing or cleaning agents, and to investigate correlation between methylene chloride concentrations and the blood COHb levels of workers. The geometric mean (GM) of workers' exposures (8 hour-time weighted averages, TWA) to airborne methylene chloride during cleaning molds using rags wetted with the solvent in the manufacture of flexible polyurethane foam (GM = 61.4 ppm), during operating the dip tank for cleaning molds in the manufacture of lens (GM = 61.0 ppm), and during cleaning the blowing nozzles by spraying the solvent in the manufacture of shoes (GM = 117.2 ppm) were exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$)-Time Weighted Average (TWA) (50 ppm). The COHb levels were significantly different among groups (p<0.05). The average COHh levels in blood of non-smoking workers were 2.0% in. low-level (<50 ppm) exposure group, and 3.9 % in high-level (>50ppm) exposure group. The average COHb levels in smoking workers were 3.1% in low-level exposure group, and 4.8% in high-level exposure group. The blood COHb levels of no-exposed workers to methylene chloride were 1.8% in non-smoking group, and 2.8% in smoking group. It was found that the COHb level dependeds on the methylene chloride concentration and smoking habit, and was highly correlated with methylene chloride concentration in air. The correlation coefficient was 0.81 among non-smoking workers. The estimated COHb level (3.6%) and 95% upper confidence limit (4.0%) corresponding to TLV-TWA of methylene chloride exceeded the current ACGIH Biological Exposure Index (COHb 3.5%) for carbon monoxide. The estimated COHb level (5.4%) at 100 ppm exceeded the standard (5%) recommended by National Institute for Occupational Safety and Health (NIOSH) for preventing adverse cardiovascular effect. The estimated COHb value and 95% upper confidence limit at 25 ppm of the Occupational Safety and Health. Adminstration (OSHA) Permissible Exposure Limit-TWA (PEL-TWA) were 2.6% and 3.0%, respectively. It is suggested that COHb in blood be kept below 3.0% to comply with OSHA PEL-TWA.

  • PDF

Three Case Reports of Patients with Secondary Dementia Treated with Korean Traditional Medicine, Especially Boshiniknoe-tang-gami (속발성 치매 환자에 대한 보신익뇌탕가미방의 효과 3례)

  • Bae, Go-eun;Cho, Jae-hyun;Choi, Jin-yong;Seo, Hee-jeong;Shim, So-hyun;Kwon, Jung-nam;Hong, Jin-woo;Kim, So-yeon;Choi, Jun-young;Han, Chang-woo;Yun, Young-ju;Park, Seong-ha;Lee, In
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.5
    • /
    • pp.628-640
    • /
    • 2017
  • Purpose: To describe the effectiveness of traditional Korean medicine (TKM) on the patients with secondary dementia (case 1: Rt. MCA infarction; case 2: traumatic subacute subdural hemorrhage and traumatic intracranial hemorrhage; case 3: delayed encephalopathy after carbon monoxide poisoning). Methods: We used a complete TKM treatment. The acupoints used were as follows: acupoints frequently used in hemiparesis (GV20, GV24, ST4, LI11, LI14, ST36, GB34, SP9, and LR3), and we used herbal medicine (補腎益腦湯加味, Boshiniknoe-tang-gami). The efficacy was evaluated using the Mini-Mental State Examination for Dementia Screening (MMSE-DS) and the Modified Barthel Index (MBI). Results: After treatment, the total MMSE-DS score was increased from 14 to 24 (case 1), 14 to 19 (case 2), and 0 to 17 (case 3). The total K-MBI was increased from 30 to 44 (case 1), 82 to 86 (case 2), and 30 to 86 (case 3) Conclusions: We suggest that TKM could positively influence cognition and improve activity of daily living (ADL). This study has limitations, so further studies are needed.

