• Title/Summary/Keyword: Carbon direct-detection

Search Result 27, Processing Time 0.027 seconds

Electrodeposition of Graphene-Zn/Al Layered Double Hydroxide (LDH) Composite for Selective Determination of Hydroquinone

  • Kwon, Yeonji;Hong, Hun-Gi
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1755-1762
    • /
    • 2013
  • A graphene-Zn/Al layered double hydroxide composite film was simultaneously prepared by electrochemical deposition on the surface of a glassy carbon electrode (G-LDH/GCE) from the mixture solution containing GO and nitrate salts of $Zn^{2+}$ and $Al^{3+}$. The modified electrode showed good electrochemical performances toward the simultaneous electrochemical detection of hydroquinone (HQ), catechol (CA) and resorcinol (RE) due to the unique properties of graphene (G) and LDH such as large active surface area, facile electronic transport and high electrocatalytic activity. The redox characteristics of G-LDH/GCE were investigated with cyclic voltammetry and differential pulse voltammetry. The well-separated oxidation peak potentials, corresponding to the oxidation of HQ, CA and RE, were observed at 0.126 V, 0.228 V and 0.620 V respectively. The amperometric response of the modified electrode exhibited that HQ can be detected without interference of CA and RE. Under the optimized conditions, the oxidation peak current of HQ is linear with the concentration of HQ from 6.0 ${\mu}M$ to 325.0 ${\mu}M$ with the detection limit of 0.077 ${\mu}M$ (S/N=3). The modified electrode was successfully applied to the direct determination of HQ in a local tap water, showing reliable recovery data.

Outlier Detection and Treatment for the Conversion of Chemical Oxygen Demand to Total Organic Carbon (화학적산소요구량의 총유기탄소 변환을 위한 이상자료의 탐지와 처리)

  • Cho, Beom Jun;Cho, Hong Yeon;Kim, Sung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.4
    • /
    • pp.207-216
    • /
    • 2014
  • Total organic carbon (TOC) is an important indicator used as an direct biological index in the research field of the marine carbon cycle. It is possible to produce the sufficient TOC estimation data by using the Chemical Oxygen Demand(COD) data because the available TOC data is relatively poor than the COD data. The outlier detection and treatment (removal) should be carried out reasonably and objectively because the equation for a COD-TOC conversion is directly affected the TOC estimation. In this study, it aims to suggest the optimal regression model using the available salinity, COD, and TOC data observed in the Korean coastal zone. The optimal regression model is selected by the comparison and analysis on the changes of data numbers before and after removal, variation coefficients and root mean square (RMS) error of the diverse detection methods of the outlier and influential observations. According to research result, it is shown that a diagnostic case combining SIQR (Semi - Inter-Quartile Range) boxplot and Cook's distance method is most suitable for the outlier detection. The optimal regression function is estimated as the TOC(mg/L) = $0.44{\cdot}COD(mg/L)+1.53$, then determination coefficient is showed a value of 0.47 and RMS error is 0.85 mg/L. The RMS error and the variation coefficients of the leverage values are greatly reduced to the 31% and 80% of the value before the outlier removal condition. The method suggested in this study can provide more appropriate regression curve because the excessive impacts of the outlier frequently included in the COD and TOC monitoring data is removed.

CO Two-photon Laser Induced Fluorescence Measurements in High Temperature and Pressure Conditions (고온고압 조건에서 Two-Photon LIF를 이용한 CO 측정에 관한 연구)

  • Oh, Seung-Mook;Kim, Duk-Sang;Miles, Paul C.;Colban, Will F.
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Carbon monoxide (CO) is not only an important intermediate species in chemical reaction mechanisms of hydrocarbon fuel combustion, but also a crucial pollutant species emitted from automotive engines. To better understand the physical processes impacting CO emissions, the development of laser-based measurement techniques that can visualize in-cylinder CO distributions is desirable. Among these techniques, Laser-Induced Fluorescence (LIF) is a sensitive and species-selective detection technique capable of good spatial resolution. However, some technical matters such as deep UV excitation, severe pressure dependency of the LIF signal, and potential interference from other species have been major challenges for CO LIF application. This study is focused on investigating the feasibility of CO two-photon LIF in a direct-injection diesel engine operating at typical pressure and temperature conditions with commercial grade diesel fuel. Spectroscopic analysis shows that the CO fluorescence signal can be separated from $C_2$ Swan band or broadband fluorescence from PAHs when the signal is collected near 483 nm. The signal-to-noise ratio of CO LIF deteriorate rapidly as pressure is increased, following $P^{-1.49}$ which matches the theoretical signal pressure dependency.

