• 제목/요약/키워드: Capillary Flow

검색결과 383건 처리시간 0.023초

A Novel Technoque for Characterization of Membranes

  • Webber, Ronald;Jena, Akshaya;Gupta, Krishna
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2001년도 제14회 심포지엄 : 제2회 분리막 표준화(The 2nd Standardization of Membranes)
    • /
    • pp.39-50
    • /
    • 2001
  • The performance of membranes is governed their pore struture. Pore structures of porous materials can be determined by a number of techniques. However, The novel technique, capillary folw porometry has a number of advantages. In this technique, the sample is brought in contact with a liquid that fills the pores in the membrane spontaneously. Gas under pressure is used to force the liquid from the pores and increase gas flow. Gas flow rate measured as a function of gas pressure in wet and dry samples yield data on the largest pore size, the mean flow pore size, flow distribution and permeability. Pore characteristics of a number of membranes were measured using this technique. This technique did not require the use of any toxic material and the pressure employed was low. Capillary flow porometry is a suitable technique for measurement of the pore structure of many membranes.

  • PDF

마이크로 채널내 박막영역에서의 증발 모델링 (Evaporative Modeling in n Thin Film Region of Micro-Channel)

  • 박경우;노관중;이관수
    • 대한기계학회논문집B
    • /
    • 제27권1호
    • /
    • pp.17-24
    • /
    • 2003
  • A mathematical model of the hydrodynamic and heat transfer performances of two-phase flow (gas-liquid) in thin film region of micro channel is proposed. For the formulation of modeling, the flow of the vapor phase and the shear stress at the liquid-vapor interface are considered. In this work, disjoining pressure and capillary force which drive the liquid flow at the liquid-vapor interface in thin film region are adopted also. Using the model, the effects of the variations of channel height and heat flux on the flow and heat transfer characteristics are investigated. Results show that the influence of variation of vapor pressure on the liquid film flow is not negligible. The heat flux in thin-film region is the most important operation factor of micro cooler system.

소형 모세관식 알카리 금속 열전변환소자의 사이클해석 (Cycle Analysis of an Alkali Metal Thermo-Electric Converter for Small Capillary Type)

  • 윤석구;구재현;이재근;전중 경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.956-961
    • /
    • 2000
  • This paper describes the design of a small size Alkali Metal Thermal to Electric Converter (AMTEC) which employs a capillary structure for recirculating sodium working fluid. The cycle is based on the simple and small capillary type ${\beta}"$ -alumina and wick tube element. The proposed cell consists of the 37 conversion elements with capillary tube of $50{\mu}m$ in diameter and the sealed cylindrical vessel of 22mm in outer diameter. Results on the cycle analysis of sodium flow and heat transfer in the cell showed that the expected power output was 4.65W and the conversion efficiency was 19% for the source temperature of 900K.

  • PDF

Polyamide 역삼투막의 투과성능과 막 이동 모델의 해석 (Interpretation of Permeation Characteristics and Membrane Transport Models Through Polyamide Reverse Osmosis Membrane)

  • 김노원;김영길;이용택
    • 멤브레인
    • /
    • 제14권1호
    • /
    • pp.75-84
    • /
    • 2004
  • 폴리아미드계 역삼투 분리막의 투과성능을 비교하기 위하여 NaCl과 NaOCl을 함유하는 혼합용액을 공급수로 사용하여 연속운전과 단속운전 하에서 실험하여 보았다. 이 결과를 가지고 막 이동 모델의 선택적 적용이 가능함을 제시하고자 하였으며 투과 성능 분석 결과, 용액 확산 모델과 선흡착-모세관이동 모델이 운전 모드에 따라 상대적으로 유용함을 볼수 있었다. 연속 운전에서는 선흡착-모세관이동 모델을, 단속 운전에서는 용액 확산 모델을 따름을 알 수 있었다 NaOCl에 의한 표면 변화를 SEM 사진을 통하여 확인 할 수 있었다. 연속운전 후의 막은 염소 투과 결과 표면에서 부분적인 ridge and valley 구조가 나타났으며 단속 운전 후의 막은 표면 전반에서 변성이 일어난 것을 볼 수 있었다.

Capillary Rheometer를 이용한 숙성시간 및 함수율 변화 도자소지의 가소성평가 (Plasticity Evaluation of Porcelain Body Depend on Aging Period and Water Content Change Using Capillary Rheometer)

  • 김근희;피재환;김진호;김영환;조우석;김경자
    • 한국세라믹학회지
    • /
    • 제49권3호
    • /
    • pp.231-235
    • /
    • 2012
  • Plasticity is the ability of clay to respond to pressure with a continuous and permanent change of shape in any direction without breaking apart, and hold that shape when released. In this work, the effect of water content and aging period on the plasticity of porcelain clay was evaluated using the capillary rheometer to measure the flow rate and the shear stress. The shear stress of porcelain clay was slightly increased with increasing the aging period, indicating that the plasticity of porcelain clay was influenced by an organic content. It was also observed that the water content in the porcelain clay had a great influence on the plasticity of porcelain clay. The shear stress with water content of 21 wt% was sharply increased with increasing shear rate, but the shear stresses with water contents of 24 and 27 wt% is gently incremented.

