• 제목/요약/키워드: Capillary

Search Result 1,978, Processing Time 0.032 seconds

Analysis of Health-related Microbes by Capillary Electrophoresis

  • Moon, Byoung-Geoun;Kim, Yong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.8
    • /
    • pp.1203-1206
    • /
    • 2003
  • Analysis of health-related microbes called probiotics was performed by capillary electrophoresis. A rapid and easy characterization for two important probiotics, Saccharomyces cerevisiae and Enterococcus feacalis, was obtained in the running buffer containing poly(ethylene oxide). Quantitation of probiotic (Saccharomyces cerevisiae) shows a good linearity between the peak area versus the concentration of microbe. From the comparison of electropherograms of antidiarrhea, it was found that capillary electrophoresis could be employed for the quality control and quality assurance for the production of a medicine containing the probiotics.

A Screening Method on Resistance of Tobacco Plants to Bacterial Wilt (세균성마름병에 대한 담배의 저항성검정 방법)

  • 이영근
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.24 no.1
    • /
    • pp.27-31
    • /
    • 2002
  • Three kinds of inoculation methods, capillary, root cutting and dipping were compared for an efficient way to screening the resistant tobacco variety against bacterial wilt, Ralstonia solanacearum. The pricking a capillary tube contained the pathogenic bacterial suspension(10$^{7}$ cfu/$m\ell$) to an axillary bud of each tobacco plant showed different resistance well between varieties. The less period was required in inoculating work and in disease development for the inoculation method used with capillary tube than for two other inoculation methods tested also.

Measurement of the Viscosity of Semi-Soild Foods by Extrusion Capillary Viscometer (Extrusion Capillary Viscometer를 이용한 반고체 식품의 점도 측정 방법)

  • 김길환;이부용;김동만
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.20 no.5
    • /
    • pp.509-512
    • /
    • 1991
  • Rheological property and apparent viscosity(η)of several semi-solid foods were measured with extrusion capillary viscometer. Apparent viscosities of several semi-solid foods ranged from 0.2714 Pa.s to 2.6453 Pa.s Rheological property of spread type semi-solid foods was pseudoplastic (with yield value). Especially, as the moisture content and temperature of Chungkook-jang spread increased, apparent viscosity decreased. On the contrary, as the added soybean oil content of Chungkook-jang spread increased, apparent viscosity also increased.

  • PDF

Availability of Capillary Blood Gas Analysis in Neonate (신생아에서 모세혈 가스분석 검사의 유용성)

  • Jeong, Jong Tae;Yun, Su Young;Lee, Ran;Hyun, Jae Ho;Jung, Gyu Young
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.449-453
    • /
    • 2002
  • Purpose : Arterial blood gas analysis is frequently performed in neonatal intensive care unit (NICU) to evaluate ventilation and the metabolic state of critically ill infants. In occasions when umbilical arterial catheterization is not available, frequent arterial puncture is mandatory. This requires some technical skill and may occasionally have side effects. So we studied the validity of capillary blood gas analysis which can be performed conveniently compared with arterial blood. Methods : Twenty-four neonates admitted to NICU during April to Aug. 2001 were studied. They were more than two weeks old without indwelling arterial catheters. Thirty-six times, simultaneous arterial, and capillary blood gases were drawn by puncture and the pH, $pCO_2$ and $pO_2$ of each sample was measured. Blood pressure and body temperature was checked before sampling to rule out impaired peripheral circulation. Capillary blood was collected from warmed heels. Results : There was a strong correlation between capillary and arterial pH(r=0.91, P<0.05). The absolute value of the difference between arterial and capillary pH was less than 0.05. Also capillary $pCO_2$ showed correlation with arterial $pCO_2$(r=0.77, P<0.05). Despite a statistically significant correlation between capillary and arterial $pO_2$(r=0.68, P<0.05), the absolute value of the difference was more than 10 mmHg in 92% of cases. Conclusion : Capillary blood gases accurately reflected arterial pH and $pCO_2$ and showed a relative correlation with $pO_2$. Capillary blood gas analysis can be a useful alternative to arterial blood when continuation of the umbilical arterial catheter is no longer available.

