• Title/Summary/Keyword: Capillary Pumped

Search Result 14, Processing Time 0.024 seconds

An Experimental Study on Small Capillary Pumped Cooling System (모세구동 소형 냉각시스템의 실험적 연구)

  • Yang, J.K.;Lee, K.J.;Lee, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.234-239
    • /
    • 2000
  • The capillary pumped cooling system (CPCS) is a cooling system which controls temperature of the small electronic devices, such as IC device systems, notebook computers, etc. An important feature of CPCS is that a working fluid circulates in a system by capillary force in tubes instead of mechanical input power. The cooling effect of CPCS is investigated with respect to heat flux, condensation temperature under different working fluids (water, ethanol, methanol). Capillary pumped flows are visualized under various conditions and mass flow rate and temperature are experimentally measured. It is shown that the increasing tendency of mass flux for each working fluid is observed as the temperature of evaporator increases, and that the cooling possibility of CPCS depends on the performance of evaparator and condenser which sustains the steady state temperature continuously.

  • PDF

Transient Heat Transfer for the Evaporators of Capillary Pumped Loop at Intial Startup (초기시동 시의 모세펌핑 루프 증발기에 대한 과도열전달 해석)

  • Park, Byung-Kyu;Kim, Geun-Oh;Kim, Moo-Geun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.252-259
    • /
    • 2001
  • It is derived for the temperature profile in a cylindrical and planar shape capillary pumped loop evaporators subject to a uniform heat flux prior to the initiation of boiling using the finite difference method. The results of the analysis allow for the determination of applied power levels for which nucleation is likely to occur only within the vapor grooves of the evaporator while maintaining subcooling in the liquid core, thereby increasing the likelihood of a successful startup. Also, limits are found for which additional increases in the applied heat flux do not increase the temperature difference between the vapor grooves and the wick-liquid core interface. Several advantages of larger diameter evaporators observed experimentally in startup are explained and quantified by the model. This analysis is appropriate for standard capillary pumped loop evaporators during a fully-flooded startup as well as starter pump designs and loop heat pipes.

  • PDF

The Effect of Energy Transport using Capillary Pumped Loop with PVA sponge Wick (PVA 스폰지 윅을 갖는 Capillary Pump Loop의 에너지 전달효과)

  • Jun, C.H.;Jang, Y.S.;Kim, O.G.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.21-28
    • /
    • 1999
  • This study was carried out to investigate the effect of energy transport using capillary pumped loop with PVA sponge wick. The results obtained from this study are as follows. The configuration of capillary pumped loop was adequate and PVA sponge was of great use for the manufacture of capillary pump. The energy transport reached maximum when the working fluid amount was 750cc the wall temperature distribution indicated high values through out the entire length of the pipe. As the opening of a nozzle was increased, energy transport was increased but the effect was decreased.

  • PDF

Effect of Groove and Channel Size on the Thermal Transport Capacity of Micro-Capillary Pumped Loop for Mobile Electronic Device Cooling System (모바일 전자장비 냉각용 Micro-CPL내 형상크기변화에 따른 열성능 해석)

  • Kim, Byeong-Gi;Seo, Jeong-Se;Hwang, Geon;Mun, Seok-Hwan;Bae, Chan-Hyo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.329-334
    • /
    • 2005
  • As more high power wide band gap devices are being utilized. the thermal management issues associated with these devices need to be resolved. High power small devices dissipate excessive heat that must be cooled, but traditional cooling methods are insufficient to provide such a cooling means. This paper will evaluate a micro-capillary pumped loop thermal management system that is incorporated into the shim of the device, taking advantage of phase-change to increase the thermal conductivity of the system. The results of the modeling of the thermal management system will be discussed.

