• Title/Summary/Keyword: Capacity Conversion

Search Result 409, Processing Time 0.023 seconds

A study of control capacity structure of by the lipoid state of stratum on the skin (피부각질의 유지질상태에서 조절기능구조에 관한 연구)

  • Kim, Jeong-Lae;Kim, Hye-Ju
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.3
    • /
    • pp.37-42
    • /
    • 2017
  • We are designed to control the lipoid variation of the structure system with the stratum corneum on the skin. The skin structure is consisted of a morphology how to use the lipoid component, and the given skin structure is consisted of the mechanical shapes of the intercellular route and transcellular route, and is confirmed to control the variation state of the structure capacity. The skin impedance is appeared to result the value of measurement such as shapes of ${\lambda}-Lip-RSC$, ${\lambda}-Lip-RSL$, ${\lambda}-Lip-CSG$, ${\lambda}-Lip-CSS$ and ${\lambda}-Lip-RSB$. The condition is showed to the alteration difference value of the intercellular route and transcellular route. And, composition condition is established to separate the division parts for conversion system that is constructed with the alteration modeling. We will be possible to progress the improvement effectiveness of the continuous skin control system on the skin.

A Study on Na effect of Pt-Na/Ce(1-x)Zr(x)O2 Catalyst Structure for WGS Reaction (WGS 반응에서 Pt-Na/Ce(1-x)Zr(x)O2 촉매의 구조에 따른 Na 영향에 대한 연구)

  • Shim, Jae-Oh;Jeong, Dae-Woon;Jang, Won-Jun;Roh, Hyun-Seog
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.654-659
    • /
    • 2012
  • The interest in water gas shift (WGS) reaction has grown significantly, as a result of the recent advances in fuel cell technology and the need to develop small-scale fuel processors. Recently, researchers have tried to overcome the disadvantages of the commercial WGS catalysts. As a consequence, supported Pt catalysts have attracted a lot of researchers due to high activity and stability for WGS at low temperatures. In this study, $Pt-Na/Ce_{(1-x)}Zr_{(x)}O_2$ catalysts with various Ce/Zr ratio have been applied to WGS at a gas hourly space velocity (GHSV) of $45,515h^{-1}$. According to TPR patterns of $Pt-Na/Ce_{(1-x)}Zr_{(x)}O_2$ catalysts, the reducibility increases with decreasing the $ZrO_2$ content. As a result, Cubic structure $Pt-Na/Ce_{(1-x)}Zr_{(x)}O_2$ catalysts exhibited higher CO conversion than tetragonal structure $Pt-Na/Ce_{(1-x)}Zr_{(x)}O_2$ catalysts. Expecially, Pt-Na/$CeO_2$ exhibited the highest CO conversion as well as 100% selectivity to $CO_2$. Moreover, Pt-Na/$CeO_2$ catalyst showed relatively stable activity with time on stream. The high activity of cubic structure Pt-Na/$CeO_2$ catalyst was correlated to its higher oxygen storage capacity (OSC) of $CeO_2$ and easier reducibility of Pt/$CeO_2$.

Analysis of 1MW Closed OTEC Cycle Using Thermal Effluent and Waste Heat (발전소 온배수를 이용한 1MW급 폐쇄형 해양온도차발전 성능해석)

  • Kim, Hyeon-Ju;Lee, Ho-Saeng;Jung, Dong-Ho;Moon, Deok-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.470-476
    • /
    • 2010
  • The thermodynamic performance of closed ocean thermal energy conversion (OTEC) cycle with 1 MW gross power was evaluated to obtain the basic data for the optimal design of OTEC. The basic thermodynamic model for OTEC is Rankine cycle and the thermal effluent from power plant was used for the heat source of evaporator. The cycle performance such as efficiency, heat exchanger capacity, etc. was analyzed on the temperature variation of thermal effluent. The saturated pressure of evaporator increased with respect to the increase of thermal effluent temperature, so the cycle efficiency increased and necessary capacity of evaporator and condenser decreased under 1 MW gross power. As the thermal effluent temperature increases about $15^{\circ}C$, the cycle efficiency increased approximately 44%. So, it was revealed that thermal effluent from power plant is important heat source for OTEC plant. Also, if there is an available waste heat, it can be transferred heat to the working fluid form the evaporator through heat exchanger and cycle efficiency will be increased.

