• Title/Summary/Keyword: Carbon flow

Search Result 1,399, Processing Time 0.027 seconds

Modeling of Solid Circulation in a Fluidized-Bed Dry Absorption and Regeneration System for CO2 Removal from Flue Gas (연소기체로부터 CO2 회수를 위한 건식 유동층 흡수-재생 공정의 고체순환 모사)

  • Choi, Jeong-Hoo;Park, Ji-Yong;Yi, Chang-Keun;Jo, Sung-Ho;Son, Jae-Ek;Ryu, Chong Kul;Kim, Sang-Done
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.286-293
    • /
    • 2005
  • An interpretation on the solid circulation characteristics in a fluidized-bed process has been carried out as a first step to simulate the dry entrained-bed absorption and bubbling-bed regeneration system for $CO_2$ removal from flue gas. A particle population balance has been developed to determine the solid flow rates and particle size distributions in the process. Effects of principal process parameters have been discussed in a laboratory scale process (absorption column: 25 mm i.d., 6 m in height; regeneration column: 0.1 m i.d., 1.2 m in height). The particle size distributions in absorption and regeneration columns were nearly the same. As gas velocity or static bed height in the absorption column increased, soild circulation rate and feed rate of fresh sorbent increased, however, mean particle diameter decreased in the absorption column. As cut diameter of the cyclone of the absorption column increased, solid circulation rate decreased, whereas feed rate of fresh sorbent and mean particle diameter in the absorption column increased. As attrition coefficient of sorbent particle increased, solid circulation rate and feed rate of fresh sorbent increased but mean particle diameter in the absorption column decreased.

Effect of Circulation Cycle of Nutrient Solution on the Dissolved Oxygen Concentration, and the Growth and Phytonutrient Contents of Leafy Vegetables Grown in DFT Systems (양액의 순환주기가 담액수경 엽채류의 용존산소 농도, 생육 및 식물영양소의 함량에 미치는 영향)

  • Seo, Tae-Cheol;Rhee, Han-Cheol;Rho, Mi-Young;Choi, Kyeong-Lee;Yun, Hyung-Kwon;Chun, Chang-Hoo
    • Journal of Bio-Environment Control
    • /
    • v.18 no.2
    • /
    • pp.112-118
    • /
    • 2009
  • To determine the effects of circulation frequency of nutrient solution, three frequencies of 10min. on/10min. off; 10min. on/110min. off; and 10min. on/1,430min. off. treatments were applied to leafy vegetable production using deep flow technique (DFT) systems and their growth and phytonutrient content were investigated. In the 10min. on/I,430min. off treatment, dissolved oxygen concentration (DOC) 17 days after treatment decreased to 2.8mg. $L^{-1}$, known to be a low DOC that causes hypoxia, and thereafter decreased to 1.5mg. $L^{-1}$ 20 days after treatment. Fresh weight of 7 leafy vegetables in the 10min. on/1,430min. off treatment was lower by 0${\sim}$24% than those in the 10min. on/110min. off treatment, and those in the 10min. on/10min. off was higher by -2${\sim}$34% than those in the 10min. on/110min. off treatment as control. As the more frequent circulation was applied, the higher phosphorous content and the lower carbon to nitrogen ratio (C/N ratio) and total ascorbic acid contents were resulted. Results indicate that the circulation frequency of 110min, on/110min. off could be recommended for the production of the tested leafy vegetables in DFT systems.

Effect of Unexpected Foaming Incident on Nitrogen Removal in a Vertical Subsurface Wetland (수직지하 흐름형 습지에서 거품발생이 질소제거에 미치는 영향)

  • Cheng, Jing;Guerra, Heidi B.;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.334-343
    • /
    • 2019
  • A lab-scale vertical flow subsurface (VFS) wetland composed of three parallel columns with polypropylene synthetic fiber as main substrate was operated. Piggery stormwater diluted from swine excreta was fed to the wetland on the basis of three different hydraulic regimes or hydraulic retention time (HRT) of 2, 4, and 8 days with daily internal recirculation. Then, monitoring of common water quality parameters was carried out. Unexpectedly, an increase of effluent COD concentration accompanying the appearance of foams was observed during a distinct period in the wetland with HRT 2, 4, and 8 days, successively. Subsequently, a series of experiments was conducted to investigate the origin of the foams. Foams and the increase of COD concentration were found to be induced by the release of organic matter from the synthetic polypropylene fiber which was fed with piggery stormwater. Meanwhile, nitrogen removal was found to be enhanced during a period which overlapped the distinct foaming period signifying that foaming played two important functions in biological nitrogen removal. Foams which form rapidly and then burst easily could hold up and then release oxygen for nitrification. Foams which contain organic surfactants could serve as carbon sources for denitrification as well. Hence, nitrogen removal was enhanced during the foaming stage. After that, COD concentration decreased slowly to a level prior to the foaming stage, and nitrogen removal efficiency declined as well.

