• Title/Summary/Keyword: Capacity Range

Search Result 1,873, Processing Time 0.025 seconds

Prediction of Bulk Type Trailer Capacity in Consideration of Soil Physical Properties of Paddy Field (논 토양의 물리적 특성을 고려한 산물형 트레일러의 적정용량 예측)

  • 박원엽;이규승
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • A computer simulation was carried out to determinate the optimum capacity of bulk type trailer which is used as a tractor attachment. Soil physical properties. such as soil moisture content. bulk density, soil hardness and soil texture were measured in the 10 major rice production area for computer simulation. Mathematical model which include soil physical properties and vehicle factor was used for computer simulation. Most of the soil texture of the investigated area was silty loam. Soil moisture content ranged between 30 and 40% mostly. Soil bulk density was in the range of 1.500 to 1.700 kg/㎥. Soil hardness ranged between 1 to 18 kg/$\textrm{cm}^2$. Soil hardness incorporate the effects of many soil physical properties such as moisture content texture and bulk density, and so the range of soil hardness was greater than any other physical properties. The capacity of bulk type trailer was above 3000 kg$_{f}$ fer the most of the investigated area. and mostly in the range of 4000 to 6000 kg$_{f}$ depending upon the slip. But for the soft soil area such as Andong and Namyang. tractor itself had mobility problem and showed minus trailer capacity for some places. For this area. the capacity of bulk type trailer ranged between 1000 and 2000 kg$_{f}$ mostly so bulk type trailer should be designed as a small capacity compared to the other area.ared to the other area. area.

Determination of Serum Iron, Iron-Binding Capacity and Transferrin Saturation in_Health (건강인(健康人)의 혈청철(血淸鐵), 철결합능(鐵結合能) 및 transferrin saturation 측정(測定)에 관(關)하여)

  • Tchai, B.S.
    • Journal of Nutrition and Health
    • /
    • v.3 no.3
    • /
    • pp.141-147
    • /
    • 1970
  • Nutritional anemias are an important nutritional problem affecting large population groups in most developing countries. Many reports on investigations of nutritional anemias have been published and there is good evidence that prevalence of iron deficiency anemias in vulnerable groups is high in many areas of the world. However, there is a general lack of accurate data on its prevalence throughout the world. Methods used to measure different factors have been variable and often of poor quality. Furthermore recent comparison of values obtained in different laboratories have shown a much greater discrepancy in iron binding capacity measurements as compared with serum iron determinations. Since the major cause of these differences appears related to the technique employed, the efforts of the central laboratory will be directed initially to standardization of methodology. My laboratory has been joined interlaboratory comparison of WHO studies of iron standardization. The determination of serum iron, iron-binding capacity and transferrin saturation was done on healthy adults, 79 males and 20 females, who visited hospital for health certificate from January to July 1970. The serum iron was determined by the method of modification of Bothwell and Mallett and total iron blinding capacity by Ramsay method and Bothwell and Mallett method. The results of this study are as follows; 1) The serum iron concentration of seventy nine adult male by the method presented is $131.5{\pm}37.3{\mu}g/100ml\;(range\;52.5{\sim}225.0{\mu}g/100ml)$ and of twenty female adult is $108.5{\pm}40.2{\mu}g/100ml\;(range\;45.0{\sim}202.5{\mu}g/100ml)$. 2) The adult male level of serum iron-binding capacity is $330.9{\pm}48.9{\mu}g/100ml\;and\;adult\;female\;is\;291.2{\pm}55.2{\mu}g/100ml$. 3) The transferring saturation of healthy male is $35.6{\pm}12.8%\;(range\;15.1{\sim}18.0%)\;and\;of\;female\;as\;25.4{\pm}12.4%\;(range\;10.1{\sim}60.0)$.

