• 제목/요약/키워드: Carbon fiber reinforced polymer (CFRP)

검색결과 260건 처리시간 0.032초

Static strengths of preloaded circular hollow section stub columns strengthened with carbon fiber reinforced polymer

  • Chen Wei;Yongbo Shao;Mostafa Fahmi Hassanein;Chuannan Xiong;Hongmei Zhu
    • Steel and Composite Structures
    • /
    • 제47권4호
    • /
    • pp.455-466
    • /
    • 2023
  • To investigate the load bearing capacity of axially preloaded circular hollow section (CHS) stub columns strengthened by carbon fiber reinforced polymer (CFRP), theoretical analysis is carried out. The yield strength and the ultimate strength of a CFRP strengthened preloaded CHS stub column are determined at the yielding of the CHS tube and at the CFRP fracture, respectively. Theoretical models are proposed and corresponding equations for calculating the static strengths, including the yield strength and the ultimate strength, are presented. Through comparison with reported experimental results, the theoretical predictions on the static strengths are proved to be accurate. Through finite element (FE) analyses, parametric studies for 258 models of CFRP strengthened preloaded CHS stub columns are conducted by considering different values of tube diameter, tube thickness, CFRP layer and preloading level. The static strengths of the 258 models predicted from presented equations are proved to be in good agreement with FE simulations when the diameter-to-thickness ratio is less than 90ε2. The parametric study indicates that the diameter and the thickness of the steel tube have great effects on CFRP strengthening efficiency, and the recommended ranges of the diameter and the thickness are proposed.

탄소섬유쉬트로 보강된 RC보의 휨 부착성능 (Flexural Adhesive Performance of RC Beams Strengthened by Carbon Fiber Sheets)

  • 유영찬;최기선;최근도;김긍환;이한승
    • 콘크리트학회논문집
    • /
    • 제14권4호
    • /
    • pp.549-555
    • /
    • 2002
  • 탄소섬유쉬트는 철근의 약 10배에 달하는 인장강도를 지니고 있으나, 보강 특성상 접착제를 사용한 일체화가 선행되어져야하기 때문에 부착으로 인한 강도저감요인을 배제할 수가 없다. 결국 탄소섬유쉬트의 인장강도를 최대한 발휘하기 위해서는 부착파괴를 방지할 수 있는 합리적 설계가 이루어져야 한다. 현재까지 부착성능과 관련한 많은 연구가 진행되었지만 부착길이 결정하는 부착강도에 대한 연구는 미흡하였으며, 설계에 반영할 수 있는 기준 역시 미진한 상태이다. 본 연구에서는 일본 규준 안 및 국내 제조사가 제시하고 있는 설계용 부착강도를 기준으로 부착길이를 검토하였으며, 부착성능에 영향을 미칠 젓으로 판단되는 프라이머 도포량 및 에폭시 강도를 변수로 실험을 실시하였다. 본 실험결과에 의하면, 현재 적용 강도는 모두 안전측으로 나타났으며, 설계용 부착강도는 최대 $\tau$a =8 kgf/$\textrm{cm}^2$ 까지 가능할 것으로 판단된다.

Creation of regression analysis for estimation of carbon fiber reinforced polymer-steel bond strength

  • Xiaomei Sun;Xiaolei Dong;Weiling Teng;Lili Wang;Ebrahim Hassankhani
    • Steel and Composite Structures
    • /
    • 제51권5호
    • /
    • pp.509-527
    • /
    • 2024
  • Bonding carbon fiber-reinforced polymer (CFRP) laminates have been extensively employed in the restoration of steel constructions. In addition to the mechanical properties of the CFRP, the bond strength (PU) between the CFRP and steel is often important in the eventual strengthened performance. Nonetheless, the bond behavior of the CFRP-steel (CS) interface is exceedingly complicated, with multiple failure causes, giving the PU challenging to forecast, and the CFRP-enhanced steel structure is unsteady. In just this case, appropriate methods were established by hybridized Random Forests (RF) and support vector regression (SVR) approaches on assembled CS single-shear experiment data to foresee the PU of CS, in which a recently established optimization algorithm named Aquila optimizer (AO) was used to tune the RF and SVR hyperparameters. In summary, the practical novelty of the article lies in its development of a reliable and efficient method for predicting bond strength at the CS interface, which has significant implications for structural rehabilitation, design optimization, risk mitigation, cost savings, and decision support in engineering practice. Moreover, the Fourier Amplitude Sensitivity Test was performed to depict each parameter's impact on the target. The order of parameter importance was tc> Lc > EA > tA > Ec > bc > fc > fA from largest to smallest by 0.9345 > 0.8562 > 0.79354 > 0.7289 > 0.6531 > 0.5718 > 0.4307 > 0.3657. In three training, testing, and all data phases, the superiority of AO - RF with respect to AO - SVR and MARS was obvious. In the training stage, the values of R2 and VAF were slightly similar with a tiny superiority of AO - RF compared to AO - SVR with R2 equal to 0.9977 and VAF equal to 99.772, but large differences with results of MARS.