Hydrodynamic Properties of Interconnected Fluidized Bed Chemical-Looping Combustors (상호 연결된 유동층 매체 순환식 연소로의 수력학적 특성)

  • Son, Sung Real;Go, Kang Seok;Kim, Sang Done
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.185-192
    • /
    • 2010
  • The chemical-looping combustion(CLC) has advantages of no energy loss for separation of $CO_2$ without $NO_x$ formation. This CLC system consists of oxidation and reduction reactors where metal oxides particles are circulating through these two reactors. In the present study, the reaction kinetic equations of iron oxide oxygen carriers supported on bentonite have been determined by the shrinking core model. Based on the reactivity data, design values of solid circulation rate and solids inventory were determined for the rector. Two types of interconnected fluidized bed systems were designed for CLC application, one system consists of a riser and a bubbling fluidized bed, and the other one has a riser and two bubbling fluidized beds. Solid circulation rates were varied to about $30kg/m^2s$ by aeration into a loop-seal. Solid circulation rate increases with increasing aeration velocity and it increases further with an auxiliary gas flow into the loop-seal. As solid circulation rate is increased, solid hold up in the riser increases. A typical gas leakage from the riser to the fluidized bed is found to be less than 1%.

The Control System of Wood Pellet Boiler Based on Home Networks (홈 네트워크 기반의 펠릿 활용 난방 보일러 제어시스템)

  • Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • This paper presents the implementation of a control system of pellet boiler using wood pellet as carbon neutral material. The system also has the additional features to provide remote controlling and monitoring based on home networking technology through either public switched telephone networks or mobile communication networks. It consists of three kinds of sub-modules; a main controller provides basic and additional features such as a setting of temperature, a supplying of wood pellet, a controlling of ignition and fire-power, and a removing of soot. The second is temperature controller of individual rooms which is connected to the main controller through RS-485 links. And interface modules with PSTN and mobile networks can support remote controlling and monitoring the functions. The test results under the heating area of $172m^2$ show a thermal efficiency of 93.6%, a heating power of 20,640kcal/hr, and a fuel consumption of 5.54kg/hr. These results are superior to those of the conventional pellet boilers. In order to obtain the such high performance, we newly applied a 3-step ignition flow, a flame detection by $C_dS$ sensor, and a fire-power control by fine controlling of shutter to our pellet boiler.

Holocene Climate Optimum and environmental changes in the Paju and the Cheollipo areas of Korea (한반도 홀로세 온난기후 최적기 (Holocene Climate Optimum)와 지표환경 변화)

  • Nahm, Wook-Hyun;Lim, Jae-Soo
    • The Korean Journal of Quaternary Research
    • /
    • v.25 no.1
    • /
    • pp.15-30
    • /
    • 2011
  • Three sediment cores from two different locations (UJ-03 and UJ-12 cores of valley sediment in Paju area, and CL-4 core of wetland sediment in Cheollipo area) along the western Korean Peninsula yield crucial information on the timing and spatial pattern of century-scale climate changes and subsequent surficial responses during the Holocene. In Paju area, the sediments included abundant coarse-grained sediment (coarse sands and pebbles) from 7100 to 5000 cal. yrBP, total organic carbon (TOC) values showed a marked increase from 5000 to 2200 cal. yrBP, several intermittent depositional layers were observed from 2200 cal. yrBP. In Cheollipo area, lake environment developed from 7360 to 5000 cal. yrBP, the deposition of organic materials increased from 5000 to 2600 cal. yrBP, peatland formed from 2600 cal. yrBP. The two patterns of surficial responses to the climate changes through the Holocene are different to each other. This might be due to the dissimilarity in geomorphic conditions. However, the approximate simultaneity of environmental changes in two areas shows that they both can be correlated to the major climate changes. Two areas which have undergone significant changes indicated that the hydrological factors including precipitation and strength of water flow were most responsible for the landscape and geomorphic evolutions. Although the upwards trend in relative sea-level also played a primary role for environmental changes in coastal area (Cheollipo area), detailed studies have still to be undertaken.

