• 제목/요약/키워드: Capsule endoscopes

검색결과 20건 처리시간 0.094초

A Paddling Based Locomotive Mechanism for Capsule Endoscopes

  • Park Suk-Ho;Park Hyun-Jun;Park Sung-Jin;Kim Byung-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • 제20권7호
    • /
    • pp.1012-1018
    • /
    • 2006
  • Diagnosis and treatment using the conventional flexible endoscope in gastro-intestinal tract are very common since advanced and instrumented endoscopes allow diagnosis and treatment by introducing the human body through natural orifices. However, the operation of endoscope is very labor intensive work and gives patients some pains. As an alternative, therefore, the capsule endoscope is developed for the diagnosis of digestive organs. Although the capsule endoscope has conveniences for diagnosis, it is passively moved by the peristaltic waves of gastro-intestinal tract and thus has some limitations for doctor to get the image of the organ and to diagnose more thoroughly. As a solution of these problems, various locomotive mechanisms for capsule endoscopes are introduced. In our proposed mechanism, the capsule-type microrobot has synchronized multiple legs that are actuated by a linear actuator and two mobile cylinders inside of the capsule. For the feasibility test of the proposed microrobot, a series of in-vitro experiments using small intestine without incision were carried out. From the experimental results, our proposed microrobot can advance along the 3D curved and sloped path with the velocity of about $3.29\sim6.26mm/sec$ and $35.1\sim66.7%$ of theoretical velocity. Finally, the proposed locomotive mechanism can be not only applicable to micro capsule endoscopes but also effective to advance inside of gastro-intestinal tract.

Design and Implementation of the RF Systems for Bi-directional Wireless Capsule Endoscopes

  • Moon, Yeon-Kwan;Lee, Jyung-Hyun;Park, Hee-Joon;Lee, Ju-Gab;Ryu, Jae-Jong;Lee, Wu-Seong;Woo, Sang-Hyo;Won, Chul-Ho;Cho, Jin-Ho;Choi, Hyun-Chul
    • 한국멀티미디어학회논문지
    • /
    • 제9권12호
    • /
    • pp.1669-1680
    • /
    • 2006
  • This paper explains that the RF systems for hi-directional wireless capsule endoscopes were designed and implemented. The designed RF systems for a capsule endoscope can transmit the images of intestines from the inside to the outside of a body and the behavior of the capsules can be controlled by an external controller simultaneously. The hi-directional wireless capsule endoscope consists of a CMOS image sensor, FPGA, LED, battery, DC to DC Converter, transmitter, receiver, and antennas. The transmitter and receiver which were used in the hi-directional capsule endoscope, were designed and fabricated with $10mm(diameter){\times}3.2mm(thickness)$ dimensions taking into the MPE, power consumption, system size, signal to noise ratio and modulation method. The RF systems designed and implemented for the hi-directional wireless capsule endoscopes system were verified by in-vivo experiments. As a result, the RF systems for the hi-directional wireless capsule endoscopes satisfied the design specifications.

  • PDF

캡슐형 내시경 구동을 위한 무선 에너지 전송 (A Wireless Energy Transmission For Capsule Endoscopes)

  • 서민성;고영석;박시홍
    • 전자공학회논문지SC
    • /
    • 제45권3호
    • /
    • pp.80-85
    • /
    • 2008
  • 기존의 캡슐형 내시경은 공간적 제약으로 인해 약 30mW 용량의 1차 전지를 사용한다. 그러나 1차 전지를 사용하는 방식은 배터리 용량의 한계와 1회용 소모품으로 가격이 비싸다. 이러한 문제를 해결하기 위해 신체 외부에서 캡슐형 내시경에 무선으로 에너지를 전송 방식을 제안하였다. 제안된 방식은 송 수신측 양단에 LC공진 회로를 이용하여 $10{\sim}20cm$의 공극을 통해 송신측 코일에서 캡슐형 내시경으로 에너지를 전달하는 방식이다. 위치와 방향성에 상관없이 에너지 효율의 증가를 위해 수신측 코일은 페라이트 코어를 이용한 3축 권선 방식을 이용하였다. 실험에 의한 측정 결과 제안된 방식은 수신측 회로에 안정적으로 30mW의 전력을 공급할 수 있음을 확인하였다.

PZT 구동기를 이용한 지렁이 이동방식의 캡슐형 내시경용 마이크로 로봇 (An Earthworm-Like Locomotive Mechanism for Capsule Endoscopes Using PZT Actuator)

  • 지창열;박석호;윤석진;김병규;박장현
    • 대한기계학회논문집A
    • /
    • 제30권1호
    • /
    • pp.84-89
    • /
    • 2006
  • A wireless capsule endoscope has been developed to replace the conventional endoscope. However, the commercialized capsule endoscope moves passively by peristaltic waves, which has some limitations for doctors to diagnose more thoroughly and actively. In order to solve this problem, a locomotive mechanism is proposed for wireless capsule endoscopes. Based on the tests of various actuators, a piezo actuator is selected as a micro actuator for capsule endoscope. In general, piezo actuators are known to have limited displacement with high voltage supply. In order to overcome the limitation of common piezo actuator, the impact based piezo actuator, is developed to realize long stroke up 11mm. By using the impact based piezo actuator, a prototype of an earthworm-like locomotive mechanism was developed. In addition, the proposed locomotive mechanism has engraved clamps mimicked the claw of an insect. The earthworm-like locomotive mechanism has 15 mm in diameter and 30mm under retraction stage and 41 mm under elongation stage in total length. Hollow space is allocated to comprise essential endoscope components such as a camera, a communication module, bio sensors, and a battery. For the feasibility test of proposed locomotive mechanism, a series of experiments were carried out including in-vitro tests. Based on results of the experiments, we conclude that the proposed locomotive mechanism is effective to be used for micro capsule endoscopes.

