• Title/Summary/Keyword: Carbon Zero

Search Result 256, Processing Time 0.032 seconds

Demand Shifting or Ancillary Service?: Optimal Allocation of Storage Resource to Maximize the Efficiency of Power Supply (Demand Shifting or Ancillary Service?: 효율적 재생발전 수용을 위한 에너지저장장치 최적 자원 분배 연구)

  • Wooyoung Jeon
    • Environmental and Resource Economics Review
    • /
    • v.33 no.2
    • /
    • pp.113-133
    • /
    • 2024
  • Variable renewable energy (VRE) such as solar and wind power is the main sources of achieving carbon net zero, but it undermines the stability of power supply due to high variability and uncertainty. Energy storage system (ESS) can not only reduce the curtailment of VRE by load shifting but also contribute to stable power system operation by providing ancillary services. This study analyzes how the allocation of ESS resources between load shifting and ancillary service can contribute to maximizing the efficiency of power supply in a situation where the problems caused by VRE are becoming more and more serious. A stochastic power system optimization model that can realistically simulate the variability and uncertainty of VRE was applied. The analysis time point was set to 2023 and 2036, and the optimal resource allocation strategy and benefits of ESS by varying VRE penetration levels were analyzed. The analysis results can be largely summarized into the following three. First, ESS provides excellent functions for both load shifting and ancillary service, and it was confirmed that the higher the reserve price, the more limited the load shifting and focused on providing reserve. Second, the curtailment of VRE can be a effective substitute for the required reserve, and the higher the reserve price level, the higher the curtailment of VRE and the lower the required amount of reserve. Third, if a reasonable reserve offer price reflecting the opportunity cost is applied, ESS can secure economic feasibility in the near future, and the higher the proportion of VRE, the greater the economic feasibility of ESS. This study suggests that cost-effective low-carbon transition in the power system is possible when the price signal is correctly designed so that power supply resources can be efficiently utilized.

Synthesis of Graphene on Hexagonal Boron Nitride by Low Pressure Chemical Vapor

  • Han, Jae-Hyun;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.391-392
    • /
    • 2012
  • Graphene is a perfectly two-dimensional (2D) atomic crystal which consists of sp2 bonded carbon atoms like a honeycomb lattice. With its unique structure, graphene provides outstanding electrical, mechanical, and optical properties, thus enabling wide variety of applications including a strong potential to extend the technology beyond the conventional Si based electronic materials. Currently, the widespread application for electrostatically switchable devices is limited by its characteristic of zero-energy gap and complex process in its synthesis. Several groups have investigated nanoribbon, strained, or nanomeshed graphenes to induce a band gap. Among various techniques to synthesize graphene, chemical vapor deposition (CVD) is suited to make relatively large scale growth of graphene layers. Direct growth of graphene on hexagonal boron nitride (h-BN) using CVD has gained much attention as the atomically smooth surface, relatively small lattice mismatch (~1.7%) of h-BN provides good quality graphene with high mobility. In addition, induced band gap of graphene on h-BN has been demonstrated to a meaningful value about ~0.5 eV.[1] In this paper, we report the synthesis of grpahene / h-BN bilayer in a chemical vapor deposition (CVD) process by controlling the gas flux ratio and deposition rate with temperature. The h-BN (99.99%) substrate, pure Ar as carrier gas, and $CH_4$ are used to grow graphene. The number of graphene layer grown on the h-BN tends to be proportional to growth time and $CH_4$ gas flow rate. Epitaxially grown graphene on h-BN are characterized by scanning electron microscopy, atomic force microscopy, and Raman spectroscopy.