  • PDF

Effects of Mesh Size in a Flat Evaporator and Condenser Cooling Capacity on the Thermal Performance of a Capillary Pumped Loop

  • Boo, Joon-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.121-129
    • /
    • 2000
  • The thermal performance of a flat evaporator for capillary pumped loop (CPL) applications was investigated. Two to four layers of coarse wire screen wicks were placed onto the heated surface to provide irregular passages for vapor flow. The evaporator and condenser were separated by a distance of 1.2 m and connected by individual liquid and vapor lines. The wall material was copper and the working fluid was ethanol. The experimental facility utilized a combination of capillary and gravitational forces for liquid return, and distribution over the evaporator surface. The tubing used for vapor and liquid lines was 9.35 mm or less in diameter and heat was removed from the condenser by convection of air. A heat flux of up to $4.9{\times}10^4$ $W/m^2$ was applied to a flat evaporator having dimensions of 100 mm by 200 mm, 20 mm thick. The thermal resistance of the system as well as the temperature characteristics of the system was investigated as the evaporator heat flux and the condenser cooling capacity varied. The performance of the evaporator and effect of condenser cooling capacity were analyzed and discussed.

  • PDF

manufacturing micro CPL (Capillary Pumped Loop)by using LIGA process (LIGA process를 이용한 micro CPL(Capillary Pumped Loop)제작)

  • Cho, Jin-Woo;Jung, Suk-Won;Park, Joon-Shik;Park, Sun-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1881-1883
    • /
    • 2001
  • We manufactured a micro CPL by LlGA process, a new conceptual ultra-fine and precise forming method, using X-ray lithography process. We fabricated a BN X-ray mask having properties of good X-ray transmittance and large mechanical strength. Micro CPL was manufactured by dividing into an upper plate and a low plate. Each of plates was bonded by Ag paste screen printing. The upper plate was fabricated on glass wafer to observe flow and phase transformation of cooling solution. The lower plate was manufactured by Cu electroplating for good heat transmission. Precision of inner Parts, micro pin and micro channel, of manufactured micro CPL is under ${\pm}2{\mu}m$.

  • PDF

Experimental Study of the Effect of the Reservoir on CPL Operation (CPL의 운전에 미치는 레저버의 영향에 대한 실험적 연구)

  • Hwang, Hyung-Jin;Joung, Wuk-Chul;Lee, Jin-Ho
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2033-2038
    • /
    • 2008
  • The CPLs(capillary pumped loops) are two phase heat transfer devices which enable active control of operating temperature of heat absorbing elements(or evaporators). Although the CPLs gain increasing interests as promising heat transfer devices for future missions such as spacecraft and commercial applications, their intrinsic complexity in operating principles makes the widespread use of these devices difficult. The key element and main cause of this complexity in operating principles is the two phase hydrodynamic accumulator or reservoir which controls the saturation state of the remaining loop and, particularly for the CPLs, it is separated from the evaporator. Thus, in this study, the operating characteristics of the CPL is investigated experimentally and theoretically. Mainly focusing on the role of reservoir the thermodynamic operating principle is examined first and the experimentally obtained steady state and transient state operating characteristics are discussed in detail.

  • PDF

A Study on the Operating Characteristics for a small scale CPL (소형 CPL의 작동 특성에 관한 연구)

  • 안영길;유성열;임광빈;김철주
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.97-105
    • /
    • 2002
  • 최근 5년 사이의 급속한 정보통신의 발전과 전자소자의 고집적화, 소형화는 전자장비 내부의 열부하 증가를 초래하고 있다. 이에 효과적으로 열을 제거하는 기술개발 요구로 다양한 이상 열전달 시스템(two-phase systems)이 연구되고 있다. CPL(Capillary Pumped Loop) 기술은 1960년대 미국, 구소련에서 우주항공분야의 전자장비 온도제어 시스템으로 주로 통신위성 또는 우주선의 전자장비 냉각기술의 한 방법으로 사용되어 왔으며 NASA Lewis Research Center의 Stenger에 의해 처음 제안되었다.(중략)

  • PDF