모세관 인력으로 작동되는 열공압형 마이크로 펌프의 형상이 성능에 미치는 영향 (The Influence of the Geometry on the Performance of a Thermopneumatic Micropump Operated by Capillary Attraction)

  • 전도한;양상식
    • 대한기계학회논문집B
    • /
    • 제33권10호
    • /
    • pp.778-782
    • /
    • 2009
  • Recently, we developed a simple thermopneumatic micropump having neither a membrane nor a valve. This micropump discharges liquid by a thermopneumatic pressure and refill by a capillary attraction. In case of the micropump driven by the capillary attraction, the flow characteristic depends mainly on the geometry of the micropump. In this paper, we investigated the influence of the geometry of the micropump on the performance of the micropump to illustrate the properness of the micropump shape. We analyzed the micropump characteristics of six types having different geometries by FVM simulation with a commercial CFD tool. Also we fabricated the micropumps with PDMS and glass by micromachining, and tested the performances. The simulation and the test results illustrate that the discharge volume and the discharge time depend on the chamber volume. The expansion angle of the inlet channel location has influence on the refill time, while the front air channel direction has influence on the backward flow loss.

소수성 Needle을 이용한 미세 유기 박막 Stripe 제작 (Fabrication of Fine Organic Thin-Film Stripes Using a Hydrophobic Needle)

  • 김종명;이진영;신동균;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제19권1호
    • /
    • pp.73-78
    • /
    • 2020
  • There appears lateral capillary force in a hydrophilic flat needle employed for the fabrication of fine organic thin-film stripes, bringing in an increase of the stripe width. It also causes the stripe thickness to increase with increasing coating speed, which is hardly observed in a normal coating process. Through computational fluid dynamics (CFD) simulations, we demonstrate that the lateral capillary flow can be substantially suppressed by increasing the contact angle of the needle end. Based on the simulation results, we have coated the outer surface of the flat needle with a hydrophobic material (polytetrafluoroethylene (PTFE) with the water contact angle of 104°). Using such a hydrophobic needle, we can suppress the lateral capillary flow of an aqueous poly(3,4-ethylenedioxythiophene): poly(4-styrenesulfonate) (PEDOT:PSS) to a great extent, rendering the stripe narrow (63 ㎛ at 30 mm/s). Consequently, the stripe thickness is decreased as the coating speed increases. To demonstrate its applicability to solution-processable organic light-emitting diodes (OLEDs), we have also fabricated OLED with the fine PEDOT: PSS stripe and observed the strong light-emitting stripe with the width of about 68 ㎛.

Capacity Modulation of an Inverter Driven Heat Pump with Expansion Devices

  • Lee, Yong-Taek;Kim, Yong-Chan;Park, Youn-Cheol;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.60-68
    • /
    • 2000
  • An experimental study was peformed to investigate characteristics of an inverter driven heat pump system with a variation of compressor frequency and expansion device. The compressor frequency varied from 30Hz to 75Hz, and the performance of the system ap-plying three different expansion devices such as capillary tube, thermostatic expansion valve(TXV), and electronic expansion valve (EEV) was measured. The load conditions were altered by varying the temperatures of the secondary fluid entering condenser and evaporator with a constant flow rate. When the test condition was deviated from the standard value(rated value), TXV and EEV showed better performance than capillary tube due to optimal control of mass flow rate and superheat. In the present study, it was observed that the variable area expansion device had better performance than constant area expansion device in the inverter heat pump system due to active control of flow area with a change of com-pressor frequency and load conditions.

  • PDF

휴대용 POC 시스템을 위한 원터치형 면역 센싱 랩온어칩 (One-Touch Type Immunosenging Lab-on-a-chip for Portable Point-of-care System)

  • 박신욱;강태호;이준황;윤현철;양상식
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1424-1429
    • /
    • 2007
  • This paper presents a simple and reliable one-touch type multi-immunosensing lab-on-a-chip (LOC) detecting antibodies as multi-disease markers using electrochemical method suitable for a portable point-of-care system (POCS). The multi-stacked LOC consists of a PDMS space layer for liquids loading, a PDMS valve layer with 50 im in height for the membrane, a PDMS channel layer for the fluid paths, and a glass layer for multi electrodes. For the disposable immunoassay which needs sequential flow control of sample and buffer liquids according to the designed strategies, reliable and easy-controlled on-chip operation mechanisms without any electric power are necessary. The driving forces of sequential liquids transfer are the capillary attraction force and the pneumatic pressure generated by air bladder push. These passive fluid transport mechanisms are suitable for single-use LOC module. Prior to the application of detection of the antibody as a disease marker, the model experiments were performed with anti-DNP antibody and anti-biotin antibody as target analytes. The flow test results demonstrate that we can control the fluid flow easily by using the capillary stop valve and the PDMS check valves. By the model tests, we confirmed that the proposed LOC is easily applicable to the bioanalytic immunosensors using bioelectrocatalysis.

Analytical study on seepage behavior of a small-scale capillary barrier system under lateral no-flow condition

  • Byeong-Su Kim
    • Geomechanics and Engineering
    • /
    • 제35권1호
    • /
    • pp.13-27
    • /
    • 2023
  • The model production for large-scale (lateral length ≥ 2.0 m) capillary barrier (CB) model tests is time and cost-intensive. To address these limitations, the framework of a small-scale CB (SSCB) model test under the lateral no-flow condition has been established. In this study, to validate the experimental methodology of the SSCB model test, a series of seepage analyses on the SSCB model test and engineered slopes in the same and additional test conditions was performed. First, the seepage behavior and diversion length (LD) of the CB system were investigated under three rainfall conditions. In the seepage analysis for the engineered slopes with different slope angles and sand layer thicknesses, the LD increased with the increase in the slope angle and sand layer thickness, although the increase rate of the LD with the sand layer thickness exhibited an upper limit. The LD values from the seepage analysis agreed well with the results estimated from the laboratory SSCB mode test. Therefore, it can be concluded that the experimental methodology of the SSCB model test is one of the promising alternatives to efficiently evaluate the water-shielding performance of the CB system for an engineered slope.