  • PDF

Stability and dynamic analyses of SW-CNT reinforced concrete beam resting on elastic-foundation

  • Bourada, Fouad;Bousahla, Abdelmoumen Anis;Tounsi, Abdeldjebbar;Bedia, E.A. Adda;Mahmoud, S.R.;Benrahou, Kouider Halim;Tounsi, Abdelouahed
    • Computers and Concrete
    • /
    • v.25 no.6
    • /
    • pp.485-495
    • /
    • 2020
  • This paper, presents the dynamic and stability analysis of the simply supported single walled Carbon Nanotubes (SWCNT) reinforced concrete beam on elastic-foundation using an integral first-order shear deformation beam theory. The condition of the zero shear-stress on the free surfaces of the beam is ensured by the introduction of the shear correction factors. The SWCNT reinforcement is considered to be uniform and variable according to the X, O and V forms through the thickness of the concrete beam. The effective properties of the reinforced concrete beam are calculated by employing the rule of mixture. The analytical solutions of the buckling and free vibrational behaviors are derived via Hamilton's principle and Navier method. The analytical results of the critical buckling loads and frequency parameters of the SWCNT-RC beam are presented in the form of explicit tables and graphs. Also the diverse parameters influencing the dynamic and stability behaviors of the reinforced concrete beam are discussed in detail.

Degradation of PAHs in Aqueous Solution by UV Energy and Ultrasonic Irradiation (액상 PAHs의 자외선에너지와 초음파를 이용한 분해)

  • Kwon Sung-Hyun;Kim Jong-Hyang;Cho Dae-Chul
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.669-676
    • /
    • 2006
  • PAHs are major pollutants that are widely distributed in soil and groundwater environment, so that may be regarded as carcinogens. We investigated the degradation kinetics of PAH in aqueous solution when low pressure UV energy and ultrasonic irradiation were applied. Phenanthrene and pyrene were used as model compounds. The degrees of degradation of these compounds with time were analyzed with a GC/MSD (SIM-mode). UV photolysis experiments showed that phenanthrene was reduced by 90 -67% at initial concentrations of 1 ppm to 8ppm whilst it decreased to 50% at 10 ppm. Under the same conditions pyrene was degraded up to about 75% at lower initial concentrations but the reduction efficiency dropped to a level of 34 to 29% at the higher concentrations above 8 ppm. The reaction orders for phenanthrene and pyrene were found to be zero-th and ca. -0.4th order, respectively, thus implying that the reported assumption of pseudo 1st order reaction for some PAHs would be no longer valid. PAH degradation was roughly proportional to the intensity of UV (number of lamps), exhibiting maximum 92.5% of the degradation efficiency. The solution pH was lowered to 4.4 from 6.4 during the experiments partially because the carbons decomposed by the energy reacted with oxygen radicals to produce carbon dioxides. Ultrasonic irradiation on phenanthrene solutions gave relatively poor results which matched to 50 to 70% of degradation efficiency even at 2 ppm of initial concentration. Phenanthrene was found to be degraded more efficiently than pyrene for the two energy sources. Ultrasound also followed the same reaction kinetics as UV energy on PAH degradation.

Analysis of dominant impurities in Cu and Ta films using SIMS and GDMS (SIMS와 GDMS를 이용한 구리와 탄탈 박막내의 주요불순물 분석)

  • ;Minoru Isshiki
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Secondary ion mass spectrometry(SIMS) and glow discharge mass spectrometry(GDMS) were used to determine the impurity concentrations of hydrogen, carbon, and oxygen elements in the Cu and Ta films, and the results of SIMS and GDMS analysis were carefully considered. The Cu and Ta films were deposited on Si (100) substrates at zero substrate bias voltage and a substrate bias voltage of -50 V(Cu films) or -125 V(Ta films) using a non-mass separated ion beam deposition method. As a result of SIMS with Cs+ ion beam, in the case of the Cu and Ta films deposited without the substrate bias voltage, many strong peaks were observed, which is considered to be detected as a the cluster state such as CxHx, OxHx, CxOxHx. All the peaks of SIMS results could be interpreted by the combination of these dominant impurities. Moreover, it was confirmed that the quantitative results of GDMS analysis were accordant to the SIMS results.