Determination of The Growth Performances and Meat Quality of Broilers Fed Saccharomyces cerevisiae as a Probiotic in Two Different Feeding Intervals

  • Macelline, W.H.D. Shemil Priyan;Cho, Hyun Min;Awanthika, H.K. Thilini;Wickramasuriya, Samiru Sudharaka;Jayasena, Dinesh. D.;Tharangani, R.M. Himali;Song, Zhang;Heo, Jung Min
    • Korean Journal of Poultry Science
    • /
    • v.44 no.3
    • /
    • pp.161-172
    • /
    • 2017
  • This study was conducted to determine the effect of Saccharomyces cerevisiae (SC) as a dietary probiotic and evaluated the most suitable feeding interval for this probiotic on growth performance, carcass yield, and meat quality parameters in broiler chickens. In total, 1,050 one-day-old Cobb 500 chicks were randomly assigned to one of seven dietary treatment groups, in a $2{\times}3$ factorial arrangement with 3 SC dosages (0.6%, 1%, and 1.4%) and two feeding intervals [long term (LT) for 35 days and short term (ST) for 28 days after hatching], with a negative control diet (NC; 0% SC). Triplicate experiments were performed with 50 birds per cage. Broilers fed a diet including SC showed increased (p<0.01) daily gain and feed efficiency compared to the control. Further, broilers fed the 1.4% SC supplemented diet showed a significantly increased (p<0.01) average daily gain (ADG) and feed conversion ratio (FCR) compared to broilers fed the 0.6% and 1% SC incorporated diets. Similarly, broilers fed an LT SC diet showed a greater (p<0.01) increase in ADG and FCR compared to broilers fed an ST SC diet. Moreover, broilers fed an LT SC diet displayed a reduced (p<0.05) meat pH, gizzard weight, and increased (p<0.05) meat water-holding capacity compared to broilers fed an ST SC diet. Broilers fed the 1.4% SC supplemented diet showed increased (p<0.05) thigh muscle weight compared to broilers fed the 0.6% and 1% SC supplemented diets. In conclusion, broilers fed LT SC diets showed improved growth performance and carcass quality parameters compared to broilers fed ST SC diets, and the NC diet, from hatching to day 35.

Performance Characteristics of a Mixed Refrigerant OTEC Power Cycle Using Hot Waste Water (온배수를 이용한 혼합냉매용 해양온도차 발전 사이클의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Heo, Jeong-Ho;Ye, Byoung-Hyo;Kim, Hyun-Ju;Lee, Ho-Saeng
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.102-107
    • /
    • 2013
  • In this paper, the performance analysis for evaporation capacity, total work and efficiency of the ocean thermal energy conversion(OTEC) power system using mixed refrigerant(R32,R152a) is conducted to find the effect of hot wasted water on OTEC power system. The system in this study is applied with two stage turbine, regenerator, cooler and separator on Organic Rankine Cycle. The commercial program HYSYS is used for the performance analysis. The main results were summarized as follows : The efficiency of the OTEC power cycle has a largely effect on the evaporation capacity and total work. As increasing temperature of heat source water, evaporator's capacity is decreased but total work increase. Otherwise, using hot wasted water bring effects not only increasing system efficiency but also declining evaporator's capacity. Thus With a thorough grasp of these effect, it is necessary to find way to use hot wasted water emitted by power plant and so on.

Cell Radius & Guard Band Requirements by Mutual Interference Investigation between Satellite Digital Systems using Gap-filler (Gap-filler를 이용하는 위성 DMB 시스템 간의 상호간섭분석에 의한 보호대역 및 적정 셀 반경 설정)

  • Cha Insuk;Park SungHo;Chang KyungHi;You Heung-Ryeol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.6A
    • /
    • pp.499-509
    • /
    • 2005
  • The capacity of Satellite DMB(Digital Multimedia Broadcasting) system is limited mainly by the interference. So, to achieve the expected performance of Satellite DMB system and to minimize the interference from other Satellite DMB system, ACI(Adjacent Channel Interference) should be considered carefully. Satellite DMB system uses the Gap-filler for effective transmission in terrestrial environment, and the Gap-filler can use direct amplification or frequency conversion to satisfy the specific requirements. Therefore, amplified signal causes several effects on interference between System A(Eureka 147 DAB) and System E(ISDB : Integrated services Digital Broadcasting). In this paper, by using the outcome of system-level simulation considering the results of link-level simulation, we analyze the interferences between System A and System E under practical situation based on the exact parameters of ITU-R BO. 1130-4. We also propose the appropriate level of guard band and Cell Radius to optimize system capacity by adapting the spectrum mask given in the spec. and utilizing the interference analysis between System A and System E.

A Conversion of Load Carrying Capacity for Existing Steel Box Girder Bridge Based on Limit State Design Method (한계상태설계법에 의한 기존 강박스거더교의 내하력 환산)

  • Noh, Dong-Oh;Kyung, Kab-Soo;Park, Jin-Eun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.89-96
    • /
    • 2018
  • Bridge structures are a socially important infrastructure and safety management of bridges during the public service period is important. Steel box girder bridges, which account for a large percentage of road bridges, have been designed by allowable stress design method(ASD) and load carrying capacity have been evaluated using ASD. Although design specification has recently been changed to limit state design method(LSD), in most cases, ASD is still used for load carrying capacity evaluation. In this study, the two design methods were used to compare the results of a load rating factor evaluation on a number of bridges, and we are going to find out how to convert the existing rating factor by ASD into rating factor by LSD. The results of this study are expected to can be used as a basis for determining the need for reinforcement and evaluating load carrying capacity by LSD in bridge maintenance.