Effect of FRP parameters in strengthening the tubular joint for offshore structures

  • Prashob, P.S.;Shashikala, A.P.;Somasundaran, T.P.
    • Ocean Systems Engineering
    • /
    • 제8권4호
    • /
    • pp.409-426
    • /
    • 2018
  • This paper presents the strengthening of tubular joint by wrapping Carbon fiber reinforced polymer (CFRP) and glass fiber reinforced polymer (GFRP). In this study, total number of layers, stacking sequence and length of wrapping are the different parameters involved when fiber reinforced polymers (FRP) composites are used for strengthening. For this, parameters where varied and results were compared with the reference joint. The best stacking sequence was identified which has the highest value in ultimate load with lesser deflections. For determining the best stacking sequence, numerical investigation was performed on CFRP composites; length of wrapping and number of layers were fixed. Later, the studies were focused on CFRP and GFRP strengthened joint by varying the total number of layers and length of wrapping. An attempt was done to propose a parametric equation from multiple regression analysis, which can be used for CFRP strengthened joints. Hashin failure criteria was used to check the failure of composites. Results revealed that FRP was having a greater influence in the load bearing capacity of joints, and in reducing the deflections and stresses of joint under axial compressive loads. It was also seen that, CFRP was far better than GFRP in reducing the stresses and deflection.

CFRP로 전단보강된 철근콘크리트 보의 크기효과 (The Size Effect of the Shear Strengths of Reinforced Concrete Beams Strengthened with Carbon FRP)

  • 지광습;김기홍;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.291-294
    • /
    • 2005
  • Presented are the results of recent tests on diagonal shear failure of reinforced concrete beams which are externally reinforced in the transverse direction by a unidirectional carbon fiber reinforced polymer, instead of the traditional steel stirrups. Three different series of the beams with different shear reinforcements, i.e. U-wrapping with carbon sheet, U-wrapping with carbon strips and full wrapping with carbon strips were tested. Those beams were geometrically similar, and the size range is 1:1.9:4. The failure of the beams are characterized by delamination, crushing of concrete and distributed shear cracks. It is found that the size effect is much weaker than that of the reference beams without CFRP. Therefore CFRP sheet may be used as the transverse reinforcement with a minor size effect. However, it is not clear that the same conclusion can be drawn in other sizes. Further researches are recommended.

  • PDF

축방향 인장을 받는 콘크리트 부재의 FRP 보강근의 인장강화 효과 (Tension Stiffening Effect in Axially loaded Concrete Member Oncrete Member)

  • 장낙섭;노치훈;오홍섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.47-54
    • /
    • 2023
  • 본 연구에서는 GFRP, BFRP와 CFRP 보강근으로 보강된 콘크리트 시험체의 인장 거동 특성을 실험적으로 분석하였다. FRP 보강근의 인장강도는 설계강도와 유사하게 나타났으나, 탄성계수는 다소 낮게 측정되었다. 또한 인장강화 시험체는 OPC와 SFRC를 사용하여 150(W)×150(B)×1000(H) mm의 크기로 제작하였다. 균열간격은 탄성계수가 낮고 표면이 보다 매끄러운 GFRP 보강근이 가장 크게 나타났으며, 표면이 다소 거친 BFRP와 탄성계수가 높은 CFRP 보강근의 균열간격은 비슷하게 분석되었다. 하중-변형률관계에서도 GFRP보강근은 균열후 다소 급격한 거동을 보인것에 반하여 BFRP와 CFRP 보강근은 균열발생시 다소 안정적인 거동후 일정수준은 인장강화 효과를 유지하였다. 인장강화지수의 경우 직경이 증가할수록 인장강화지수는 다소 작게 분석되었으며, BFRP보다 GFRP의 경우가 인장강화지수는 높게 분석되었다.