캡슐형 내시경을 위한 체내 이동용 마이크로 로봇 (Locomotive Microrobot for Capsule Endoscopes)

  • 양성욱;박기태;이승석;나경환;김진석;최종호;박석호;박종오;윤의성
    • 로봇학회논문지
    • /
    • 제4권1호
    • /
    • pp.62-67
    • /
    • 2009
  • For diagnoses of digestive organs, capsule endoscopes are widely used and offer valuable information without patient's discomfort. A general capsule endoscope which consists of image sensing module, telemetry module and battery is able to move along gastro-intestinal tracts passively only through peristaltic waves. Thus, it is likely to have some limitations for doctor to acquire images from the desired organs and to diagnose them effectively. As solutions to these problems, a locomotive function of capsule endoscopes has being developed. We have proposed a capsule-type microrobot with synchronized multiple legs. However, the proposed capsular microrobot also has some limitations, such as low speed in advancement, inconvenience to controlling the microrobot, lack of an image module, and deficiency in a steering module. In this paper, we will describe the limitations of the locomotive microrobot and propose solutions to the drawbacks. The solutions are applied to the capsular microrobot and evaluated by in-vitro tests. Based on the experimental results, we conclude that the proposed solutions are effective and appropriate for the locomotive microrobot to explore inside intestinal tracts.

  • PDF

Magnetic Actuator for a Capsule Endoscope Navigation System

  • Chiba, Atsushi;Sendoh, Masahiko;Ishiyama, Kazushi;Arai, Ken Ichi;Kawano, Hironao;Uchiyama, Akio;Takizawa, Hironobu
    • Journal of Magnetics
    • /
    • 제12권2호
    • /
    • pp.89-92
    • /
    • 2007
  • The authors propose a magnetic actuator for use as a navigation system for capsule endoscopes. The actuator is composed of a capsule dummy, a permanent magnet inside the capsule, and an external spiral structure. The device rotates and propels wirelessly when exposed to an external rotational magnetic field. In this study we measured the effect of the spiral shape on the velocity and thrust force properties. According to our experimental results, the actuator obtained a maximum velocity and thrust force when the spiral angle was set at 45 degrees, the number of spirals was set at 4, and the spiral-height was set at 1-mmf. We also conducted a motion test in the large intestine of a pig placed on a 30 degrees slope. The actuator passed through a 700 mm length of the intestine in about 300 s. The device also managed to travel up and down the 30 degrees slope with no difficulty whatsoever. Our results demonstrate the great potential of this actuator for use as a navigation system for capsule endoscopes.

SMA를 이용한 캡슐 내시경의 이동메커니즘 설계 및 제작 (Design and fabrication of the Locomotive Mechanism for Capsule Endoscopes Using Shape Memory Alloys (SMA))

  • 이승학;김병규;박종현;박종오
    • 대한기계학회논문집A
    • /
    • 제27권11호
    • /
    • pp.1849-1855
    • /
    • 2003
  • Newly commercialized wireless capsule endoscope has many advantages compared to conventional push-type endoscopes. However, it is moved by the peristaltic waves. Therefore, it can not diagnose desired zones actively. In this paper, a locomotive mechanism for wireless capsule endoscope is proposed to increase the efficiency of endoscopy. We designed and fabricated a prototype using SMA springs and bio-mimetic clamping device. The hollow space in the prototype is allocated for further system integration of a camera module, a RF module and a battery. And the sequential control scheme is employed to improve the efficiency of its locomotion. To validate the performance of the locomotive mechanism, experiments on a silicone rubber pad and in vitro tests are carried out. The results of the experiments indicate that proposed mechanism is effective in harsh environments such as digestive organs of a human.

디더운동이 캡슐형 내시경의 마찰계수 감소에 미치는 영향 (Influence of Dither Motion on the Friction Coefficient of a Capsule-type Endoscope)

  • 홍예선;최일수;김병규
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.57-63
    • /
    • 2005
  • Development of a locomotive mechanism fer the capsule type endoscopes will largely enhance the ability to diagnose disease of digestive organs. In connection with it, most of researches have focused on an installable locomotive mechanism in the capsule. In this paper, it is introduced that the movement of a capsule type endoscope in digestive organ can be manipulated by magnetic force produced outside human body. Since the magnetic force is provided by permanent magnets, no additional power supply to the capsule is required. Using a robotic manipulator for locating the external magnet, the capsule motion control system can cover the whole human digestive organs. This study is particularly concentrated on dither motion effect to improve the mobility of capsule type endoscope. It was experimentally found out that the friction coefficient between the capsule and digestive organ can be remarkably reduced by superposing yawing or rolling dither motion on the translatory motion. In this paper, the experimental results obtained with the direction, amplitude and frequency of sinusoidal dither motion changed is reported.