Evaluation of Clostridium autoethanogenum protein as a new protein source for broiler chickens in replacement of soybean meal

  • Xing Chen;Aijuan Zheng;Ahmed Pirzado Shoaib;Zhimin Chen;Kai Qiu;Zedong Wang;Wenhuan Chang;Huiyi Cai;Guohua Liu
    • Animal Bioscience
    • /
    • v.37 no.7
    • /
    • pp.1236-1245
    • /
    • 2024
  • Objective: The object of this study was to investigate the effect of replacing soybean meal with Clostridium autoethanogenum protein (CAP) in broiler diets on growth performance, blood indicators, antioxidant capacity, and immune function. Methods: A total of 180 Arbor Acres broilers were randomly divided into three treatments, each treatment with six replicates and 10 broilers per replicate for a 42-day feeding trial. The control group (CON) was fed corn-soybean meal based diet. The CAP-1 and CAP-2 groups were considered to use CAP to replace 25% or 50% of soybean meal in the diet, respectively. The average daily gain and average daily feed intake of broilers at 1 to 21 d, 22 to 42 d, and 1 to 42 d were measured, and the feed conversion ratio was calculated. At the 42nd day of age, two broilers with similar weights and fasted for 12 h were selected in each replicate for blood collection from the brachial wing vein. The blood routine indicators, serum biochemical indicators, serum antioxidant capacity, and immunoglobulin content of broiler chickens were measured. Results: Replacement of soybean meal with 25% (CAP-1) and 50% (CAP-2) CAP significantly increased the average daily gain of 22 to 42 d and 1 to 42 d and decreased the average daily feed intake and feed conversion rate (p<0.05). The CAP-1 group, and CAP-2 group significantly increased hemoglobulin in the blood of broilers, while the CAP-2 group increased hematocrit content (p<0.05). Compared with the control group, the contents of superoxide dismutase and immunoglobulin A in serum of the CAP-2 group were significantly increased, while the contents of malondialdehyde in CAP group were significantly decreased (p<0.05). Conclusion: Replacing soybean meal with CAP led to significant improvements in the growth performance, antioxidant capacity, and immunoglobulin content of broilers.

A Study on Application of a Heat Recovery Ventilator using Photovoltaic System in School (학교 교실의 태양광발전 환기시스템 적용성 연구)

  • Jang, Yong-Sung;Suh, Seung-Jik;Hong, Sung-Hee;Yu, Kwon-Jong;Park, Hyu-Soon
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.27-34
    • /
    • 2005
  • This study aims to evaluate application of a heat recovery ventilator(HRV) using photovoltaic(PV) system. To this end, we analyzed performance of a PV system, which it was evaluated by monthly power wattage and conversion efficiency according to design capacity of a HRV. The results of this study can be summarized as follows. (1) A conversion efficiency of the PCS was evaluated about 86% in rated power. (2) A maximum, minimum and average output power were respectively analyzed 49.2W, 47.3W, and 48.8W. (3) Total power wattage of 200W PV system was 211kW and it was 316kW in case of 300W PV system. (4) Insufficient electrical power of a duct and window type ventilation system was respectively calculated 133.5kW and 147.7kW.

A Plug-in Development for Interworking between SysML Model and Plant Information (SysML모델과 플랜트정보 간 상호연동을 위한 플러그인 개발)

  • Kim, Joon Young;Lee, Tae Kyong;Cha, Jae Min
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.15 no.2
    • /
    • pp.17-30
    • /
    • 2019
  • Due to difficulties in tracking design information of existing document-based configuration management, the research on the development of plant SysML model was started to apply the model-based system engineering methodology to comprehensively manage various design information. However, until now, in order to create the SysML model, the engineers are checking the design information and inputting it to the SysML model. This process requires a lot of time and manpower, it is required to minimize it. Therefore, this study has recognized the problem, a plug-in that extracts the plant design information in the design document and automatically converts the SysML plant model from it. Specifically, the development was performed in the following order. First, the extraction file was selected as the most commonly used Excel file as the plant design document. Next, the design information in the document was analyzed, and extracted information including tag number, name, and the capacity were selected. Finally, the plant SysML model conversion module was implemented. The developed plug-in is confirmed that the task load of the engineers by the SysML model conversion can be minimized and the model can be generated more quickly and accurately.