• Title/Summary/Keyword: Capillary flow

Search Result 379, Processing Time 0.031 seconds

Capillary Breakup of Viscoelastic Fluid and its Extensional Rheology (점탄성유체의 Capillary Breakup 가시화 및 신장유변물성 측정)

  • Jeon, Hyun Woo;Choi, Chan Hyuck;Kim, Byung Hoon;Park, Jinsoo
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.1
    • /
    • pp.81-87
    • /
    • 2021
  • Extensional flow of viscoelastic fluids is widely utilized in various industrial processes such as electrospinning, 3D printing and plastic injection molding. Extensional rheological properties, such as apparent viscosity and relaxation time, play an important role in the design and evaluation of the viscoelastic fluid-involved processes. In this work, we propose a lab-built capillary breakup extensional rheometer (CaBER) based on flow image processing to investigate the capillary breakup of polyethylene oxide (PEO) solution and its extensional rheological properties. We found that the apparent extensional viscosity and extensional relaxation time of the PEO solution are independent of the strike time. The proposed CaBER is expected to be applied to characterization of the extensional rheological properties of viscoelastic fluids at low cost with high precision.

An Assessment of Friction Factor and Viscosity Models for Predicting the Refrigerant Characteristics in Adiabatic Capillary Tubes (마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가)

  • Son, Ki-Dong;Park, Sang-Goo;Jeong, Ji-Hwan;Lee, Sung-Hong;Kim, Lyun-Su
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.140-148
    • /
    • 2009
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses and flashing simultaneously. In this paper flow characteristics of adiabatic capillary tubes were simulated with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models. The predicted pressure distribution and mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing suitable correlations of friction factor, two-phase viscosity and two-phase frictional multiplier.

A NUMERICAL STUDY ON JET IMPINGEMENT OF PULSED PLASMA DISCHARGE ON A FLAT PLATE (벽면에 충돌하는 펄스 플라즈마 제트 유동특성에 대한 수치적 연구)

  • Kim, K.;Kwak, H.S.;Park, J.Y.
    • Journal of computational fluids engineering
    • /
    • v.14 no.1
    • /
    • pp.70-77
    • /
    • 2009
  • In this study, time-dependent numerical analysis was carried out to investigate the plasma jet impingement on a flat plate, and a compressible form of two-dimensional inviscid gas dynamics equations were solved using the flux corrected transport algorithm. The mathematical modeling of Joule heating in the polycarbonate capillary bore and the mass ablation from the bore wall was incorporated in the numerical analysis and the series of computation was performed for three cases depending on the distance of the opposing plate from the capillary exit. The computational results reveal that the presence of the opposing plate does not affect the flow conditions inside the capillary when compared to the case of open-air plasma discharge. In the exterior region, the flow structure shows the typical supersonic underexpanded jet which consists of the strong Mach disk in front of the opposing plate and the barrel shock at the side of the jet. It is found that the shock evolution becomes more quasi-steady when the plate distance decreases. Also, the effects of the distance between the capillary bore exit and the opposing plate on the flow conditions along the opposing plate are investigated and the pressure variation on the plate shows more complicated interaction between the plasma discharge and the opposing plate when the location of plate becomes closer to the capillary exit.

Investigation of the Performance of the Alternative Refrigerant HFC-134a through Capillary tube : Numerical Analysis (대체냉매 HFC-134a의 모세관 성능에 관한 수치해석적 연구)

  • Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.169-178
    • /
    • 1993
  • Performance charts of capillary tubes for R-134a are presented. The calculation is based on the one-dimensional, adiabatic flow through capillary tube. The length of capillary tube changes with inlet pressure, mass flux, inlet quality(or subcooling), and inside diameter. The length for R-134a is shorter by 12.5~23% than that for R-12 as mass flux varies, by 13~18.5% as inlet pressure changes, by 15~15.2% as inside diameter changes, and by 3.6~20% as subcooling(or quality) changes. In general, the length for R-134a is shorter than that for R-12 by 10~20%. Pressure drop per unit length for R-134a is greater than that for R-12 since specific volume of R-134a is larger that of R-12 and vapor pressure of R-134a is greater than that of R-12. Flash point of R-134a is ahead of that of R-12.

  • PDF

An assessment of friction factor and viscosity models for predicting the refrigerant characteristics in adiabatic capillary tubes (마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가)

  • Son, Ki-Dong;Park, Sang-Goo;Jeong, Ji-Hwan;Kim, Lyun-Su
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.47-54
    • /
    • 2008
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses, and flashing, simultaneously. In this paper flow characteristics of adiabatic capillary tubes with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models were simulated. The predicted pressure distribution, mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing the suitable correlations of friction factor and two-phase viscosity model, and two-phase frictional multiplier.