  • PDF

A Study on the Determination for Stochastic Reservoir Capacity (추계학적 저수용량 결정에 관한 연구)

  • Choe, Han-Gyu;Choe, Yong-Park;Kim, Chi-Hong
    • Water for future
    • /
    • v.19 no.2
    • /
    • pp.149-156
    • /
    • 1986
  • The generated sequences of monthly flows were analyzed based on the range concept. With the optimum operation rule of the reservoirs as the one which maximizes the wateruse downstream the waterrelease from the reservoir was determined and with \ulcorner consideration to the mean inflows and the range of monthly flows the required reservoirs capacity was stochastically determind. It is suggested that the result obtained in this study would be applied to approximately estimate, in the stage of preliminary design, the required capacity of a reservoir in question with the limited information such as the mean monthly inflow and the period of reservoir operation. For the determination of a reservoir capacity Rippl's mass-curve method has been long used with the past river flow data assuming the same flow records will be repeated in the future. This study aims to find out a better method for determining the reservoir capacity by employing the analytical theory based on the stochastic process. For the present study the synthetic generation methods of Thomas-Fiering type was used to synthetically generate 50 years of monthly river inflows to three single-purpose reservoirs and three multi-purpose reservoirs.

  • PDF

A Study on Insulation Degradation Properties of Thermal Conductive Silicone Rubber due to Temperature Transition (온도 변화에 의한 열전도성 실리콘 고무의 절연 열화 특성)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.456-461
    • /
    • 2015
  • In this study, the frequency properties of electrostatic capacity and dielectric loss for the samples with different types of filler has been measured in through the applied frequency range of 7 kHz ~3,000 kHz at temperature of $80^{\circ}C$, $110^{\circ}C$, $140^{\circ}C$, $170^{\circ}C$. The results of this study are as follows. When the sample is degradated at the temperature of $80^{\circ}C$, $110^{\circ}C$, $140^{\circ}C$, $170^{\circ}C$ and the frequency range of 7 kHz ~3,000 kHz is applied, It found that the electrostatic capacity of the sample with Polyimide film is larger than the sample with Grass fiber. It found that the dielectric loss for the sample with Polyimide film is larger than the sample with Grass fiber with increasing frequency and temperature in the $80^{\circ}C$, $110^{\circ}C$, $140^{\circ}C$, $170^{\circ}C$ range. Also, the dielectric loss decreased with increasing frequency. In case of the sample with Polyimide film, It found that the electrostatic capacity decreased with increasing temperature, and the dielectric loss gradually decreased with increasing frequency.

Effect of ε Martensite Content and Strain Amplitude on Damping Capacity of Fe-17%Mn Alloy (Fe-17%Mn 합금의 진동감쇠능에 미치는 ε 마르텐사이트 함량과 진폭변형율의 영향)

  • Jun, Joong-Hwan;Lee, Young-Kook;Choi, Chong-Sool
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.9 no.2
    • /
    • pp.112-120
    • /
    • 1996
  • The effects of ${\varepsilon}$ martensite content and strain amplitude on damping capacity of an Fe-17%Mn alloy have been studied to establish damping mechanism of Fe-Mn system corresponding to the magnitude of strain amplitude. In a range of $1{\times}10^{-4}{\sim}3{\times}10^{-4}$ strain amplitude, the damping capacity is linearly proportional to the ${\varepsilon}$ martensite content, which suggests that stacking faults and ${\varepsilon}$ martensite variant boundaries are the principal damping sources. In the range of $4{\times}10^{-4}{\sim}6{\times}10^{-4}$ strain amplitude, however, a maximum damping capacity is observed around 68 vol.% ${\varepsilon}$. This behavior is very similar to dependence of relative area of ${\gamma}/{\varepsilon}$ interface on ${\varepsilon}$ martensite content. This means that in this strain range, ${\gamma}/{\varepsilon}$ interface acts as damping source in addition to the stacking faults and variant boundaries in Fe-17%Mn alloy.

