• Title/Summary/Keyword: Capacity of use

Search Result 3,309, Processing Time 0.028 seconds

Biodegradation of Hydrocarbon Contamination by Immobilized Bacterial Cells

  • Rahman Raja Noor Zaliha Abd.;Ghazali Farinazleen Mohamad;Salleh Abu Bakar;Basri Mahiran
    • Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.354-359
    • /
    • 2006
  • This study examined the capacity of immobilized bacteria to degrade petroleum hydrocarbons. A mixture of hydrocarbon-degrading bacterial strains was immobilized in alginate and incubated in crude oil-contaminated artificial seawater (ASW). Analysis of hydrocarbon residues following a 30-day incubation period demonstrated that the biodegradation capacity of the microorganisms was not compromised by the immobilization. Removal of n-alkanes was similar in immobilized cells and control cells. To test reusability, the immobilized bacteria were incubated for sequential increments of 30 days. No decline in biodegradation capacity of the immobilized consortium of bacterial cells was noted over its repeated use. We conclude that immobilized hydrocarbon-degrading bacteria represent a promising application in the bioremediation of hydrocarbon-contaminated areas.

The effect of the number of nozzle holes on the energy separation (보텍스튜브의 노즐홀수가 에너지분리에 미치는 영향)

  • 유갑종;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.692-699
    • /
    • 1999
  • The vortex tube is a sample device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. The phenomena of energy separation through the vortex tube were investigated experimentally, to see the effects of the number of nozzle holes on the energy separation. The experiment was carried out with the number of nozzle holes from 1 to 10 by varying inlet pressure and cold mass fraction. The experimental results were indicated that the effective number of nozzle holes for the best cooling performance was found as 4. Also, to find effective use in a given operation conditions, the temperature difference of cold air and the cooling capacity of vortex tube was compared. The result is that cooling capacity was more important than temperature difference of cold air.

  • PDF

교차로 방향별 차선공동이용 연구

  • 김동녕
    • Journal of Korean Society of Transportation
    • /
    • v.6 no.2
    • /
    • pp.49-56
    • /
    • 1988
  • Alternate use of lane at a signalized intersection is a quite different control of the operation of an intersection. This control introduces a new stop line and signal before the original stop line. All of the lanes between the two stop lines are used for left turn traffic or through traffic at a time. The purpose of the control is increasing the capacity of a n intersection without widening the approach width. this paper contains a study on the condition of a application, the proper distances between the two stop lines, the reasonable offsets(rear) to guarantee clearing the vehicles of previous phase, the comparison of approach capacity between the existing control and this control. The study results reveals that the offsets(rear) are rather stable showing the range(maximum value minus minimum value) of it's value does not exceed 3.6 seconds according to the field data. The approach capacity will be increased by 27%, 43%, 59%, 84% when the distances between the stop lines are 30.0m respectively. The control might have theoretical limitation to operate in practice. So an experimental application of the control at some suitable intersections prior to expanding it.

  • PDF

Biotechnological Characteristics of Some Saccharomyces species Isolated from Wine Yeast Culture

  • Letitia, Oprean
    • Food Science and Biotechnology
    • /
    • v.14 no.6
    • /
    • pp.722-726
    • /
    • 2005
  • The use of isolated wine yeasts in winemaking processes is preferable to spontaneous fermentation. Selection criteria of wine yeast strains depend also on capacity and rate of fermentation and on alcohologenic capabilities. Our studies have described the dynamics of fermentation of wine musts by some isolated wine yeast strains of Saccharomyces genus: strains 6 and 8 of S. cerevisiae var. ellipsoideus (S. ellipsoideus) and strains 5 and 7 of S. bayanus var. oviformis (S. oviformis). All have high technological properties and all are adapted for the specific pedoclimatic conditions of some areas of Sibiu viticultural region. The selected strains were used as inocula to ferment Sauvignon, Muscat Ottonel, Rose Traminer, and Pino Gris musts in controlled laboratory conditions. It was found that higher initial oxygen concentration in must is necessary to accelerate the fermentation of all the wine yeast strains studied. In order to obtain quality wines, strains with considerable fermentative capacity, high alcohologenic capabilities, and a good conversion efficiency are recommended.

Adsorption of Specific Organics in Water on GAC and Regeneration of GAC by Countercurrent Oxidative Reaction

  • Ryoo, Keon-Sang;Kim, Tae-Dong;Kim, Yoo-Hang
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.6
    • /
    • pp.817-824
    • /
    • 2002
  • Granular activated carbon(GAC) is highly effective in removing organic compounds which are resistant to biological disintegration in wastewater treatment. However, GAC has reached its full adsorptive capacity, GAC needs to be regenerated before it can be used for a further adsorption cycle. Countercurrent oxidative reaction (COR) technique has been developed and evaluated for the regeneration of spent GAC. Various parameters such as flame temperature, the loss of carbon, destruction and removal efficiency (DRE) of organic compounds, surface area, surface structure, adsorptive capacity, etc. were examined to determine the performance of COR. The results of these tests showed that adosorptive capacity of regenerated GAC was completely recovered, the loss of carbon was controllable, flame temperature was high enough to insure complete destruction and removal $(\geq99.9999%)$ of specific organics of interest, polychlorinated biphenyls (PCBs), that are thermally stable, and on formation of toxic byproducts such as polychlorinated dibenzo-p-dioxins (PCDDs) or polychlorinated dibenzofurans (PCDFs) were detected during the regeneration process. The COR technique is environmentally benign, easy to use and less copital intensive than other available regeneration technologies.