Butane Working Capacity Evaluation of HC Adsorption Filter for Evaporative Gas to Satisfy PZEV Regulation (PZEV 대응 증발가스 흡착필터의 부탄 흡탈착 능력 평가)

  • Kim, Deok-Jung;Lee, Gee-Soo;Kim, Hyun-Chul;Heo, Hyung-Seok;Na, Byung-Chul;Choi, Seung-Bae;Ra, Wan-Yong;Cho, Yong-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.4
    • /
    • pp.133-138
    • /
    • 2009
  • The continued rise in the number of automobiles on the roads is prompting air pollution to emerge as a serious problem due to the harmful exhaust gas emissions throughout the world. Specifically, based on the exhaust gas regulation in North America represented by PZEV, the regulation on evaporative emission, which originates from the intake manifold system when the engine is stopped, is substantially being intensified. And the technology that can meet and satisfy these regulations has been needed. This study aimed to analyze and evaluate the butane working capacity (BWC) of HC adsorption filter according to the shape of it, which was developed to reduce evaporative emission, and the effect of HC adsorption filter on the engine performance. As a results, HC adsorption filter of the plate type, which was improved compared to that of the corrugated type and also became thinner, indicates higher absorption performance compared to the corrugated one. The absorption performance of the honeycomb type, derived from improving the shape of plate type, is 33.5% higher than that of the corrugated type. However, there was no significant difference in engine performance in all shapes.

CAH degradation characteristics under mixed conditions (혼합조건에서의 CAH 화합물 분해 특성에 관한 연구)

  • 김종호;배우근;심호재;신언빈
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.214-217
    • /
    • 2001
  • 자연계에서는 오염물질이 단일물질로 존재하기보다는 혼합물로 존재하는 것이 대부분이다. 본 연구에서는 지하수 오염물질 chlorinated aliphatic hydrocarbon(CAH)들 중 trichloroethylene(TCE), vinyl chloride(VC)에 대해서 Fe$^{\circ}$와 함께 미생물, 활성탄을 이용하여 단일물질 및 혼합물질상태에서 그 분해특성을 살펴보았다. 실험은 120$m\ell$ serum bottle을 이용하여 단일물질 및 혼합물질상태에서 그 분해특성을 살펴보았다. 실험은 120$m\ell$ serum bottle을 이용하였고 headspace 50${\mu}\ell$를 GC에 주입하여 각 오염물질 농도를 분석하였으며, Fe$^{\circ}$, Fe$^{\circ}$+ cell, Fe$^{\circ}$+ 활성탄 3가지 조건에서 TCE (25${\mu}\ell$)가 단일화합물 또는 VC(10$\mu\textrm{m}$)와 혼합화학물로 존재시 분해특성을 조사하였다. 단일화합물로 존재시 2시간후 TCE농도 측정 결과 Fe$^{\circ}$만을 이용하였을 때보다 활성탄, Cell을 함께 이용하였을 경우 그 분해율이 각각 1.6배, 1.8배 높게 나타났다. 그러나, VC와 혼화합물로 존재시 TCE 분해율은 단일 화합물로 존재시와 비교 Fe$^{\circ}$, Fe$^{\circ}$+ 활성탄, Fe$^{\circ}$+ cell 조건에서 각각 63%, 28%, 5%로 나타났다. VC는 Fe$^{\circ}$만으로는 분해가 되지 않았지만 cell에 의해 완전분해 되었으며, 함께 존재시 TC는 Fe$^{\circ}$만으로는 분해가 되지 않았지만 cell에 의해 완전분해 되었으며, 함께 존재시 TCE분해에 저해작용을 미치는 것으로 나타났다.

  • PDF

A Study on the Optimal Resource Configuration Considering Load Characteristics of Electric Vehicles in Micro Grid Environment (전기자동차 부하 특성을 고려한 마이크로그리드의 최적 전원 구성에 관한 연구)

  • Hwang, Sung-Wook;Chae, Woo-Kyu;Lee, Hak-Ju;Yun, Sang-Yun;Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.228-231
    • /
    • 2015
  • In power system research fields, one of current key issues is the construction and commercialization of micro grid site which is called green island, carbon zero island, energy independent island, building micro grid, etc. and various affiliated technologies have been being vigorously developed to realize. In addition, various researches about electric vehicles (EVs) are in progress and it is expected to penetrate rapidly with the next a few years. Some new load models should be developed integrating with electric vehicle loads because the EVs' deployment could cause the change of load composition rate on power system planning and operations. EVs are also resources for micro grid as well as distributed generation and demand response so that various supply and demand side resources should be considered for micro grid researches. In this paper, the load composition rate of residential sectors is prospected considering the deployment of EVs and the resource configuration of micro grid is optimized based on net present cost. In the optimization, the load patten of case studies includes EV's charging characteristics and various cases are simulated comparing micro grid environment and normal condition. HOMER is used to compare various cases and economic effects.

