• Title/Summary/Keyword: Capacity increase method

Search Result 1,109, Processing Time 0.03 seconds

Improvement of Flexural Capacity of Reinforced Concrete Beams Retrofitted by CFS (CFS로 보강된 철근콘크리트 보의 휨내력향상효과에 관한 연구)

  • Lee, Yong Taeg;Lee, Li Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.3
    • /
    • pp.203-211
    • /
    • 1999
  • This study is to examine the feasibility of carbon fiber sheet(CFS), a kind of fiber reinforced plastic(FRP), for a repair and reinforcement of R/C beams. The flexural strength of R/C beams, that were preloaded and then the cracks were repaired, maintains that of the uncracked R/C beams. The flexural strength of R/C beams increases with the reinforcement of CFS. In order to practically apply the repair and reinforcement method, further research is needed for the distribution, amount, and bond of CFS. In this study, an experiment was conducted for R/C beams reinforced with CFS, for various wrapping method and amounts of CFS. Experimental results showed the wrapping method increasing the bond area and amount of CFS layer caused the increase in the strength of the beams. It is found that the strength of CFS should be used as 70% of the maximum strength in retrofitting reinforced concrete beams in evaluating flexural capacity on the basis of ultimate strength design method.

  • PDF

An Analysis of the Composite Discharge Capacity Effect with GCP Method (GCP공법의 복합통수능 효과 분석)

  • Park, Minchul;Kwon, Hyukchan;Shin, Hyohee;Jang, Gisoo;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.37-46
    • /
    • 2011
  • An application frequency of vertical drainage method is increasing as an effective consolidation acceleration method. PBD method is most frequently used as a consolidation acceleration method in vertical drainage methods. PBD is economical and easy to operate but has some problems those are an environmental pollution and a decrease of a discharge capacity caused by bending of drainage materials when it is used in great depth. SCP method was frequently used because it's discharge capacity was good but now it is rarely used because of an increase of the material price because of an order imbalance. As the way to solve these problems, GCP method has been to the fore. For analyzing the effect of GCP method on the discharge capacity, three types of composite discharge capacity tests are done by using GCP, SCP and PBD respectively with the circle case, ${\phi}38{\times}h70cm$. On the contrary to this, GCP shows the worst discharge capacity for a decrease of the void ratio and the clogging phenomenon caused by increasing load. Also to figure out the clogging range of GCP, the clogging of GCP is checked in each load stage with a large case($1.0m{\times}0.5m{\times}1.1m$) which has clear acrylic front face. The diameter of GCP was 35cm and a clogging phenomenon occurred in 10% approximately. The result shows that the discharge capacity of GCP was given the lowest value for a decrease of the void ratio and the clogging phenomenon causing by increasing load. And the clogging phenomenon mostly occurred within 10% of GCP's diameter range.

Seismic Performance Evaluation of Multi-Span Bridges considering Effect of Lateral Load Distributions and Equivalent SDOF methods (횡하중 분포와 등가단자유도 방법의 영향을 고려한 다경간 교량의 내진성능 평가)

  • Song, Jong-Keol;Nam, Wang-Hyun;Chung, Yeong-Hwa
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.163-171
    • /
    • 2006
  • To evaluate inelastic seismic responses of multi-span-bridge, the equivalent single-degree-of-freedom (ESDOF) methods and the lateral load distributions are applied to the capacity spectrum method(CSM). From the pushover analysis results using the four ESDOF methods and the six types lateral load distributions, the ESDOF method more than lateral load distribution is found to have an important influence upon the pushover analysis. The effects of the higher mode on the bridge seismic behaviors are also increased as the number of pier increase. Therefore, it can be concluded that lateral load distributions and ESDOF methods for reflection of higher mode effects should be considered in the seismic analysis of the bridge structural.