Catalytic Reduction of Nitric Oxide by Carbon Monoxide over Perovskite-Type Oxide (페롭스카이트형 산화물에서 일산화탄소에 의한 질소산화물의 환원반응)

  • Moon, Haeng-Chul;Sun, Chang-Bong;Lee, Gun-Dae;Ahn, Byuong-Hyun;Lim, Kwon-Taek;Hong, Seong-Soo
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.407-414
    • /
    • 1999
  • We have studied the reduction of NO by CO over perovskite-type oxides prepared by malic and method. The catalysts were modified to enhance the activity by substitution of metal into A or B site of perovskite oxides. In the $LaCoO_3$ type catalyst, the partial substitution of Sr into A site enhanced the catalytic activity on the conversion of NO at less than $350^{\circ}C$. In the $La_{0.6}Sr_{0.4}Co_{1-x}Fe_xO_3$ catalyst, the partial substitution of Fe or Mn into B site enhanced the conversion of NO, but excess amount of Fe decreased the conversion of NO. In addition, $La_{0.6}Sr_{0.4}Co_{0.8}Fe_{0.2}O_3$ mixed with $SnO_2$ or $MnO_2$ showed the synergy effect on the reduction of NO. The introduction of water into reactants feed decreased the catalytic activity but the deactivation was shown to be reversible. The introduction of $SO_2$ into reactants feed also decreased the catalytic activity.

  • PDF

$NO_{2}$ Sensing Properties of Oxide Semiconductor Thick Films (산화물 반도체형 후막 가스 센서의 이산화질소 감지 특성)

  • Kim, Seung-Ryeol;Yun, Dong Hyun;Hong, Hyung-Ki;Kwon, Chul-Han;Lee, Kyu-Chung
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.451-457
    • /
    • 1997
  • The thick films of oxide semiconductors such as $WO_{3}$, $SnO_{2}$ and ZnO for the $NO_{2}$ detection of sub-ppm range have been prepared and their characteristics were investigated. It is showed that the optimum operating temperatures of the sensors are $300^{\circ}C$ and $220{\sim}260^{\circ}C$ for $WO_{3}$-based and $SnO_{2}$-based thick films, and ZnO-based thick films, respectively. Since the resistance of ZnO-based thick films are extremely high($>10^{6}{\Omega}$), the signal to noise ratio was comparatively low. In order to determine the selectivity, the films are exposed to the interfering gases such as ozone, ammonia, methane and the mixture of carbon monoxide and propane. $WO_{3}$-ZnO(3 wt.%) and $SnO_{2}-WO_{3}$(3 wt.%) thick film sensors show high sensitivity, good selectivity, excellent reproducibility and the linearity of $NO_{2}$ concentration versus sensor resistance. The preliminary results clearly demonstrated that the sensor can be successfully applied for the detection of $NO_{2}$ in sub-ppm range.

  • PDF

Fabrication and Characterization of Portable Electronic Nose System for Identification of CO/HC Gases (CO/HC 가스 인식을 위한 소형 전자코 시스템의 제작 및 특성)

  • Hong, Hyung-Ki;Kwon, Chul-Han;Yun, Dong-Hyun;Kim, Seung-Ryeol;Lee, Kyu-Chung;Kim, In-Soo;Sung, Yung-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.476-482
    • /
    • 1997
  • A portable electronic nose system has been fabricated and characterized using an oxide semiconductor gas sensor array and pattern recognition techniques such as principal component analysis and back-propagation artificial neural network. The sensor array consists of six thick-film gas sensors whose sensing layers are Pd-doped $WO_{3}$, Pt-doped $SnO_{2}$, $TiO_{2}-Sb_{2}O_{5}-Pd$-doped $SnO_{2}$, $TiO_{2}-Sb_{2}O_{5}-Pd$-doped $SnO_{2}$ + Pd coated layer, $Al_{2}O_{3}$-doped ZnO and $PdCl_{2}$-doped $SnO_{2}$. The portable electronic nose system consists of an 16bit Intel 80c196kc as CPU, an EPROM for storing system main program, an EEPROM for containing optimized connection weights of artificial neural network, an LCD for displaying gas concentrations. As an application the system has been used to identify 26 carbon monoxide/hydrocarbon (CO/HC) car exhausting gases in the concentration range of CO 0%/HC 0 ppm to CO 7.6%/HC 400 ppm and the identification has been successfully demonstrated.

