• Title/Summary/Keyword: Capacity Factor

Search Result 2,252, Processing Time 0.028 seconds

Innovation Capacity of Student: A Case Study in Vietnam

  • DO, Anh Duc;PHAM, Nguyen Nguyen Thao;NGUYEN, Thi Minh Phuong;TU, Van Son;NGUYEN, Cam Nhung;NGUYEN, Hai Duong
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.5
    • /
    • pp.189-199
    • /
    • 2021
  • This study aimed to explore the factors affecting the innovation capacity of students at the National Economics University, Vietnam. Researchers used the innovation capacity model based on six factors, including personality traits, future orientation, creative skills, social interaction, content knowledge, and management skills. The empirical analysis used data from the survey of 303 students at National Economics University, Vietnam, with reliable tools (SPSS 26.0 software). The data were analyzed by testing the reliability of the scales, correlation analysis, and Pearson' Linear Correlation Coefficient, exploratory factor analysis, as well as regression model based on the survey data. The research results identified the following factors affecting innovation capacity of students: management skills, social interaction, and personality traits have the strongest impact on innovation capacity of students; content knowledge has the following strongest effects on innovation capacity of students; and finally the creative skills that affects on innovation capacity of students. There is also a positive relationship between all the factors and innovation capacity of students. The result can serve as useful reference sources for scholars who are interested in the innovation field. It also helps university's managers and policymakers build the appropriate environment to improve innovation capacity of students.

A Study on Social Carrying Capacity by Normative Approach of Perceived Crowding (혼합지각의 규범적 접근에 의한 사회적 수용능력에 관한 연구 : - 내장산국립공원 단풍이용객 대상의 사례연구 -)

  • Park Chung-In
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.1 s.108
    • /
    • pp.10-18
    • /
    • 2005
  • The main concept of social carrying capacity is based on the principle that 'there are limits to the number of users a given recreation site can accommodate in order to provide quality of recreation experience'. The quality of the experience is revealed as user's satisfaction and perceived crowding. In this respect, studies of social carrying capacity have been frequently conducted by measuring perceived crowding and satisfaction. The purpose of this study is to identify the variables affecting perceived crowding, and causality bet-ween satisfaction and perceived crowding. Four hundred seventy six visitors were selected at Naejangsan National park on peak day of autumn excursion through on-site survey. The collected data were applied by factor analysis for categorizing the research variables, and multiple regression for finding the causality among variables. The study results are follows. The expectation of crowding, as a normative variable for perceived crowding, are categorized by three factors; circulation, user facility, and landscape. The circulation factor is the most powerful affecting perceived crowding among three factor. The landscape factor, however, do not have statistical significance on perceived crowding. The causality between satisfaction and perceived crowding is found. Although this relation is significant in statistics, magnitude of the coefficient is very small. It might be interpreted that satisfaction cannot be predicted simply from a user's perception of crowding, but a multi-dimensional concept such as adaptation and coping behavior.

Performance Analysis of long term operation for photovoltaic system (태양광발전시스템의 장기운전에 의한 성능변화 분석)

  • Kim, EuiHwan;Kim, Jungsam
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.110.1-110.1
    • /
    • 2011
  • This study analyzed the performance of long term operation photovoltaic system The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 12 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 38.0 MWh in 2010. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 8.8% in 2011. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 12 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

  • PDF

A Comparative Study on the Evaluation of Bearing Capacity for Driven Pile in Static Load Test (현장정재하시험 결과를 통한 타입말뚝 지지력 판정법 비교 연구)

  • Chun, Byung-Sik;Seo, Deok-Dong;Choi, Heon-Kil;Yoon, Hwan-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.677-686
    • /
    • 2005
  • The allowable bearing capacity of a pile, the most important factor in stability estimation, is determined by applying safety factor to the ultimate load or yield load. There are several but contradictory methods available in current design codes to estimate the allowable bearing capacity and the safety factor. This paper analyzes load-settlement curves obtained from 19 static load tests measured from 11 sites. At all tests, the load is applied until apparent failure is observed. The validity of the ultimate and yield load estimation method and load caculated from the settlement criterion is investigated through comparison with the measured data. In addition, a new procedure to estimate allowable load and safety factor is proposed. Additional data from field static load tests, such as those incorporated in this study, are needed to more reliably apply the proposed method in design practice.

  • PDF

The long-term operating evaluation of the grid connected photovoltaic system (중규모 태양광발전시스템 장기 실증운전 평가)

  • Kim, Eui-Hwan;Ahn, Kyo-Sang;Lim, Hee-Chun
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.14-19
    • /
    • 2009
  • The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 10 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 41.9 MWh in 2008. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 9.6% in 2008. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 10 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