  • PDF

Evaluation of long term shaft resistance of the reused driven pile in clay

  • Cui, Jifei;Rao, Pingping;Wu, Jian;Yang, Zhenkun
    • Geomechanics and Engineering
    • /
    • v.29 no.2
    • /
    • pp.171-182
    • /
    • 2022
  • Reusing the used pile has not yet been implemented due to the unpredictability of the bearing capacity evolution. This paper presents an analytic approach to estimate the sides shear setup after the dissipation of pore pressure. Long-term evolution of adjacent soil is simulated by viscoelastic-plastic constitutive model. Then, an innovative concept of quasi-overconsolidation is proposed to estimate the strength changes of surrounding soil. Total stress method (α method) is employed to evaluate the long term bearing capacity. Measured data of test piles in Louisiana and semi-logarithmic time function are cited to validate the effectiveness of the presented method. Comparisons illustrate that the presented approach gives a reasonably prediction of the side shear setup. Both the presented method and experiment show the shaft resistance increase by 30%-50%, and this highlight the potential benefit of piles reutilization.

An Experimental Study on Pullout Characteristics of Post-installed Set Anchor for Concrete under Edge Distance, Anchor Interval and Concrete Strength (연단거리, 앵커간격 및 콘크리트 강도에 따른 콘크리트용 후설치 세트앵커의 인발특성에 관한 실험적 연구)

  • Suth, Ratha;Yoo, Seung-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2469-2475
    • /
    • 2014
  • In 1990s, with the increase of domestic building renovation but also increase the amount of anchor. The 45-degree cone failure theory has been used in concrete anchor bolts design, but the CCD (concrete capacity design) method was adopted as a new design method since 2000. However, the method has some problems because it is based on the experimental results of pre-installed concrete anchor bolts. In this study, the objective is to investigate the effects of anchor edge distance, anchor interval and concrete strength on pullout characteristics of post-installed concrete set anchor embedded in plain concrete.

Proposing new models to predict pile set-up in cohesive soils

  • Sara Banaei Moghadam;Mohammadreza Khanmohammadi
    • Geomechanics and Engineering
    • /
    • v.33 no.3
    • /
    • pp.231-242
    • /
    • 2023
  • This paper represents a comparative study in which Gene Expression Programming (GEP), Group Method of Data Handling (GMDH), and multiple linear regressions (MLR) were utilized to derive new equations for the prediction of time-dependent bearing capacity of pile foundations driven in cohesive soil, technically called pile set-up. This term means that many piles which are installed in cohesive soil experience a noticeable increase in bearing capacity after a specific time. Results of researches indicate that side resistance encounters more increase than toe resistance. The main reason leading to pile setup in saturated soil has been found to be the dissipation of excess pore water pressure generated in the process of pile installation, while in unsaturated conditions aging is the major justification. In this study, a comprehensive dataset containing information about 169 test piles was obtained from literature reviews used to develop the models. to prepare the data for further developments using intelligent algorithms, Data mining techniques were performed as a fundamental stage of the study. To verify the models, the data were randomly divided into training and testing datasets. The most striking difference between this study and the previous researches is that the dataset used in this study includes different piles driven in soil with varied geotechnical characterization; therefore, the proposed equations are more generalizable. According to the evaluation criteria, GEP was found to be the most effective method to predict set-up among the other approaches developed earlier for the pertinent research.

Reverse link analysis of CDMA cellular systems with mixed cell sizes (혼합된 셀 크기를 갖는 CDMA 셀룰라 시스템에서 역방향 링크 용량 분석)

  • 전형구;신성문;권수근;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4A
    • /
    • pp.481-488
    • /
    • 2000
  • The demands for mobile communication service are growing rapidly. In heavily populated areas, cell split is unavoidable to increase the capacity of the cellular system. Cell splitting makes a cellular system to have mixed cell sizes. For cell planning, it is necessary to analyze the reverse link capacity of a CDMA cellular system with mixed cell sizes. In this paper, we propose a method to calculate the reverse link capacity of a CDMA cellular system with mixed cell sizes. When a macro cell is split into three micro cells, as an example, we calculate the reverse link capacities for the three micro cells and the neighboring macro cells. The results show that as the radius of a micro cell decreases, the reverse link capacity of the micro cell increases, while those of the neighboring macro cells decrease.