  • PDF

H2S Poisoning Effect and Recovery Methods of Polymer Electrolyte Membrane Fuel Cell (황화수소 피독이 고분자전해질 연료전지에 미치는 영향과 회복기법)

  • Chun, Byungdo;Kim, Junbom
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.107-114
    • /
    • 2017
  • The performance of polymer electrolyte membrane fuel cell (PEMFC) could be deteriorated when fuel contains contaminants such as carbon monoxide (CO) or hydrogen sulfide ($H_2S$). Generally, $H_2S$ is introduced in hydrogen by steam reforming of hydrocarbon which has mercaptan as odorant. $H_2S$ poisoning effect on PEMFC performance was examined on this study. Pure hydrogen injection, voltage cycling and water circulation methods were compared as performance recovery methods. The PEMFC performance was analyzed using electrochemical methods such as polarization curve, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Pure hydrogen injection and voltage cycling methods showed low recovery ratio, however, water circulation method showed high recovery ratio over 95%. Because anode was directly poisoned by $H_2S$, anode water circulation showed higher recovery ratio compared to the other methods. Water circulation method was developed to recover PEMFC performance from $H_2S$ poisoning. This method could contribute to PEMFC durability and commercialization.

Selective Oxidation of Hydrogen Over Palladium Catalysts in the Presence of Carbon Monoxide: Effect of Supports (Pd 촉매상에서 일산화탄소 존재 하 수소의 선택적 산화반응: 담체 효과)

  • Kim, Eun-Jeong;Kang, Dong-Chang;Shin, Chae-Ho
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.121-129
    • /
    • 2017
  • Pd based catalysts were prepared by impregnating palladium precursor using incipient wetness method on $TiO_2$, $Al_2O_3$, $ZrO_2$, and $SiO_2$ and were applied for the selective oxidation of $H_2$ in the presence of CO. Their physicochemical properties were studied by X-ray diffraction (XRD), $N_2$-sorption, temperature programmed desorption of CO (CO-TPD) and (CO+$H_2O$)-TPD, temperature programmed reduction of CO (CO-TPR) and XPS a. The results of CO- and (CO+$H_2O$)-TPD showed the correlation between peak temperature of TPD and catalytic activities for $H_2$ and CO conversion. The $Pd/ZrO_2$ catalyst exhibited the highest conversion of $H_2$. The addition of $H_2O$ vapor promotes the conversion of $H_2$ and CO by inducing easy desorption of CO and $H_2$ in the competitive adsorption of $H_2O$, CO and $H_2$.

Flame Retardancy and Foaming Properties of the Waste-Polyethylene(W-PE)/Waste-Ethylene vinyl acetate copolymer(W-EVA) Blend Foams (폐폴리에틸린/폐에틸렌 비닐아세테이트공중합체 블렌드 발포체의 난연 및 발포 특성에 관한 연구)

  • Moon, Sung-Chul;Jo, Byung-Wook;Choi, Jae-Kon
    • Elastomers and Composites
    • /
    • v.38 no.4
    • /
    • pp.316-325
    • /
    • 2003
  • The blends of waste-polyethylene (W-PE)/waste-ethylene vinyl acetate copolymer (W-EVA) with inorganic and phosphorous flame retardants (i.e., aluminium hydroxide, magnesium hydroxide, and so on) were prepared by melt mixing techniques at different compositions and foamed. The flame retardancy and foaming properties of the blends, limiting oxygen index (LOI), heat release rate (HRR), carbon monoxide yield (COY), total heat release (THR), effective heat of combustion (EHC), expandability and cell structure were investigated using cone calorimeter, SEM, LOI tester and polarizing microscope. When the composition ratios of the W-PE/W-EVA blends were 50/50 (w/w), and the ranges of the flame retardants contents were $175{\sim}220 phr$, we could obtain foams with the uniform and closed cell, high expandability (1900 % or more), high LOI, and low HRR values. These results depend on crosslinking and loaming conditions, a char formation and smoke suppressing effect. Aluminium hydroxide had more effect in the increase of LOI than magnesium hydroxide, while magnesium hydroxide considerably affected the decrease of HRR and COY.

