• 제목/요약/키워드: Capillary

검색결과 1,987건 처리시간 0.026초

대체냉매 R-407C의 모세관 선정에 관한 연구 (Investigation on the selection of capillary tube for the alternative refrigerant R-407C)

  • 김용환;김창년;박영무
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.56-65
    • /
    • 1998
  • In this paper, experimental investigation of capillary tube performance for R-407C is performed. The experimental setup is made of real vapor-compression refrigerating system. In this study, mass flow rate is measured for capillary tubes of various diameter and length as inlet pressure and degree of subcooling are changed. These data are compared with the results of a numerical model. The mass flow rates of the numerical model are less than by 14% compared with the measured mass flow rates. It is found that mass flow rate and length for R-407c are less than those of R-22 under the same condition. Also based on this experimental study and the numerical model, a set of capillary tube selection charts for R-407C is constructed.

  • PDF

Characteristics of Refrigerant Flow through Capillary Tubes and Short Tube Orifices

  • Kim, Yong-Chan;Choi, Jong-Min
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.11-21
    • /
    • 1999
  • The capillary tube and short tube orifice have been widely used as an expansion device in the refrigeration and air-conditioning system. To improve the system performance, expansion devices need to be optimized with the components of a refrigeration system. In the present study, a numerical model for a capillary, which could predict the flow rate and properties along a tube, was developed by assuming homogeneous two-phase flow. A semi-empirical flow model for evaluation of the flow rate through a short tube orifice was also developed by using the experimental data. Finally, the results of the numerical model for a capillary was compared with those of the semi-empirical model for a short tube orifice to identify the dominant flow factors for the expansion devices.

  • PDF

PVA 스폰지 윅을 갖는 Capillary Pump Loop의 에너지 전달효과 (The Effect of Energy Transport using Capillary Pumped Loop with PVA sponge Wick)

  • 전철호;장영석;김오근
    • 태양에너지
    • /
    • 제19권2호
    • /
    • pp.21-28
    • /
    • 1999
  • This study was carried out to investigate the effect of energy transport using capillary pumped loop with PVA sponge wick. The results obtained from this study are as follows. The configuration of capillary pumped loop was adequate and PVA sponge was of great use for the manufacture of capillary pump. The energy transport reached maximum when the working fluid amount was 750cc the wall temperature distribution indicated high values through out the entire length of the pipe. As the opening of a nozzle was increased, energy transport was increased but the effect was decreased.

  • PDF

모세구동 소형 냉각시스템의 실험적 연구 (An Experimental Study on Small Capillary Pumped Cooling System)

  • 양재경;이규정;이정현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.234-239
    • /
    • 2000
  • The capillary pumped cooling system (CPCS) is a cooling system which controls temperature of the small electronic devices, such as IC device systems, notebook computers, etc. An important feature of CPCS is that a working fluid circulates in a system by capillary force in tubes instead of mechanical input power. The cooling effect of CPCS is investigated with respect to heat flux, condensation temperature under different working fluids (water, ethanol, methanol). Capillary pumped flows are visualized under various conditions and mass flow rate and temperature are experimentally measured. It is shown that the increasing tendency of mass flux for each working fluid is observed as the temperature of evaporator increases, and that the cooling possibility of CPCS depends on the performance of evaparator and condenser which sustains the steady state temperature continuously.

  • PDF

소형 모세관식 알카리 금속 열전변환소자의 사이클해석 (Cycle Analysis of an Alkali Metal Thermo-Electric Converter for Small Capillary Type)

  • 윤석구;구재현;이재근;전중 경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.956-961
    • /
    • 2000
  • This paper describes the design of a small size Alkali Metal Thermal to Electric Converter (AMTEC) which employs a capillary structure for recirculating sodium working fluid. The cycle is based on the simple and small capillary type ${\beta}"$ -alumina and wick tube element. The proposed cell consists of the 37 conversion elements with capillary tube of $50{\mu}m$ in diameter and the sealed cylindrical vessel of 22mm in outer diameter. Results on the cycle analysis of sodium flow and heat transfer in the cell showed that the expected power output was 4.65W and the conversion efficiency was 19% for the source temperature of 900K.

  • PDF

고무복합체의 모세관 압출에서 비선형 점탄성 모델의 적용 (An Application of Non-linear Viscoelastic Model to Capillary Extrusion of Rubber Compounds)

  • 최성현;류민영
    • 소성∙가공
    • /
    • 제16권4호
    • /
    • pp.260-265
    • /
    • 2007
  • Rubber compounds have high viscoelastic property. One of the viscoelastic behaviors during profile extrusion is the swelling of extrudate. In this study, die swells of rubber compounds at the capillary die have been investigated through experiment and computer simulation. Experiments and simulations have been performed using fluidity tester and commercial CFD code, Polyflow respectively. Die swells of rubber compounds in a capillary die were predicted using non-linear differential viscoelastic model, Phan-Thien-Tanner(PTT) model for various relaxation times and relaxation modes. The results of simulation were compared with the experiments. Pressure and velocity distribution, and circulation flows at the comer of capillary die have been investigated through computer simulation. It is concluded that the PTT model successfully represented the amount of the die swell of rubber compounds for various relaxation times at different modes.