  • PDF

Adsorption Characteristics of Benzene by Carbonized Cast (탄화분변토를 이용한 Benzene의 흡착특성)

  • 김재홍;손희정;김미룡
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.1
    • /
    • pp.97-102
    • /
    • 1999
  • This study was carried out view that reuse of sludge of adsorbent for benzene in carbonized cast compare with activated carbon. Not only the carbonized cast is good than carbonized carbon in cation exchange capacity and 12 adsorption capacity, but also benzene adsorption capacity is no differences compare to activated carbon. As results, benzene adsorption capacity of carbonized cast and activated carbon are decreased as temperature increase($25~70^{\circ}C$).It is compatible in Lamgmuir model. Therefore, carbonized cast is applied general adsorbent. From experimental results and data regression, in model concerning effect of temperature, relative errors between the experimental data and those calculated by the model are within the range of 1.2~7.8%. In relative humidity effect (RH 0.25~0.50) of benzene adsorption, modified Freundlich model : $QB_{enzene}{;\}QB_{enzene},{\}_{RH=0}=1-kRH^{IN}$, relative errors between the experimental data and those calculated by the model are within are range of 0.5-5.1%. The constants k and l/n in equation were found to be 1.25, 1.89 in carbonized cast.

  • PDF

Cation Exchange Capacity and Zeta Potential Characteristics of Kaolinite Contaminated with Lead (납으로 오염된 카올리나이트의 양이온교환능력 및 계면동전위 특성)

  • 장경수;강병희
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.38-43
    • /
    • 2002
  • A series of tests were performed to investigate the effects of pH and contamination level on cation exchange capacity and zeta potential in kaolinite loaded with lead. Test results show that cation exchange capacity of kaolinite is found to be in the range from 4 to 20meq/100g and it increased with increasing pH up to the converged number about 20meq/100g over pH 8. And then CEC has a tendency to reduce and converge to zero with increasing the concentration of Pb in the kaolinite surface. Moreover, zeta potential of kaolinite contaminated with lead is found to be in the range from -10 to 5mV, and zero point of charge is measured at about pH 3.5. Zeta potential of kaolinite contaminated with lead decreases with increasing pH values and decreasing Pb concentration of kaolinite.

  • PDF

Electric Properties of Thermal Conductive Silicone Rubber due to Thermally Degradation (열 열화한 열전도성 실리콘 고무의 전기특성)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.12
    • /
    • pp.835-840
    • /
    • 2016
  • In this study, the electrostatic capacity and dielectric loss tangent for $20{\mu}m$ thick thermal conductivity silicone rubber which is heated at 80 degrees for 8 hours has been measured at temperature of $30^{\circ}C{\sim}170^{\circ}C$, frequency of 0.1~1 MHz. The results of degradation evaluation by this study are as follows. In low frequency, it found that the electrostatic capacity decreased with increasing temperature. On the other hand, it confirmed that the range of the electrostatic capacity narrowed with increasing frequency. It confirmed that there are the carboxylic acid structure and C-O bonding at range of wave number 1,000cm-1 to 1,300cm-1.

A study on the determination for stochastic reservoir capacity (추계학적(推計學的) 저수용량(貯水容量) 결정(決定)에 관(關)한 연구(硏究))

  • Choi, Han-Kuy
    • Journal of Industrial Technology
    • /
    • v.3
    • /
    • pp.69-74
    • /
    • 1983
  • For the determination of a reservoir capacity Rippl's mass-curve method has long been used with the past river flow data assuming the same flow records will be repeated in the future. This study aims to find out a better method for determining the reservoir capacity by employing the analytical theory based on the stochastic process. For the present study the synthetic generation methods of Thomas-Fiering type was used to synthetically generate 50 years of monthly river inflows to three single-purpose reservoirs and three multi-purpose reservoirs. The generated sequences of monthly flows were analyzed based on the range concept. With the optimum operation rule of the reservoirs as the one which maximizes the water-use downstream the waterrelease from the reservoir was determined and with due consideration to the mean inflows and the range of monthly flows the required reservoirs capacity was stochastically determined. It was possible to repersent the so-determined reservoir capacity in terms of the mean monthly inflows and the number of subseries in the determination of ranges. It is suggested that the result obtained in this study would be applied to approximately estimate, in the stage of preliminary design, the required capacity of a reservoir in question with the limited information such as the mean monthly inflow and the period of reservoir operation.

  • PDF

An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation (고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구)

  • Ahn, Jae Hwan;Joo, Youngju;Yoon, Won Jae;Kang, Hoon;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.