Urinary Trans, Trans-Muconic Acid is Not a Reliable Biomarker for Low-level Environmental and Occupational Benzene Exposures

  • Jalai, Amir;Ramezani, Zahra;Ebrahim, Karim
    • Safety and Health at Work
    • /
    • v.8 no.2
    • /
    • pp.220-225
    • /
    • 2017
  • Background: Benzene is a known occupational and environmental pollutant. Its urinary metabolite trans, trans-muconic acid (tt-MA) has been introduced by some environmental and occupational health regulatory associations as a biological index for the assessment of benzene exposure; however, recently, doubts have been raised about the specificity of tt-MA for low-level benzene exposures. In the present study, we investigated the association between urinary levels of tt-MA and inhalational exposure to benzene in different exposure groups. Methods: Benzene exposure was assessed by personal air sampling. Collected benzene on charcoal tube was extracted by carbon disulfide and determined by a gas chromatograph (gas chromatography with a flame ionization detector). Urinary tt-MA was extracted by a strong anion-exchange column and determined with high-performance liquid chromatography-UV. Results: Urinary levels of tt-MA in intensive benzene exposure groups (chemical workers and police officers) were significantly higher than other groups (urban and rural residents), but its levels in the last two groups with significant different exposure levels (mean = 0.081 ppm and 0.019 ppm, respectively) showed no significant difference (mean = $388{\mu}g/g$ creatinine and $282{\mu}g/g$, respectively; p < 0.05). Before work shift, urine samples of workers and police officers showed a high amount of tt-MA and its levels in rural residents' samples were not zero. Conclusion: Our results suggest that tt-MA may not be a reliable biomarker for monitoring low-level (below 0.5 ppm) benzene exposures.

Design Analysis/Manufacturing /Performance Evaluation of Curved Unsymmetrical Piezoelectric Composite Actuator LIPCA (곡면형 비대칭 압전복합재료 작동기 LIPCA의 설계해석/제작/성능평가)

  • Gu, Nam-Seo;Sin, Seok-Jun;Park, Hun-Cheol;Yun, Gwang-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1514-1519
    • /
    • 2001
  • This paper is concerned with design, manufacturing and performance test of LIPCA ( Lightweight Piezo- composite Curved Actuator) using a top carbon fiber composite layer with near -zero CTE(coefficient of thermal expansion), a middle PZT ceramic wafer and a bottom glass/epoxy layer with high CTE. The main point of this design is to replace the heavy metal layers of THUNDER by thigh tweight fiber reinforced plastic layers without losing capabilities to generate high force and large displacement. It is possible to save weight up to about 30% if we replace the metallic backing material by the light fiber composite layer. We can also have design flexibility by selecting the fiber direction and the size of prepreg layers. In addition to the lightweight advantage and design flexibility, the proposed device can be manufactured without adhesive layers when we use epoxy resin prepreg system. Glass/epoxy prepregs, a ceramic wafer with electrode surfaces, and a graphite/epoxy prepreg were simply stacked and cured at an elevated temperature (177 $^{circ}C$ after following an autoclave bagging process. It was found that the manufactured composite laminate device had a sufficient curvature after detached from a flat mold. The analysis method of the cure curvature of LIPCA using the classical lamination theory is presented. The predicted curvatures are fairly in agreement with the experimental ones. In order to investigate the merits of LIPCA, a performance test of both LIPCA and THUNDE$^{TM}$ were conducted under the same boundary conditions. From the experimental actuation tests, it was observed that the developed actuator could generate larger actuation displacement than THUNDERT$^{TM}$.