Evaluation of the Prediction Performance of FDS Combustion Models for the CO Concentration of Gas Fires in a Compartment (구획실 내 가스연료 화재의 CO 농도에 대한 FDS 연소모델의 예측성능 평가)

  • Baek, Bitna;Oh, Chang Bo;Hwang, Chel-Hong;Yun, Hong-Seok
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.7-15
    • /
    • 2018
  • The prediction performance of combustion models in the Fire Dynamics Simulator (FDS) were evaluated by comparing with experiment for compartment propane gas fires. The mixture fraction model in the FDS v5.5.3 and Eddy Dissipation Concept (EDC) model in the FDS v6.6.3 were adopted in the simulations. Four chemical reaction mechanisms, such as 1-step Mixing Controlled, 2-step Mixing Controlled, 3-step Mixing Controlled and 3-step Mixed (Mixing Controlled + finite chemical reactions) reactions, were implemented in the EDC model. The simulation results with each combustion model showed similar level for the temperature inside the compartment. The prediction performance of FDS with each combustion model showed significant differences for the CO concentration while no distinguished differences were identified for the $O_2$ and $CO_2$ concentrations. The EDC 3-step Mixing Controlled largely over-predicted the CO concentration obtained by experiment and the mixture fraction model under-predicted the experiment slightly. The EDC 3-step Mixed showed the best prediction performance for the CO concentration and the EDC 2-step Mixing Controlled also predicted the CO concentration reasonably. The EDC 1-step Mixing Controlled significantly under-predict the experimental CO concentration when the previously suggested CO yield was adopted. The FDS simulation with the EDC 1-step Mixing Controlled showed difficulties in predicting the $CO_2$ concentration when the CO yield was modified to predict the CO concentration reasonably.

Studies on the Combustion of Anthracite (I). Combustion of Carbon Monoxide and the Furface (無燃炭 燃燒에 關한 硏究 (第 1 報). 一酸化炭素 燃燒反應 및 燃燒裝置)

  • Shin Byoung Sik;Shin Sei Kun
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.3
    • /
    • pp.186-192
    • /
    • 1975
  • In the course of anthracite briquet combustion, air draft is usually controlled to continue burning of definite amount of briquet in the conventional hollow clay cylinder with air inlet hole open for given time, so that a large amount of CO tends to be produced. Therefore, it is necessary to establish an improved combustion process to depress the yielding rate of CO and for this purpose, we performed a basic experiment in which combustion rate of CO was measured in the mixture of $N_2, O_2 $and CO gas with or without the presence charcoal at the various temperature. The observed results showed that the burning temperature of CO is about 680${\sim}700^{\circ}C$, further burning rate of it was increased with increasing the amount of draft. From these facts, longer combustion time and low CO generation are thus contradictory to each other and it has been long desired to make those two compatible somehow. The purpose of the present investigation lies in designing an effective new briquet stove to meet the above requirements. The essential feature of the new briquet stove consisted in the use of two hollow iron cylinders with different inside diameter. A cylindrical air jacket thus formed served as a path through which small amount of secondary air run from the bottom of the stove to the upper vent holes. Heat exchange occurred between the upgoing secondary air and the burning briquet, which lowered the combustion temperature of the briquet. The results observed were selfevident as anticipated. It was confirmed that the combustion time was increased tolerably due to the heat loss from the combustion zone and that CO in the flue gas was reoxidized at the upper portion of the stove by the upgoing hot secondary air. By this reoxidation reaction the concentration of CO in the flue gas was found to be about 1/20 of that in case the conventional clay cylinder was used as briquet jacket.

  • PDF