Capillary Zone Electrophoresis를 이용한 양이온 동시분석에 관한 연구 (Simultaneous Analysis of Inorganic Cations by Capillary Zone Electrophoresis)

  • 박성우;유재훈;진광호;서배석;김영상
    • 분석과학
    • /
    • 제12권4호
    • /
    • pp.341-345
    • /
    • 1999
  • The separation and determination of inorganic cations by a capillary zone electrophoresis was studied. Cations were separated by the capillary column and detected by indirect UV method. The running buffer of 0.03 M creatinine and 0.02 M-hydroxy isobutylic acid solution (pH 4.8) was used to improve the mobility of ions in the column. A potential of 18 kV was applied at anode. A complete separation of cations ranged within 15 min and detection limits were between 0.1 and 1.0 ppm. The applicability of the method for real samples was demonstrated.

  • PDF

모세관 전기영동 분석법의 복합약물제제의 품질관리 분석에 응용을 위한 연구 (Application of Capillary Electrophoresis for Quality Control Analysis of Complex Medicine)

  • 허유정;이공주
    • 약학회지
    • /
    • 제41권5호
    • /
    • pp.539-546
    • /
    • 1997
  • Capillary electrophoresis (CE) is perceived as an attractive tool for the analysis of pharmaceuticals and biological materials because of their high separation efficiency, easy separation and low running cost. New concept of micellar electrokinetic capillary chromatography (MECC) expanded the application of CE to the separation of neutral molecules. Validation of CE as an analytical technique for quality control of pharmaceuticals should be confirmed by quantitative analysis and the peak confirmation. In this study, the quantitative analyses of various types of neutral, acidic and basic components (acetaminophen, caffeine, ascorbic acid, riboflavin, thiamine, chlorpheniramine, phenylpropanolamine, dl-methylephedrine and dextromethorphan) in complex cold medicines have been accomplished using CE. Combined methods of MECC using SDS and capillary zone electrophoresis lowering the pH of running buffer were adopted to determine the ingredients in capsule type or liquid formula complex medicines without particular sample pretreatment. The results indicate that CE is a promising technique for quality control analysis of pharmaceuticals as a validation method.

  • PDF

그루브형 태양열 집열용 히트파이프의 열성능 해석 (Analysis for Thermal Performance of Axially Grooved Heat Pipe for Solar Collector)

  • 홍정규;서정세;변길성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2123-2128
    • /
    • 2004
  • In this study, analysis is made for the effects of groove shape on the thermal performance of a axial groove heat pipe. The mathematical models of two-phase flow in grooved heat pipe are presented for the capillary limitation in steady state. Generally, the heat pipe performance depends on the capillary pressure and liquid flow. The friction force of liquid flow through the groove increases with the groove width decreased, and then the capillary pressure is improved in the gas-liquid interface of groove. Therefore, the optimal groove width shaper exists for the maximum thermal performance of heat pipe. In this paper, the optimal groove shape and scale are presented by considering both capillary pressure and liquid flow.

  • PDF

Capillary electrophoresis를 이용한 한국산 및 중국산 고사리의 원산지 판별방법 개발 (Development of the Discrimination Methods for Geographical Origin of Bracken(Pteridium aquilinum) by Capillary Electrophoresis)

  • 김은영;김정현;정경숙;류미라
    • 분석과학
    • /
    • 제17권2호
    • /
    • pp.192-197
    • /
    • 2004
  • The discrimination of bracken (Korean vs. Chinese) has been attempted using capillary electrophoresis (CE). Bracken (Pteridium aquilinum) was extracted with 30% methanol and separated on a uncoated fused-silica ($50{\mu}m{\times}27cm$) capillary. Conditions for optimal analysis include: temperature, $40^{\circ}C$; voltage, 8 kV; and pressure injection time, 5 sec. The optimal separation buffer was 0.3 M borate buffer (pH 8.5) containing 40 mM CHAPS with 30% ethylene glycol. Under the optimal conditions established for CE, the ratio of specific peak area (peak PA-1) to other peak area (peak PA-2) was effective in discrimination of Korean and Chinese bracken. The mean accuracy for discrimination of Korean and Chinese brackens were 80% and 86%, respectively.