  • PDF

Species Concentration Measurement Using Diode Laser Absorption Spectroscopy (I) (다이오드 레이저를 이용한 광흡수 농도 계측 기법 (I))

  • Ahn, Jae-Hyun;Kim, Yong-Mo;Kim, Se-Won
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, resonable cost, robustness, and ease of use. In addition, diode lasers are fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develope a new gas sensing system and to verify feasibility of this system. Wavelength and power characteristics as a function of injection current and temperature are experimentally found out. Direct absorption spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

Green Synthesis of Platinum Nanoparticles by Electroreduction of a K2PtCl6 Solid-State Precursor and Its Electrocatalytic Effects on H2O2 Reduction

  • Kim, Kyung Tae;Jin, Sung-Ho;Chang, Seung-Cheol;Park, Deog-Su
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3835-3839
    • /
    • 2013
  • A new synthesis route for Pt nanoparticles by direct electrochemical reduction of a solid-state Pt ion precursor ($K_2PtCl_6$) is demonstrated. Solid $K_2PtCl_6$-supported polyethyleneimine (PEI) coatings on the surface of glassy carbon electrode were prepared by simple mixing of solid $K_2PtCl_6$ into a 1.0% PEI solution. The potential cycling or a constant potential in a PBS (pH 7.4) medium were applied to reduce the solid $K_2PtCl_6$ precursor. The reduction of Pt(IV) began at around -0.2 V and the reduction potential was ca. -0.4 V. A steady state current was achieved after 10 potential cycling scans, indicating that continuous formation of Pt nanoparticles by electrochemical reduction occurred for up to 10 cycles. After applying the reduction potential of -0.6 V for 300 s, Pt nanoparticles with diameters ranging from $0.02-0.5{\mu}m$ were observed, with an even distribution over the entire glassy carbon electrode surface. Characteristics of the Pt nanoparticles, including their performance in electrochemical reduction of $H_2O_2$ are examined. A distinct reduction peak observed at about -0.20 V was due to the electrocatalytic reduction of $H_2O_2$ by Pt nanoparticles. From the calibration plot, the linear range for $H_2O_2$ detection was 0.1-2.0 mM and the detection limit for $H_2O_2$ was found to be 0.05 mM.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

Work Environments and Exposure to Hazardous Substances in Korean Tire Manufacturing

  • Lee, Na-Roo;Lee, Byung-Kyu;Jeong, Si-Jeong;Yi, Gwang-Yong;Shin, Jung-Ah
    • Safety and Health at Work
    • /
    • v.3 no.2
    • /
    • pp.130-139
    • /
    • 2012
  • Objectives: The purpose of this study is to evaluate the tire manufacturing work environments extensively and to identify workers' exposure to hazardous substances in various work processes. Methods: Personal air sampling was conducted to measure polycyclic aromatic hydrocarbons, carbon disulfide, 1,3-butadiene, styrene, methyl isobutyl ketone, methylcyclohexane, formaldehyde, sulfur dioxide, and rubber fume in tire manufacturing plants using the National Institute for Occupational Safety Health Manual of Analytical Methods. Noise, carbon monoxide, and heat stress exposure were evaluated using direct reading instruments. Past concentrations of rubber fume were assessed using regression analysis of total particulate data from 2003 to 2007, after identifying the correlation between the concentration of total particulate and rubber fume. Results: Workers were exposed to rubber fume that exceeded 0.6 mg/$m^3$, the maximum exposure limit of the UK, in curing and production management processes. Forty-seven percent of workers were exposed to noise levels exceeding 85 dBA. Workers in the production management process were exposed to $28.1^{\circ}C$ (wet bulb globe temperature value, WBGT value) even when the outdoor atmosphere was $2.7^{\circ}C$ (WBGT value). Exposures to other substances were below the limit of detection or under a tenth of the threshold limit values given by the American Conference of Governmental Industrial Hygienists. Conclusion: To better classify exposure groups and to improve work environments, examining closely at rubber fume components and temperature as risk indicators in tire manufacturing is recommended.