Simplified Method for Estimating Energy-Dissipation Capacity of Flexure-Dominant RC Members (휨지배 철근콘크리트 부재의 에너지 소산능력 평가방법)

  • 엄태성;박홍근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.297-305
    • /
    • 2002
  • As advanced earthquake analysis/design methods such as the nonlinear static analysis are developed, it is required to estimate precisely the cyclic behavior of reinforced concrete members that is characterized by strength, deformability, and capacity of energy dissipation. However, currently, estimation of energy dissipation depends on empirical equations that are not sufficiently accurate, or experiment and sophisticated numerical analysis which are difficult to use in practice. In the present study, nonlinear finite element analysis was performed to investigate the behavioral characteristics of flexure-dominant RC members under cyclic load. The effects of axial force, arrangement of reinforcing bars, and reinforcement ratio on the cyclic behavior were studied. Based on the investigation, a simplified method to estimate the capacity of energy dissipation was proposed, and it was verified by the comparison with the finite element analyses and experiments. The proposed method can estimate the energy dissipation of RC members more precisely than currently used empirical equations, and it is easily applicable in practice.

  • PDF

An Experimental study to Improving the Sound Transmission Loss of Honeycomb sandwich Plates (허니컴 샌드위치판의 투과손실 개선에 관한 실험적 연구)

  • 유영훈;양보석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.92-99
    • /
    • 1998
  • The sound insulation capacity of honeycomb sandwich plates which have relatively higher strength ratios to weight is poorer than those of uniform and another sandwich plates. Therefore, improvement of the sound insulation capacity of the honeycomb sandwich plate which has a meritof lightness is required to use it in automobile and rapid rail road industries. In this study, to improving the sound insulation capacity of the honeycomb sandwich plate, the sound transmission loss of the structure is experimentally investigated by adding a viscoelastic damping layer, The effective add position and thickness of the layer were investigated from the viewpoints of both sound transmission loss and improved sound transmission loss over the frequency range from 800Hz to 10kHz.

  • PDF

A Paired Barrel Capable of Automatic Storage and Emptying of Water for a Weighing Raingauge (자동 저수와 배수가 가능한 중량 우량계 용 쌍수조)

  • Lim, Gyu-Ho;Lim, Eun Ok
    • Atmosphere
    • /
    • v.27 no.2
    • /
    • pp.251-258
    • /
    • 2017
  • The standard weighing raingauges have a capacity limit in measuring the amounts of precipitation. Exceptions are those using a siphon to drain the collected water during observations. To reduce the drain time of the siphon type or to overcome the hassles associated with the manual emptying of the bucket for measuring, the most of weighing gauges use a large bucket for storing of rainwater to be measured. To avoid the above-mentioned adverse requirements, we propose a paired barrel for a weighing raingauge. The paired barrel may improve the accuracy of the weighing raingauges by getting rid of their capacity limit and make the gauges smaller in size and lighter in weight than the conventional ones. We showed its proper function and the feasibility of realization by testing a prototype paired barrel.

Stability Analysis of Compressed Air Storage Caverns in Rockmass (전력생산을 위한 암반내 압축공기저장공동의 안정성분석)

  • 신희순;신중호;최성웅;한일영;김정엽
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.287-294
    • /
    • 2002
  • CAES which is called as a compressed air energy storage was firstly developed at Huntorf, German in 1978. The capacity of that system was 290MW, and it can be treated as a first commercial power plant. CAES has a lot of merits, such as saving the unit price of power generation, averaging the peak demand, improvement of maintenance, enlarging the benefit of dynamic use. According to the literature survey, the unlined rock cavern should be proposed to be a reasonable storing style as a method of compressed air storage in Korea. We decided the hill of the Korea Institute of Geoscience and Mineral Resources as CAES site. If we construct the underground spaces in this site, the demand for electricity nearby Taejon should be considered. So we could determine the capacity of the power plant as a 350MW, This capacity needs a underground space of 200,000㎥, and we can conclude 4 parallel tunnels 550m deep from the surface through the numerical studies, Design parameters were achieved from 300m depth boring job and image processing job.

  • PDF

Study on Utilizing Resources in Ecopolis -Evaluation of the Potential Heat Capacity of Sewage For Utilizing as Sewage Energy- (생태도시에서의 자원활용에 관한 연구 -하수 에너지 활용을 위한 보유열량 평가-)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.6
    • /
    • pp.583-591
    • /
    • 2003
  • The research on potential energy was conducted to conserve the high-exergy energy like primary energy and utilize waste heat from sewage. From the Point of view in using the waste heat, the energy Potential of waste water from the model house was simulated. From the results, when the heated water was supplied to the model house side in order to put unused energy to Practice use, heated water had higher energy Potential than unheated water, which was due to the discharge of most of unused energy. The possessing heat capacity of sewage from heated water was increased to 40-70 percents in comparison with that from the unheated water. Therefore, it can be used as energy source for improving coefficient of performance of heat pumps. By adopting the multiple heat pump into a model house, It showed that the possessing heat capacity of sewage was reduced. It was also found that the heat was recovered as energy source fur multiple heat pump in a model house.