A Secure MQAM Scheme Based on Signal Constellation Hopping

  • Zhang, Yingxian;Liu, Aijun;Pan, Xiaofei;Ye, Zhan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.7
    • /
    • pp.2246-2260
    • /
    • 2014
  • In this paper, a secure multilevel quadrature amplitude modulation (MQAM) scheme is proposed for the physical layer security (PLS) of the wireless communications. In the proposed scheme, each transmitted symbol's signal constellation (SC) is hopping with the control of two unique factors: amplitude distortion (AD) factor and phase hopping (PH) factor. With unknown the two factors, the eavesdropper cannot extract effective information from the received signal. We first introduce a security metric, referred to as secrecy gain, and drive a lower bound on the gain that the secrecy capacity can be improved. Then, we investigate the relationship among the secrecy gain, the signal to noise power ratios (SNRs) of the main and wiretap channels, and the secrecy capacity. Next, we analyze the security of the proposed scheme, and the results indicate that the secrecy capacity is improved by our scheme. Specifically, a positive secrecy capacity is always obtained, whether the quality of the main channel is better than that of the wiretap channel or not. Finally, the numerical results are provided to prove the analytical work, which further suggests the security of the proposed scheme.

Investigation on Selecting Optimal Wind Turbines in the Capacity Factor Point of View (이용률 관점에서의 최적 풍력발전기 선정에 대한 연구)

  • Woo, Jae-Kyoon;Kim, Byeong-Min;Paek, In-Su;Yoo, Neung-Soo;Nam, Yoon-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.60-66
    • /
    • 2011
  • Selecting optimal wind turbine generators for wind farm sites in the capacity factor point of view is performed in this study. A program to determine the best wind turbine generator for the maximum capacity factor for a site was developed. The program uses both the wind characteristics of the site of interest and the power curves of the wind turbines. The program developed was applied to find out optimal wind turbine generators of three different sites in complex terrain and successfully yielded the best site dependent wind turbine generators. It was also used to determine the best wind turbine generator of the wind farm currently operating in Korea and proved its usefulness. The program and methodology developed in this study considered to be very useful at the initial design stage of the wind farm to determine the best wind turbine generators for the site of interest.

A Study on the Adequacy Evaluation of Criteria of Occupant Load Factor in Residential Buildings (주거용 건축물의 재실자밀도 기준 적정성 평가에 관한 연구)

  • Seo, Dong-Goo;Hwang, Eun-Kyoung
    • Journal of the Korean housing association
    • /
    • v.27 no.6
    • /
    • pp.145-153
    • /
    • 2016
  • The purpose of this study is to grasp the effectiveness of evacuation safety design by verifying the appropriateness of the standard of occupant load factor for residential buildings. To this end, the definition and current standard of occupant load factor for residential buildings were analyzed, and the problems of the current standard were clarified by interviewing professionals. In addition, changes in occupant load factor were examined by year based on statistical research, and evaluation on the current standard $18.6m^2/pers.$ was performed. As for evaluation methods, the need of redesigning of evacuation capacity was investigated by using evacuation simulation. As a result of the analysis, the most serious problem was clarification of the applicable standard for residential officetel, where the average occupant load factor was $26.1m^2/pers.$, which was not appropriate. However, as a result of evaluation on evacuation capacity, although there was no difference between statistical research results and the current standard in terms of evacuation capacity, when the standard for business facilities was applied to officetel, evacuation time doubled. Thus, this study suggests that when the current standard is applied to residential officetel, it is necessary to separate between residential use and business use.

The Optimal Condenser Position & Capacity for Power Factor Compensation in Distribution System (배전계통의 역률보상 콘덴서의 최적 위치 및 용량 산정)

  • Jang, Jeong-Tae;Jeon Young-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1190-1197
    • /
    • 1999
  • The management of power factor(PF) in the distribution line is treated according to the measurement a month about the feeder unit at the substation. In Korea, we have not researched into power factor in distribution system due to it's less weight. The reactive power in advanced countries is controlled automatically by the compensative condenser switch on/off under the monitoring. This paper first presents the optimal condenser position and proper capacity by lagrangue factor ${\lambda}_{Q}$ which is the line loss index about reactive power unit. Therefore, the largest ${\lambda}_{Q}$ node is the condenser injection point and we find out the best condenser capacity when the line loss is saturated by the moderation of condenser volume. By this method, we suggest 0.6% uprising PF by injection of 15 kVA condenser. Additionally, PF is analysed into 5 areas; large city, middle city, small city, farm village, fishing village by the use of Power Platform which is classified the same concept of the low load management in KEPCO. Two feeders of each area are selected by the worst results of PF in specified areas.

  • PDF

Cost Scaling Factor according to Power Plant Capacity Change (발전소 용량변경에 따른 비용보정계수)

  • Ha, Gak-Hyeon;Kim, Sung-Hwan
    • Journal of Energy Engineering
    • /
    • v.22 no.3
    • /
    • pp.283-286
    • /
    • 2013
  • The existing nuclear power plants have been often redesigned by increasing or decreasing electrical power without changing design concept by the request of utility, economic factors or other factors. When the cost of power plant equipment redesigned by changing reactor power and electrical power is estimated, if its quotation is not available in the market place, cost scaling factor(CSF) applies to the cost of existing plant equipment and then the new-designed equipment cost can be calculated. In this paper, we review CSFs according to plant capacity change cases in United State DOE, EPRI, ABB, SWEC and introduce the results applied to Korean PWR 1000MWe and 1400MWe.