Detection of PED virus by the immunoelectron microscopy and immunogold conjugate immunoelectron microscopy (면역전자현미경(免疫電子顯微鏡)(IEM) 기법(技法) 및 immunogold conjugate 면역전자현미경(免疫電子顯微鏡)(IGC-IEM) 기법(技法)을 이용(利用)한 돼지 분변내 PED 바이러스의 검출(檢出))

  • Kim, Jae-hoon;Hwang, Eui-kyung;Bae, You-chan;Son, Hyun-joo;Park, Jung-won;Yoon, Yong-dhuk
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.3
    • /
    • pp.575-581
    • /
    • 1995
  • Both immunoelectron microscopy(IEM) and immunogold conjugate immunoelectron microscopy (IGC-IEM) techniques were developed for the detection of porcine epidemic diarrhea virus(PEDV) from the feces. Fecal samples were incubated sequentially with anti-PEDV monoclonal antibody(MoAb) and immunogold conjugated goat anti-mouse IgG+IgM. Then negatively stained, mounted on the formvar carbon-coated copper EM grids and observed by the transmission electron microscope. By the direct electron microscopy(DEM), coronavirus particles were observed from 17 cases of total 33 fecal samples of grower pigs and sows. The virons of coronavirus were moderately pleomorphic but mostly spherical, with a diameter ranged from 90 to 190nm. PED virus particles were identified from 15 cases of 17 DEM positive samples by the IEM and IGC-IEM techniques. Aggregates of PED virus coated with specific antibody were seen in fecal samples incubated with homologous anti-PED virus MoAb but not in control samples incubated with anti-TGE virus MoAb. Following incubation with immunogold-conjugated secondary antibody, the gold granules were usually distributed around and among the virus particles and soluble and viral particle-associated antigen. So, IEM and IGC-IEM techniques were proved a rapid and sensitive methods for detection and identification of PED virus from fecal and intestinal contents.

  • PDF

Large Scale Directed Assembly of SWNTs and Nanoparticles for Electronics and Biotechnology

  • Busnaina, Ahmed;Smith, W.L.
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.9-9
    • /
    • 2011
  • The transfer of nano-science accomplishments into technology is severely hindered by a lack of understanding of barriers to nanoscale manufacturing. The NSF Center for High-rate Nanomanufacturing (CHN) is developing tools and processes to conduct fast massive directed assembly of nanoscale elements by controlling the forces required to assemble, detach, and transfer nanoelements at high rates and over large areas. The center has developed templates with nanofeatures to direct the assembly of carbon nanotubes and nanoparticles (down to 10 nm) into nanoscale trenches in a short time (in seconds) and over a large area (measured in inches). The center has demonstrated that nanotemplates can be used to pattern conducting polymers and that the patterned polymer can be transferred onto a second polymer substrate. Recently, a fast and highly scalable process for fabricating interconnects from CMOS and other types of interconnects has been developed using metallic nanoparticles. The particles are precisely assembled into the vias from the suspension and then fused in a room temperature process creating nanoscale interconnect. The center has many applications where the technology has been demonstrated. For example, the nonvolatile memory switches using (SWNTs) or molecules assembled on a wafer level. A new biosensor chip (0.02 $mm^2$) capable of detecting multiple biomarkers simultaneously and can be in vitro and in vivo with a detection limit that's 200 times lower than current technology. The center has developed the fundamental science and engineering platform necessary to manufacture a wide array of applications ranging from electronics, energy, and materials to biotechnology.

  • PDF

Expression and Purification of a Recombinant scFv towards the Exotoxin of the Pathogen, Burkholderia pseudomallei

  • Lim, Kue-Peng;Li, Hong-Bin;Sheila Nathan
    • Journal of Microbiology
    • /
    • v.42 no.2
    • /
    • pp.126-132
    • /
    • 2004
  • A single chain variable fragment (scFv) specific towards B. pseudomallei exotoxin had previously been generated from an existing hybridoma cell line (6E6AF83B) and cloned into the phage display vector pComb3H. In this study, the scFv was subcloned into the pComb3X vector to facilitate the detection and purification of expressed antibodies. Detection was facilitated by the presence of a hemagglutinin (HA) tag, and purification was facilitated by the presence of a histidine tag. The culture was grown at 30$^{\circ}C$ until log phase was achieved and then induced with 1 mM IPTG in the absence of any additional carbon source. Induction was continued at 30$^{\circ}C$ for five h. The scFv was discerned by dual processes-direct enzyme-linked immunosorbent assays (ELISA), and Western blotting. When compared to E. coli strains ER2537 and HB2151, scFv expression was observed to be highest in the E. coli strain Topl0F'. The expressed scFv protein was purified via nickel-mediated affinity chromatography and results indicated that two proteins a 52 kDa protein, and a 30 kDa protein were co-purified. These antibodies, when blotted against immobilized exotoxin, exhibited significant specificity towards the exotoxin, com-pared to other B. pseudomallei antigens. Thus, these antibodies should serve as suitable reagents for future affinity purification of the exotoxin.