Prediction of Adiabatic Capillary Tube Length of Heat Pump Using Carbon Dioxide (CO2 히트펌프용 단열 모세관 길이 예측에 관한 연구)

  • Oh, Hoo-Kyu;Choi, Kwang-Hwan;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.576-581
    • /
    • 2011
  • In this paper, the prediction of adiabatic capillary tube of heat pump using carbon dioxide is investigated theoretically and experimentally to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include evaporation temperature, cooling pressure of gas cooler, mass flowrate, and the length and diameter of capillary tube. Based on study results of several researchers, the correlation predicting the length of capillary tube of $CO_2$ heat pump was proposed. And the experimental results of evaporation temperature, mass flowrate and cooling pressure in adiabatic capillary tube have an good agreement to those calculated from Eq. (3) within 0.63~10.9%. Therefore, the prediction calculating the length of adiabatic capillary tube of $CO_2$ heat pump was proposed at the given conditions such as cooling pressure, evaporation temperature and capillary tube diameter.

Flow Characteristics of R600a in an Adiabatic Capillary Tube (단열 모세관내 R600a의 유동 특성)

  • Ku, Hak-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.449-454
    • /
    • 2010
  • In this paper, flow characteristics of R600a in an adiabatic capillary tube were investigated employing the homogeneous flow model. The model is based on fundamental equations of mass, energy and momentum which are solved simultaneously. Two friction factors(Churchill) and viscosity(McAdams) are comparatively used to investigate the flow characteristics. Thermodynamic and transport properties of R600a are calculated employing EES property code. Flow characteristics analysis of R600a in an adiabatic capillary tube is presented to offer the basic design data for the operating parameters. The operating parameters considered in this study include condensation temperature, evaporation temperature, subcooling degree and inner diameter tube of the adiabatic capillary tube. The main results were summarized as follows: condensation and evaporation temperature, inlet subcooling degree and inner diameter tube of an adiabatic capillary tube using R600a have an effect on length of an adiabatic capillary tube. The length of an adiabatic capillary tube using R600a is expressed to the correlation shown in Eq. (15).

Open Tubular Molecular Imprinted Polymer Fabricated in Silica Capillary for the Chiral Recognition of Neutral Enantiomers in Capillary Electrochromatography

  • Yang, Song-Hee;Zaidi, Shabi Abbas;Cheong, Won-Jo;ALOthman, Zeid A.;ALMajid, Abdullah M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1664-1668
    • /
    • 2012
  • In this study, we have expanded the applicability of the pre-established generalized preparation protocol to MIPs with a neutral template. The ($4S,5R$hyl-5-phenyl-2-oxazolidinone MIP layer was formed inside a pretreated and silanized fused silica capillary, and its chiral separation performance was examined. Optimization of chiral separation was also carried out. This is the very first report of somewhat successful application of the generalized preparation protocol to a MIP with a genuine neutral template.

Capillary Hemangioma of the Thoracic Spinal Cord

  • Chung, Sung-Kyun;Nam, Taek-Kyun;Park, Seung-Won;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.3
    • /
    • pp.272-275
    • /
    • 2010
  • Capillary hemangiomas are common soft tissue tumors on the skin or mucosa of the head and neck in the early childhood, but very rare in the neuraxis. A 47-year-old man presented with one month history of back pain on the lower thoracic area, radiating pain to both legs, and hypesthesia below 17 dermatome. Thoracic spine MRI showed $1{\times}1.3{\times}1.5\;cm$, well-defined intradural mass at T6-7 disc space level, which showed isointensity to spinal cord on T1, heterogeneous isointensity on T2-weighted images, and homogeneous strong enhancement. The patient underwent T6-7 total laminotomy, complete tumor removal and laminoplasty. Histologically, the mass showed a capsulated nodular lesion composed of capillary-sized vascular channels, which were tightly packed into nodules separated by fibrous septa. These features were consistent with capillary hemangioma.

A Generalized Correlation and Rating Charts for Mass Flow Rate through Capillary Tubes with Several Alternative Refrigerants

  • Choi Jong Min;Jang Yong Hee;Kim Yongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.192-197
    • /
    • 2004
  • A capillary tube, which is a common expansion device in small sized refrig-eration and air-conditioning systems, should be redesigned properly to establish an optimum operation cycle of a refrigerating system with alternative refrigerants. Based on experimental data for R-22, R-290, and R-407C, an empirical correlation is developed to predict mass flow rate through capillary tubes. Dimensionless parameters are derived from the Buckingham Pi theorem, considering the effects of operating conditions and capillary tube geometry on mass flow rate. Approximately $97\%$ of the present data are correlated within a relative deviation of $\pm\;10\%.$ The present correlation also predicts the data obtained from open literature within $\pm\;15\%.$ In addition, rating charts of refrigerant flow rate for R-12, R-22, R-134a, R-152a, R-407C, R-410A, R-290, and R-600a are developed.