  • PDF

Continuous Viscosity Measurement of Non-Newtonian Fluids over a Range of Shear Rates Using a Mass-Detecting Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.255-261
    • /
    • 2002
  • A newly designed mass-detecting capillary viscometer uses a novel concept to continuously measure non-Newtonian fluids viscosity over a range of shear rates. A single measurement of liquid-mass variation with time replaces the now rate and pressure drop measurements that are usually required by capillary tube viscometers. Using a load cell and a capillary, we measured change in the mass flow rate through a capillary tube with respect to the time, m(t), from which viscosity and shear rate were mathematically calculated. For aqueous polymer solutions, excellent agreement was found between the results from the mass-detecting capillary viscometer and those from a commercially available rotating viscometer. This new method overcomes the drawbacks of conventional capillary viscometers meassuring non-Newtonian fluid viscosity. First, the mass-detecting capillary viscometer can accurately and consistently measure non -Newtonian viscosity over a wide range of shear rate extending as low as 1 s$\^$-1/. Second, this design provides simplicity (i. e., ease of operation, no moving parts), and low cost.

System Performance for Length and Diameter of Capillary Tube using R-1270 (모세관 길이와 관경 변화에 따른 R-1270의 성능특성)

  • Lee, Ho-Saeng;Kim, Hyun-Woo;Choi, Won-Jae;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.646-652
    • /
    • 2009
  • Experimental results for performance characteristics of HCs refrigerant R-1270 and HCFC refrigerant R-22 during refrigeration system using capillary tube are presented. The system consists of compressor, condenser, capillary tube, evaporator and peripheral devices. Length and diameter of capillary tube are varied for this investigation. The refrigerant mass flow increased as the diameter of capillary tube increased and the length of capillary tube decreased. A refrigeration capacity and compressor work of R-1270 in same length and diameter of capillary tube showed the higher values than those of R-22. A coefficient of performance showed the highest value when the length and diameter of capillary tube are 105 cm and 1.8 mm in this experimental conditions.

Bubble breakup dynamics and flow behaviors of a surface-functionalized nanocellulose based nanofluid stabilized foam in constricted microfluidic devices

  • Wei, Bing;Wang, Yuanyuan;Wen, Yangbing;Xu, Xingguang;Wood, Colin;Sun, Lin
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.24-32
    • /
    • 2018
  • Nanocellulose was surface-functionalized toward the applications in enhanced oil recovery (EOR) as a green alternative. The focus of this paper is on the effect of this material based nanofluid (NF) on foam lamella stabilization through studying its bubble breakup dynamics and flow behaviors in constricted mircofluidic devices. The NF stabilized foam produced an improved flow resistance across the capillary largely due to the capillary trapped bubbles at the contraction. The "snap-off" caused the NF stabilized foam to produce finer textured bubbles, which can migrate readily forward to the deep porous media, as revealed by the pressure profiles.

An Experimental Study on the Effect of Capillary Pressure on the Void Formation in Resin Transfer Molding Process (수지이동 성형공정에서 기공형성에 미치는 모세관압의 영향에 관한 실험적 연구)

  • 이종훈;김세훈;김성우;이기준
    • The Korean Journal of Rheology
    • /
    • v.10 no.4
    • /
    • pp.185-194
    • /
    • 1998
  • Flow-induced voids during resin impregnation and poor fiber wetting give serious effects on the mechanical properties of composites in resin transfer molding process. In order to better understand the characteristics of resin flow and to investigate the mechanism of void formation, flow visualization experiment for the resin impregnation was carried out on plain weaving glass fiber mats using silicon oils with various viscosity values. The permeability and the capillary pressure for the fiber mats of different porosities were obtained by measuring the penetration length of the resin with time and with various injection pressure. At low porosity and low operating pressure, the capillary pressure played a significant role in impregnation process. Video-assisted microscopy was used in taking the magnified photograph of the flow front of the resin to investigate the effect of the capillary pressure on the void formation. The results showed that the voids were formed easily when the capillary pressure was relatively high. No voids were detected above the critical capillary number of 2.75$\times$$10^{-3}, and below the critical number the void content increased exponentially with decrease of the capillary number. The content of void formed was independent of the viscosity of the resin. For a given capillary number, the void content reduced with the lower porosity of the fiber mat.

  • PDF

Simulation of the flow characteristics of R1234yf flowing through capillary tubes (냉매 R1234yf의 모세관내 유동 특성에 관한 해석적 연구)

  • Kim, Daeyeong;Park, Chasik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6452-6457
    • /
    • 2014
  • R1234yf has been developed as an alternative refrigerant to R134a, which has been associated with global warming. The capillary tubes as expansion valves control the mass flow rate and balance system pressure in the refrigeration cycle. The present numerical model used the governing equations including the law of conservation of mass, momentum, and energy in a capillary tube. The mass flow rate of R1234yf decreased by 47.0% as the capillary tube length was increased from 1 to 4 m. As the inner diameter of the capillary tubes was changed from 1.3 to 1.7 mm, the mass flow rate of R134a and R1234yf increased by 117.9% and 121.0%, respectively. The mass flow rate of the R134a and R1234yf increased by 28.3% and 29.1% with subcooling increasing from 0 to $7^{\circ}C$. In addition, when the inlet temperature of the capillary tubes was changed from 35 to $60^{\circ}C$, the mass flow rate of R134a and R1234yf increased by 31.0% and 45.4%, respectively.