탄소판으로 외부 긴장된 철근콘크리트보의 휨거동에 관한 실험연구 (An Experimental Study on the Flexural Behavior of RC Beams Strengthened with Externally Prestressed CFRP Plate)

  • 박종섭;박영환;유영준;정우태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.72-75
    • /
    • 2004
  • Carbon Fiber Reinforced Polymer(CFRP) composites are widely applied to strengthen deteriorated concrete structures. This paper presents the experimental results of the performance of reinforced concrete(RC) beams strengthened with externally prestressed CFRP plates. Simple beams with 3 m span length were tested to investigate the effect of prestressing force of CFRP plates on the flexural behavior of externally strengthened RC beams.

  • PDF

Characterization of Nonlinear Behaviors of CSCNT/Carbon Fiber-Reinforced Epoxy Laminates

  • Yokozeki, Tomohiro;Iwahori, Yutaka;Ishibashi, Masaru;Yanagisawa, Takashi
    • Advanced Composite Materials
    • /
    • 제18권3호
    • /
    • pp.251-264
    • /
    • 2009
  • Nonlinear mechanical behaviors of unidirectional carbon fiber-reinforced plastic (CFRP) laminates using cup-stacked carbon nanotubes (CSCNTs) dispersed epoxy are evaluated and compared with those of CFRP laminates without CSCNTs. Off-axis compression tests are performed to obtain the stress-strain relations. One-parameter plasticity model is applied to characterize the nonlinear response of unidirectional laminates, and nonlinear behaviors of laminates with and without CSCNTs are compared. Clear improvement in stiffness of off-axis specimens by using CSCNTs is demonstrated, which is considered to contribute the enhancement of the longitudinal compressive strength of unidirectional laminates and compressive strength of multidirectional laminates. Finally, longitudinal compressive strengths are predicted based on a kink band model including the nonlinear responses in order to demonstrate the improvement in longitudinal strength of CFRP by dispersing CSCNTs.

Sprayed FRP 공법에 의한 콘크리트 구조물의 보수.보강법 개발에 관한 연구 - 철근콘크리트 전단기둥의 보강성능 평가 - (Repair and Strengthening Methods for Concrete Structures using Sprayed Fiber Reinforced Polymers - Strengthening performance of Reinforced Concrete Shear Columns -)

  • 이강석;변인희;손영선;이문성;이성호;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.137-140
    • /
    • 2006
  • In this study, a seismic performance of reinforced concrete columns strengthened by a sprayed fiber reinforced polymer (SFRP) is investigated. For this purpose, six column specimens approximately scaled into 2/3, are designed and tested under a constant axial load, 10% of the nominal axial strength of column, and pseudo-static reversed cyclic lateral loading system. Four specimens are strengthened by Sprayed FRP using different combinations of short fibers (carbon or glass fiber) and resins (epoxy or vinyl esther). For comparison, the test investigated in this study also includes a specimen strengthened using carbon fiber reinforced polymer (CFRP), and also a control specimen without strengthening. The results revealed that specimens strengthened using SFRP showed a improved structure behavior, compared to control specimen, in terms of strength, ductility, lateral drift capacity, and energy-absorbtion capacity. In addition, compared to the specimen strengthened using CFRP, Sprayed FRP-strengthened specimens reasonably showed a equivalent seismic performance.

  • PDF

Stress intensity factors for double-edged cracked steel beams strengthened with CFRP plates

  • Wang, Hai-Tao;Wu, Gang;Pan, Yu-Yang;Zakari, Habeeb M.
    • Steel and Composite Structures
    • /
    • 제33권5호
    • /
    • pp.629-640
    • /
    • 2019
  • This paper presents a theoretical and finite element (FE) study on the stress intensity factors of double-edged cracked steel beams strengthened with carbon fiber reinforced polymer (CFRP) plates. By simplifying the tension flange of the steel beam using a steel plate in tension, the solutions obtained for the stress intensity factors of the double-edged cracked steel plate strengthened with CFRP plates were used to evaluate those of the steel beam specimens. The correction factor α1 was modified based on the transformed section method, and an additional correction factor φ was introduced into the expressions. Three-dimensional FE modeling was conducted to calculate the stress intensity factors. Numerous combinations of the specimen geometry, crack length, CFRP thickness and Young's modulus, adhesive thickness and shear modulus were analyzed. The numerical results were used to investigate the variations in the stress intensity factor and the additional correction factor φ. The proposed expressions are a function of applied stress, crack length, the ratio between the crack length and half the width of the tension flange, the stiffness ratio between the CFRP plate and tension flange, adhesive shear modulus and thickness. Finally, the proposed expressions were verified by comparing the theoretical and numerical results.