  • PDF

An Experimental Study on Improved Bearing-Capacity of Reinforced Concrete Beam Using Reinforcement Materials (보강재를 사용한 철근 콘크리트 보의 내력보강에 관한 실험적 연구)

  • 홍상균;박기철;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.495-500
    • /
    • 1996
  • In this paper, it is the effect of using fiber sheet (Carbon Fiber Sheet & Aramid Fiber Sheet) and Steel Plate for reinforced concrete beam, 25 specimens are tested, 16 specimens for bending capacity and the other are for shear capacity. In the case of bending testing, the kind and quantity of the reinforcement materials, the bondage and the existence of crack were selected as experimental variables. And in the case of shear testing, it is testified the effect of reinforcement with the variables of the method of reinforcement (side type and U type). As a result, using the reinforcement meterials can increase the capacity of bending stress.

  • PDF

An Improvement in the Properties of MH Electrode of Ni/MH Battery by the Copper Coating (Ni/MH 전지에서 Cu 도금에 의한 음극활물질의 전극 특성 향상)

  • Cho, Jin Hun;Kim, In Jung;Lee, Yun Sung;Nahm, Kee Suk;Kim, Ki Ju;Lee, Hong Ki
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.568-574
    • /
    • 1997
  • The effect of microencapsulation of maetal hydride (MH) with copper on the electrode performance of a Ni/MH battery has been investigated. The MH electrodes were prepared with a combination of cold press and paste methods. The discharge capacity of the electrode increased with an addition of small amounts if CMC into the electrode, but decreased when heat-treated in an oxygen-free nitrogen flow. The capacity of a Cu-coated $LaNi_5$ electrode was higher than that of LaNi5electrode. The discharge capacity of the electrode prepared with Cu-coated $LaNi_5$ increased with the increase of copper content in the electrode. It is considered that the increase of copper content enhanced the current density on the electrode surface, leading to the increase of the discharge capacity The MH electrode coated by an acidic electroless plating method showed much higher discharge capacity than that using an alkaline electroless plating method. The discharge capacity of the $LaNi_{4.5}Al_{0.5}$ electrode was higher than that of the $LaNi_5$ electrode. Also, the effect of microencapsulation on the deactivation of $LaNi_5$ was studied using an absorption-desorption cycle in CO-containing hydrogen.

  • PDF

Improvement of the Planting Method to Increase the Carbon Reduction Capacity of Urban Street Trees

  • Kim, Jin-Young;Jo, Hyun-Kil;Park, Hye-Mi
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.2
    • /
    • pp.219-227
    • /
    • 2021
  • Background and objective: Urban street trees play an important role in carbon reduction in cities where greenspace is scarce. There are ongoing studies on carbon reduction by street trees. However, information on the carbon reduction capacity of street trees based on field surveys is still limited. This study aimed to quantify carbon uptake and storage by urban street trees and suggest a method to improve planting of trees in order to increase their carbon reduction capacity. Methods: The cities selected were Sejong, Chungju, and Jeonju among cities without research on carbon reduction, considering the regional distribution in Korea. In the cities, 155 sample sites were selected using systematic sampling to conduct a field survey on street environments and planting structures. The surveyed data included tree species, diameter at breast height (DBH), diameter at root collar (DRC), height, crown width, and vertical structures. The carbon uptake and storage per tree were calculated using the quantification models developed for the urban trees of each species. Results: The average carbon uptake and storage of street trees were approximately 7.2 ± 0.6 kg/tree/yr and 87.1 ± 10.2 kg/tree, respectively. The key factors determining carbon uptake and storage were tree size, vertical structure, the composition of tree species, and growth conditions. The annual total carbon uptake and storage were approximately 1,135.8 tons and 22,737.8 tons, respectively. The total carbon uptake was about the same amount as carbon emitted by 2,272 vehicles a year. Conclusion: This study has significance in providing the basic unit to quantify carbon uptake and storage of street trees based on field surveys. To improve the carbon reduction capacity of street trees, it is necessary to consider planning strategies such as securing and extending available grounds and spaces for high-density street trees with a multi-layered structure.