  • PDF

Analysis of the Factors Affecting Nutrients Removal in Hybrid Constructed Wetland Treating Stormwater Runoff (강우 유출수 처리를 위한 하이브리드 인공습지의 영양물질 저감 인자 분석)

  • Gurung, Sher Bahadur;Geronimo, Franz Kevin F.;Choi, Hyeseon;Hong, Jungsun;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.54-62
    • /
    • 2018
  • Nutrients generated from various land uses lead to eutrophication during the influx of water, and it is necessary to apply the LID techniques to reduce nutrients from nonpoint sources in order to mitigate the occurrence of the algal bloom. This study was carried out to derive the design factors of hybrid artificial wetland (HCW) to increase the removal efficiency of nutrients. HCW system was constructed in the year 2010 for the treatment of rainfall runoffs from parking lots and roads composed of 100% impervious floors in the Cheonan campus of Kongju University. The average nutrients removal efficiency of TN and TP was 74% and 72%, respectively. Both TN and TP removal efficiencies were higher than those of free surface wetlands and subsurface flow wetlands due to activated physical and ecological mechanisms. The critical design parameters for the efficient nutrients removal in the artificial wetlands were the ratio of the surface area to the catchment area (SA/CA), land use, the rainfall runoff, and the rainfall intensity. The optimal carbon to nitrogen (C/N) ratio was estimated at 5: 1 to 10.3: 1. The results of this study can be applied to the efficient design of hybrid artificial wetlands to treat nutrients in urban runoff with high efficiency.

Evaporation Heat Transfer Characteristics of Carbon Dioxide in a Diameter Tube of 4.57mm (내경 4.57mm 관내 CO2의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.574-579
    • /
    • 2008
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 4.57mm. The experiments were conducted at mass flux of 400 to $900kg/m^2s$, saturation temperature of 5 to $20^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much. In comparison with test results and existing correlations, All of the existing correlations for the heat transfer coefficient underestimated the experimental data. However Jung et al.'s correlation showed a good agreement with the experimental data. Therefore, it is necessary to develope accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in horizontal tubes.

Measurements and Calculation of Injection Mass Rate of LFG for Intake Injection in Spark Ignition Engines (불꽃점화 엔진의 흡기관 분사를 위한 매립지가스 분사량의 측정 및 계산)

  • Kim, Kyoungsu;Choi, Kyungho;Jeon, Wonil;Kim, Bada;Lee, Daeyup
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.36-42
    • /
    • 2021
  • When the landfill gas generated at the landfill site is released into the atmosphere, methane gas with a high global warming potential is emitted, which adversely affects climate change. When methane contained in landfill gas is used as fuel for internal combustion engines and burned to generate electricity, it is emitted into the atmosphere in the form of carbon dioxide, which can contribute to lowering the global warming potential. Therefore, in order to use the landfill gas as fuel for power generation using an internal combustion engine, it is important to increase the thermal efficiency of the engine. Thus, it is necessary to use a fuel supply system in which gas is injected using an electronically controlled injector at an intake port for each cylinder rather than a fuel supply technology using the conventional mixer technology. In order to use the electronically controlled gas injection method, it is important to accurately measure the mass flow rate according to the conditions of using landfill gas. For this, a study was conducted to measure the injection amount and calculate them in order for the intake port gas injection of landfill gas.

Anthracite Oxygen Combustion Simulation in 0.1MWth Circulating Fluidized Bed (0.1 MWth 급 순환유동층에서의 무연탄 연소 전산유체역학 모사)

  • Go, Eun Sol;Kook, Jin Woo;Seo, Kwang Won;Seo, Su Been;Kim, Hyung Woo;Kang, Seo Yeong;Lee, See Hoon
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.417-428
    • /
    • 2021
  • The combustion characteristics of anthracite, which follow a complex process with low reactivity, must be considered through the dynamic behavior of circulating fluidized bed (CFB) boilers. In this study, computational fluid dynamics (CFD) simulation was performed to analyze the combustion characteristics of anthracite in a pilot scale 0.1 MWth Oxy-fuel circulating fluidized bed (Oxy-CFB) boiler. The 0.1MWth Oxy-CFB boiler is composed of combustor (0.15 m l.D., 10 m High), cyclone, return leg, and so on. To perform CFD analysis, a 3D simulation model reactor was designed and used. The anthracite used in the experiment has an average particle size of 1,070 ㎛ and a density of 2,326 kg/m3. The flow pattern of gas-solids inside the reactor according to the change of combustion environment from air combustion to oxygen combustion was investigated. At this time, it was found that the temperature distribution in air combustion and oxygen combustion showed a similar pattern, but the pressure distribution was lower in oxygen combustion. addition, since it has a higher CO2 concentration in oxygen combustion than in air combustion, it can be expected that carbon dioxide capture will take place actively. As a result, it was confirmed that this study can contribute to the optimized design and operation of a circulating fluidized bed reactor using anthracite.